Skip to main content

MULTI-SCALE PHYSIOLOGY-DRIVEN COMPUTATIONAL TOOLS TO ASSIST IN THE ASSESSMENT AND MANAGEMENT OF CARDIAC DYSFUNCTIONS

DPI2016-75458-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 42
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Automatic activation mapping and origin identification of idiopathic outflow tract ventricular arrhythmias

  • Alcaine, Alejandro
  • Soto-Iglesias, David
  • Acosta, Juan Carlos
  • Korshunov, Viatcheslav
  • Penela, Diego
  • Martínez, Mikel
  • Linhart, Markus
  • Andreu Martínez, David
  • Fernández-Armenta, Juan
  • Laguna, Pablo
  • Martínez, Juan Pablo
  • Camara, Oscar
  • Berruezo Sánchez, Antonio
Purpose: Activation mapping is used to guide ablation of idiopathic outflow tract ventricular arrhythmias (OTVAs). Isochronal activation maps help to predict the site of origin (SOO): left vs right outflow tract (OT). We evaluate an algorithm for automatic activation mapping based on the onset of the bipolar electrogram (EGM) signal for predicting the SOO and the effective ablation site in OTVAs. Methods: Eighteen patients undergoing ablation due to idiopathic OTVAs were studied (12 with left ventricle OT origin). Right ventricle activation maps were obtained offline with an automatic algorithm and compared with manual annotation maps obtained during the intervention. Local activation time (LAT) accuracy was assessed, as well as the performance of the 10 ms earliest activation site (EAS) isochronal area in predicting the SOO. Results: High correlation was observed between manual and automatic LATs (Spearman's: 0.86 and Lin's: 0.85, both p < 0.01). The EAS isochronal area were closely located in both map modalities (5.55 ± 3.56 mm) and at a similar distance from the effective ablation site (0.15 ± 2.08 mm difference, p = 0.859). The 10 ms isochronal area longitudinal/perpendicular diameter ratio measured from automatic maps showed slightly superior SOO identification (67% sensitivity, 100% specificity) compared with manual maps (67% sensitivity, 83% specificity). Conclusions: Automatic activation mapping based on the bipolar EGM onset allows fast, accurate and observer-independent identification of the SOO and characterization of the spreading of the activation wavefront in OTVAs., This study was supported by personal grants to A.A. refs.: BES-2011-046644 and EEBB-I-15-09466, by projects TEC2013-42140-R, DPI2016-75458-R and TIN2011-28067 from Ministerio de Economía y Competitividad. Also by Gobierno de Aragón (Spain) and European Social Fund (EU) through Grupo Consolidado BSICoS ref.: T 96. The CIBER-BBN is an initiative of Instituto de Salud Carlos III. This work was also supported in part by the project PI14/00759, integrated in the Plan Nacional de I + D + i and co-funded by the ISCIII-Subdirección General de Evaluación and the Fondo Europeo de Desarrollo Regional (FEDER).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Automatic detection of slow conducting channels during substrate ablation of scar-related ventricular arrhythmias

  • Alcaine, Alejandro
  • Jáuregui, Beatriz
  • Soto-Iglesias, David
  • Acosta, Juan Carlos
  • Penela, Diego
  • Fernández-Armenta, Juan
  • Linhart, Markus
  • Andreu Martínez, David
  • Mont, Lluís
  • Laguna, Pablo
  • Camara, Oscar
  • Martínez, Juan Pablo
  • Berruezo Sánchez, Antonio
Background. Voltage mapping allows identifying the arrhythmogenic substrate during scar-related ventricular arrhythmia (VA) ablation procedures. Slow conducting channels (SCCs), defined by the presence of electrogram (EGM) signals with delayed components (EGM-DC), are responsible for sustaining VAs and constitute potential ablation targets. However, voltage mapping, as it is currently performed, is time-consuming, requiring a manual analysis of all EGMs to detect SCCs, and its accuracy is limited by electric far-field. We sought to evaluate an algorithm that automatically identifies EGM-DC, classifies mapping points, and creates new voltage maps, named “Slow Conducting Channel Maps” (SCC-Maps). Methods. Retrospective analysis of electroanatomic maps (EAM) from 20 patients (10 ischemic, 10 with arrhythmogenic right ventricular dysplasia/cardiomyopathy) was performed. EAM voltage maps were acquired during sinus rhythm and used for ablation. Preprocedural contrast-enhanced cardiac magnetic resonance (Ce-CMR) imaging was available for the ischemic population. Three mapping modalities were analysed: (i) EAM voltage maps using standard (EAM standard) or manual (EAM screening) thresholds for defining core and border zones; (ii) SCC-Maps derived from the use of the novel SCC-Mapping algorithm that automatically identify EGM-DCs measuring the voltage of the local component; and (iii) Ce-CMR maps (when available). The ability of each mapping modality in identifying SCCs and their agreement was evaluated. Results. SCC-Maps and EAM screening identified a greater number of SCC entrances than EAM standard (3.45 ± 1.61 and 2.95 ± 2.31, resp., vs. 1.05 ± 1.10; ). SCC-Maps and EAM screening highly correlate with Ce-CMR maps in the ischemic population when compared to EAM standard (Lin’s correlation = 0.628 and 0.679, resp., vs. 0.212, ). Conclusion. The SCC-Mapping algorithm allows an operator-independent analysis of EGM signals showing better identification of the arrhythmogenic substrate characteristics when compared to standard voltage EAM., This study was supported by personal grants to A. Alcaine (Refs. BES-2011-046644 and EEBB-I-15-09466); by projects PID2019-104881RB-I00 from Ministerio de Ciencia e Innovación (Spain) and DPI2016-75458-R from Ministerio de Economía y Competitividad (Spain); and by Gobierno de Aragón (Grupo Referencia BSICoS ref.: T39_20R) cofounded by FEDER 2014–2020. This work was also supported in part by the project PI14/00759, integrated in the Plan Nacional de I+D+i and cofounded by the Instituto de Salud Carlos III (ISCIII)-Subdirección General de Evaluación and European Regional Development Fund (European Union). The computation was performed by the ICTS NANBIOSIS, more specifically by the High Performance Computing Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the University of Zaragoza. The CIBER-BBN is an initiative of Instituto de Salud Carlos III.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

T-wave morphology restitution predicts sudden cardiac death in patients with chronic heart failure

  • Ramírez, J.
  • Orini, M.
  • Mincholé, A.
  • Monasterio, V.
  • Cygankiewicz, I.
  • de Luna, A.B.
  • Martínez, J.P.
  • Pueyo, E.
  • Laguna, P.
Background Patients with chronic heart failure are at high risk of sudden cardiac death (SCD). Increased dispersion of repolarization restitution has been associated with SCD, and we hypothesize that this should be reflected in the morphology of the T‐wave and its variations with heart rate. The aim of this study is to propose an electrocardiogram (ECG)‐based index characterizing T‐wave morphology restitution (TMR), and to assess its association with SCD risk in a population of chronic heart failure patients. Methods and Results Holter ECGs from 651 ambulatory patients with chronic heart failure from the MUSIC (MUerte Súbita en Insuficiencia Cardiaca) study were available for the analysis. TMR was quantified by measuring the morphological variation of the T‐wave per RR increment using time‐warping metrics, and its predictive power was compared to that of clinical variables such as the left ventricular ejection fraction and other ECG‐derived indices, such as T‐wave alternans and heart rate variability. TMR was significantly higher in SCD victims than in the rest of patients (median 0.046 versus 0.039, P<0.001). When TMR was dichotomized at TMR=0.040, the SCD rate was significantly higher in the TMR≥0.040 group (P<0.001). Cox analysis revealed that TMR≥0.040 was strongly associated with SCD, with a hazard ratio of 3.27 (P<0.001), independently of clinical and ECG‐derived variables. No association was found between TMR and pump failure death. Conclusions This study shows that TMR is specifically associated with SCD in a population of chronic heart failure patients, and it is a better predictor than clinical and ECG‐derived variables.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Atrial fibrillation dynamics and ionic block effects in six heterogeneous human 3D virtual atria with distinct repolarization dynamics

  • Sánchez, Carlos
  • Bueno-Orovio, Alfonso
  • Pueyo, Esther
  • Rodríguez, Blanca
Atrial fibrillation (AF) usually manifests as reentrant circuits propagating through the whole atria creating chaotic activation patterns. Little is yet known about how differences in electrophysiological and ionic properties between patients modulate reentrant patterns in AF. The goal of this study is to quantify how variability in action potential duration (APD) at different stages of repolarization determines AF dynamics and their modulation by ionic block using a set of virtual whole-atria human models. Six human whole-atria models are constructed based on the same anatomical structure and fiber orientation, but with different electrophysiological phenotypes. Membrane kinetics for each whole-atria model are selected with distinct APD characteristics at 20, 50, and 90% repolarization, from an experimentally calibrated population of human atrial action potential models, including AF remodeling and acetylcholine parasympathetic effects. Our simulations show that in all whole-atria models, reentrant circuits tend to organize around the pulmonary veins and the right atrial appendage, thus leading to higher dominant frequency (DF) and more organized activation in the left atrium than in the right atrium. Differences in APD in all phases of repolarization (not only APD90) yielded quantitative differences in fibrillation patterns with long APD associated with slower and more regular dynamics. Long APD50 and APD20 were associated with increased interatrial conduction block and interatrial differences in DF and organization index, creating reentry instability and self-termination in some cases. Specific inhibitions of IK1, INaK, or INa reduce DF and organization of the arrhythmia by enlarging wave meandering, reducing the number of secondary wavelets, and promoting interatrial block in all six virtual patients, especially for the phenotypes with short APD at 20, 50, and/or 90% repolarization. This suggests that therapies aiming at prolonging the early phase of repolarization might constitute effective antiarrhythmic strategies for the pharmacological management of AF. In summary, simulations report significant differences in atrial fibrillatory dynamics resulting from differences in APD at all phases of repolarization.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Adaptive diffusion schemes for heterogeneous networks

  • Fernandez-Bes, Jesus
  • Arenas-García, Jerónimo
  • Silva, Magno T.M.
  • Azpicueta-Ruiz, Luis A.
In this paper, we deal with distributed estimation problems in diffusion networks with heterogeneous nodes, i.e., nodes that either implement different adaptive rules or differ in some other aspect such as the filter structure or length, or step size. Although such heterogeneous networks have been considered from the first works on diffusion networks, obtaining practical and robust schemes to adaptively adjust the combiners in different scenarios is still an open problem. In this paper, we study a diffusion strategy specially designed and suited to heterogeneous networks. Our approach is based on two key ingredients: 1) the adaptation and combination phases are completely decoupled, so that network nodes keep purely local estimations at all times and 2) combiners are adapted to minimize estimates of the network mean-square-error. Our scheme is compared with the standard adapt-Then-combine scheme and theoretically analyzed using energy conservation arguments. Several experiments involving networks with heterogeneous nodes show that the proposed decoupled adapt-Then-combine approach with adaptive combiners outperforms other state-of-The-Art techniques, becoming a competitive approach in these scenarios.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Pharmacological activation of TRPV4 produces immediate cell damage and induction of apoptosis in human melanoma cells and HaCaT keratinocytes

  • Olivan-Viguera, A.
  • Garcia-Otin, A.L.
  • Lozano-Gerona, J.
  • Abarca-Lachen, E.
  • Garcia-Malinis, A.J.
  • Hamilton, K.L.
  • Gilaberte, Y.
  • Pueyo, E.
  • Köhler, R.
Background TRPV4 channels are calcium-permeable cation channels that are activated by several physicochemical stimuli. Accordingly, TRPV4 channels have been implicated in the regulation of osmosensing, mechanotransduction, thermosensation, and epithelial/endothelial barrier functions. Whether TRPV4 is also mechanistically implicated in melanoma cell proliferation is not clear. Here, we hypothesized that TRPV4 is expressed in human melanoma and that pharmacological activation interferes with cell proliferation. Methodology/Principal findings TRPV4 functions were studied in melanoma cell lines (A375, SK-MEL-28, MKTBR), immortalized non-cancer keratinocytes (HaCaT), and murine 3T3 fibroblasts by patch-clamp, qRT-PCR, intracellular calcium measurements, cell proliferation, and flow cytometric assays of apoptosis and cell cycle. The selective TRPV4-activator, GSK1016790A, elicited non-selective cation currents with TRPV4-typical current-voltage-relationship in all cell lines. GSK1016790A-induced currents were blocked by the TRPV4-blocker, HC067047. TRPV4 mRNA expression was demonstrated by qRT-PCR. In A375 cells, TRPV4 activation was frequently paralleled by co-activation of calcium/calmodulin-regulated KCa3.1 channels. Light microscopy showed that TRPV4-activation produced rapid cellular disarrangement, nuclear densification, and detachment of a large fraction of all melanoma cell lines and HaCaT cells. TRPV4-activation induced apoptosis and drastically inhibited A375 and HaCaT proliferation that could be partially prevented by HC067047. Conclusions/Significance Our study showed that TRPV4 channels were functionally expressed in human melanoma cell lines and in human keratinocytes. Pharmacological TRPV4 activation in human melanoma cells and keratinocytes caused severe cellular disarrangement, necrosis and apoptosis. Pharmacological targeting of TRPV4 could be an alternative or adjuvant therapeutic strategy to treat melanoma progression and other proliferative skin disorders.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Computational techniques for ECG analysis and interpretation in light of their contribution to medical advances

  • Lyon, Aurore
  • Mincholé, Ana
  • Martínez, Juan Pablo
  • Laguna, Pablo
  • Rodríguez, Blanca
Widely developed for clinical screening, electrocardiogram (ECG) recordings capture the cardiac electrical activity from the body surface. ECG analysis can therefore be a crucial first step to help diagnose, understand and predict cardiovascular disorders responsible for 30% of deaths worldwide. Computational techniques, and more specifically machine learning techniques and computational modelling are powerful tools for classification, clustering and simulation, and they have recently been applied to address the analysis of medical data, especially ECG data. This review describes the computational methods in use for ECG analysis, with a focus on machine learning and 3D computer simulations, as well as their accuracy, clinical implications and contributions to medical advances. The first section focuses on heartbeat classification and the techniques developed to extract and classify abnormal from regular beats. The second section focuses on patient diagnosis from whole recordings, applied to different diseases. The third section presents real-time diagnosis and applications to wearable devices. The fourth section highlights the recent field of personalized ECG computer simulations and their interpretation. Finally, the discussion section outlines the challenges of ECG analysis and provides a critical assessment of the methods presented. The computational methods reported in this review are a strong asset for medical discoveries and their translation to the clinical world may lead to promising advances.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Sudden cardiac death and pump failure death prediction in chronic heart failure by combining ECG and clinical markers in an integrated risk model

  • Ramirez García, Julia
  • Orini, Michele
  • Minchole, Ana
  • Monasterio, Violeta
  • Cygankiewicz, Iwona
  • Bayes de Luna, Antonio
  • Martinez, Juan Pablo
  • Laguna, Pablo
  • Pueyo, Esther
Background: Sudden cardiac death (SCD) and pump failure death (PFD) are common endpoints in chronic heart failure (CHF) patients, but prevention strategies are different. Currently used tools to specifically predict these endpoints are limited. We developed risk models to specifically assess SCD and PFD risk in CHF by combining ECG markers and clinical variables. Methods: The relation of clinical and ECG markers with SCD and PFD risk was assessed in 597 patients enrolled in the MUSIC (MUerte Súbita en Insuficiencia Cardiaca) study. ECG indices included: turbulence slope (TS), reflecting autonomic dysfunction; T-wave alternans (TWA), reflecting ventricular repolarization instability; and T-peak-to-end restitution (¿aTpe) and T-wave morphology restitution (TMR), both reflecting changes in dispersion of repolarization due to heart rate changes. Standard clinical indices were also included. Results: The indices with the greatest SCD prognostic impact were gender, New York Heart Association (NYHA) class, left ventricular ejection fraction, TWA, ¿aTpe and TMR. For PFD, the indices were diabetes, NYHA class, ¿aTpe and TS. Using a model with only clinical variables, the hazard ratios (HRs) for SCD and PFD for patients in the high-risk group (fifth quintile of risk score) with respect to patients in the low-risk group (first and second quintiles of risk score) were both greater than 4. HRs for SCD and PFD increased to 9 and 11 when using a model including only ECG markers, and to 14 and 13, when combining clinical and ECG markers. Conclusion: The inclusion of ECG markers capturing complementary pro-arrhythmic and pump failure mechanisms into risk models based only on standard clinical variables substantially improves prediction of SCD and PFD in CHF patients.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Identification of Parameters describing Phenomenological Cardiac Action Potential Models using Sigma-Point Methods

  • Fernández-Bes
  • Jesús
  • Sampedro-Puente
  • David, Alfonso
  • Pueyo
  • Esther
Phenomenological action potential (AP) models allow reproducing characteristic features of cardiomyocytes’ electrical activity without fully describing the underlying biophysics, thus being very useful for whole-heart electrophysiological simulations. Methods to identify the parameter values of phenomenological models commonly attempt to reproduce specific AP properties rather than the whole AP waveform. In this work we propose the use of a sequential estimation approach based on sigma-point filters to adjust such parameters. The proposed methodology has been tested in estimating the parameters of the phenomenological Bueno-Cherry-Fenton model to replicate the APs generated with in silico models as well as experimentally measured APs. With the new method the whole AP waveforms can be reproduced more accurately than with previous parameter fitting methods and the AP duration restitution curves are in better agreement with available experimental data.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Comparison of ECG T-wave Duration and Morphology Restitution Markers for Sudden Cardiac Death Prediction in Chronic Heart Failure

  • Ramírez
  • Julia
  • Orini
  • Michele
  • Pueyo
  • Esther
  • Laguna
  • Pablo
An index of T-wave morphology restitution, TMR, has previously shown to be a sudden cardiac death (SCD) predictor in a population of chronic heart failure (CHF) patients. The aim of this study is to compare the predictive value of TMR, T-wave width restitution (TWR), Tpeak-to-end (Tpe) morphology restitution (TpeMR) and Tpe duration restitution (T peR) indices in the same CHF population. Holter ECG recordings from 651 CHF patients of the MUSIC study, including SCD victims and survivors, were analyzed. TMR was significantly correlated with T W R (¿=0.66), T peM R (¿=0.70) and T peR (¿=0.42). SCD victims showed significantly higher values of TMR, TWR and TpeMR than the rest of patients, with T M R being the index most strongly associated with SCD (p=0.002, p=0.006 and p=0.011, respectively). T peR values were only borderline significantly higher in SCD victims (p=0.061). Univariate Cox analysis showed that T M R was the restitution index with the strongest predictive value (hazard ratio (HR) of 1.466, p<0.001), followed by TWR (HR of 1.295, p=0.005), TpeR (HR of 1.297, p=0.004) and T peM R (HR of 1.164, p=0.020). In conclusion, considering the predictive value of the four Twave restitution indices, TMR is the preferred index for SCD risk stratification, followed by TpeMR. However, the marker TWR could also be used for SCD prediction when computational efficiency is an issue.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Quantification of t-wave morphological variability using time-warping methods

  • Ramírez, J.
  • Orini, M.
  • Pueyo, E.
  • Laguna, P.
The aim of this study is to quantify the variation of the T-wave morphology during a 24-hour electrocardiogram (ECG) recording. Two ECG-derived markers are presented to quantify T-wave morphological variability in the temporal, dw, and amplitude, da , domains. Two additional markers, dw NL and da NL , that only capture the non-linear component of dw and da are also proposed. The proposed markers are used to quantify T-wave time and amplitude variations in 500 24-hour ECG recordings from chronic heart failure patients. Additionally, two mean warped T-waves, used in the calculation of those markers, are proposed to compensate for the rate dependence of the T-wave morphology. Statistical analysis is used to evaluate the correlation between dw, dw NL , da and da NL and the maximum intra-subject RR range, ¿RR. Results show that the mean warped T-wave is able to compensate for the morphological differences due to RR dynamics. Moreover, the metrics dw and dw NL are correlated with ¿RR, but da and da NL are not. The proposed dw and dw NL quantify variations in the temporal domain of the T-wave that are correlated with the RR range and, thus, could possibly reflect the variations of dispersion of repolarization due to changes in heart rate.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

On the standardization of approximate entropy: multidimensional approximate entropy index evaluated on short-term HRV time series

  • Bolea, Juan
  • Bailón, Raquel
  • Pueyo, Esther
Background. Nonlinear heart rate variability (HRV) indices have extended the description of autonomic nervous system (ANS) regulation of the heart. One of those indices is approximate entropy, ApEn, which has become a commonly used measure of the irregularity of a time series. To calculate ApEn, a priori definition of parameters like the threshold on similarity and the embedding dimension is required, which has been shown to be critical for interpretation of the results. Thus, searching for a parameter-free ApEn-based index could be advantageous for standardizing the use and interpretation of this widely applied entropy measurement. Methods. A novel entropy index called multidimensional approximate entropy, , is proposed based on summing the contribution of maximum approximate entropies over a wide range of embedding dimensions while selecting the similarity threshold leading to maximum ApEn value in each dimension. Synthetic RR interval time series with varying levels of stochasticity, generated by both MIX(P) processes and white/pink noise, were used to validate the properties of the proposed index. Aging and congestive heart failure (CHF) were characterized from RR interval time series of available databases. Results. In synthetic time series, values were proportional to the level of randomness; i.e., increased for higher values of P in generated MIX(P) processes and was larger for white than for pink noise. This result was a consequence of all maximum approximate entropy values being increased for higher levels of randomness in all considered embedding dimensions. This is in contrast to the results obtained for approximate entropies computed with a fixed similarity threshold, which presented inconsistent results for different embedding dimensions. Evaluation of the proposed index on available databases revealed that aging was associated with a notable reduction in values. On the other hand, evaluated during the night period was considerably larger in CHF patients than in healthy subjects. Conclusion. A novel parameter-free multidimensional approximate entropy index, , is proposed and tested over synthetic data to confirm its capacity to represent a range of randomness levels in HRV time series. values are reduced in elderly patients, which may correspond to the reported loss of ANS adaptability in this population segment. Increased values measured in CHF patients versus healthy subjects during the night period point to greater irregularity of heart rate dynamics caused by the disease.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A response surface optimization approach to adjust ionic current conductances of cardiac electrophysiological models. Application to the study of potassium level changes

  • Carro, J.
  • Pueyo, E.
  • Rodriguez Matas, J.F.
Cardiac electrophysiological computational models are often developed from previously published models. The new models may incorporate additional features to adapt the model to a different species or may upgrade a specific ionic formulation based on newly available experimental data. A relevant challenge in the development of a new model is the estimation of certain ionic current conductances that cannot be reliably identified from experiments. A common strategy to estimate those conductances is by means of constrained non-linear least-squares optimization. In this work, a novel methodology is proposed for estimation of ionic current conductances of cardiac electrophysiological models by using a response surface approximation-based constrained optimization with trust region management. Polynomial response surfaces of a number of electrophysiological markers were built using statistical sampling methods. These markers included action potential duration (APD), triangulation, diastolic and systolic intracellular calcium concentration, and time constants of APD rate adaptation. The proposed methodology was applied to update the Carro et al. human ventricular action potential model after incorporation of intracellular potassium ([K+]i) dynamics. While the Carro et al. model was well suited for investigation of arrhythmogenesis, it did not allow simulation of [K+]i changes. With the methodology proposed in this study, the updated Carro et al. human ventricular model could be used to simulate [K+]i changes in response to varying extracellular potassium ([K+]o) levels. Additionally, it rendered values of evaluated electrophysiological markers within physiologically plausible ranges. The optimal values of ionic current conductances in the updated model were found in a notably shorter time than with previously proposed methodologies. As a conclusion, the response surface optimization-based approach proposed in this study allows estimating ionic current conductances of cardiac electrophysiological computational models while guaranteeing replication of key electrophysiological features and with an important reduction in computational cost with respect to previously published approaches. The updated Carro et al. model developed in this study is thus suitable for the investigation of arrhythmic risk-related conditions, including those involving large changes in potassium concentration.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Detection of ventricular premature beats based on the pressure signals of a hemodialysis machine

  • Holmer, M.
  • Martínez, J.P.
  • Gil, E.
  • Sandberg, F.
  • Olde, B.
  • Sörnmo, L.
Monitoring of ventricular premature beats (VPBs), being abundant in hemodialysis patients, can provide information on cardiovascular instability and electrolyte imbalance. In this paper, we describe a method for VPB detection which explores the signals acquired from the arterial and the venous pressure sensors, located in the extracorporeal blood circuit of a hemodialysis machine. The pressure signals are mainly composed of a pump component and a cardiac component. The cardiac component, severely overshadowed by the pump component, is estimated from the pressure signals using an earlier described iterative method. A set of simple features is extracted, and linear discriminant analysis is performed to classify beats as either normal or ventricular premature. Performance is evaluated on signals from nine hemodialysis treatments, using leave-one-out crossvalidation. The simultaneously recorded and annotated photoplethysmographic signal serves as the reference signal, with a total of 149, 686 normal beats and 3574 VPBs. The results show that VPBs can be reliably detected, quantified by a Youden''s J statistic of 0.9, for average cardiac pulse pressures exceeding 1 mmHg; for lower pressures, the J statistic drops to 0.55. It is concluded that the cardiac pressure signal is suitable for VPB detection, provided that the average cardiac pulse pressure exceeds 1 mmHg.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Otros (Other)

Editorial: Safety Pharmacology - Risk Assessment QT Interval Prolongation and Beyond

  • Grandi, E.
  • Morotti, S.
  • Pueyo, E.
  • Rodriguez, B.
The scope of safety pharmacology is to predict whether a drug is likely to cause potentially lethal adverse effects if administered to humans. While safety pharmacology has broadened its interests in recent years to the whole cardiovascular, respiratory, and central nervous systems (and is now extending to other body functions), a major focus since its inception has been assessing drug-induced prolongation in the QT interval—a surrogate biomarker for torsades de pointes (TdP) liability. Because the vast majority of drugs that can cause QT prolongation inhibit hERG channels, current regulatory guidelines concerning cardiac safety recommend that all compounds are evaluated in vitro for their hERG inhibitory potency (Redfern et al., 2003) and in vivo for their ability to cause QT/QTc interval prolongation (Food and Drug Administration, 2005) in an appropriate animal model and in humans. However, it has now become apparent that QT/QTc prolongation and hERG block are an insufficient proxy for TdP risk. While the current approach based on these markers has been successful in terms of preventing TdP risk, this regulatory paradigm might lead to withdrawal from the drug development pipeline and clinical use of potentially safe drugs. There is therefore a crucial need to develop a more accurate assessment of proarrhythmic potential of drugs...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Eigenvalue-based time delay estimation of repetitive biomedical signals

  • Laguna, P.
  • Garde, A.
  • Giraldo, B.F.
  • Meste, O.
  • Jané, R.
  • Sörnmo, L.
The time delay estimation problem associated with an ensemble of misaligned, repetitive signals is revisited. Each observed signal is assumed to be composed of an unknown, deterministic signal corrupted by Gaussian, white noise. This paper shows that maximum likelihood (ML) time delay estimation can be viewed as the maximization of an eigenvalue ratio, where the eigenvalues are obtained from the ensemble correlation matrix. A suboptimal, one-step time delay estimate is proposed for initialization of the ML estimator, based on one of the eigenvectors of the inter-signal correlation matrix. With this approach, the ML estimates can be determined without the need for an intermediate estimate of the underlying, unknown signal. Based on respiratory flow signals, simulations show that the variance of the time delay estimation error for the eigenvalue-based method is almost the same as that of the ML estimator. Initializing the maximization with the one-step estimates, rather than using the ML estimator alone, the computation time is reduced by a factor of 5M when using brute force maximization (M denoting the number of signals in the ensemble), and a factor of about 1.5 when using particle swarm maximization. It is concluded that eigenanalysis of the ensemble correlation matrix not only provides valuable insight on how signal energy, jitter, and noise influence the estimation process, but it also leads to a one-step estimator which can make the way for a substantial reduction in computation time.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automatic activation mapping and origin identification of idiopathic outflow tract ventricular arrhythmias

  • Alcaine, A.
  • Soto-Iglesias, D.
  • Acosta, J.
  • Korshunov, V.
  • Penela, D.
  • Martínez, M.
  • Linhart, M.
  • Andreu, D.
  • Fernández-Armenta, J.
  • Laguna, P.
  • Martínez, J.P.
  • Camara, O.
  • Berruezo, A.
Purpose: Activation mapping is used to guide ablation of idiopathic outflow tract ventricular arrhythmias (OTVAs). Isochronal activation maps help to predict the site of origin (SOO): left vs right outflow tract (OT). We evaluate an algorithm for automatic activation mapping based on the onset of the bipolar electrogram (EGM) signal for predicting the SOO and the effective ablation site in OTVAs. Methods: Eighteen patients undergoing ablation due to idiopathic OTVAs were studied (12 with left ventricle OT origin). Right ventricle activation maps were obtained offline with an automatic algorithm and compared with manual annotation maps obtained during the intervention. Local activation time (LAT) accuracy was assessed, as well as the performance of the 10 ms earliest activation site (EAS) isochronal area in predicting the SOO. Results: High correlation was observed between manual and automatic LATs (Spearman's: 0.86 and Lin's: 0.85, both p < 0.01). The EAS isochronal area were closely located in both map modalities (5.55 ± 3.56 mm) and at a similar distance from the effective ablation site (0.15 ± 2.08 mm difference, p = 0.859). The 10 ms isochronal area longitudinal/perpendicular diameter ratio measured from automatic maps showed slightly superior SOO identification (67% sensitivity, 100% specificity) compared with manual maps (67% sensitivity, 83% specificity). Conclusions: Automatic activation mapping based on the bipolar EGM onset allows fast, accurate and observer-independent identification of the SOO and characterization of the spreading of the activation wavefront in OTVAs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automatic diagnosis of strict left bundle branch block using a wavelet-based approach

  • Martín-Yebra, A.
  • Martínez, J.P.
Patients with left bundle branch block (LBBB) are known to have a good clinical response to cardiac resynchronization therapy. However, the high number of false positive diagnosis obtained with the conventional LBBB criteria limits the effectiveness of this therapy, which has yielded to the definition of new stricter criteria. They require prolonged QRS duration, a QS or rS pattern in the QRS complexes at leads V1 and V2 and the presence of mid-QRS notch/slurs in 2 leads within V1, V2, V5, V6, I and aVL. The aim of this work was to develop and assess a fully-automatic algorithm for strict LBBB diagnosis based on the wavelet transform. Twelve-lead, high-resolution, 10-second ECGs from 602 patients enrolled in the MADIT-CRT trial were available. Data were labelled for strict LBBB by 2 independent experts and divided into training (n = 300) and validation sets (n = 302) for assessing algorithm performance. After QRS detection, a wavelet-based delineator was used to detect individual QRS waves (Q, R, S), QRS onsets and ends, and to identify the morphological QRS pattern on each standard lead. Then, multilead QRS boundaries were defined in order to compute the global QRS duration. Finally, an automatic algorithm for notch/slur detection within the QRS complex was applied based on the same wavelet approach used for delineation. In the validation set, LBBB was diagnosed with a sensitivity and specificity of Se = 92.9% and Sp = 65.1% (Acc = 79.5%, PPV = 74% and NPV = 89.6%). The results confirmed that diagnosis of strict LBBB can be done based on a fully automatic extraction of temporal and morphological QRS features. However, it became evident that consensus in the definition of QRS duration as well as notch and slurs definitions is necessary in order to guarantee accurate and repeatable diagnosis of complete LBBB.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Baroreflex sensitivity measured by pulse photoplethysmography

  • Lázaro, Jesús
  • Gil, Eduardo
  • Orini, Michele
  • Laguna, Pablo
  • Bailón, Raquel
Novel methods for assessing baroreflex sensitivity (BRS) using only pulse photoplethysmography (PPG) signals are presented. Proposed methods were evaluated with a data set containing electrocardiogram (ECG), blood pressure (BP), and PPG signals from 17 healthy subjects during a tilt table test. The methods are based on a surrogate of a index, which is defined as the power ratio of RR interval variability (RRV) and that of systolic arterial pressure series variability (SAPV). The proposed a index surrogates use pulse-to-pulse interval series variability (PPV) as a surrogate of RRV, and different morphological features of the PPG pulse which have been hypothesized to be related to BP, as series surrogates of SAPV. A time-frequency technique was used to assess BRS, taking into account the non-stationarity of the protocol. This technique identifies two time-varying frequency bands where RRV and SAPV (or their surrogates) are expected to be coupled: the low frequency (LF, inside 0.04–0.15 Hz range), and the high frequency (HF, inside 0.15–0.4 Hz range) bands. Furthermore, time-frequency coherence is used to identify the time intervals when the RRV and SAPV (or their surrogates) are coupled. Conventional a index based on RRV and SAPV was used as Gold Standard. Spearman correlation coefficients between conventional a index and its PPG-based surrogates were computed and the paired Wilcoxon statistical test was applied in order to assess whether the indices can find significant differences (p < 0.05) between different stages of the protocol. The highest correlations with the conventional a index were obtained by the a-index-surrogate based on PPV and pulse up-slope (PUS), with 0.74 for LF band, and 0.81 for HF band. Furthermore, this index found significant differences between rest stages and tilt stage in both LF and HF bands according to the paired Wilcoxon test, as the conventional a index also did. These results suggest that BRS changes induced by the tilt test can be assessed with high correlation by only a PPG signal using PPV as RRV surrogate, and PPG morphological features as SAPV surrogates, being PUS the most convenient SAPV surrogate among the studied ones.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Quantification of Ventricular Repolarization Variation for Sudden Cardiac Death Risk Stratification in Atrial Fibrillation

  • Martín Yebra, Alba
  • Laguna, Pablo
  • Cygankiewicz, Iwona
  • Bayés-de-Luna, Antoni
  • Caiani, Enrico G.
  • Martínez, Juan Pablo
Objective: Atrial fibrillation (AF) rhythm gives rise to an irregular response in ventricular activity, preventing the use of standard ECG-derived risk markers based on ventricular repolarization heterogeneity under this particular condition. In this study we proposed new indices to quantify repolarization variations in AF patients, assessing their stratification performance in a chronic heart failure (CHF) population with AF. Methods: We developed a method based on a selective bin averaging technique. Consecutive beats preceded by a similar RR interval were selected, from which the average variation within the ST-T complex for each RR range was computed.We proposed two sets of indices: (i) the 2-beat index of ventricular repolarization variation, (I_V2), computed from pairs of stable consecutive beats; and (ii) the 3-beat indices of ventricular repolarization variation, computed in triplets of stable consecutive beats (I_V3). Results: These indices showed a significant association with sudden cardiac death (SCD) outcome in the study population. In addition, risk assessment based on the combination of the proposed indices improved stratification performance compared to their individual potential. Conclusion: Patients with enhanced ventricular repolarization variation computed in terms of the proposed indices were successfully associated to a higher SCD incidence in our study population, evidencing their prognostic value. Significance: using a simple ambulatory ECG recording, it is possible to stratify AF patients at risk of SCD, which may help cardiologists in adopting most effective therapeutic strategies, with a positive impact in both the patient and healthcare systems.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Monitoring breathing rate by fusing the physiological impact of respiration on video-photoplethysmogram with head movements

  • Iozzia, Luca
  • Lázaro, Jesús
  • Cerina, Luca
  • Silvestri, Davide
  • Mainardi, Luca
  • Laguna, Pablo
  • Gil, Eduardo
Objective: The simple observation of breathing rate (BR) remains the first and often the most sensitive marker of acute respiratory dysfunction. In fact, there are evidences that drastic changes in BR are a predictive indicator of adverse events (i.e. cardiac arrest). The aim of this study is to develop a camera-based technology that may provide near-continuously estimation of BR considering the effect of respiration on videoPPG (vPPG). &#13; Approach: The technology has been tested in two different experimental settings, including controlled BR and more challenging scenarios with spontaneous breathing pattern. Video data were processed offline to derive the vPPG signal. The method derives respiration from beat-to-beat PPG rate and morphology changes in amplitude and width driven by the physiological relationships between vPPG and respiration. Moreover, respiratory-induced head movements were used as additional source of information for the vPPG system. A combination of these methods has been exploited to estimate the respiratory rate every 10 second. &#13; Main Results: According to the results, respiratory frequencies in the central range (0.2-0.4 Hz) may be estimated using vPPG system with low relative error, eR < 2 % and interquartile range of order IQR < 5 %. However, the vPPG system showed a drop in performance at respiratory range boundaries, around 0.1 Hz and 0.5 Hz.&#13; Significance: This camera-based technology can be used as ubiquitous BR monitoring system. However, vPPG-based systems should consider the effect of the BR in the estimation, mainly in applications where respiratory rate is out of the range 0.2-0.4 Hz.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Long-term microgravity exposure increases ECG repolarization instability manifested by low-frequency oscillations of T-Wave vector

  • Palacios, Saúl
  • Caiani, Enrico G.
  • Landreani, Federica
  • Martínez, Juan Pablo
  • Pueyo, Esther
Ventricular arrhythmias and sudden cardiac death during long-term space missions are a major concern for space agencies. Long-duration spaceflight and its ground-based analog head-down bed rest (HDBR) have been reported to markedly alter autonomic and cardiac functioning, particularly affecting ventricular repolarization of the electrocardiogram (ECG). In this study, novel methods are developed, departing from previously published methodologies, to quantify the index of Periodic Repolarization Dynamics (PRD), an arrhythmic risk marker that characterizes sympathetically-mediated low-frequency oscillations in the T-wave vector. PRD is evaluated in ECGs from 42 volunteers at rest and during an orthostatic tilt table test recorded before and after 60-day –6° HDBR. Our results indicate that tilt test, on top of enhancing sympathetic regulation of heart rate, notably increases PRD, both before and after HDBR, thus supporting previous evidence on PRD being an indicator of sympathetic modulation of ventricular repolarization. Importantly, long-term microgravity exposure is shown to lead to significant increases in PRD, both when evaluated at rest and, even more notably, in response to tilt test. The extent of microgravity-induced changes in PRD has been associated with arrhythmic risk in prior studies. An exercise-based, but not a nutrition-based, countermeasure is able to partially reverse microgravity-induced effects on PRD. In conclusion, long-term exposure to microgravity conditions leads to elevated low-frequency oscillations of ventricular repolarization, which are potentiated following sympathetic stimulation and are related to increased risk for repolarization instabilities and arrhythmias. Tested countermeasures are only partially effective in counteracting microgravity effects.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A comparative study of ECG-derived respiration in ambulatory monitoring using the single-lead ECG

  • Varon, Carolina
  • Morales, John
  • Lázaro, Jesús
  • Orini, Michele
  • Deviaene, Margot
  • Kontaxis, Spyridon
  • Testelmans, Dries
  • Buyse, Bertien
  • Borzée, Pascal
  • Sörnmo, Leif
  • Laguna, Pablo
  • Gil, Eduardo
  • Bailón, Raquel
Cardiorespiratory monitoring is crucial for the diagnosis and management of multiple conditions such as stress and sleep disorders. Therefore, the development of ambulatory systems providing continuous, comfortable, and inexpensive means for monitoring represents an important research topic. Several techniques have been proposed in the literature to derive respiratory information from the ECG signal. Ten methods to compute single-lead ECG-derived respiration (EDR) were compared under multiple conditions, including different recording systems, baseline wander, normal and abnormal breathing patterns, changes in breathing rate, noise, and artifacts. Respiratory rates, wave morphology, and cardiorespiratory information were derived from the ECG and compared to those extracted from a reference respiratory signal. Three datasets were considered for analysis, involving a total 59 482 one-min, single-lead ECG segments recorded from 156 subjects. The results indicate that the methods based on QRS slopes outperform the other methods. This result is particularly interesting since simplicity is crucial for the development of ECG-based ambulatory systems.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Reperfusion Arrhythmias Increase after Superior Cervical Ganglionectomy Due to Conduction Disorders and Changes in Repolarization

  • Prado, Natalia J.
  • Muñoz, Estela M.
  • Farias Altamirano, Luz E.
  • Aguiar, Francisco
  • Ponce Zumino, Amira Z.
  • Sánchez, Francisco J.
  • Miatello, Roberto M.
  • Pueyo, Esther
  • Diez, Emiliano Raúl
Pharmacological concentrations of melatonin reduce reperfusion arrhythmias, but less is known about the antiarrhythmic protection of the physiological circadian rhythm of melatonin. Bilateral surgical removal of the superior cervical ganglia irreversibly suppresses melatonin rhythmicity. This study aimed to analyze the cardiac electrophysiological effects of the loss of melatonin circadian oscillation and the role played by myocardial melatonin membrane receptors, SERCA2A, TNFa, nitrotyrosine, TGFß, KATP channels, and connexin 43. Three weeks after bilateral removal of the superior cervical ganglia or sham surgery, the hearts were isolated and submitted to ten minutes of regional ischemia followed by ten minutes of reperfusion. Arrhythmias, mainly ventricular tachycardia, increased during reperfusion in the ganglionectomy group. These hearts also suffered an epicardial electrical activation delay that increased during ischemia, action potential alternants, triggered activity, and dispersion of action potential duration. Hearts from ganglionectomized rats showed a reduction of the cardioprotective MT2 receptors, the MT1 receptors, and SERCA2A. Markers of nitroxidative stress (nitrotyrosine), inflammation (TNFa), and fibrosis (TGFß and vimentin) did not change between groups. Connexin 43 lateralization and the pore-forming subunit (Kir6.1) of KATP channels increased in the experimental group. We conclude that the loss of the circadian rhythm of melatonin predisposes the heart to suffer cardiac arrhythmias, mainly ventricular tachycardia, due to conduction disorders and changes in repolarization.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Conditional KCa3.1-transgene induction in murine skin produces pruritic eczematous dermatitis with severe epidermal hyperplasia and hyperkeratosis

  • Lozano-Gerona, J.
  • Oliván-Viguera, A.
  • Delgado-Wicke, P.
  • Singh, V.
  • Brown, B.M.
  • Tapia-Casellas, E.
  • Pueyo, E.
  • Valero, M.S.
  • Garcia-Otín, Á.L.
  • Giraldo, P.
  • Abarca-Lachen, E.
  • Surra, J.C.
  • Osada, J.
  • Hamilton, K.L.
  • Raychaudhuri, S.P.
  • Marigil, M.
  • Juarranz, Á.
  • Wulff, H.
  • Miura, H.
  • Gilaberte, Y.
  • Köhler, R.
Ion channels have recently attracted attention as potential mediators of skin disease. Here, we explored the consequences of genetically encoded induction of the cell volume-regulating Ca2+-activated KCa3.1 channel (Kcnn4) for murine epidermal homeostasis. Doxycycline-treated mice harboring the KCa3.1+-transgene under the control of the reverse tetracycline-sensitive transactivator (rtTA) showed 800-fold channel overexpression above basal levels in the skin and solid KCa3.1-currents in keratinocytes. This overexpression resulted in epidermal spongiosis, progressive epidermal hyperplasia and hyperkeratosis, itch and ulcers. The condition was accompanied by production of the pro-proliferative and pro-inflammatory cytokines, IL-ß1 (60-fold), IL-6 (33-fold), and TNFa (26-fold) in the skin. Treatment of mice with the KCa3.1-selective blocker, Senicapoc, significantly suppressed spongiosis and hyperplasia, as well as induction of IL-ß1 (-88%) and IL-6 (-90%). In conclusion, KCa3.1-induction in the epidermis caused expression of pro-proliferative cytokines leading to spongiosis, hyperplasia and hyperkeratosis. This skin condition resembles pathological features of eczematous dermatitis and identifies KCa3.1 as a regulator of epidermal homeostasis and spongiosis, and as a potential therapeutic target.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Data-Driven Identification of Stochastic Model Parameters and State Variables: Application to the Study of Cardiac Beat-to-Beat Variability

  • Sampedro-Puente, David Adolfo
  • Fernández-Bes, Jesús
  • Virág, László
  • Varró, András
  • Pueyo, Esther
Enhanced spatiotemporal ventricular repolarization variability has been associated with ventricular arrhythmias and sudden cardiac death, but the involved mechanisms remain elusive. In this paper, a methodology for estimation of parameters and state variables of stochastic human ventricular cell models from input voltage data is proposed for investigation of repolarization variability. Methods: The proposed methodology formulates state-space representations based on developed stochastic cell models and uses the unscented Kalman filter to perform joint parameter and state estimation. Evaluation over synthetic and experimental data is presented. Results: Results on synthetically generated data show the ability of the methodology to: first, filter out measurement noise from action potential (AP) traces; second, identify model parameters and state variables from each of those individual AP traces, thus allowing robust characterization of cell-to-cell variability; and, third, replicate statistical population''s distributions of input AP-based markers, including dynamic markers quantifying beat-to-beat variability. Application onto experimental data demonstrates the ability of the methodology to match input AP traces while concomitantly inferring the characteristics of underlying stochastic cell models. Conclusion: A novel methodology is presented for estimation of parameters and hidden variables of stochastic cardiac computational models, with the advantage of providing a one-to-one match between each individual AP trace and a corresponding set of model characteristics. Significance: The proposed methodology can greatly help in the characterization of temporal (beat-to-beat) and spatial (cell-to-cell) variability in human ventricular repolarization and in ascertaining the corresponding underlying mechanisms, particularly in scenarios with limited available experimental data.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Bifurcations and Slow-Fast Analysis in a Cardiac Cell Model for Investigation of Early Afterdepolarizations

  • Barrio, R.
  • Martinez, M.A.
  • Perez, L.
  • Pueyo, E.
In this study, we teased out the dynamical mechanisms underlying the generation of arrhythmogenic early afterdepolarizations (EADs) in a three-variable model of a mammalian ventricular cell. Based on recently published studies, we consider a 1-fast, 2-slow variable decomposition of the system describing the cellular action potential. We use sweeping techniques, such as the spike-counting method, and bifurcation and continuation methods to identify parametric regions with EADs. We show the existence of isolas of periodic orbits organizing the different EAD patterns and we provide a preliminary classification of our fast-slow decomposition according to the involved dynamical phenomena. This investigation represents a basis for further studies into the organization of EAD patterns in the parameter space and the involved bifurcations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Time Course of Low-Frequency Oscillatory Behavior in Human Ventricular Repolarization Following Enhanced Sympathetic Activity and Relation to Arrhythmogenesis

  • Sampedro-Puente, David Adolfo
  • Fernandez-Bes, Jesús
  • Szentandrassy, Norbert
  • Nanasi, Péter
  • Taggart, Peter
  • Pueyo, Esther
Background and Objectives: Recent studies in humans and dogs have shown that ventricular repolarization exhibits a low-frequency (LF) oscillatory pattern following enhanced sympathetic activity, which has been related to arrhythmic risk. The appearance of LF oscillations in ventricular repolarization is, however, not immediate, but it may take up to some minutes. This study seeks to characterize the time course of the action potential (AP) duration (APD) oscillatory behavior in response to sympathetic provocations, unveil its underlying mechanisms and establish a potential link to arrhythmogenesis under disease conditions. Materials and Methods: A representative set of human ventricular computational models coupling cellular electrophysiology, calcium dynamics, β-adrenergic signaling, and mechanics was built. Sympathetic provocation was modeled via phasic changes in β-adrenergic stimulation (β-AS) and mechanical stretch at Mayer wave frequencies within the 0.03–0.15 Hz band. Results: Our results show that there are large inter-individual differences in the time lapse for the development of LF oscillations in APD following sympathetic provocation, with some cells requiring just a few seconds and other cells needing more than 3 min. Whereas, the oscillatory response to phasic mechanical stretch is almost immediate, the response to β-AS is much more prolonged, in line with experimentally reported evidences, thus being this component the one driving the slow development of APD oscillations following enhanced sympathetic activity. If β-adrenoceptors are priorly stimulated, the time for APD oscillations to become apparent is remarkably reduced, with the oscillation time lapse being an exponential function of the pre-stimulation level. The major mechanism underlying the delay in APD oscillations appearance is related to the slow IKs phosphorylation kinetics, with its relevance being modulated by the IKs conductance of each individual cell. Cells presenting short oscillation time lapses are commonly associated with large APD oscillation magnitudes, which facilitate the occurrence of pro-arrhythmic events under disease conditions involving calcium overload and reduced repolarization reserve. Conclusions: The time course of LF oscillatory behavior of APD in response to increased sympathetic activity presents high inter-individual variability, which is associated with different expression and PKA phosphorylation kinetics of the IKs current. Short time lapses in the development of APD oscillations are associated with large oscillatory magnitudes and pro-arrhythmic risk under disease conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Mechanisms Underlying Interactions Between Low-Frequency Oscillations and Beat-to-Beat Variability of Celullar Ventricular Repolarization in Response to Sympathetic Stimulation: Implications for Arrhythmogenesis

  • Sampedro-Puente, David Adolfo
  • Fernandez-Bes, Jesús
  • Porter, Bradley
  • Duijvenboden, Stef an van
  • Taggart, Peter
  • Pueyo, Esther
Background and Objectives: Enhanced beat-to-beat variability of ventricular repolarization (BVR) has been linked to arrhythmias and sudden cardiac death. Recent experimental studies on human left ventricular epicardial electrograms have shown that BVR closely interacts with low-frequency (LF) oscillations of activation recovery interval during sympathetic provocation. In this work human ventricular computational cell models are developed to reproduce the experimentally observed interactions between BVR and its LF oscillations, to assess underlying mechanisms and to establish a relationship with arrhythmic risk. Materials and Methods: A set of human ventricular action potential (AP) models covering a range of experimental electrophysiological characteristics was constructed. These models incorporated stochasticity in major ionic currents as well as descriptions of ß-adrenergic stimulation and mechanical effects to investigate the AP response to enhanced sympathetic activity. Statistical methods based on Automatic Relevance Determination and Canonical Correlation Analysis were developed to unravel individual and common factors contributing to BVR and LF patterning of APD in response to sympathetic provocation. Results: Simulated results reproduced experimental evidences on the interactions between BVR and LF oscillations of AP duration (APD), with replication of the high inter-individual variability observed in both phenomena. ICaL, IKr and IK1 currents were identified as common ionic modulators of the inter-individual differences in BVR and LF oscillatory behavior and were shown to be crucial in determining susceptibility to arrhythmogenic events. Conclusions: The calibrated family of human ventricular cell models proposed in this study allows reproducing experimentally reported interactions between BVR and LF oscillations of APD. Ionic factors involving ICaL, IKr and IK1 currents are found to underlie correlated increments in both phenomena in response to sympathetic provocation. A link to arrhythmogenesis is established for concomitantly elevated levels of BVR and its LF oscillations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A Novel Paradigm for in Silico Simulation of Cardiac Electrophysiology Through the Mixed Collocation Meshless Petrov-Galerkin Method

  • Mountris, K.A.
  • Sanchez, C.
  • Pueyo, E.
Multi-scale cardiac electrophysiological modeling involves high computational load due to the inherent complexity as well as to limitations of the employed numerical methods (e.g., Finite Element Method - FEM). This study investigates the use of the Meshless Local Petrov-Galerkin Mixed Collocation (MLPG-MC) method to simulate cardiac electrophysiology. MLPG-MC is a truly meshless method where both the unknown function and its gradient are interpolated using nodal collocation. A 3 cm × 3 cm human ventricular tissue was simulated based on the monodomain reaction-diffusion model using the operator splitting technique. MLPG-MC or FEM were used to solve the diffusion term and the O''Hara-Virág-Varró-Rudy AP model to represent cellular electrophysiology at baseline and under 30% IKr inhibition (IKr30). Mean differences between MLPG-MC and FEM in AP duration at 90% (APD90), 50% (APD50) and 20% (APD20) repolarization levels were 4.47%, 4.16% and 3.29% for baseline conditions and 3.66%, 2.10% and 1.62% for IKr30 conditions. The computational time associated with each of the two methods was comparable. In conclusion, considering that MLPG-MC does not involve any mesh requirements and is well suited for massive parallelization, this study shows that it represents a promising alternative to FEM for cardiac electrophysiology simulations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Response of Ventricular Repolarization to Simulated Microgravity Measured by Periodic Repolarization Dynamics Using Phase-Rectified Signal Averaging

  • Palacios, S.
  • Caiani, E.G.
  • Pueyo, E.
  • Martínez, J.P.
Head-Down Bed Rest (HDBR) microgravity simulation induces cardiovascular deconditioning, including effects on ventricular repolarization. The index of Periodic Repolarization Dynamics (PRD) was developed to quantify low-frequency oscillations of cardiac repolarization. In this study, PRD was quantified by Phase Rectified Signal Averaging (PRDPRSA) and Continuous Wavelet Transform (PRDCWT) methods. PRD was analyzed in ECGs from 22 volunteers at rest and during orthostatic Tilt-Table Test (TTT) performed before and after -6° 60-days HDBR. Significant correlation was found between PRD measured by PRSA and CWT (Pearson''s ¿ = 0.93, p < 10-54 and Kendall''s t = 0.79 p < 10-38). A highly significant increase was found when PRDPRSA values were measured at POST-HDBR with respect to PRE-HDBR in the tilt phase: 1.40 [1.10] deg and 0.97 [0.90] deg (median [IQR]), p = 0.008, respectively. PRDPRSA also increased significantly in the tilt phase with respect to baseline, both at POST-HDBR (0.90 [0.57] deg, p = 0.003) and at PRE-HDBR (0.75 [0.45] deg, p = 0.011). PRD, either measured with PRSA or with CWT, is able to measure changes in ventricular repolarization induced by microgravity simulation as well as following sympathetic provocation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Influence of the Stimulation Current on the Differences between Cell and Tissue Electrophysiological Simulations

  • Monasterio, V.
  • Pueyo, E.
  • Rodríguez-Matas, J.F.
  • Carro, J.
This study compares stimulation waveforms for single-cell simulations. The alternatives include monophasic and biphasic current pulses, and a new waveform that resembles the transmembrane current responsible for conduction in tissue. Results indicate that the new stimulation produces the lowest mismatch between action potential markers simulated in cell and in tissue. In comparison with the monophasic stimulation, the new stimulation reduced cell-fiber differences by 99% for triangulation, by 95% for maximum transmembrane voltage, and by 76% for the maximum voltage slope. In conclusion, the new stimulation waveform could help to improve the trustworthiness of single-cell simulations in studies involving tissue-derived markers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

T-Wave Morphology Changes as Surrogate for Blood Potassium Concentration in Hemodialysis Patients

  • Palmieri, F.
  • Ramírez, J.
  • Laguna, P.
  • Gomis, P.
  • Ferreira, D.
  • Ruiz, J.E.
  • Bergasa, B.
  • Martín-Yebra, A.
  • Bukhari, H.A.
  • Pueyo, E.
  • Martínez, J.P.
End-stage renal disease (ESRD) patients undergoing hemodialysis (HD) are at high risk of arrhythmias and sudden cardiac death as a result of blood potassium concentration ([K+ ]) changes. The aim of this study is to investigate if dw, a time-warping-based electrocardiogram (ECG) biomarker of T-wave morphology changes, reflects [K+] evolution in HD patients, facilitating noninvasive [K+] monitoring and avoiding in-hospital blood tests analysis. 48-hour ECGs and a set of hourly-collected blood samples from 12 ESRD patients were acquired and analyzed. dw was calculated between a reference T-wave, measured at the end of the HD session, and the T-waves corresponding to each hour along the whole HD session, when [K+] was measured from blood samples. The values of dw correlated with the relative variations in [K+] with respect to the reference value (end of HD, ¿[K+ ]), with a median (interquartile) correlation coefficient of 0.90 (0.30), evidencing a strong relation between them. Our findings support the use of dw as a surrogate of ¿[K+], suggesting a potential use of dw for non-invasive hyperkalemia monitoring both in hospital and ambulatory settings.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Transmural Ventricular Heterogeneities Play a Major Role in Determining T-Wave Morphology at Different Extracellular Potassium Levels

  • Bukhari, H.A.
  • Palmieri, F.
  • Ferreira, D.
  • Potse, M.
  • Ramírez, J.
  • Laguna, P.
  • Sánchez, C.
  • Pueyo, E.
End-stage renal disease (ESRD) affects more than 10% of the world population. ESRD patients present impaired potassium homeostasis, which increases the risk for ventricular arrhythmias and sudden cardiac death. Noninvasive estimation of serum potassium, [K+], before the patient experiences serious consequences is of major importance. In this study, we investigated the relationship of [K+] with three T-wave morphological descriptors: the T-wave width (Tw), slope-to-amplitude ratio (TSA) and temporal morphological variability (dw) from ECGs of 12 ESRD patients undergoing hemodialysis and from simulated ECGs. Spearman''s correlation coefficients between the descriptors Tw, TSA and dw and [K+] were -0.5, 0. 8 and 0.65, respectively. These associations were, however, highly patient-dependent. The high inter-individual variability in T-wave morphology, particularly observed at high [K+], was reproduced in the simulations and could be explained by differences in transmural heterogeneities, with 10% variations in the proportion of midmyocardial cells leading to changes larger than 15% in T-wave morphology. In conclusion, T-wave morphological descriptors have the potential to be used as predictors of [K+] in ESRD patients, but their associated inter-individual variability should be taken into account, especially under hyperkalemic conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Otros (Other)

Excitable dynamics in neural and cardiac systems

  • Barrio, R.
  • Coombes, S.
  • Desroches, M.
  • Fenton, F.
  • Luther, S.
  • Pueyo, E.
The application of mathematics, physics and engineering to medical research is continuously growing; interactions among these disciplines have become increasingly important and have contributed to an improved understanding of clinical and biological phenomena, with implications for disease prevention, diagnosis and treatment. This special issue presents examples of this synergy, with a particular focus on the investigation of cardiac and neural excitability. This issue includes 24 original research papers and covers a broad range of topics related to the physiological and pathophysiological function of the brain and the heart. Studies span scales from isolated neurons and small networks of neurons to whole-organ dynamics for the brain and from cardiac subcellular domains and cardiomyocytes to one-dimensional tissues for the heart. This preface is part of the Special Issue on “Excitable Dynamics in Neural and Cardiac Systems”.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Effect of yoga on pulse rate variability measured from a venous pressure waveform

  • Hernando, D.
  • Nardelli, M.
  • Hocking, K.
  • Lazaro, J.
  • Alvis, B.
  • Gil, E.
  • Scilingo, E.P.
  • Brophy, D.R.
  • Valenza, G.
  • Laguna, P.
  • Brophy, C.
  • Bailon, R.
The benefits of yoga have been studied in different fields, from chronic health conditions to mental disorders, showing that it can help to improve the overall health. In particular, it has been proven that yoga also improves the autonomic function. Heart rate variability (HRV) at rest is commonly used as a non-invasive measure of autonomic regulation of heart rate. Alternatively, pulse rate variability (PRV) has been proposed as a surrogate of HRV. VoluMetrix has developed a novel technology that captures venous waveforms via sensors on the volar aspect of the wrist, called NIVAband. This study aims to assess the effect of yoga in the autonomic nervous system by analyzing the PRV obtained from the NIVA signal. Temporal (statistics of the normal-to-normal intervals), spectral (power in low and high frequency bands) and nonlinear (lagged Poincaré Plot analysis) parameters are analyzed before and after a yoga session in 20 healthy volunteers. The PRV analysis shows an increase in parameters related to parasympathetic activity and overall variability, and a decrease in parameters related to sympathetic activity and mean heart rate. These results support the beneficial effect of yoga in autonomic nervous system, increasing the parasympathetic activity.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Characterization of Spatiooral Cardiac Action Potential Variability at Baseline and under ß-Adrenergic Stimulation by Combined Unscented Kalman Filter and Double Greedy Dimension Reduction

  • Sampedro-Puente, D.A.
  • Raphel, F.
  • Fernandez-Bes, J.
  • Laguna, P.
  • Lombardi, D.
  • Pueyo, E.
Objective: Elevated spatiooral variability of human ventricular repolarization has been related to increased risk for ventricular arrhythmias and sudden cardiac death, particularly under ß-adrenergic stimulation (ß-AS). This work presents a methodology for theoretical characterization of temporal and spatial repolarization variability at baseline conditions and in response to ß-AS. For any measured voltage trace, the proposed methodology estimates the parameters and state variables of an underlying human ventricular action potential (AP) model by combining Double Greedy Dimension Reduction (DGDR) with automatic selection of biomarkers and the Unscented Kalman Filter (UKF). Such theoretical characterization can facilitate subsequent characterization of underlying variability mechanisms. Material and Methods: Given an AP trace, initial estimates for the ionic conductances in a stochastic version of the baseline human ventricular O'Hara et al. model were obtained by DGDR. Those estimates served to initialize and update model parameter estimates by the UKF method based on formulation of an associated nonlinear state-space representation and joint estimation of model parameters and state variables. Similarly, ß-AS-induced phosphorylation levels of cellular substrates were estimated by the DGDR-UKF methodology. Performance was tested by building an experimentally-calibrated population of virtual cells, from which synthetic AP traces were generated for baseline and ß-AS conditions. Results: The combined DGDR-UKF methodology led to 25% reduction in the error associated with estimation of ionic current conductances at baseline conditions and phosphorylation levels under ß-AS with respect to individual DGDR and UKF methods. This improvement was not at the expense of higher computational load, which was diminished by 90% with respect to the individual UKF method. Both temporal and spatial AP variability of repolarization were accurately characterized by the DGDR-UKF methodology. Conclusions: A combined DGDR-UKF methodology is proposed for parameter and state variable estimation of human ventricular cell models from available AP traces at baseline and under ß-AS. This methodology improves the estimation performance and reduces the convergence time with respect to individual DGDR and UKF methods and renders a suitable approach for computational characterization of spatiooral repolarization variability to be used for ascertainment of variability mechanisms and its relation to arrhythmogenesis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

SK Channel Block and Adrenergic Stimulation Counteract Acetylcholine-Induced Arrhythmogenic Effects in Human Atria

  • Celotto, Chiara
  • Sánchez, Carlos
  • Mountris, Konstantinos A.
  • Laguna, Pablo
  • Pueyo, Esther
There is increasing evidence on the role of the autonomic nervous system in the pathogenesis of atrial fibrillation. Interventions targeting autonomic modulation of atrial electrical activity have been shown to reduce the incidence of atrial arrhythmias. Additionally, recent investigations have proved that pharmacological therapies inhibiting small-conductance calcium-activated potassium (SK) channels are able to lessen cholinergic effects in the atria.In this study we use computational modeling and simulation to test individual and combined effects of SK channel block and adrenergic stimulation in counteracting detrimental effects induced by the parasympathetic neurotransmitter acetylcholine (ACh) on human atrial electrophysiology. Cell and tissue models are built that incorporate descriptions of SK channels as well as of isoproterenol (Iso)- and ACh-mediated regulation of the atrial action potential (AP). Three different cellular AP models, representing a range of physiological AP shapes, are considered and both homogeneous and heterogeneous ACh distributions in atrial tissue are simulated.At the cellular level, SK channel block is demonstrated to partially revert shortening of AP duration (APD) mediated by ACh at various doses, whereas 1 µM Iso has a variable response depending on the AP shape. The combination of SK block and Iso is in all cases able to take APD back to baseline levels, recovering between 82% and 120% of the APD shortening induced by 0.1 µM ACh. At the tissue level, SK block and Iso alone or in combination do not exert remarkable effects on conduction velocity, but the combination of the two is able to notably prolong the ACh-mediated APD shortening, thus increasing the wavelength for reentry.In conclusion, the results from this study support the combination of SK channel block and adrenergic stimulation as a potential option to counteract parasympathetically-mediated proarrhythmic effects in the human atria.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Routes to tripod gait movement in hexapods

  • Barrio, R.
  • Lozano, A.
  • Martínez, M.A.
  • Rodríguez, M.
  • Serrano. S.
The use of hierarchical networks in motor pattern generation in hexapod robots and in insect movement provides ways to understand and control both systems. In this paper we consider the Central Pattern Generator (CPG) of insect movement consisting of six coupled neurons developed by Ghigliazza and Holmes (2004) that produces the global leg coordination pattern. We provide a detailed study of the possible gaits generated by the CPG through different numerical techniques recently developed for the study of small networks, which allow us to consider the complete model without any simplification. We combine the analysis of isolated neurons (using several three dimensional parameter spaces) to give a roadmap of the dynamics of the neurons involved, lateral phase lag plots to show the convergence and transitions towards particular patterns and a quasi-Monte Carlo sweeping method to describe different pattern routes in the parametric phase space. In all of our studies we have found the same final result: most of the observed patterns follow routes that lead to the stable tripod gait. We obtain several routes made of symmetrical patterns, but despite considering mainly a symmetric leg CPG we detect non-symmetrical patterns that provide (minor) routes present in the model. The bifurcations of the main pattern routes detected in the parameter space are studied in detail using continuation techniques. This study reveals the bifurcations that create and destroy the different routes and how for large values of some parameters only the tripod gait is present. Based on the symmetric case, a preliminary study of asymmetric configurations is done revealing the robustness of the already located patterns and routes. Due to the relevance of the tripod gait, and since more parameters are included in this study, we introduce an algorithm to locate the limit of the tripod gait in the parameter space, which shows that there is a large three parametric region where the tripod pattern is ubiquitous and highly dominant in rapidly moving insect regimes.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Automatic activation mapping and origin identification of idiopathic outflow tract ventricular arrhythmias

  • Alcaine, Alejandro
  • Soto-Iglesias, David
  • Acosta, Juan Carlos
  • Korshunov, Viatcheslav
  • Penela, Diego
  • Martínez, Mikel
  • Linhart, Markus
  • Andreu Martínez, David
  • Fernández-Armenta, Juan
  • Laguna, Pablo
  • Martínez, Juan Pablo
  • Camara, Oscar
  • Berruezo Sánchez, Antonio
Purpose: Activation mapping is used to guide ablation of idiopathic outflow tract ventricular arrhythmias (OTVAs). Isochronal activation maps help to predict the site of origin (SOO): left vs right outflow tract (OT). We evaluate an algorithm for automatic activation mapping based on the onset of the bipolar electrogram (EGM) signal for predicting the SOO and the effective ablation site in OTVAs. Methods: Eighteen patients undergoing ablation due to idiopathic OTVAs were studied (12 with left ventricle OT origin). Right ventricle activation maps were obtained offline with an automatic algorithm and compared with manual annotation maps obtained during the intervention. Local activation time (LAT) accuracy was assessed, as well as the performance of the 10 ms earliest activation site (EAS) isochronal area in predicting the SOO. Results: High correlation was observed between manual and automatic LATs (Spearman's: 0.86 and Lin's: 0.85, both p < 0.01). The EAS isochronal area were closely located in both map modalities (5.55 ± 3.56 mm) and at a similar distance from the effective ablation site (0.15 ± 2.08 mm difference, p = 0.859). The 10 ms isochronal area longitudinal/perpendicular diameter ratio measured from automatic maps showed slightly superior SOO identification (67% sensitivity, 100% specificity) compared with manual maps (67% sensitivity, 83% specificity). Conclusions: Automatic activation mapping based on the bipolar EGM onset allows fast, accurate and observer-independent identification of the SOO and characterization of the spreading of the activation wavefront in OTVAs., This study was supported by personal grants to A.A. refs.: BES-2011-046644 and EEBB-I-15-09466, by projects TEC2013-42140-R, DPI2016-75458-R and TIN2011-28067 from Ministerio de Economía y Competitividad. Also by Gobierno de Aragón (Spain) and European Social Fund (EU) through Grupo Consolidado BSICoS ref.: T 96. The CIBER-BBN is an initiative of Instituto de Salud Carlos III. This work was also supported in part by the project PI14/00759, integrated in the Plan Nacional de I + D + i and co-funded by the ISCIII-Subdirección General de Evaluación and the Fondo Europeo de Desarrollo Regional (FEDER).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Automatic detection of slow conducting channels during substrate ablation of scar-related ventricular arrhythmias

  • Alcaine, Alejandro
  • Jáuregui, Beatriz
  • Soto-Iglesias, David
  • Acosta, Juan Carlos
  • Penela, Diego
  • Fernández-Armenta, Juan
  • Linhart, Markus
  • Andreu Martínez, David
  • Mont, Lluís
  • Laguna, Pablo
  • Camara, Oscar
  • Martínez, Juan Pablo
  • Berruezo Sánchez, Antonio
Background. Voltage mapping allows identifying the arrhythmogenic substrate during scar-related ventricular arrhythmia (VA) ablation procedures. Slow conducting channels (SCCs), defined by the presence of electrogram (EGM) signals with delayed components (EGM-DC), are responsible for sustaining VAs and constitute potential ablation targets. However, voltage mapping, as it is currently performed, is time-consuming, requiring a manual analysis of all EGMs to detect SCCs, and its accuracy is limited by electric far-field. We sought to evaluate an algorithm that automatically identifies EGM-DC, classifies mapping points, and creates new voltage maps, named “Slow Conducting Channel Maps” (SCC-Maps). Methods. Retrospective analysis of electroanatomic maps (EAM) from 20 patients (10 ischemic, 10 with arrhythmogenic right ventricular dysplasia/cardiomyopathy) was performed. EAM voltage maps were acquired during sinus rhythm and used for ablation. Preprocedural contrast-enhanced cardiac magnetic resonance (Ce-CMR) imaging was available for the ischemic population. Three mapping modalities were analysed: (i) EAM voltage maps using standard (EAM standard) or manual (EAM screening) thresholds for defining core and border zones; (ii) SCC-Maps derived from the use of the novel SCC-Mapping algorithm that automatically identify EGM-DCs measuring the voltage of the local component; and (iii) Ce-CMR maps (when available). The ability of each mapping modality in identifying SCCs and their agreement was evaluated. Results. SCC-Maps and EAM screening identified a greater number of SCC entrances than EAM standard (3.45 ± 1.61 and 2.95 ± 2.31, resp., vs. 1.05 ± 1.10; ). SCC-Maps and EAM screening highly correlate with Ce-CMR maps in the ischemic population when compared to EAM standard (Lin’s correlation = 0.628 and 0.679, resp., vs. 0.212, ). Conclusion. The SCC-Mapping algorithm allows an operator-independent analysis of EGM signals showing better identification of the arrhythmogenic substrate characteristics when compared to standard voltage EAM., This study was supported by personal grants to A. Alcaine (Refs. BES-2011-046644 and EEBB-I-15-09466); by projects PID2019-104881RB-I00 from Ministerio de Ciencia e Innovación (Spain) and DPI2016-75458-R from Ministerio de Economía y Competitividad (Spain); and by Gobierno de Aragón (Grupo Referencia BSICoS ref.: T39_20R) cofounded by FEDER 2014–2020. This work was also supported in part by the project PI14/00759, integrated in the Plan Nacional de I+D+i and cofounded by the Instituto de Salud Carlos III (ISCIII)-Subdirección General de Evaluación and European Regional Development Fund (European Union). The computation was performed by the ICTS NANBIOSIS, more specifically by the High Performance Computing Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the University of Zaragoza. The CIBER-BBN is an initiative of Instituto de Salud Carlos III.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Sudden cardiac death and pump failure death prediction in chronic heart failure by combining ECG and clinical markers in an integrated risk model

  • Ramírez, Julia|||0000-0003-4130-5866
  • Orini, Michele
  • Mincholé, Ana
  • Monasterio, Violeta
  • Cygankiewicz, Iwona
  • Bayés de Luna, Antonio|||0000-0003-1676-207X
  • Martínez, Juan Pablo
  • Laguna, Pablo|||0000-0003-3434-9254
  • Pueyo, Esther
Sudden cardiac death (SCD) and pump failure death (PFD) are common endpoints in chronic heart failure (CHF) patients, but prevention strategies are different. Currently used tools to specifically predict these endpoints are limited. We developed risk models to specifically assess SCD and PFD risk in CHF by combining ECG markers and clinical variables. The relation of clinical and ECG markers with SCD and PFD risk was assessed in 597 patients enrolled in the MUSIC (MUerte Súbita en Insuficiencia Cardiaca) study. ECG indices included: turbulence slope (TS), reflecting autonomic dysfunction; T-wave alternans (TWA), reflecting ventricular repolarization instability; and T-peak-to-end restitution (Δ α Tpe ) and T-wave morphology restitution (TMR), both reflecting changes in dispersion of repolarization due to heart rate changes. Standard clinical indices were also included. The indices with the greatest SCD prognostic impact were gender, New York Heart Association (NYHA) class, left ventricular ejection fraction, TWA, Δ α Tpe and TMR. For PFD, the indices were diabetes, NYHA class, Δ α Tpe and TS. Using a model with only clinical variables, the hazard ratios (HRs) for SCD and PFD for patients in the high-risk group (fifth quintile of risk score) with respect to patients in the low-risk group (first and second quintiles of risk score) were both greater than 4. HRs for SCD and PFD increased to 9 and 11 when using a model including only ECG markers, and to 14 and 13, when combining clinical and ECG markers. The inclusion of ECG markers capturing complementary pro-arrhythmic and pump failure mechanisms into risk models based only on standard clinical variables substantially improves prediction of SCD and PFD in CHF patients.