Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automatic activation mapping and origin identification of idiopathic outflow tract ventricular arrhythmias

  • Alcaine, A.
  • Soto-Iglesias, D.
  • Acosta, J.
  • Korshunov, V.
  • Penela, D.
  • Martínez, M.
  • Linhart, M.
  • Andreu, D.
  • Fernández-Armenta, J.
  • Laguna, P.
  • Martínez, J.P.
  • Camara, O.
  • Berruezo, A.
Purpose: Activation mapping is used to guide ablation of idiopathic outflow tract ventricular arrhythmias (OTVAs). Isochronal activation maps help to predict the site of origin (SOO): left vs right outflow tract (OT). We evaluate an algorithm for automatic activation mapping based on the onset of the bipolar electrogram (EGM) signal for predicting the SOO and the effective ablation site in OTVAs. Methods: Eighteen patients undergoing ablation due to idiopathic OTVAs were studied (12 with left ventricle OT origin). Right ventricle activation maps were obtained offline with an automatic algorithm and compared with manual annotation maps obtained during the intervention. Local activation time (LAT) accuracy was assessed, as well as the performance of the 10 ms earliest activation site (EAS) isochronal area in predicting the SOO. Results: High correlation was observed between manual and automatic LATs (Spearman's: 0.86 and Lin's: 0.85, both p < 0.01). The EAS isochronal area were closely located in both map modalities (5.55 ± 3.56 mm) and at a similar distance from the effective ablation site (0.15 ± 2.08 mm difference, p = 0.859). The 10 ms isochronal area longitudinal/perpendicular diameter ratio measured from automatic maps showed slightly superior SOO identification (67% sensitivity, 100% specificity) compared with manual maps (67% sensitivity, 83% specificity). Conclusions: Automatic activation mapping based on the bipolar EGM onset allows fast, accurate and observer-independent identification of the SOO and characterization of the spreading of the activation wavefront in OTVAs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automatic detection of slow conducting channels during substrate ablation of scar-related ventricular arrhythmias

  • Alcaine, Alejandro
  • Jáuregui, Beatriz
  • Soto-Iglesias, David
  • Acosta, Juan
  • Penela, Diego
  • Fernández-Armenta, Juan
  • Linhart, Markus
  • Andreu, David
  • Mont, Lluis
  • Laguna, Pablo
  • Cámara, Óscar
  • Martínez, Juan Pablo
  • Berruezo, Antonio
Background. Voltage mapping allows identifying the arrhythmogenic substrate during scar-related ventricular arrhythmia (VA) ablation procedures. Slow conducting channels (SCCs), defined by the presence of electrogram (EGM) signals with delayed components (EGM-DC), are responsible for sustaining VAs and constitute potential ablation targets. However, voltage mapping, as it is currently performed, is time-consuming, requiring a manual analysis of all EGMs to detect SCCs, and its accuracy is limited by electric far-field. We sought to evaluate an algorithm that automatically identifies EGM-DC, classifies mapping points, and creates new voltage maps, named "Slow Conducting Channel Maps" (SCC-Maps). Methods. Retrospective analysis of electroanatomic maps (EAM) from 20 patients (10 ischemic, 10 with arrhythmogenic right ventricular dysplasia/cardiomyopathy) was performed. EAM voltage maps were acquired during sinus rhythm and used for ablation. Preprocedural contrast-enhanced cardiac magnetic resonance (Ce-CMR) imaging was available for the ischemic population. Three mapping modalities were analysed: (i) EAM voltage maps using standard (EAM standard) or manual (EAM screening) thresholds for defining core and border zones; (ii) SCC-Maps derived from the use of the novel SCC-Mapping algorithm that automatically identify EGM-DCs measuring the voltage of the local component; and (iii) Ce-CMR maps (when available). The ability of each mapping modality in identifying SCCs and their agreement was evaluated. Results. SCC-Maps and EAM screening identified a greater number of SCC entrances than EAM standard (3.45 ± 1.61 and 2.95 ± 2.31, resp., vs. 1.05 ± 1.10; p<0.01). SCC-Maps and EAM screening highly correlate with Ce-CMR maps in the ischemic population when compared to EAM standard (Lin''s correlation = 0.628 and 0.679, resp., vs. 0.212, p<0.01). Conclusion. The SCC-Mapping algorithm allows an operator-independent analysis of EGM signals showing better identification of the arrhythmogenic substrate characteristics when compared to standard voltage EAM.