Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 29
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Influence of Gradient and Smoothness of Atrial Wall Thickness on Initiation and Maintenance of Atrial Fibrillation

  • Azzolin, Luca
  • Luongo, Giorgio
  • Rocher-Ventura, Sara
  • Dossel, Olaf
  • Loewe, Axel
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] This work uses a highly detailed computational model of human atria to investigate the effect of spatial gradient and smoothing of atrial wall thickness on inducibility and maintenance of atrial fibrillation (AF) episodes. An atrial model with homogeneous thickness (HO) was used as baseline for the generation of different atrial models including either a low (LG) or high thickness gradient between left/right atrial free wall and the other regions. Since the model with high spatial gradient presented non-natural sharp edges between regions, either 1 (HG1) or 2 (HG2) Laplacian smoothing iterations were applied. Arrhythmic episodes were initiated using a rapid pacing protocol and long-living rotors were detected and tracked over time. Thresholds optimised with receiver operating characteristic analysis were used to define high gradient/curvature regions. Greater spatial gradients increased the atrial model inducibility and unveiled additional regions vulnerable to maintain AF drivers. In the models with heterogeneous wall thickness (LG, HG2 and HG1), 73.5 ± 8.7% of the long living rotors were found in areas within 1.5 mm from nodes with high thickness gradient, and 85.0 ± 3.4% in areas around high endocardial curvature. These findings promote wall thickness gradient and endocardial curvature as measures of AF vulnerability, Research supported by the European Union's Horizon 2020 research and innovation programme under the Marie Sk¿odowska-Curie grant agreement No.766082 (MY-ATRIA project)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher-Ventura, Sara
  • Martínez-Mateu, Laura
  • Laranjo, Sergio
  • Laguna, Pablo
  • Martínez, Juan Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping modalities based on a modified version of the omnipolar electrogram method, which aims to reduce orientation-dependent residual components in the standard approach. Methods: A simulated electrical propagation in 2D, with a tissue including a circular patch of diffuse fibrosis, was used for validation. Unipolar electrograms were calculated in a multi-electrode array, also deriving bipolar electrograms along the two main directions of the grid. Simulated bipolar electrograms were also contaminated with real noise, to assess the robustness of the mapping strategies against noise. The performance of the maps in identifying fibrosis and in reproducing unipolar reference voltage maps was evaluated. Bipolar voltage maps were also considered for performance comparison. Results: Results show that the modified omnipolar mapping strategies are more accurate and robust against noise than bipolar and standard omnipolar maps in fibrosis detection (accuracies higher than 85 vs. 80% and 70%, respectively). They present better correlation with unipolar reference voltage maps than bipolar and original omnipolar maps (Pearson's correlations higher than 0.75 vs. 0.60 and 0.70, respectively). Conclusion: The modified omnipolar method improves fibrosis detection, characterization of substrate and propagation, also reducing the residual sensitivity to directionality over the standard approach and improving robustness against noise. Nevertheless, studies with real electrograms will elucidate its impact in catheter ablation interventions., This study has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 766082 (MY-ATRIA project), from projects PID2019-104881RB-I00, and PID2019-105674RB-I00 from MICINN, Spain, from Gobierno de Aragon (BSICoS Group T39-20R) cofunded by FEDER 20142020 Building Europe from Aragon and from Generalitat Valenciana through the fellowship ACIF/2018/174 and the grant PROMETEO/2020/043.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Computational simulations of the effects of the V17M missense mutation on atrial electrical activity

  • Belletti, Rebecca
  • Martínez Mateu, L.
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrillation is a cardiac arrhythmia responsible for disorganized electrical activity of the upper chambers of the heart. Recently genetic mutations have been associated to episodes of atrial fibrillation in asymptomatic patients, a condition called Lone AF. Indeed, genetic defects in ion channel protein structures can alter the flowing of the current through the pore. The aim of this work is to model and simulate the gain of function missense mutation V17M affecting the accessory subunit KCNE3 of the rapid delayed rectifier potassium channel, Kv11.1, found in a 46-years-old man affected by Lone AF. To accomplish this, the ventricular IKr Markov model proposed by Martin Fink and colleagues has been refitted to reproduce the behavior of the atrial IKr using an optimization procedure. Then, it was introduced into the atrial cellular model developed by Courtemanche Ramirez Nattel (CRN). Additionally, this model has been adjusted to fit experiments in literature in order to accurately reproduce the effects of the V17M mutation. The resulting wild-type IKr formulation mimics the CRN IKr time course at 0.5, 1 and 2 Hz, the activation time constants and the steady-state activation and inactivation curves. In addition, the V17M mutation formulation reproduces the experimentally reported electrophysiological alterations, which are approximately 3-fold increment of the current at high voltages and an almost 2-fold prolongation of the deactivation time constant. Simulation of the V17M mutation at the cellular level showed a 300% increase of the IKr peak, which shortened the action potential duration in 118.30 ms., Generalitat Valenciana, Prometeo programme 2016/088 and grant agreement 766082 European Union's Horizon 2020
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Arrhythmogenic Effects of Genetic Mutations Affecting Potassium Channels in Human Atrial Fibrillation: A Simulation Study

  • Belletti, Rebecca
  • Martínez-Mateu, Laura
  • Cherry, Elizabeth M.
  • Fenton, Flavio H.
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Genetic mutations in genes encoding for potassium channel protein structures have been recently associated with episodes of atrial fibrillation in asymptomatic patients. The aim of this study is to investigate the potential arrhythmogenicity of three gain-of-function mutations related to atrial fibrillation¿namely, KCNH2 T895M, KCNH2 T436M, and KCNE3-V17M¿using modeling and simulation of the electrophysiological activity of the heart. A genetic algorithm was used to tune the parameters¿ value of the original ionic currents to reproduce the alterations experimentally observed caused by the mutations. The effects on action potentials, ionic currents, and restitution properties were analyzed using versions of the Courtemanche human atrial myocyte model in different tissues: pulmonary vein, right, and left atrium. Atrial susceptibility of the tissues to spiral wave generation was also investigated studying the temporal vulnerability. The presence of the three mutations resulted in an overall more arrhythmogenic substrate. Higher current density, action potential duration shortening, and flattening of the restitution curves were the major effects of the three mutations at the single-cell level. The genetic mutations at the tissue level induced a higher temporal vulnerability to the rotor¿s initiation and progression, by sustaining spiral waves that perpetuate until the end of the simulation. The mutation with the highest pro-arrhythmic effects, exhibiting the widest sustained VW and the smallest meandering rotor¿s tip areas, was KCNE3-V17M. Moreover, the increased susceptibility to arrhythmias and rotor¿s stability was tissue-dependent. Pulmonary vein tissues were more prone to rotor¿s initiation, while in left atrium tissues rotors were more easily sustained. Re-entries were also progressively more stable in pulmonary vein tissue, followed by the left atrium, and finally the right atrium. The presence of the genetic mutations increased the susceptibility to arrhythmias by promoting the rotor¿s initiation and maintenance. The study provides useful insights into the mechanisms underlying fibrillatory events caused by KCNH2 T895M, KCNH2 T436M, and KCNE3-V17M and might aid the planning of patient-specific targeted therapies., This work was supported by the European Union's Horizon 2020 Research and Innovation Program under the Marie Sklodowska-Curie Grant Agreement No. 766082 (MY-ATRIA Project) and under the Grant Agreement No. 101016496, by Direccion General de Politica Cientifica de la Generalitat Valenciana (PROMETEO/2020/043), by the National Science Foundation under Grants CMMI-1762553 and CMMI-2011280, and by the National Institutes of Health under Grant No. 1R01HL143450-01.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Unipolar Electrogram Eigenvalue Distribution Analysis for the Identification of Atrial Fibrosis

  • Riccio, Jennifer
  • Rocher-Ventura, Sara
  • Martínez-Mateu, Laura
  • Alcaine, Alejandro
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrosis plays an important role in the pathogenesis of atrial fibrillation (AF). Low bipolar electrograms (b-EGMs) peak-to-peak voltage areas indicate scar tissue and are considered targets for AF substrate ablation. However, this approach ignores the spatiotemporal information embedded in the signal and the dependence of b-EGMs on catheter orientation. This work proposes an approach to detect fibrosis based on the eigenvalue dominance ratio (EIGDR) in an ensemble (clique) of unipolar electrograms (u-EGMs). A 2-D tissue with a central circular patch of fibrosis has been simulated using the Courtemanche cellular model. Maps of EIGDR have been computed using two sizes of electrode cliques, from the original u-EGMs within the ensemble or after a time alignment of these signals. Performance of each map in detecting fibrosis has been evaluated using receiver operating characteristic curves and detection accuracy. Best results achieve an area under the curve (AUC) of 0.98 and an accuracy (ACC) of 1 when we use as marker the gain in eigenvalue dominance produced by the ensemble alignment, Funding comes from EU Programme H2020 under the Marie Sklodowska-Curie Grant No 766082 (MY-ATRIA), Gobierno de Aragon (BSICoS Group T39-20R) cofunded by FEDER 2014-2020 "Building Europe from Aragon", fellowship ACIF/2018/174 from Generalitat Valenciana, and PID2019-104881RB-I00 from MICINN, Spain
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of genetic mutations to atria vulnerability to atrial fibrillation: An in-silico 3D human atria study

  • Belletti, Rebecca
  • Osca, Joaquín
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Background and Objective: Personalized 3D computer models of atria have been extensively implemented in the last yearsas a tool to facilitate the understanding of the mechanisms underlying different forms of arrhythmia, such as atrial fibrillation (AF). Meanwhile, genetic mutations acting on potassium channel dynamics were demonstrated to induce fibrillatory episodes in asymptomatic patients. This research study aims at assessing the effects and the atrial susceptibility to AF of three gain-of-function mutations ¿ namely, KCNH2 T895M, KCNH2 T436M, and KCNE3-V17M ¿ associated with AF outbreaks, using highly detailed 3D atrial models with realistic wall thickness and heterogenous histological properties. Methods: The 3D atrial model was generated by reconstructing segmented anatomical structures from CT scans of an AF patient. Modified versions of the Courtemanche human atrial myocyte model were used to reproduce the electrophysiological activity of the WT and of the three mutant cells. Ectopic foci (EF) were simulated in sixteen locations across the atrial mesh using an S1-S2 protocol with two S2 basic cycle lengths (BCL) and eleven coupling intervals in order to induce arrhythmias. Results: The three genetic mutations at 3D level reduced the APD90. The KCNE3-V17M mutation provoked the highest shortening (55 % in RA and LA with respect to WT), followed by KCNH2 T895M (14 % in RA and 18 % LA with respect to WT)and KCNH2 T436M (7 % in RA and 9 % LA with respect to WT). The KCNE3-V17M mutation led to arrhythmia in 67 % of the cases simulated and in 94 % of ectopic foci considered, at S2 BCL equal to 100 ms. The KCNH2 T436M and KCNH2 T895M mutations increased the vulnerability to AF in a similar way, leading to arrhythmic episodes in 7 % of the simulated conditions, at S2 BCL set to 160 ms. Overall, 60 % of the arrhythmic events generated arise in the left atrium. Spiral waves, multiple rotors and disordered electrical pattern were elicited in the presence of the KCNE3-V17M mutation, exhibiting an instantaneous mean frequency of 7.6 Hz with a mean standard deviation of 1.12 Hz. The scroll waves induced in the presence of the KCNH2 T436M and KCNH2 T895M mutations showed steadiness and regularity with an instantaneous mean frequencies in the range of 4.9 ¿ 5.1 Hz and a mean standard deviation within 0.19 ¿ 0.53 Hz. Conclusions: The pro-arrhythmogenicity of the KCNE3-V17M, KCNH2 T895M and KCNH2 T436M mutations was studied and proved on personalized 3D cardiac models. The three genetic mutations were demonstrated to increase the predisposition of atrial tissue to the formation of AF-susceptible substrate in different ways based on their effects on electrophysiological properties of the atria., This work was supported by the European Union s Horizon 2020 research and innovation program under the Marie Skodowska-Curie gran agreement No. 766082 (MY-ATRIA project), by the Direccion General de Política Científica de la Generalitat Valenciana (PROMETEO/2020/043) and was partially funded by grant PID2022-140553OB-C41 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher, Sara
  • Martínez-Mateu, Laura
  • Invers-Rubio, Eric
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Atrial fibrosis plays a key role in the initiation and progression of atrial fibrillation (AF). Atrial fibrosis is typically identified by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fibrosis. A simulated 2D tissue with a fibrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and R-A, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, Delta R-A. The performance of each map in detecting fibrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by R-A, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fibrotic and non- fibrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fibrosis markers, encouraging further studies to confirm their translation to clinical settings., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 766082 and No. 860974, by projects PID2019-105674RBI00, PID2019-104881RB-I00 (MICINN) and Aragon Government (Reference Group Biomedical Signal Interpretation and Computational Simulation (BSICoS) T39-20R) cofunded by FEDER 20142020 "Building Europe from Aragon", by fellowship ACIF/2018/174 and Grant PROMETEO/2020/043, both from Direccion General de Politica Cientifica de la Generalitat Valenciana, and by DENIS Project (Volunteer Computer platform) supported through CoMBA 2021-2022 internal projects call from Universidad San Jorge.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Using Machine Learning to Characterize Atrial Fibrotic Substrate from Intracardiac Signals with a Hybrid in silico and in vivo Dataset

  • Sánchez-Arciniegas, Jorge Patricio
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Luongo, Giorgio
  • Nothstein, Mark
  • Unger, Laura A.
  • Luik, Armin
  • Doessel, Olaf
  • Loewe, Axel
[EN] In patients with atrial fibrillation, intracardiac electrogram signal amplitude is known to decrease with increased structural tissue remodeling, referred to as fibrosis. In addition to the isolation of the pulmonary veins, fibrotic sites are considered a suitable target for catheter ablation. However, it remains an open challenge to find fibrotic areas and to differentiate their density and transmurality. This study aims to identify the volume fraction and transmurality of fibrosis in the atrial substrate. Simulated cardiac electrograms, combined with a generalized model of clinical noise, reproduce clinically measured signals. Our hybrid dataset approach combines in silico and clinical electrograms to train a decision tree classifier to characterize the fibrotic atrial substrate. This approach captures different in vivo dynamics of the electrical propagation reflected on healthy electrogram morphology and synergistically combines it with synthetic fibrotic electrograms from in silico experiments. The machine learning algorithm was tested on five patients and compared against clinical voltage maps as a proof of concept, distinguishing non-fibrotic from fibrotic tissue and characterizing the patient's fibrotic tissue in terms of density and transmurality. The proposed approach can be used to overcome a single voltage cut-off value to identify fibrotic tissue and guide ablation targeting fibrotic areas., We gratefully acknowledge financial support by the Deutsche Forschungsgemeinschaft (DFG) through DO637/22-3, LO2093/1-1 and LU 2294/1-1, by the European Union's Horizon 2020 programme (grant agreement No.766082, MY-ATRIA project), by the KIT-Publication Fund of the Karlsruhe Institute of Technology and by the Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2017-2020 from the Ministerio de Ciencia e Innovacion y Universidades (PID2019-104356RB-C41/AEI/10.13039/501100011033)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Omnipolar EGM Voltage Mapping for Atrial Fibrosis Identification Evaluated with an Electrophysiological Model

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher-Ventura, Sara
  • Laguna, Pablo
  • Martínez, Juan Pablo
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrillation (AF) is the most spread heart arrhythmia, whose mechanisms are not completely clear yet. Catheter ablation is a standard treatment, which isolates the area involved in the arrhythmia. Intracardiac electrograms (EGMs) are used to better understand the AF mechanisms and to find appropriate ablation sites. Bipolar EGMs (b-EGMs) are often employed, but their amplitude and shape depend on catheter orientation, limiting reliability. To avoid this uncertainty, an approach insensitive to catheter orientation, referred as Omnipolar EGM (OP-EGM) method, has been introduced, which uses an estimation of the electric field within a group of electrodes, referred as clique. In this work, we compare different mapping approaches based on b-EGMs and OPEGM signals in simulation including fibrosis, so to evaluate their ability to detect fibrosis and reproduce the spatial distribution of the voltage. Maps have been computed using two clique configurations (square and triangular), introducing or not a previous time alignment of the bEGMs. OP-EGM signals have been obtained by projecting the electric field along directions of its maximal excursion and its principal components. Results show that both cliques configurations present good performance, in terms of fibrosis detection and correlation with the reference voltage maps. In addition, the proposed alignment of b-EGMS improves maps based on OP-EGM signals, especially when square cliques are used., This work is part of a project that has received funding from the European Union¿s Horizon 2020 research and innovation program under the Marie Sk¿odowska-Curie grant agreement No 766082 (MY-ATRIA).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Arrhythmogenicity quantification of two genetic defects affecting IKr channel in AF patients

  • Belletti, R.
  • Martínez Mateu, L.
  • Cherry, E.
  • Fenton, F. H.
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Atrial fibrillation (AF) is the most common cardiac arrhythmia characterized by disorganized electrical activations of the upper chambers of the heart, leading to uncoordinated contraction and compromising the pumping action of the organ. AF risk factors include cardiovascular pathologies, endocrine disorders, advanced age, obesity, smoking and heritability. Genetic mutations affecting gene encoding for ion channel protein structures are in fact considered as cause of fibrillatory events in individuals who do not present any other co-morbidities. In this work, two genetic mutations found in literature and affecting the alpha-subunit of the rapid delayed rectifier potassium channel are modelled, by reparametrizing the IKr current formulation and by fitting it to mutant experimental data. The modified potassium current was then incorporated into the Courtemanche-Ramirez-Nattel (CRN) model and single cell simulations have been performed to study the mutations¿ effects on action potential and current traces, as well as, restitution properties, in right and left atrium. Both mutations produced a shortening of the action potential duration at 90% of repolarization (APD90), a higher current peak and lower APD values in the restitution curves. T895M yielded also to a reduction in the maximum slope of restitution curve. Tissue patch simulations revealed that T895M and T436M provide a substrate to initiate and maintain re-entries during the 5 seconds of simulation. Rotor¿s meandering in T895M appears more stable with a less extended area and more regular pattern than in T436M. Investigation on 3D atria and torso models will be necessary to provide further insights in understanding the mechanisms behind these genetic mutations., I am grateful to the teams at GaTech, who helped me in the realization of this work. This project has been funded by the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie gran agreement No.766082 and by Generalitat Valenciana, Prometeo programme 2020/043.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Simulation Study of the Arrhythmogenic Effects of Two Missense Mutations in Human Atrial Fibrillation

  • Belletti, Rebecca
  • Martínez-Mateu, Laura
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Genetic mutations affecting genes encoding for ion channel protein structures have been associated with the presence of atrial fibrillation (AF) in healthy individuals. The aim of this study is to model and simulate the effects of two gain-of-function mutations found in literature, T895M and T436M, and affecting the rapid delayed rectifier potassium current. Courtemanche human atrial model has been chosen to reproduce myocytes behaviour and an optimization algorithm has been employed to fit model parameters to experimental data. Single cell and tissue patch simulations have been performed to study the effects of the two mutations in control, paroxysmal and permanent AF conditions, both in right and left atrium. 0D simulations revealed that both mutations cause an increase in IKr current, leading to action potential duration shortening and flattening of restitution curves, especially in presence of the mutation T895M. Initiation of a re-entrant activity in 2D simulations were possible both in case of T895M and T436M. The study reports the arrhythmogenicity of the two mutants and reveals T895M having a stronger effect with respect to T436M, in particular in control rather than in paroxysmal and permanent AF conditions. Differences in the dynamics of the two mutations highlight the importance of a patient-specific approach in planning targeted drug therapies., I acknowledge this work to the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie gran agreement No.766082 and to Generalitat Valenciana, Prometeo programme 2020/043
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Characterization of Propagation Patterns with Omnipolar EGM in Epicardial Multi-Electrode Arrays

  • Riccio, J.
  • Alcaine, A.
  • De Groot, N.M.S.
  • Houben, R.
  • Laguna, P.
  • Martínez, J.P.
Omnipolar Electrogram (OP-EGM) is a recently proposed technique to characterize myocardial propagation in multi-electrode catheters regardless of the angle between propagation direction and catheter bipolar. This work aims to evaluate the accuracy of atrial propagation parameters obtained with OP-EGM in sinus rhythm (SR) and in different patterns of atrial fibrillation (AF).Real and simulated unipolar electrograms (u-EGMs) were used in this study. For both types of data, conduction velocity was obtained for each clique of 4 neighbour electrodes using OP-EGM. As a reference, conduction velocity was also computed from local activation times (LATs) using a linear propagation model.Analysis of simulated data showed that conduction velocity had good concordance with propagation patterns for both estimations, although the LAT-based errors were lower in most of the cases. When conduction velocity magnitude (CV) was 1 mm/ms, its estimation errors (expressed as mean ± std) calculated with OP-EGM and from LATs were 0.053 ± 0.005 mm/ms and 0.003 ±2.1 ×10-5 mm/ms, respectively, when focus was at 30 mm from the bottom of the tissue slice, while propagation direction angular errors were 6.64 ± 4.3°and 4.35 ± 2.8°. In real data, maps obtained with OP-EGM presented smoother and more coherent patterns than those based on LATs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The ''Digital Twin'' to enable the vision of precision cardiology

  • Corral-Acero, J.
  • Margara, F.
  • Marciniak, M.
  • Rodero, C.
  • Loncaric, F.
  • Feng, Y.
  • Gilbert, A.
  • Fernandes, J.F.
  • Bukhari, H.A.
  • Wajdan, A.
  • Martinez, M.V.
  • Santos, M.S.
  • Shamohammdi, M.
  • Luo, H.
  • Westphal, P.
  • Leeson, P.
  • DiAchille, P.
  • Gurev, V.
  • Mayr, M.
  • Geris, L.
  • Pathmanathan, P.
  • Morrison, T.
  • Cornelussen, R.
  • Prinzen, F.
  • Delhaas, T.
  • Doltra, A.
  • Sitges, M.
  • Vigmond, E.J.
  • Zacur, E.
  • Grau, V.
  • Rodriguez, B.
  • Remme, E.W.
  • Niederer, S.
  • Mortier, P.
  • McLeod, K.
  • Potse, M.
  • Pueyo, E.
  • Bueno-Orovio, A.
  • Lamata, P.
Providing therapies tailored to each patient is the vision of precision medicine, enabled by the increasing ability to capture extensive data about individual patients. In this position paper, we argue that the second enabling pillar towards this vision is the increasing power of computers and algorithms to learn, reason, and build the ''digital twin'' of a patient. Computational models are boosting the capacity to draw diagnosis and prognosis, and future treatments will be tailored not only to current health status and data, but also to an accurate projection of the pathways to restore health by model predictions. The early steps of the digital twin in the area of cardiovascular medicine are reviewed in this article, together with a discussion of the challenges and opportunities ahead. We emphasize the synergies between mechanistic and statistical models in accelerating cardiovascular research and enabling the vision of precision medicine.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Omnipolar EGM voltage mapping for atrial fibrosis identification evaluated with an electrophysiological model

  • Riccio, J.
  • Alcaine, A.
  • Rocher, S.
  • Laguna, P.
  • Saiz, J.
  • Martínez, J.P.
Atrial fibrillation (AF) is the most spread heart arrhythmia, whose mechanisms are not completely clear yet. Catheter ablation is a standard treatment, which isolates the area involved in the arrhythmia. Intracardiac electrograms (EGMs) are used to better understand the AF mechanisms and to find appropriate ablation sites. Bipolar EGMs (b-EGMs) are often employed, but their amplitude and shape depend on catheter orientation, limiting reliability. To avoid this uncertainty, an approach insensitive to catheter orientation, referred as Omnipolar EGM (OP-EGM) method, has been introduced, which uses an estimation of the electric field within a group of electrodes, referred as clique. In this work, we compare different mapping approaches based on b-EGMs and OP-EGM signals in simulation including fibrosis, so to evaluate their ability to detect fibrosis and reproduce the spatial distribution of the voltage. Maps have been computed using two clique configurations (square and triangular), introducing or not a previous time alignment of the b-EGMs. OP-EGM signals have been obtained by projecting the electric field along directions of its maximal excursion and its principal components. Results show that the proposed alignment of b-EGMs improves maps based on OP-EGM signals. Both cliques configurations present good performance, in terms of fibrosis detection and correlation with the reference voltage maps.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Unipolar Electrogram Eigenvalue Distribution Analysis for the Identification of Atrial Fibrosis

  • Riccio, Jennifer
  • Rocher Ventura, Sara
  • Martínez Mateu, Laura
  • Alcaine Otín, Alejandro
  • Sáiz Rodríguez, Javier
  • Martínez Cortés, Juan Pablo
  • Laguna Lasaosa, Pablo
Atrial fibrosis plays an important role in the pathogenesis of atrial fibrillation (AF). Low bipolar electrograms (b-EGMs) peak-to-peak voltage areas indicate scar tissue and are considered targets for AF substrate ablation. However, this approach ignores the spatiotemporal information embedded in the signal and the dependence of b-EGMs on catheter orientation. This work proposes an approach to detect fibrosis based on the eigenvalue dominance ratio (EIGDR) in an ensemble (clique) of unipolar electrograms (u-EGMs). A 2-D tissue with a central circular patch of fibrosis has been simulated using the Courtemanche cellular model. Maps of EIGDR have been computed using two sizes of electrode cliques, from the original u-EGMs within the ensemble or after a time alignment of these signals. Performance of each map in detecting fibrosis has been evaluated using receiver operating characteristic curves and detection accuracy. Best results achieve an area under the curve (AUC) of 0.98 and an accuracy (ACC) of 1 when we use as marker the gain in eigenvalue dominance produced by the ensemble alignment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Relationship between Atrial Oscillatory Acetylcholine Release Pattern and f-wave Frequency Modulation: a Computational and Experimental Study

  • Celotto, Chiara
  • Sánchez Tapia, Carlos
  • Mountris, Konstantinos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Laguna Lasaosa, Pablo
  • Pueyo Paúles, Esther
The frequency of fibrillatory waves (f-waves), F f , exhibits significant variation over time, and previous studies suggest that some of this variation is related to respiratory modulation through the autonomic nervous system. In this study, we tested the hypothesis that this variation (ΔF f ) could be related to acetylcholine concentration ([ACh]) release pattern. Electrocardiograms were recorded from seven patients during controlled respiration before and after full vagal blockade, from which f-wave frequency modulation was characterized. Computational simulations in human atrial tissues were performed to assess the effects of [ACh] release pattern on F f and compared to experimental results in humans. A cross-stimulation protocol was applied onto the tissue to initiate a rotor while cyclically varying [ACh] following a sinusoidal waveform of frequency equal to 0.125 Hz. Different mean levels (0.05, 0.075μM/l) and peak-to-peak ranges (0.1, 0.05, 0.025 μM/l) of [ACh] variation were tested. In all patients, an f-wave frequency modulation could be observed. In 57% of the patients, this modulation was significantly reduced after vagal blockade. Simulations confirmed that rotor frequency variations followed the induced [ACh] patterns. Mean F f was dependent on mean [ACh] level, whileΔF f was dependent on [ACh] variation range.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Machine Learning to Find Areas of Rotors Sustaining Atrial Fibrillation from the ECG

  • Luongo, Giorgio
  • Azzolin, Luca
  • Rivolta, Massimo Walter
  • Paggi de Almeida, Tiago
  • Martínez, Juan Pablo
  • Coutinho Soriano, Diogo
  • Doessel, Olaf
  • Sassi, Roberto
  • Laguna Lasaosa, Pablo
  • Loewe, Axel
Atrial fibrillation (AF) is the most frequent irregular heart rhythm due to disorganized atrial electrical activity, often sustained by rotational drivers called rotors. The non-invasive localization of AF drivers can lead to improved personalized ablation strategy, suggesting pulmonary vein (PV) isolation or more complex extra-PV ablation procedures in case the driver is on other atrial regions. We used a Machine Learning approach to characterize and discriminate simulated single stable rotors (1R) location: PVs, left atrium (LA) excluding the PVs, and right atrium (RA), utilizing solely non-invasive signals (i.e., the 12-lead ECG). 1R episodes sustaining AF were simulated. 128 features were extracted from the signals. Greedy forward algorithm was implemented to select the best feature set which was fed to a decision tree classifier with hold-out cross-validation technique. All tested features showed significant discriminatory power, especially those based on recurrence quantification analysis (up to 80.9% accuracy with single feature classification). The decision tree classifier achieved 89.4% test accuracy with 18 features on simulated data, with sensitivities of 93.0%, 82.4%, and 83.3% for RA, LA, and PV classes, respectively. Our results show that a machine learning approach can potentially identify the location of 1R sustaining AF using the 12-lead ECG.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Non-Invasive Identification of Atrial Fibrillation Driver Location Using the 12-lead ECG: Pulmonary Vein Rotors vs. other Locations

  • Luongo, Giorgio
  • Azzolin, Luca
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Doessel, Olaf
  • Loewe, Axel
  • Sassi, Roberto
  • Rivolta, Massimo Walter
Atrial fibrillation (AF) is an irregular heart rhythm due to disorganized atrial electrical activity, often sustained by rotational drivers called rotors. In the present work, we sought to characterize and discriminate whether simulated single stable rotors are located in the pulmonary veins (PVs) or not, only by using non-invasive signals (i.e., the 12-lead ECG). Several features have been extracted from the signals, such as Hjort descriptors, recurrence quantification analysis (RQA), and principal component analysis. All the extracted features have shown significant discriminatory power, with particular emphasis to the RQA parameters. A decision tree classifier achieved 98.48% accuracy, 83.33% sensitivity, and 100% specificity on simulated data.Clinical Relevance-This study might guide ablation procedures, suggesting doctors to proceed directly in some patients with a pulmonary veins isolation, and avoiding the prior use of an invasive atrial mapping system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

SK Channel Block and Adrenergic Stimulation Counteract Acetylcholine-Induced Arrhythmogenic Effects in Human Atria

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
There is increasing evidence on the role of the autonomic nervous system in the pathogenesis of atrial fibrillation. Interventions targeting autonomic modulation of atrial electrical activity have been shown to reduce the incidence of atrial arrhythmias. Additionally, recent investigations have proved that pharmacological therapies inhibiting small-conductance calcium-activated potassium (SK) channels are able to lessen cholinergic effects in the atria.In this study we use computational modeling and simulation to test individual and combined effects of SK channel block and adrenergic stimulation in counteracting detrimental effects induced by the parasympathetic neurotransmitter acetylcholine (ACh) on human atrial electrophysiology. Cell and tissue models are built that incorporate descriptions of SK channels as well as of isoproterenol (Iso)- and ACh-mediated regulation of the atrial action potential (AP). Three different cellular AP models, representing a range of physiological AP shapes, are considered and both homogeneous and heterogeneous ACh distributions in atrial tissue are simulated.At the cellular level, SK channel block is demonstrated to partially revert shortening of AP duration (APD) mediated by ACh at various doses, whereas 1 µM Iso has a variable response depending on the AP shape. The combination of SK block and Iso is in all cases able to take APD back to baseline levels, recovering between 82% and 120% of the APD shortening induced by 0.1 µM ACh. At the tissue level, SK block and Iso alone or in combination do not exert remarkable effects on conduction velocity, but the combination of the two is able to notably prolong the ACh-mediated APD shortening, thus increasing the wavelength for reentry.In conclusion, the results from this study support the combination of SK channel block and adrenergic stimulation as a potential option to counteract parasympathetically-mediated proarrhythmic effects in the human atria.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Location of parasympathetic innervation regions from electrograms to guide atrial fibrillation ablation therapy: an in silico modeling study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
The autonomic nervous system (ANS) plays an essential role in the generation and maintenance of cardiac arrhythmias. The cardiac ANS can be divided into its extrinsic and intrinsic components, with the latter being organized in an epicardial neural network of interconnecting axons and clusters of autonomic ganglia called ganglionated plexi (GPs). GP ablation has been associated with a decreased risk of atrial fibrillation (AF) recurrence, but the accurate location of GPs is required for ablation to be effective. Although GP stimulation triggers both sympathetic and parasympathetic ANS branches, a predominance of parasympathetic activity has been shown. This study aims was to develop a method to locate atrial parasympathetic innervation sites based on measurements from a grid of electrograms (EGMs). Electrophysiological models representative of non-AF, paroxysmal AF (PxAF), and persistent AF (PsAF) tissues were developed. Parasympathetic effects were modeled by increasing the concentration of the neurotransmitter acetylcholine (ACh) in randomly distributed circles across the tissue. Different circle sizes of ACh and fibrosis geometries were considered, accounting for both uniform diffuse and non-uniform diffuse fibrosis. Computational simulations were performed, from which unipolar EGMs were computed in a 16 × 1 6 electrode mesh. Different distances of the electrodes to the tissue (0.5, 1, and 2 mm) and noise levels with signal-to-noise ratio (SNR) values of 0, 5, 10, 15, and 20 dB were tested. The amplitude of the atrial EGM repolarization wave was found to be representative of the presence or absence of ACh release sites, with larger positive amplitudes indicating that the electrode was placed over an ACh region. Statistical analysis was performed to identify the optimal thresholds for the identification of ACh sites. In all non-AF, PxAF, and PsAF tissues, the repolarization amplitude rendered successful identification. The algorithm performed better in the absence of fibrosis or when fibrosis was uniformly diffuse, with a mean accuracy of 0.94 in contrast with a mean accuracy of 0.89 for non-uniform diffuse fibrotic cases. The algorithm was robust against noise and worked for the tested ranges of electrode-to-tissue distance. In conclusion, the results from this study support the feasibility to locate atrial parasympathetic innervation sites from the amplitude of repolarization wave.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Characterization of Atrial Propagation Patterns and Fibrotic Substrate With a Modified Omnipolar Electrogram Strategy in Multi-Electrode Arrays

  • Riccio, J
  • Alcaine, A
  • Rocher, S
  • Martinez-Mateu, L
  • Laranjo, S
  • Saiz, J
  • Laguna, P
  • Martinez, JP
Introduction: The omnipolar electrogram method was recently proposed to try to generate orientation-independent electrograms. It estimates the electric field from the bipolar electrograms of a clique, under the assumption of locally plane and homogeneous propagation. The local electric field evolution over time describes a loop trajectory from which omnipolar signals in the propagation direction, substrate and propagation features, are derived. In this work, we propose substrate and conduction velocity mapping modalities based on a modified version of the omnipolar electrogram method, which aims to reduce orientation-dependent residual components in the standard approach.</p> & nbsp;</p> Methods: A simulated electrical propagation in 2D, with a tissue including a circular patch of diffuse fibrosis, was used for validation. Unipolar electrograms were calculated in a multi-electrode array, also deriving bipolar electrograms along the two main directions of the grid. Simulated bipolar electrograms were also contaminated with real noise, to assess the robustness of the mapping strategies against noise. The performance of the maps in identifying fibrosis and in reproducing unipolar reference voltage maps was evaluated. Bipolar voltage maps were also considered for performance comparison.</p> & nbsp;</p> Results: Results show that the modified omnipolar mapping strategies are more accurate and robust against noise than bipolar and standard omnipolar maps in fibrosis detection (accuracies higher than 85 vs. 80% and 70%, respectively). They present better correlation with unipolar reference voltage maps than bipolar and original omnipolar maps (Pearson''s correlations higher than 0.75 vs. 0.60 and 0.70, respectively).</p> & nbsp;</p> Conclusion: The modified omnipolar method improves fibrosis detection, characterization of substrate and propagation, also reducing the residual sensitivity to directionality over the standard approach and improving robustness against noise. Nevertheless, studies with real electrograms will elucidate its impact in catheter ablation interventions.</p>
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Machine learning enables noninvasive prediction of atrial fibrillation driver location and acute pulmonary vein ablation success using the 12-lead ECG

  • Luongo, Giorgio
  • Azzolin, Luca
  • Schuler, Steffen
  • Rivolta, Massimo W.
  • Almeida, Tiago P.
  • Martínez, Juan P.
  • Soriano, Diogo C.
  • Luik, Armin
  • Müller-Edenborn, Björn
  • Jadidi, Amir
  • Dössel, Olaf
  • Sassi, Roberto
  • Laguna, Pablo
  • Loewe, Axel
Background: Atrial fibrillation (AF) is the most common supraventricular arrhythmia, characterized by disorganized atrial electrical activity, maintained by localized arrhythmogenic atrial drivers. Pulmonary vein isolation (PVI) allows to exclude PV-related drivers. However, PVI is less effective in patients with additional extra-PV arrhythmogenic drivers. Objectives: To discriminate whether AF drivers are located near the PVs vs extra-PV regions using the noninvasive 12-lead electrocardiogram (ECG) in a computational and clinical framework, and to computationally predict the acute success of PVI in these cohorts of data. Methods: AF drivers were induced in 2 computerized atrial models and combined with 8 torso models, resulting in 1128 12-lead ECGs (80 ECGs with AF drivers located in the PVs and 1048 in extra-PV areas). A total of 103 features were extracted from the signals. Binary decision tree classifier was trained on the simulated data and evaluated using hold-out cross-validation. The PVs were subsequently isolated in the models to assess PVI success. Finally, the classifier was tested on a clinical dataset (46 patients: 23 PV-dependent AF and 23 with additional extra-PV sources). Results: The classifier yielded 82.6% specificity and 73.9% sensitivity for detecting PV drivers on the clinical data. Consistency analysis on the 46 patients resulted in 93.5% results match. Applying PVI on the simulated AF cases terminated AF in 100% of the cases in the PV class. Conclusion: Machine learning–based classification of 12-lead-ECG allows discrimination between patients with PV drivers vs those with extra-PV drivers of AF. The novel algorithm may aid to identify patients with high acute success rates to PVI.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Editorial: Atrial Fibrillation: Technology for Diagnosis, Monitoring, and Treatment

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Atrial fibrosis identification with unipolar electrogram eigenvalue distribution analysis in multi-electrode arrays

  • Riccio, Jennifer
  • Alcaine, Alejandro
  • Rocher, Sara
  • Martinez-Mateu, Laura
  • Saiz, Javier
  • Invers-Rubio, Eric
  • Guillem, Maria S.
  • Martínez, Juan Pablo
  • Laguna, Pablo
Atrial fbrosis plays a key role in the initiation and progression of atrial fbrillation (AF). Atrial fbrosis is typically identifed by a peak-to-peak amplitude of bipolar electrograms (b-EGMs) lower than 0.5 mV, which may be considered as ablation targets. Nevertheless, this approach disregards signal spatiotemporal information and b-EGM sensitivity to catheter orientation. To overcome these limitations, we propose the dominant-to-remaining eigenvalue dominance ratio (EIGDR) of unipolar electrograms (u-EGMs) within neighbor electrode cliques as a waveform dispersion measure, hypothesizing that it is correlated with the presence of fbrosis. A simulated 2D tissue with a fbrosis patch was used for validation. We computed EIGDR maps from both original and time-aligned u-EGMs, denoted as R and RA, respectively, also mapping the gain in eigenvalue concentration obtained by the alignment, ΔRA. The performance of each map in detecting fbrosis was evaluated in scenarios including noise and variable electrode-tissue distance. Best results were achieved by RA, reaching 94% detection accuracy, versus the 86% of b-EGMs voltage maps. The proposed strategy was also tested in real u-EGMs from fbrotic and non-fbrotic areas over 3D electroanatomical maps, supporting the ability of the EIGDRs as fbrosis markers, encouraging further studies to confrm their translation to clinical settings.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Atrial fibrillation episode patterns as predictor of clinical outcome of catheter ablation

  • Saiz Vivó, Javier
  • Corino, Valentina D. A.
  • Martín Yebra, Alba
  • Mainardi, Luca T.
  • Hatala, Robert
  • Sörnmo, Leif
Methods for characterization of atrial fibrillation (AF) episode patterns have been introduced without establishing clinical significance. This study investigates, for the first time, whether post-ablation recurrence of AF can be predicted by evaluating episode patterns. The dataset comprises of 54 patients (age 56 ± 11 years; 67% men), with an implantable cardiac monitor, before undergoing the first AF catheter ablation. Two parameters of the alternating bivariate Hawkes model were used to characterize the pattern: AF dominance during the monitoring period (log(mu)) and temporal aggregation of episodes (beta1). Moreover, AF burden and AF density, a parameter characterizing aggregation of AF burden, were studied. The four parameters were computed from an average of 29 AF episodes before ablation. The risk of AF recurrence after catheter ablation using the Hawkes parameters log(mu) and beta1, AF burden, and AF density was evaluated. While the combination of AF burden and AF density is related to a non-significant hazard ratio, the combination of log(mu) and beta1 is related to a hazard ratio of 1.95 (1.03–3.70; p < 0.05). The Hawkes parameters showed increased risk of AF recurrence within 1 year after the procedure for patients with high AF dominance and high episode aggregation and may be used for pre-ablation risk assessment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Steady-state and transient effects of SK channel block and adrenergic stimulation to counteract acetylcholine-induced arrhythmogenic effects in the human atria: a computational study

  • Celotto, Ch.
  • Sánchez, C.
  • Mountris, K. A.
  • Laguna, P.
  • Pueyo, E.
Hyperactivity of the parasympathetic nervous system has been linked to the development of paroxysmal atrial fibrillation (AF). The parasympathetic neurotransmitter acetylcholine (ACh) causes a reduction in action potential (AP) duration (APD) and an increase in resting membrane potential (RMP), both of which contribute to enhance the risk for reentry. Research suggests that small-conductance calcium activated potassium (SK) channels may be an effective target for treating AF. Therapies targeting the autonomic nervous system, either alone or in combination with other drugs, have been explored and have been shown to decrease the incidence of atrial arrhythmias. This study uses computational modeling and simulation to examine the impact of SK channel block (SKb) and-adrenergic stimulation through Isoproterenol (Iso) on countering the negative effects of cholinergic activity in human atrial cell and 2D tissue models. The steady-state effects of Iso and/or SKb on AP shape, APD at 90% repolarization (APD90) and RMP were evaluated. The ability to terminate stable rotational activity in cholinergically-stimulated 2D tissue models of AF was also investigated. A range of SKb and Iso application kinetics, which reflect varying drug binding rates, were taken into consideration. The results showed that SKb alone prolonged APD90 and was able to stop sustained rotors in the presence of ACh concentrations up to 0.01 M. Iso terminated rotors under all tested ACh concentrations, but resulted in highly-variable steady-state outcomes depending on baseline AP morphology. Importantly, the combination of SKb and Iso resulted in greater APD90 prolongation and showed promising anti-arrhythmic potential by stopping stable rotors and preventing re-inducibility.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Editorial: Atrial Fibrillation: Technologies for Investigation, Monitoring and Treatment, Volume II

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The frequency of atrial fibrillatory waves is modulated by the spatiotemporal pattern of acetylcholine release: a 3D computational study

  • Celotto, Chiara
  • Sánchez, Carlos
  • Abdollahpur, Mostafa
  • Sandberg, Frida
  • Rodriguez Matas, Jose F.
  • Laguna, Pablo
  • Pueyo, Esther
In atrial fibrillation (AF), the ECG P-wave, which represents atrial depolarization, is replaced with chaotic and irregular fibrillation waves (f waves). The f-wave frequency, Ff, shows significant variations over time. Cardiorespiratory interactions regulated by the autonomic nervous system have been suggested to play a role in such variations. We conducted a simulation study to test whether the spatiotemporal release pattern of the parasympathetic neurotransmitter acetylcholine (ACh) modulates the frequency of atrial reentrant circuits. Understanding parasympathetic involvement in AF may guide more effective treatment approaches and could help to design autonomic markers alternative to heart rate variability (HRV), which is not available in AF patients. 2D tissue and 3D whole-atria models of human atrial electrophysiology in persistent AF were built. Different ACh release percentages (8% and 30%) and spatial ACh release patterns, including spatially random release and release from ganglionated plexi (GPs) and associated nerves, were considered. The temporal pattern of ACh release, ACh(t), was simulated following a sinusoidal waveform of frequency 0.125 Hz to represent the respiratory frequency. Different mean concentrations (ACh̄) and peak-to-peak ranges of ACh (ΔACh) were tested. We found that temporal variations in Ff, Ff(t), followed the simulated temporal ACh(t) pattern in all cases. The temporal mean of Ff(t), F̄f, depended on the fibrillatory pattern (number and location of rotors), the percentage of ACh release nodes and ACh̄. The magnitude of Ff(t) modulation, ΔFf, depended on the percentage of ACh release nodes and ΔACh. The spatial pattern of ACh release did not have an impact on F̄f and only a mild impact on ΔFf. The f-wave frequency, being indicative of vagal activity, has the potential to drive autonomic-based therapeutic actions and could replace HRV markers not quantifiable from AF patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Tilt-induced changes in f-wave characteristics during atrial fibrillation: an experimental and computational investigation

  • Abdollahpur, Mostafa
  • Celotto, Chiara
  • Sánchez, Carlos
  • Plappert, Félix
  • Östenson, Sten
  • Platonov, Pyotr G.
  • Laguna, Pablo
  • Pueyo, Esther
  • Sandberg, Frida
Introduction This study explores transient and stationary effects of sympathetic and parasympathetic stimulation on f-wave characteristics in atrial fibrillation (AF) patients undergoing a tilt test. Transient phase is defined as the initial 2-minute interval following each postural change, reflecting immediate autonomic adaptation, whereas steady phase refers to the subsequent interval (from 3 minutes post-change until phase end) representing a stable autonomic state. Methods Our primary aim is to investigate how the two branches of the autonomic nervous system (ANS) influence the f-wave frequency time series (f(m)). An analysis of f(m) in terms of the mean over time (Ff) and the magnitude of respiration-modulated f(m) variations (ΔFf) is conducted during baseline supine rest (B), head-down tilt (HDT) and head-up tilt (HUT). We analyzed data from a previous study in which 24 patients with persistent AF underwent a tilt test protocol, during which electrocardiograms (ECGs) were recorded. A model-based method was used to extract f(m) series from the ECG. Subsequently, an orthogonal subspace projection method was employed to quantify ΔFf, considering an ECG-derived respiratory signal. Electrophysiological computational simulations were conducted on 2D and 3D human atrial persistent AF models to aid the interpretation of clinical findings. Various levels of cholinergic stimulation by acetylcholine and β-adrenergic stimulation by isoproterenol were tested in the models. The temporal modulation of acetylcholine, representing changes associated with respiration, was cyclically modeled using sinusoidal waveforms. Results Analysis of the clinical data showed a decrease in Ff from B to HDT and an increase from HDT to HUT. During HDT, ΔFf initially increased in the transient phase before decreasing in the steady phase, then rose again during HUT. Analysis of the simulated data showed that increasing the concentration of Isoproterenol and/or acetylcholine resulted in a rise in Ff. Additionally, the magnitude of ΔFf was shown to be associated with the extent of acetylcholine fluctuation. Discussion These results suggest that changes in f-wave frequency characteristics during HUT and HDT could be linked to changes in sympathetic activity, with parasympathetic activity possibly modulating the effects of sympathetic activity rather than being an independent driver of fibrillatory rate changes.