PROCESADO MULTIMODAL DE SEÑALES BIOMEDICAS PARA EL ANALISIS Y LA CARACTERIZACION FISIOLOGICA DE AFECCIONES CARDIOVASCULARES, RESPIRATORIAS Y AUTONOMICAS.

BES-2011-046644

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Formación de Recursos Humanos de Investigación
Subprogram subprograma de Formación de Personal Investigador (FPI)
Call Contratos Predoctorales
Call year 2011
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Formación e Incorporación de Investigadores
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Estimation of high-density activation maps during atrial fibrillation

  • Alcaine, A.
  • De Groot, N.M.S.
  • Laguna, P.
  • Martínez, J.P.
  • Houben, R.P.M.
The study of activation maps using multi-electrode arrays (MEA) can help to understand atrial fibrillation (AF) mechanisms. Activation mapping based on recorded unipolar electrograms (u-EGM) rely on the local activation time (LAT) detector, which has a limited robustness, accuracy, and generally requires manual post-edition. In general, LAT detection ignores spatiotemporal information about activation and conduction conveyed by the relation between signals of the MEA sensor. This work proposes an approach to construct activation maps by simultaneous analysis of u-EGMs from small clusters of MEA electrodes. The algorithm iteratively fits an activation pattern model to the acquired data. Accuracy was evaluated by comparing with audited maps created by expert electrophysiologists from a patient undergoing open-chest surgery during AF. The estimation error was -0.29 ± 6.01 ms (236 maps, 28369 LATs) with high correlation (¿ = 0.93). Therefore, activation maps can be decomposed into local activation patterns derived from fitting an activation model, resulting in smooth and comprehensive high-density activation maps.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Spatiotemporal Model-Based Estimation of High-Density Atrial Fibrillation Activation Map

  • Alcaine, Alejandro
  • de Groot, N.M.
  • Laguna, Pablo
  • Martínez, J.P.
  • Houben, R.P.
Examination of activation maps using multi-electrode array (MEA) sensors can help to understand the mechanisms underlying atrial fibrillation (AF). Classically, creation of activation maps starts with detection of local activation times (LAT) based on recorded unipolar electrograms. LAT detection has a limited robustness and accuracy, and generally requires manual edition. In general, LAT detection ignores spatiotemporal information of activation embedded in the relation between electrode signals on the MEA mapping sensor. In this work, a unified approach to construct activation maps by simultaneous analysis of activation patterns from overlapping clusters of MEA electrodes is proposed. An activation model fits on the measured data by iterative optimization of the model parameters based on a cost function. The accuracy of the estimated activation maps was evaluated by comparison with audited maps created by expertelectrophysiologists during sinus rhythm (SR) and AF. During SR recordings, 25 activation maps (3100 LATs) were automatically determined resulting in an average LAT estimation error of -0.66 ±2.00msand a correlation of ¿s=0.98compared to the expert reference. During AF recordings (235 maps, 28226 LATs), the estimation error was -0.83 ±6.02mswith only a slightly lower correlation (¿s=0.93). In conclusion, complex spatial activation patterns can be decomposed into local activation patterns derived from fitting an activation model, allowing the creation of smooth and comprehensive high-density activation maps.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A multi-variate predictability framework to assess invasive cardiac activity and interactions during atrial fibrillation

  • Alcaine, Alejandro
  • Masè, Michela
  • Cristoforetti, Alessandro
  • Ravelli, Flavia
  • Nollo, Giandomenico
  • Laguna, Pablo
  • Martinez, Juan Pablo
  • Faes, Luca
Objective: This study introduces a predictability framework based on the concept of Granger causality (GC), in order to analyze the activity and interactions between different intracardiac sites during atrial fibrillation (AF). Methods: GC-based interactions were studied using a three-electrode analysis scheme with multi-variate autoregressive models of the involved preprocessed intracardiac signals. The method was evaluated in different scenarios covering simulations of complex atrial activity as well as endocardial signals acquired from patients. Results: The results illustrate the ability of the method to determine atrial rhythm complexity and to track and map propagation during AF. Conclusion: The proposed framework provides information on the underlying activation and regularity, does not require activation detection or postprocessing algorithms and is applicable for the analysis of any multielectrode catheter. Significance: The proposed framework can potentially help to guide catheter ablation interventions of AF.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automatic activation mapping and origin identification of idiopathic outflow tract ventricular arrhythmias

  • Alcaine, A.
  • Soto-Iglesias, D.
  • Acosta, J.
  • Korshunov, V.
  • Penela, D.
  • Martínez, M.
  • Linhart, M.
  • Andreu, D.
  • Fernández-Armenta, J.
  • Laguna, P.
  • Martínez, J.P.
  • Camara, O.
  • Berruezo, A.
Purpose: Activation mapping is used to guide ablation of idiopathic outflow tract ventricular arrhythmias (OTVAs). Isochronal activation maps help to predict the site of origin (SOO): left vs right outflow tract (OT). We evaluate an algorithm for automatic activation mapping based on the onset of the bipolar electrogram (EGM) signal for predicting the SOO and the effective ablation site in OTVAs. Methods: Eighteen patients undergoing ablation due to idiopathic OTVAs were studied (12 with left ventricle OT origin). Right ventricle activation maps were obtained offline with an automatic algorithm and compared with manual annotation maps obtained during the intervention. Local activation time (LAT) accuracy was assessed, as well as the performance of the 10 ms earliest activation site (EAS) isochronal area in predicting the SOO. Results: High correlation was observed between manual and automatic LATs (Spearman's: 0.86 and Lin's: 0.85, both p < 0.01). The EAS isochronal area were closely located in both map modalities (5.55 ± 3.56 mm) and at a similar distance from the effective ablation site (0.15 ± 2.08 mm difference, p = 0.859). The 10 ms isochronal area longitudinal/perpendicular diameter ratio measured from automatic maps showed slightly superior SOO identification (67% sensitivity, 100% specificity) compared with manual maps (67% sensitivity, 83% specificity). Conclusions: Automatic activation mapping based on the bipolar EGM onset allows fast, accurate and observer-independent identification of the SOO and characterization of the spreading of the activation wavefront in OTVAs.