Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 65
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Deep learning framework for real-time estimation of in-silico thrombotic risk indices in the left atrial appendage

  • Morales Ferez, Xabier
  • Mill, Jordi
  • Juhl, Kristine Aavild
  • Acebes Pinilla, César
  • Iriart, Xavier
  • Legghe, Benoit
  • Cochet, Hubert
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Patient-specific computational fluid dynamics (CFD) simulations can provide invaluable insight into the interaction of left atrial appendage (LAA) morphology, hemodynamics, and the formation of thrombi in atrial fibrillation (AF) patients. Nonetheless, CFD solvers are notoriously time-consuming and computationally demanding, which has sparked an ever-growing body of literature aiming to develop surrogate models of fluid simulations based on neural networks. The present study aims at developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), an in-silico index linked to the risk of thrombosis, typically derived from CFD simulations, solely from the patient-specific LAA morphology. To this end, a set of popular DL approaches were evaluated, including fully connected networks (FCN), convolutional neural networks (CNN), and geometric deep learning. While the latter directly operated over non-Euclidean domains, the FCN and CNN approaches required previous registration or 2D mapping of the input LAA mesh. First, the superior performance of the graph-based DL model was demonstrated in a dataset consisting of 256 synthetic and real LAA, where CFD simulations with simplified boundary conditions were run. Subsequently, the adaptability of the geometric DL model was further proven in a more realistic dataset of 114 cases, which included the complete patient-specific LA and CFD simulations with more complex boundary conditions. The resulting DL framework successfully predicted the overall distribution of the ECAP in both datasets, based solely on anatomical features, while reducing computational times by orders of magnitude compared to conventional CFD solvers., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme—FI (2020-FI-B-00690) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of the influence of pulmonary vein configuration on left atrial haemodynamics and thrombus formation in a large cohort

  • Mill, Jordi
  • Harrison, Josquin
  • Legghe, Benoit
  • Olivares, Andy L.
  • Morales, Xabier
  • Noailly, Jérôme
  • Iriart, Xavier
  • Cochet, Hubert
  • Sermesant, Maxime
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Moreover, the impact of structures such as the pulmonary veins (PVs) on LA haemodynamics has not been thoroughly studied due to the difficulties of acquiring appropriate data. On the other hand, in-silico studies and flow simulations allow a thorough analysis of haemodynamics, analysing the 4D nature of blood flow patterns under different boundary conditions. However, the reduced number of cases reported on the literature of these studies has been a limitation. The main goal of this work was to study the influence of PVs on left atrium (LA) and LAA haemodynamics. Computational fluid dynamics simulations were run on 52 patients, the largest cohort so far in the literature, where different parameters were individually studied: pulmonary veins orientation and configuration; LAA and LA volumes and its ratio; and flow velocities. Our computational analysis showed how the right pulmonary vein height and angulation have a great influence on LA haemodynamics. Additionally, we found that LAA with great bending with its tip pointing towards the mitral valve could contribute to favour flow stagnation., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496) and the European project PARIS (ID35).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Left atrial thrombus - Are all atria and appendages equal?

  • Cresti, Alberto
  • Camara, Oscar
Although the left atrial appendage (LAA) seems useless, it has several critical functions that are not fully known yet, such as the causes for being the main origin of cardioembolic stroke. Difficulties arise due to the extreme range of LAA morphologic variability, making the definition of normality challenging and hampering the stratification of thrombotic risk. Furthermore, obtaining quantitative metrics of its anatomy and function from patient data is not straightforward. A multimodality imaging approach, using advanced computational tools for their analysis, allows a complete characterization of the LAA to individualize medical decisions related to left atrial thrombosis patients., This work was supported by the Spanish Ministry of Economy and Competitiveness under the Retos Investigacion project (RTI2018-101193-B-I00) and by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Uncertainty assessment of proarrhythmia predictions derived from multi-level in silico models

  • Kopańska, Karolina
  • Rodríguez-Belenguer, Pablo
  • Llopis-Lorente, Jordi
  • Trenor, Beatriz
  • Saiz, Javier
  • Pastor Maeso, Manuel
In silico methods can be used for an early assessment of arrhythmogenic properties of drug candidates. However, their use for decision-making is conditioned by the possibility to estimate the predictions' uncertainty. This work describes our efforts to develop uncertainty quantification methods for the predictions produced by multi-level proarrhythmia models. In silico models used in this field usually start with experimental or predicted IC50 values that describe drug-induced ion channel blockade. Using such inputs, an electrophysiological model computes how the ion channel inhibition, exerted by a drug in a certain concentration, translates to an altered shape and duration of the action potential in cardiac cells, which can be represented as arrhythmogenic risk biomarkers such as the APD90. Using this framework, we identify the main sources of aleatory and epistemic uncertainties and propose a method based on probabilistic simulations that replaces single-point estimates predicted using multiple input values, including the IC50s and the electrophysiological parameters, by distributions of values. Two selected variability types associated with these inputs are then propagated through the multi-level model to estimate their impact on the uncertainty levels in the output, expressed by means of intervals. The proposed approach yields single predictions of arrhythmogenic risk biomarkers together with value intervals, providing a more comprehensive and realistic description of drug effects on a human population. The methodology was tested by predicting arrhythmogenic biomarkers on a series of twelve well-characterised marketed drugs, belonging to different arrhythmogenic risk classes., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. The authors received funding from the eTRANSAFE project, Innovative Medicines Initiative 2 Joint Undertaking under Grant Agreement No. 777365, supported from European Union’s Horizon 2020 and the EFPIA. Authors declare that this work reflects only the author’s view, and that IMI-JU is not responsible for any use that may be made of the information it contains. Also, this project received funding from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 964537 (RISK-HUNT3R), which is part of the ASPIS cluster. We also received funding from the SimCardioTest supported by European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 101016496. J.L.L. is being funded by the Ministerio de Ciencia, Innovacion y Universidades for the “Formacion de Profesorado Universitario” (Grant Reference: FPU18/01659). The work was also partially support by the Dirección General de Política Científica de la Generalitat Valenciana (PROMETEO/2020/043).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Impact of blood rheological strategies on the optimization of patient-specific LAAO configurations for thrombus assessment

  • Albors, Carlos
  • Olivares Miyares, Andy Luis
  • Iriart, Xavier
  • Cochet, Hubert
  • Mill, Jordi
  • Camara, Oscar
Comunicació presentada a 12th International Conference, Functional Imaging and Modeling of the Heart, FIMH 2023, celebrada del 19 al 22 de juny de 2023 a Lió, França., Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4–6% incidence of device-related thrombus (DRT). In-silico simulations can be used to estimate the risk of DRT and identify the critical parameters, such as suboptimal device positioning. However, simulation outcomes depend a lot on a series of modelling assumptions such as blood behaviour. Therefore, in this work, we present fluid simulations results computed on two patient-specific LA geometries, using two different commercially available LAAO devices, located in two positions: 1) mimicking the real post-LAAO intervention configuration; and 2) an improved one better covering the pulmonary ridge for DRT prevention. Different blood modeling strategies were also tested. The results show flow re-circulations at low velocities with significant platelet accumulation in LAA-deep device positioning uncovering the pulmonary ridge, potentially leading to thrombus formation. In addition, assuming Newtonian blood behaviour may result in an overestimation of DRT risk., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement, No 101016496 (SimCardioTest).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Digital twin integrating clinical, morphological and hemodynamic data to identify stroke risk factors

  • Saiz-Vivó, Marta
  • Mill, Jordi
  • Iriart, Xavier
  • Cochet, Hubert
  • Piella Fenoy, Gemma
  • Sermesant, Maxime
  • Camara, Oscar
Stroke remains a leading global cause of mortality, with ischemic stroke as the most common subtype. Atrial fibrillation (AF) increases ischemic stroke risk due to thrombus formation in the left atrium (LA), particularly in the left atrial appendage (LAA). Traditional risk assessments, like the CHA2DS2-VASc score, focus on clinical factors but often overlook LA morphology and hemodynamics. Existing studies either use mechanistic models with limited cases or rely solely on clinical data, missing hemodynamic insights. This study integrates statistical and mechanistic models within a Digital Twin framework, using unsupervised Multiple Kernel Learning on 130 AF patients. Combining LA morphology, hemodynamics, and clinical data improved patient stratification, identifying three phenogroups. The highest-risk group exhibited larger atrial dimensions, complex LAA structures, and elevated B-type natriuretic peptide levels. This study underscores the potential of Digital Twin models in assessing thrombus risk, emphasizing the need for further research to refine stroke prediction models., This project has received funding from the European Union’s Horizon 2020 research and innovation program under the grant agreements No 101016496 (SimCardioTest) and No 101136438 (GEMINI), as well as by the Spanish Ministry of Science, Innovation and Universities under the GENERALITAAT grant, (PID2022-143239OB-I00). GP’s contribution was supported by the ICREA Academia program.
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Unsupervised machine learning exploration of morphological and haemodynamic indices to predict thrombus formation in the left atrial appendage

  • Saiz-Vivó, Marta
  • Mill, Jordi
  • Harrison, Josquin
  • Jimenez-Perez, Guillermo
  • Legghe, Benoit
  • Iriart, Xavier
  • Cochet, Hubert
  • Piella Fenoy, Gemma
  • Sermesant, Maxime
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., Atrial Fibrillation (AF) is the most common cardiac arrhythmia, and it is associated with an increased risk of embolic stroke. It is known that AF-related thrombus formation occurs predominantly in the left atrial appendage (LAA). However, it is still unknown the structural and functional characteristics of the left atria (LA) that promote low velocities and stagnated blood flow, thus a high risk of thrombogenesis. In this work, we investigated morphological and in-silico haemodynamic indices of the LA and LAA with unsupervised machine learning (ML) techniques, to identify the most relevant features that could subsequently be used to generate thrombus prediction models. A fully automatic pipeline was implemented to extract multiple morphological parameters from a 3D mesh of a LA. Morphological parameters were then combined with particle flow parameters from in-silico fluid simulations. Unsupervised multiple kernel learning (MKL) was used for dimensionality reduction, resulting in a latent space positioning patients based on feature similarity. Clustering applied to the MKL output space estimated clusters with different proportion of thrombus cases. The cluster with the highest risk of thrombus formation was characterised by high values of LAA height, tortuosity and ostium perimeter, as well as total number of flow particles in the LAA and low angle between the LAA and the left superior pulmonary vein, proving the usefulness of unsupervised ML techniques to extract knowledge from the data, and early identify AF patients at higher risk of thrombus formation., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 101016496 (SimCardioTest).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Geometric deep learning for the assessment of thrombosis risk in the left atrial appendage

  • Morales, Xabier
  • Mill, Jordi
  • Simeon, Guillem
  • Juhl, Kristine Aavild
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., The assessment of left atrial appendage (LAA) thrombogenesis has experienced major advances with the adoption of patient-specific computational fluid dynamics (CFD) simulations. Nonetheless, due to the vast computational resources and long execution times required by fluid dynamics solvers, there is an ever-growing body of work aiming to develop surrogate models of fluid flow simulations based on neural networks. The present study builds on this foundation by developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), linked to the risk of thrombosis, solely from the patient-specific LAA geometry. To this end, we leveraged recent advancements in Geometric DL, which seamlessly extend the unparalleled potential of convolutional neural networks (CNN), to non-Euclidean data such as meshes. The model was trained with a dataset combining 202 synthetic and 54 real LAA, predicting the ECAP distributions instantaneously, with an average mean absolute error of 0.563. Moreover, the resulting framework manages to predict the anatomical features related to higher ECAP values even when trained exclusively on synthetic cases., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Sensitivity analysis of left atrial wall modeling approaches and inlet/outlet boundary conditions in fluid simulations to predict thrombus formation

  • Albors, Carlos
  • Mill, Jordi
  • Kjeldsberg, Henrik A
  • Viladés-Medel, David
  • Olivares Miyares, Andy Luis
  • Valen-Sendstad, Kristian
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., In-silico fluid simulations of the left atria (LA) in atrial fibrillation (AF) patients can help to describe and relate patient-specific morphologies and complex flow haemodynamics with the pathophysiological mechanisms behind thrombus formation. Even in AF patients, LA wall motion plays a non-negligible role in LA function and blood flow patterns. However, obtaining 4D LA wall dynamics from patient-specific data is not an easy task due to current image resolution limitations. Therefore, several approaches have been proposed in the literature to include left atrial wall motion in fluid simulations, being necessary to benchmark them in relation to their estimations on thrombogenic risk. In this work, we present results obtained with computational fluid dynamic simulations of LA geometries from a control and an AF patient with different left atrial wall motion approaches: 1) assuming rigid walls; 2) with a passive movement of the mitral valve annulus plane from a dynamic mesh approach based on springs (DM-SB); and 3) imposing LA wall deformation extracted from dynamic computed tomography (DM-dCT) images. Different strategies for the inlet/outlet boundary conditions were also tested. The DM-dCT approach was the one providing simulation results closer to velocity curves extracted from the reference echocardiographic data, whereas the rigid wall strategy over-estimated the risk of thrombus formation., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 101016496 (SimCardioTest).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

The role of the pulmonary veins on left atrial flow patterns and thrombus formation

  • Mill, Jordi
  • Harrison, Josquin
  • Saiz-Vivó, Marta
  • Albors, Carlos
  • Morales, Xabier
  • Olivares, Andy L.
  • Iriart, Xavier
  • Cochet, Hubert
  • Noailly, Jérôme
  • Sermesant, Maxime
  • Camara, Oscar
Atrial fibrillation (AF) is the most common human arrhythmia, forming thrombi mostly in the left atrial appendage (LAA). However, the relation between LAA morphology, blood patterns and clot formation is not yet fully understood. Furthermore, the impact of anatomical structures like the pulmonary veins (PVs) have not been thoroughly studied due to data acquisition difficulties. In-silico studies with flow simulations provide a detailed analysis of blood flow patterns under different boundary conditions, but a limited number of cases have been reported in the literature. To address these gaps, we investigated the influence of PVs on LA blood flow patterns and thrombus formation risk through computational fluid dynamics simulations conducted on a sizeable cohort of 130 patients, establishing the largest cohort of patient-specific LA fluid simulations reported to date. The investigation encompassed an in-depth analysis of several parameters, including pulmonary vein orientation (e.g., angles) and configuration (e.g., number), LAA and LA volumes as well as their ratio, flow, and mass-less particles. Our findings highlight the total number of particles within the LAA as a key parameter for distinguishing between the thrombus and non-thrombus groups. Moreover, the angles between the different PVs play an important role to determine the flow going inside the LAA and consequently the risk of thrombus formation. The alignment between the LAA and the main direction of the left superior pulmonary vein, or the position of the right pulmonary vein when it exhibits greater inclination, had an impact to distinguish the control group vs. the thrombus group. These insights shed light on the intricate relationship between PV configuration, LAA morphology, and thrombus formation, underscoring the importance of comprehensive blood flow pattern analyses., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00) and GENERALITAAT (PID2022-143239OB-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Sensitivity analysis of in silico fluid simulations to predict thrombus formation after left atrial appendage occlusion

  • Mill, Jordi
  • Agudelo, Victor
  • Olivares Miyares, Andy Luis
  • Pons Vidal, Maria Isabel
  • Silva, Etelvino
  • Nuñez-Garcia, Marta
  • Morales Ferez, Xabier
  • Arzamendi, Dabit
  • Freixa, Xavier
  • Noailly, Jérôme
  • Camara, Oscar
Atrial fibrillation (AF) is nowadays the most common human arrhythmia and it is considered a marker of an increased risk of embolic stroke. It is known that 99% of AF-related thrombi are generated in the left atrial appendage (LAA), an anatomical structure located within the left atrium (LA). Left atrial appendage occlusion (LAAO) has become a good alternative for nonvalvular AF patients with contraindications to anticoagulants. However, there is a non-negligible number of device-related thrombus (DRT) events, created next to the device surface. In silico fluid simulations can be a powerful tool to better understand the relation between LA anatomy, haemodynamics, and the process of thrombus formation. Despite the increasing literature in LA fluid modelling, a consensus has not been reached yet in the community on the optimal modelling choices and boundary conditions for generating realistic simulations. In this line, we have performed a sensitivity analysis of several boundary conditions scenarios, varying inlet/outlet and LA wall movement configurations, using patient-specific imaging data of six LAAO patients (three of them with DRT at follow-up). Mesh and cardiac cycle convergence were also analysed. The boundary conditions scenario that better predicted DRT cases had echocardiography-based velocities at the mitral valve outlet, a generic pressure wave from an AF patient at the pulmonary vein inlets, and a dynamic mesh approach for LA wall deformation, emphasizing the need for patient-specific data for realistic simulations. The obtained promising results need to be further validated with larger cohorts, ideally with ground truth data, but they already offer unique insights on thrombogenic risk in the left atria., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Towards real-time optimization of left atrial appendage occlusion device placement through physics-informed neural networks

  • Morales, Xabier
  • Albors, Carlos
  • Mill, Jordi
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., The adoption of patient-specific computational fluid dynamics (CFD) simulations has been instrumental toward a better understanding of the mechanisms underlying thrombogenesis in the left atrial appendage. Such simulations can help optimize the placement of left atrial appendage occlusion (LAAO) devices in atrial fibrillation patients and avoid the generation of device-related thrombosis. However, integrating conventional solvers into clinical practice is cumbersome, as even the slightest change in model geometry involves computing the entire simulation from scratch. In contrast, neural networks can entirely circumvent this issue by transferring knowledge across models targeted at similar physical domains. Thus, in the present study, we introduced a neural network capable of predicting left atrial hemodynamics under different occlusion device configurations, relying solely on a single finite element simulation for training. To this end, we leveraged physics-informed neural networks (PINN), which embed the physical laws governing the domain of interest into the model, exhibiting far superior generalization capabilities than conventional data-driven models. Several device types and positions have been tested in two distinct left atrial geometries. By employing a single reference simulation per patient the network can predict the updated hemodynamics for a variety of device types and positions, orders of magnitude faster than with conventional CFD solvers., This work was funded by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme - FI (2020 FI_B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and the Retos Investigación project (RTI2018-101193-B-I00), and the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496). Additionally, this research was supported by grants from NVIDIA and utilized NVIDIA RTX A6000.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Cardiomyopathy and thrombogenesis in cats through left atrial morphological and fluid dynamics analysis

  • Pons Vidal, Maria Isabel
  • Olivares, Andy L.
  • Mill, Jordi
  • Novo Matos, Jose
  • García Cañadilla, Patricia, 1985-
  • Cerrada, Inma
  • Guy, Anna
  • Morales Ferez, Xabier
  • Hutchinson, John Ciaran
  • Simcock, Ian C.
  • Arthurs, Owen J.
  • Cook, Andrew C.
  • Luis Fuentes, Virginia
  • Camara, Oscar
The relationship between atrial fibrillation (AF), blood flow disturbances and thrombus formation is well-established in humans. Thrombi primarily form in the left atrial appendage (LAA), but the specific role of LAA morphology remains unclear. Felines, despite rarely experiencing AF, present a valuable model for studying human heart diseases. Cats exhibit a high incidence of cardiomyopathies, often accompanied by significant left atrial dilation and thrombus formation. This unique aspect prompts research focusing on LAA morphology and function in relation to thrombus development. Our study, using advanced image processing and fluid simulations on 24 cat hearts ranging from normal to cardiomyopathy subjects, aims to find distinctions in left atrium (LA) and LAA morphologies, blood flow patterns and their relation to thrombus formation. Significantly different variables in feline heart groups included: heart weight, LAA volume, LA volume, ostium area, ostium area-to-heart weight ratio, centreline length and velocity at the LAA ostium. Fluid simulations revealed lower LAA blood flow velocities and increased thrombotic risk in cases with thrombi. Our study enhances the understanding of LAA structure and function, offering insights into thrombus formation mechanisms with potential implications for better managing thrombosis risk in patients., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación projects VIROLAAI and GENERALITAAT (RTI2018-101193-B-I00, PID2022-143239OB-I00). Furthermore, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; Grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

In silico estimation of thrombogenic risk after left atrial appendage excision: towards digital twins in atrial fibrillation

  • Albors, Carlos
  • Arrarte Terreros, Nerea
  • Saiz-Vivó, Marta
  • Zappala, Pietro
  • Terpstra, Marc M.
  • Olivares Miyares, Andy Luis
  • Planken, R. Nils
  • van Boven, WimJan P.
  • Driessen, Antoine H. G.
  • de Groot, Joris R.
  • Camara, Oscar
Background & aim: The left atrial appendage (LAA) is a highly variable, pouch-like structure in the left atrium prone to thrombus formation, especially in atrial fibrillation (AF) patients. In silico cardiac models can help characterize the LAA's complex morphology and hemodynamics, aiding in identifying pro-thrombotic areas. This study assessed atrial hemodynamics and thrombus formation risk after LAA excision and compared with optimal synthetic excisions and occluder placements in high thrombogenic-risk cases. Methods: We included 33 patients from the MARK-AF study who had persistent AF and underwent excision of the LAA. We quantified the morphological characteristics of the post-excision LAA remnant. With patient-specific atrial geometries and boundary conditions, in silico blood flow simulations were performed. For each patient, we quantified multiple in silico indices to characterize blood flow patterns and identify thrombogenic regions. We performed an in silico comparison of different LAA treatment approaches. Results: In our cohort, 25/33 (76 %) of patients had a post-excision, protruding LAA remnant (LAA depth >10 mm). In silico simulations indicated that patients with a protruding remnant more frequently showed unfavorable values for in silico indices associated with high thrombogenic risk at the excision site. However, a prominent LAA remnant was not the only factor associated with a high thrombogenic risk. An optimal excision or optimal occluder device placement reduced thrombus formation risk. Conclusion: The combination of LAA remnant morphology and hemodynamics contributed to thrombus formation risk. Advanced in silico simulations uniquely enabled the comparison of different therapies, until now only centered on device occluders, contributing to digital twins in AF., This work was supported by the Spanish Ministry of Science, Innovation and Universities GENERALITAAT (PID2022-143239OB-I00) grant, the European Horizon 2020 SimCardioTest (ID 101016496) project, the Horizon 2024 GEMINI (ID 101136438) project, the Distinguished Women Scientist Fund and the Amsterdam University Medical Centers Women in Science Fund.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Impact of left atrial wall motion assumptions in fluid simulations on proposed predictors of thrombus formation

  • Kjeldsberg, Henrik A.
  • Albors, Carlos
  • Mill, Jordi
  • Viladés-Medel, David
  • Camara, Oscar
  • Sundnes, Joakim
  • Valen-Sendstad, Kristian
Atrial fibrillation (AF) poses a significant risk of stroke due to thrombus formation, which primarily occurs in the left atrial appendage (LAA). Medical image-based computational fluid dynamics (CFD) simulations can provide valuable insight into patient-specific hemodynamics and could potentially enhance personalized assessment of thrombus risk. However, the importance of accurately representing the left atrial (LA) wall dynamics has not been fully resolved. In this study, we compared four modeling scenarios; rigid walls, a generic wall motion based on a reference motion, a semi-generic wall motion based on patient-specific motion, and patient-specific wall motion based on medical images. We considered a LA geometry acquired from 4D computed tomography during AF, systematically performed convergence tests to assess the numerical accuracy of our solution strategy, and quantified the differences between the four approaches. The results revealed that wall motion had no discernible impact on LA cavity hemodynamics, nor on the markers that indicate thrombus formation. However, the flow patterns within the LAA deviated significantly in the rigid model, indicating that the assumption of rigid walls may lead to errors in the estimated risk factors. In contrast, the generic, semi-generic, and patient-specific cases were qualitatively similar. The results highlight the crucial role of wall motion on hemodynamics and predictors of thrombus formation, and also demonstrate the potential of using a generic motion model as a surrogate for the more complex patient-specific motion. While the present study considered a single case, the employed CFD framework is entirely open-source and designed for adaptability, allowing for integration of additional models and generic motions., This research was funded, in whole or in part, by The Research Council of Norway through the PARIS project (311117) and by ERACoSysMed under grant agreement no. 643271. We also acknowledge funding by the SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020) under grant agreement no. 101016496. Simulations were performed on the Saga cluster, with resources provided by UNINETT Sigma2—the National Infrastructure for High Performance Computing and Data Storage in Norway, grant number nn9249k, and on the Oracle HPC Cluster stack through Oracle Cloud credits and related resources provided by Oracle for Research.
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of device-related thrombosis for different left atrial appendage occluder settings

  • Planas, Eric
  • Mill, Jordi
  • Olivares, Andy L.
  • Morales, Xabier
  • Pons Vidal, Maria Isabel
  • Iriart, Xavier
  • Cochet, Hubert
  • Camara, Oscar
Comunicació presentada a: 12th International Workshop, STACOM 2021 celebrada del 27 de setembre de 2021 a Strasbourg, França., Atrial fibrillation (AF) is one of the most common cardiac arrhythmias and is associated to an increasing risk of stroke. Most AF- related strokes are formed in the left atrial appendage (LAA). To prevent thrombus formation, LAA occlusion (LAAO) is considered a suitable alternative for AF patients with contraindications for anti-coagulation treatment. Nevertheless, LAAO is linked to a non-negligible risk of gener- ating thrombus at the surface near the device (i.e., device-related throm- bus, DRT), depending on the implantation settings. For instance, it has been shown that not covering the pulmonary ridge (PR) with the LAAO increases the risk of DRT. In-silico analysis is a useful tool to better understand the blood flow patterns after LAAO and predict the risk of DRT for a given patient and device configuration. In the present work we designed a modelling pipeline based on fluid simulations, including a thrombus model using discrete phase modelling, to analyse the risk of DRT in six patient-specific geometries for different LAAO settings. In particular, we studied the possible incidence of DRT depending on the device positioning (covering/uncovering the PR) and type (Amplatzer Amulet and Watchman FLX). The resulting in-silico indices demon- strated that covering the PR entails less thrombogenic patterns than uncovering it. In our study, disk-based devices had better adaptability to complex LAA morphologies and a slightly minor associated risk of DRT than non-disk devices., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Inves- tigaci ́on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi
  • Montoliu, Helena
  • Moustafa, Abdel-Hakim
  • Olivares, Andy L.
  • Albors, Carlos
  • Aguado, Ainhoa M.
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier
  • Arzamendi, Dabit
  • Cochet, Hubert
  • Camara, Oscar
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM 2015-0502), and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062). In addition, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus

  • Albors, Carlos
  • Mill, Jordi
  • Olivares Miyares, Andy Luis
  • Iriart, Xavier
  • Cochet, Hubert
  • Camara, Oscar
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation., This work was supported by the European Union’s Horizon 2020 research and innovation program SimCardioTest (101016496 to OC), by the programm GEMINI (GA 101136438), and by the Spanish Ministry of Science, Innovation and Universities under the GENERALITAAT, (PID2022-143239OB-I00 to OC). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Automated 4D flow MRI pipeline for the quantification of advanced hemodynamic parameters in the left atrium

  • Morales, Xabier
  • Elsayed, Ayah
  • Zhao, Debbie
  • Loncaric, Filip
  • Aguado, Ainhoa M.
  • Masias Bruns, Mireia
  • Quill, Gina M.
  • Ramos, Marc
  • Doltra, Adelina
  • Garcia-Alvarez, Ana
  • Sitges, Marta
  • Marlevi, David
  • Young, Alistair A.
  • Nash, Martyn P.
  • Bijnens, Bart
  • Camara, Oscar
The left atrium (LA) plays a pivotal role in modulating left ventricular filling, yet its hemodynamics remain poorly understood due to the limitations of conventional ultrasound analysis. Four-dimensional flow magnetic resonance imaging (4D Flow MRI) holds promise for enhancing our understanding of atrial hemodynamics, but its analysis is hindered by the inherently low velocities within the chamber and the modest spatial resolution of 4D Flow MRI. Heterogeneity in acquisition protocols and MRI vendors, and the lack of standardized computational frameworks further complicates the creation of large, comparable datasets needed to assess the prognostic value of hemodynamic markers provided by 4D Flow MRI. To address these challenges, we introduce a computational framework tailored to the analysis of 4D Flow MRI in the LA, enabling the qualitative and quantitative analysis of advanced hemodynamic parameters (e.g., kinetic energy, vorticity, and pressure). We applied this framework to a diverse cohort spanning different degrees of left ventricular diastolic dysfunction to investigate the prognostic potential of these metrics. Our framework proved robustness across multicenter data of varying quality, producing high-accuracy automated segmentations. Notably, our findings show that 4D Flow MRI-derived parameters provide superior differentiation between healthy and pathological states than those available to conventional hemodynamic analysis tools., This study was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme - FI (2020 FI_B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (PID2022-143239OB-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital Transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496). This research was also supported by grants from NVIDIA and utilized NVIDIA RTX A6000. Data collection and analysis at the University of Auckland is supported by the Health Research Council of New Zealand (program grant 17/608). Funded also by Instituto de Salud Carlos III, Gobierno de España grant FIS PI21/00905 and Hospital Clinic, Premi Emili Letang-Josep Font (MR). D.M. acknowledges funding from the European Union (ERC, MultiPRESS, 101075494). Views and opinions expressed are those of the authors and do not reflect those of the European Union or the European Research Council Executive Agency.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

In silico systematic evaluation of the scar effect in conventional and new cardiac resynchronization therapy approaches

  • Ruiz, Cristóbal Rubén
  • Gómez, Juan F.
  • Osca, Joaquín
  • Izquierdo, Maite
  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
[EN] Objective: Cardiac resynchronization therapy (CRT) is a technique used in the clinical setting to solve dyssynchronization problems in ventricular contraction. The goal of this study was to evaluate in silico the performance of conventional and new CRT approaches under left bundle branch block (LBBB) and heart failure (HF) conditions, and especially under myocardial scar presence. Methods: The simulations were run in a 3D realistic biventricular model including the His-Purkinje system, where the different pathologies were modeled. Stimulation protocols corresponding to each of the CRT approaches assessed were applied. Importantly, the presence of infarcted tissue was systematically evaluated according to the American Heart Association segmentation of the heart. To assess CRT performance, a set of six biomarkers obtained from simulated ECG signals and activation maps was defined. Results: Our simulations showed that under LBBB and HF conditions with or without infarction scar, the newer CRT approaches performed better. Interestingly, the inclusion of scarred tissue in some basal and septal segments had detrimental effects on the biomarkers that particularly worsened when Purkinje fibers were considered as non-conductive. Conclusions: This study sheds light on the effects that several heart disruptions have in cardiac activation before and after traditional and newest CRT methods. Moreover, the utilization of fusion pacing and Purkinje fibers survivability post-infarction, has demonstrated an improvement in the overall outcome of CRT. Significance: In silico models could constitute a powerful tool to understand, evaluate, and optimize different CRT approaches, which could help clinicians to plan personalized CRT procedures and reduce patient's risk., This work was supported by Grant PID2019-104356RB-C41 funded by MCIN/AEI/10.13039/501100011033, by Grants PID2022-136273OA-C33 and PID2022-140553OB-C41 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU, and by the European Union's Horizon 2020 research and innovation program under grant agreement No 101016496 (SimCardioTest) . The authors also thankfully acknowledge the computer resources at MareNostrum (IM-2021-1-0001, IM-2021-1-0003, IM-2022-1-0002, IM-2023-1-0002) and MareNostrum5 (IM-2024-1-0010 and IM-2024-2-0015) and the technical support provided by Barcelona Supercomputing Center.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Experimentally Validated Modeling of Dynamic Drug-hERG Channel Interactions Reproducing the Binding Mechanisms and its Importance in Action Potential Duration

  • Escobar-Ropero, Fernando|||0000-0001-7602-447X
  • Gomis-Tena Dolz, Julio|||0000-0002-1309-2368
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Friis, Soren
  • Adly, Nouran
  • Brinkwirth, Nina
  • Arne Klaerke, Dan
  • Stoelzle-Feix, Sonja
Background and Objective: Assessment of drug cardiotoxicity is critical in the development of new compounds and modeling of drug-binding dynamics to hERG can improve early cardiotoxicity assessment. We previously developed a methodology to generate Markovian models reproducing preferential state-dependent binding properties, trapping dynamics and the onset of IKr block using simple voltage clamp protocols. Here, we test this methodology with real IKr blockers and investigate the impact of drug dynamics on action potential prolongation. Methods: Experiments were performed on HEK cells stably transfected with hERG and using the Nanion SyncroPatch 384i. Three protocols, P-80, P0 and P40, were applied to obtain the experimental data from the drugs and the Markovian models were generated using our pipeline. The corresponding static models were also generated and a modified version of the O´Hara-Rudy action potential model was used to simulate the action potential duration. Results: The experimental Hill plots and the onset of IKr block of ten compounds were obtained using our voltage clamp protocols and the models generated successfully mimicked these experimental data, unlike the CiPA dynamic models. Marked differences in APD prolongation were observed when drug effects were simulated using the dynamic models and the static models. Conclusions: These new dynamic models of ten well-known IKr blockers constitute a validation of our methodology to model dynamic drug–hERG channel interactions and highlight the importance of state-dependent binding, trapping dynamics and the time-course of IKr block to assess drug effects even at the steady-state.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Tesis doctoral (DoctoralThesis)

Prediction of Drug-Induced Proarrhythmic Risk through Modelling and Simulation of Cardiac Electrophysiological Activity

  • Llopis Lorente, Jordi
[ES] La Torsade de Pointes (TdP) es una arritmia ventricular grave y potencialmente mortal. Este tipo de arritmia puede aparecer por diversas causas, siendo una de las más relevantes la toma de medicamentos. La TdP inducida por fármacos constituye un reto en seguridad farmacológica, llegando a ser responsable de la retirada de muchos fármacos del mercado. Por ello, realizar una correcta predicción del riresgo proarrítmico de los fármacos es crucial para la seguridad de los pacientes. Aunque los métodos actuales de evaluación del riesgo de TdP son eficaces, resultan costosos y presentan limitaciones. En los últimos años, las simulaciones cardíacas in silico han surgido como herramientas prometedoras para mejorar la evaluación farmacológica, complementando los métodos de evaluación actuales y mejorando la eficiencia y la precisión. El objetivo principal de esta tesis doctoral ha sido desarrollar herramientas computacionales para mejorar la predicción del riesgo proarrítmico inducido por fármacos. La metodología se ha basado principalmente en una versión modificada del modelo computacional del potencial de acción ventricular de O'Hara. En primer lugar, este modelo in silico se utilizó para simular los efectos de 109 fármacos y analizar distintos biomarcadores como Tx, TqNet, Ttriang y TEAD con el fin de construir herramientas de predicción de TdP. En segundo lugar, se estudió el papel de la variabilidad electrofisiológica. Para ello, se construyó una población de más de 800 modelos electrofisiológicos para simular las diferencias interindividuales en la respuesta a la exposición a fármacos y se desarrolló un clasificador ternario basado en Máquinas de Vectores de Soporte. Finalmente, se analizó el impacto del sexo y la función renal mediante la integración de modelos farmacocinéticos (PK) y una población de modelos electrofisiológicos (EP) de 300 hombres y 300 mujeres. El clasificador binario basado en árboles de decisión, que combina los biomarcadores Tx, TqNet, Ttriang, logró un accuracy del 94,5%, superando los resultados de la prueba utilizada actualmente por las agencias reguladoras, el test hERG IC50, que obtuvo un accuracy del 78,9%. Además, el estudio identificó que los cambios en las corrientes iónicas IKr, ICaL, INaL e IKs fueron los principales responsables del riesgo de TdP. A partir de estos hallazgos, se desarrolló una herramienta web basada en más de 450 000 simulaciones que ofrece la posibilidad de evaluar el riesgo proarrítmico de un fármaco de forma rápida y sencilla. Por otro lado, el clasificador ternario que consideraba la variabilidad interindividual aumentó la accuracy de la predicción de riesgo de TdP en más de un 20% en comparación con el clasificador sin variabilidad interindividual. Respecto al efecto del sexo y la función renal, las simulaciones evidenciaron que las mujeres con función renal alterada presentan mayor susceptibilidad a las arritmias inducidas por fármacos. Además, la metodología propuesta integrando los modelos PK y EP ayudó a determinar los regímenes de máxima dosis segura para subgrupos específicos de pacientes. Además, como prueba de concepto, también se realizaron simulaciones en 3D de los efectos del dofetilide, obteniendo prolongaciones del intervalo QT similares a los datos clínicos publicados. En conclusión, las metodologías desarrolladas en esta tesis doctoral mejoran la predicción del riesgo de TdP inducida por fármacos, contribuyendo al desarrollo de medicamentos más seguros y a estrategias de tratamiento más personalizadas. Los resultados presentados demuestran el impacto que pueden tener las herramientas in silico en el avance de las evaluaciones de seguridad farmacológica. Además, se espera que los hallazgos de esta tesis doctoral abran nuevas vías para futuras investigaciones en el ámbito de las simulaciones cardiacas in silico, lo que en última instancia conducirá a mejores evaluaciones de seguridad cardíaca y a una mayor seguridad farmacológica en general., [CA] La Torsade de Pointes (TdP) és una arrítmia ventricular greu i potencialment mortal. Este tipus d'arrítmia pot aparèixer per diverses causes, sent una de les més rellevants l'administració de medicaments. La TdP induïda per fàrmacs representa un repte en l'àmbit de la seguretat farmacològica, ja que ha sigut responsable de la retirada de molts fàrmacs del mercat. Per això, realitzar una correcta predicció del risc proarrítmic dels fàrmacs és crucial per a la seguretat dels pacients. Encara que els mètodes actuals d'avaluació del risc de TdP són eficaços, resulten costosos i presenten limitacions per a reflectir les complexes interaccions entre els fàrmacs i el teixit cardíac en determinades situacions. En els últims anys, les simulacions cardíaques in silico han sorgit com a eines prometedores per a millorar l'avaluació farmacològica, complementant els mètodes actuals i augmentant l'eficiència i la precisió. L'objectiu d'aquesta tesi doctoral ha sigut desenvolupar eines computacionals per a millorar la predicció del risc proarrítmic induït per fàrmacs. La metodologia s'ha basat en una versió modificada del model de potencial d'acció ventricular d'O'Hara. En primer lloc, aquest model in silico es va utilitzar per a simular els efectes de 109 fàrmacs amb riscos torsadogènics coneguts i analitzar biomarcadors com Tx, TqNet, Ttriang i TEAD, per a construir eines de predicció de TdP. En segon lloc, es va estudiar el paper de la variabilitat electrofisiològica. Per a això, es va construir una població de més de 800 models electrofisiològics amb l'objectiu de simular les diferències interindividuals en la resposta als fàrmacs, i es va desenvolupar un classificador ternari basat en Màquines de Vectors de Suport (SVM). Finalment, es va analitzar l'impacte del sexe i la funció renal en el risc de TdP, mitjançant la integració de models farmacocinètics (PK) amb una població de models electrofisiològics (EP) de 300 homes i 300 dones. El classificador binari basat en arbres de decisió, que combinava els biomarcadors Tx, TqNet i Ttriang, va aconseguir una accuracy del 94,5%, superant la prova utilitzada actualment per les agències reguladores, el test hERG IC50, que va obtindre un 78,9% de accuracy. A més, aquest estudi va identificar que els canvis en les corrents iòniques IKr, ICaL, INaL i IKs són els principals determinants del risc de TdP. A partir d'aquests resultats, es va desenvolupar una eina web basada en més de 450 000 simulacions que permet una avaluació ràpida i senzilla del risc proarrítmic d'un fàrmac. D'altra banda, el classificador ternari que considerava la variabilitat interindividual va augmentar l'accuracy de la predicció de TdP en més d'un 20% en comparació amb el classificador sense variabilitat interindividual. Pel que fa a l'efecte del sexe i la funció renal, les simulacions van evidenciar que les dones amb funció renal deteriorada són més susceptibles a les arrítmies induïdes per fàrmacs. A més, la metodologia proposta basada en la integració de models PK i EP, va ajudar a determinar els règims de màxima dosi segura per a subgrups específics de pacients. A més, com a prova de concepte, també es van realitzar simulacions 3D dels efectes del dofetilide, obtenint prolongacions de l'interval QT similars a les dades clíniques reportades. En conclusió, les metodologies desenvolupades en aquesta tesi doctoral milloren la predicció del risc de TdP induït per fàrmacs, contribuint a un desenvolupament de medicaments més segurs i a estratègies terapèutiques més personalitzades. Els resultats presentats demostren l'impacte que poden tenir les eines in silico en el progrés de les avaluacions de seguretat farmacològica. A més, s'espera que els resultats d'aquesta tesi doctoral òbriguen noves vies per a futures investigacions en l'àmbit de les simulacions cardíaques in silico, la qual cosa, en última instància, conduirà a millors avaluacions de seguretat cardíaca i a una major seguretat farmacològica en general., [EN] Torsade de Pointes (TdP) is a severe and potentially life-threatening ventricular arrhythmia. This type of arrhythmia can occur due to various causes, one of the most relevant being the administration of certain medications. Drug-induced TdP represents a significant challenge in the field of drug safety, as it has been responsible for the withdrawal of numerous drugs from the market. Therefore, accurate prediction of the proarrhythmic potential of drugs is crucial for patient safety. While current TdP risk assessment methods are effective, they are expensive and have limitations in capturing the complex interactions between drugs and cardiac tissue in certain scenarios. In recent years, in silico cardiac simulations have emerged as promising tools for improving drug evaluation, complementing existing methods, and enhancing both efficiency and accuracy. This PhD thesis aims to develop computational tools to improve the prediction of drug-induced proarrhythmic risk. The methodology is primarily based on a modified version of the O'Hara and colleagues' ventricular action potential model. First, this in silico model was used to simulate the effects of 109 drugs with known torsadogenic risks and to analyse biomarkers such as Tx, TqNet, Ttriang, and TEAD, enabling the development of TdP prediction tools. Second, the role of electrophysiological variability in TdP risk assessment was studied. A population of over 800 electrophysiological models was constructed to simulate inter-individual differences in drug response, and a ternary classifier was developed using Support Vector Machines (SVM). Finally, the impact of sex and renal function on drug-induced TdP risk was analysed by integrating pharmacokinetic (PK) models with a population of electrophysiological (EP) models of 300 males and 300 females. The binary decision-tree classifier that combined the biomarkers Tx, TqNet, and Ttriang achieved an accuracy of 94.5%, outperforming the current regulatory test, hERG IC50, which reached an accuracy of 78.9%. Additionally, the study identified that changes in the IKr, ICaL, INaL, and IKs currents were the primary determinants of TdP risk. These findings led to the development of a web-based tool based on over 450 000 simulations, offering a rapid and straightforward assessment of the proarrhythmic risk of a compound. Furthermore, the ternary classifier that incorporates inter-individual variability increased TdP risk prediction accuracy by more than 20% compared to the classifier that did not consider inter-individual variability. Regarding sex and renal function, simulations demonstrated that women with impaired renal function were more susceptible to drug-induced arrhythmias. The proposed PK/EP model integration also helped determine the maximum safe dosing regimens for specific patient subgroups. In addition, as a proof of concept, 3D simulations of dofetilide were performed, yielding QT prolongations consistent with reported clinical data. In conclusion, the methodologies developed in this PhD thesis enhance the prediction of drug-induced TdP risk, contributing to safer drug development and more personalized treatment strategies. The results highlight the impact in silico tools can have on advancing cardiac safety assessments. Furthermore, these findings are expected to pave the way for future research aimed at refining in silico cardiac simulations, ultimately leading to improved cardiac safety evaluations and enhanced overall drug safety., This work was partially supported by the Dirección general de Política Científica de la Generalitat Valenciana (PROMETEU2020/043); by “Primeros Proyectos de Investigación” (PAID-06-18) from Vicerrectorado de Investigación, Innovación y Transferencia de la Universitat Politècnica de València (UPV), València, Spain; as well as from the “Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020” from the Ministerio de Ciencia e Innovación y Universidades (PID2019-104356RB-C41/AEI710.13039/501100011033). J.L.L. is being funded by the Ministerio de Ciencia, Innovación y Universidades for the “Formación de Profesorado Universitario” (grant reference: FPU18/01659). This project received funding from the European Union’s Horizon 2020 Research and Innovation Program under grant agreement No. 101016496 (SimCardioTest). The authors also thankfully acknowledge the computer resources at MareNostrum and the technical support provided by Barcelona Supercomputing Center (IM-2021-1-0001, IM-2021-1-0003, IM-2022-1-0002, IM-2023-1-0002). JL is being funded by the Ministerio de Ciencia, Innovación y Universidades for the Formación de Profesorado Universitario (grant reference: FPU18/01659). Funding for open access charge: Universitat Politècnica de València
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Arrhythmogenic Effects of Genetic Mutations Affecting Potassium Channels in Human Atrial Fibrillation: A Simulation Study

  • Belletti, Rebecca
  • Martínez-Mateu, Laura
  • Cherry, Elizabeth M.
  • Fenton, Flavio H.
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Genetic mutations in genes encoding for potassium channel protein structures have been recently associated with episodes of atrial fibrillation in asymptomatic patients. The aim of this study is to investigate the potential arrhythmogenicity of three gain-of-function mutations related to atrial fibrillation¿namely, KCNH2 T895M, KCNH2 T436M, and KCNE3-V17M¿using modeling and simulation of the electrophysiological activity of the heart. A genetic algorithm was used to tune the parameters¿ value of the original ionic currents to reproduce the alterations experimentally observed caused by the mutations. The effects on action potentials, ionic currents, and restitution properties were analyzed using versions of the Courtemanche human atrial myocyte model in different tissues: pulmonary vein, right, and left atrium. Atrial susceptibility of the tissues to spiral wave generation was also investigated studying the temporal vulnerability. The presence of the three mutations resulted in an overall more arrhythmogenic substrate. Higher current density, action potential duration shortening, and flattening of the restitution curves were the major effects of the three mutations at the single-cell level. The genetic mutations at the tissue level induced a higher temporal vulnerability to the rotor¿s initiation and progression, by sustaining spiral waves that perpetuate until the end of the simulation. The mutation with the highest pro-arrhythmic effects, exhibiting the widest sustained VW and the smallest meandering rotor¿s tip areas, was KCNE3-V17M. Moreover, the increased susceptibility to arrhythmias and rotor¿s stability was tissue-dependent. Pulmonary vein tissues were more prone to rotor¿s initiation, while in left atrium tissues rotors were more easily sustained. Re-entries were also progressively more stable in pulmonary vein tissue, followed by the left atrium, and finally the right atrium. The presence of the genetic mutations increased the susceptibility to arrhythmias by promoting the rotor¿s initiation and maintenance. The study provides useful insights into the mechanisms underlying fibrillatory events caused by KCNH2 T895M, KCNH2 T436M, and KCNE3-V17M and might aid the planning of patient-specific targeted therapies., This work was supported by the European Union's Horizon 2020 Research and Innovation Program under the Marie Sklodowska-Curie Grant Agreement No. 766082 (MY-ATRIA Project) and under the Grant Agreement No. 101016496, by Direccion General de Politica Cientifica de la Generalitat Valenciana (PROMETEO/2020/043), by the National Science Foundation under Grants CMMI-1762553 and CMMI-2011280, and by the National Institutes of Health under Grant No. 1R01HL143450-01.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research software Software (Software)

Application of Machine Learning to improve the efficiency of electrophysiological simulations used for the prediction of drug-induced ventricular arrhythmia

  • Rodríguez-Belenguer, Pablo
  • Kopańska, Karolina
  • Llopis Lorente, Jordi
  • Pastor, Manuel
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
In cardiotoxicity studies it is common to pre-compute the values of different biomarkers (my equation or TX) for a range of ion channel blockades. Since every simulation requires costly computations, to complete the matrix of simulations for several ion channels can be cumbersome. Some examples of how these simulations are run and used are included in the references. The relationship between the input values and the biomarker is not too complex and Machine Learning can be used to obtain a good approximation. The resulting function can be generated using only an small fraction of the computations required to generate the whole matrix. This function can then be used to predict the biomarker value for any combination of the covered range, with an excellent accuracy In this repository we have included a jupyter notebook and some simulation results that demonstrate this idea. Regarding the data matrices, they correspond to simulations using a modified version of the ventricular action potential model by O'Hara et al., which have been performed by Jordi Llopis, Beatriz Trenor and Javier Saiz at the Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, Valencia, Spain KrKsCaL.xlsx: This is the data matrix needed to build the ML models. APD90_12CiPA_drugs_IKrIKsICaL.xlsx: This excel file contains the input and output values for CiPA compounds. EFTPC_IC50_28_CiPADrugs.xlsx: This file contains D, my equation and hill coefficient to calculate the input values for CiPA compounds of the previous excel file. Folder "Matrix Building": This folder contains MATLAB functions for generating the KrKsCaL matrix. The script "buildMatrixKrKsNaL.m" is the main script which run the electrophysioloigcal simulations and generates the matrix References Llopis J, Cano J, Gomis-Tena J, Romero L, Sanz F, Pastor M, Trenor B, Saiz J. In silico assay for preclinical assessment of drug proarrhythmicity. J Pharmacol Toxicol Methods 2019 99: 106595. PMID: 31962986 DOI: 10.1016/j.vascn.2019.05.106. O’Hara, T., Virág, L., Varró, A. & Rudy, Y. Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental Validation. PLOS Comput. Biol. 7, e1002061 (2011). Licensing CardioML was produced at the PharmacoInformatics lab (http://phi.upf.edu), in the framework of the eTRANSAFE project (http://etransafe.eu). eTRANSAFE has received support from IMI2 Joint Undertaking under Grant Agreement No. 777365. This Joint Undertaking receives support from the European Union’s Horizon 2020 research and innovation programme and the European Federation of Pharmaceutical Industries and Associations (EFPIA). Copyright 2022 Manuel Pastor (manuel.pastor@upf.edu) CardioML is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation version 3. CardioML is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with CardioML source code. If not, see http://www.gnu.org/licenses/.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research software Software (Software)

Considering Population Variability of Electrophysiological Models Improves the In Silico Assessment of Drug-Induced Torsadogenic Risk

  • Llopis Lorente, Jordi
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
This repository contains the parameter sets of the population of TorORd models and the the population of ORdmD models, the ORdmD CellML file and MALTAB code used in Llopis-Lorente, J., Trenor, B., Saiz, J. (2022). Considering Population Variability of Electrophysiological Models Improves the In Silico Assessment of Drug-Induced Torsadogenic Risk
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Combining pharmacokinetic and electrophysiological models for early prediction of drug-induced arrhythmogenicity

  • Llopis-Lorente, Jordi
  • Baroudi, Samuel
  • Koloskoff, Kévin
  • Basset, Matthieu
  • Benito, Sylvain
  • Dayan, Frederic
  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
[EN] Background and Objective: In silico methods are gaining attention for predicting drug-induced Torsade de Pointes (TdP) in different stages of drug development. However, many computational models tended not to account for inter-individual response variability due to demographic covariates, such as sex, or physiologic covariates, such as renal function, which may be crucial when predicting TdP. This study aims to compare the effects of drugs in male and female populations with normal and impaired renal function using in silico methods.Methods: Pharmacokinetic models considering sex and renal function as covariates were implemented from data published in pharmacokinetic studies. Drug effects were simulated using an electrophysiologically calibrated population of cellular models of 300 males and 300 females. The population of models was built by modifying the endocardial action potential model published by O'Hara et al. (2011) according to the experimentally measured gene expression levels of 12 ion channels.Results: Fifteen pharmacokinetic models for CiPA drugs were implemented and validated in this study. Eight pharmacokinetic models included the effect of renal function and four the effect of sex. The mean difference in action potential duration (APD) between male and female populations was 24.9 ms (p<0.05). Our simulations indicated that women with impaired renal function were particularly susceptible to drug-induced arrhythmias, whereas healthy men were less prone to TdP. Differences between patient groups were more pronounced for high TdP-risk drugs. The proposed in silico tool also revealed that individuals with impaired renal function, electro-physiologically simulated with hyperkalemia (extracellular potassium concentration [K+](o) = 7 mM) exhibited less pronounced APD prolongation than individuals with normal potassium levels. The pharmacokinetic/electrophysiological framework was used to determine the maximum safe dose of dofetilide in different patient groups. As a proof of concept, 3D simulations were also run for dofetilide obtaining QT prolongation in accor-dance with previously reported clinical values.Conclusions: This study presents a novel methodology that combines pharmacokinetic and electrophysiological models to incorporate the effects of sex and renal function into in silico drug simulations and highlights their impact on TdP-risk assessment. Furthermore, it may also help inform maximum dose regimens that ensure TdP-related safety in a specific sub-population of patients., This project received funding from the European Union's Horizon 2020 Research and Innovation Program under grant agreement No. 101016496 (SimCardioTest) . This work was also partially supported by the Direccion General de Politica Cientifica de la Generalitat Valenciana (PROMETEO/2020/043) . The authors also thankfully acknowledge the computer resources at MareNostrum and the technical support provided by Barcelona Supercomputing Center (IM-2021-1-0001, IM-2021-1-0003, IM-2022-1-0002, IM-2023-1-0002) . JL is being funded by the Ministerio de Ciencia, Innovacion y Universidades for the Formacion de Profesorado Universitario (grant reference: FPU18/01659) . Funding for open access charge: Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Combining pharmacokinetic and electrophysiological models for early prediction of drug-induced arrhythmogenicity

  • Llopis-Lorente, Jordi
  • Baroudi, Samuel
  • Koloskoff, Kévin
  • Basset, Matthieu
  • Benito, Sylvain
  • Dayan, Frederic
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
This repository contains the code used to generate the male and female population of models and simulate the different pharmacokinetic scenarios in Llopis-Lorente et al. (2023). Combining pharmacokinetic and electrophysiological models for early prediction of drug-induced arrhythmogenicity
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Uncertainty assessment of proarrhythmia predictions derived from multi-level in silico models

  • Kopanska, Karolina
  • Rodriguez-Belenguer, Pablo
  • Llopis-Lorente, Jordi
  • Pastor, Manuel
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] In silico methods can be used for an early assessment of arrhythmogenic properties of drug candidates. However, their use for decision-making is conditioned by the possibility to estimate the predictions' uncertainty. This work describes our efforts to develop uncertainty quantification methods for the predictions produced by multi-level proarrhythmia models. In silico models used in this field usually start with experimental or predicted IC50 values that describe drug-induced ion channel blockade. Using such inputs, an electrophysiological model computes how the ion channel inhibition, exerted by a drug in a certain concentration, translates to an altered shape and duration of the action potential in cardiac cells, which can be represented as arrhythmogenic risk biomarkers such as the APD(90). Using this framework, we identify the main sources of aleatory and epistemic uncertainties and propose a method based on probabilistic simulations that replaces single-point estimates predicted using multiple input values, including the IC(50)s and the electrophysiological parameters, by distributions of values. Two selected variability types associated with these inputs are then propagated through the multi-level model to estimate their impact on the uncertainty levels in the output, expressed by means of intervals. The proposed approach yields single predictions of arrhythmogenic risk biomarkers together with value intervals, providing a more comprehensive and realistic description of drug effects on a human population. The methodology was tested by predicting arrhythmogenic biomarkers on a series of twelve well-characterised marketed drugs, belonging to different arrhythmogenic risk classes., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. The authors received funding from the eTRANSAFE project, Innovative Medicines Initiative 2 Joint Undertaking under Grant Agreement No. 777365, supported from European Union s Horizon 2020 and the EFPIA. Authors declare that this work refects only the author s view, and that IMI-JU is not responsible for any use that may be made of the information it contains. Also, this project received funding from the European Union s Horizon 2020 Research and Innovation programme under Grant Agreement No. 964537 (RISK-HUNT3R), which is part of the ASPIS cluster. We also received funding from the SimCardioTest supported by European Union s Horizon 2020 research and innovation programme under Grant Agreement No. 101016496. J.L.L. is being funded by the Ministerio de Ciencia, Innovacion y Universidades for the Formacion de Profesorado Universitario (Grant Reference: FPU18/01659). The work was also partially support by the Dirección General de Política Científca de la Generalitat Valenciana (PROMETEO/2020/043).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of Machine Learning to improve the efficiency of electrophysiological simulations used for the prediction of drug-induced ventricular arrhythmia

  • Rodriguez-Belenguer, Pablo
  • Kopanska, Karolina
  • Llopis-Lorente, Jordi
  • Pastor, Manuel
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Background and Objective In silico prediction of drug-induced ventricular arrhythmia often requires computationally intensive simulations, making its application tedious and non-interactive. This inconvenience can be mitigated using matrices of precomputed simulation results, allowing instantaneous computation of biomarkers such as action potential duration at 90% of the repolarisation (APD90). However, preparing such matrices can be computationally intensive for the method developers, limiting the range of simulated conditions. In this work, we aim to optimise the generation of these matrices so that they can be obtained with less effort and for a broader range of input values. Methods Machine learning methods were applied, building models trained with only a small fraction of the originally simulated results. The predictive performances of the models were assessed by comparing their predicted values with the actual simulation results, using percentual mean absolute error and mean relative error, as well as the percentage of data with a relative error below 5%. Results Our method obtained highly accurate estimations of the original values, leading to a nearly one hundred-fold decrease in computation time. This method also allows precomputing more complex matrices, describing the effect of more ion channels on the APD90. The best results were obtained by applying Support Vector Machine models, which yielded errors below 1% in most cases. This approach was further validated by predicting the APD90 of a set of 12 CiPA compounds and exporting the optimal settings for predicting APD90 using a different set of ion channels, always with satisfactory results. Conclusions The proposed method effectively reduces the computational effort required to generate matrices of precomputed electrophysiological simulation values. The same approach can be applied in other fields where computationally costly simulations are applied repeatedly using slightly different input values., The authors received funding from the eTRANSAFE project, Innovative Medicines Initiative 2 Joint Undertaking under grant agreement No 777365, supported from European Union's Horizon 2020 and the EFPIA. We also received funding from the SimCardioTest supported by European Union¿s Horizon 2020 research and innovation programme under grant agreement No 101016496. J.L.L. is being funded by the Ministerio de Ciencia, Innovacion y Universidades for the Formacion de Profesorado Universitario (Grant Reference: FPU18/01659). The work was also partially support by the Dirección General de Política Científica de la Generalitat Valenciana (PROMETEO/ 2020/043).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimentally validated modeling of dynamic drug-hERG channel interactions reproducing the binding mechanisms and its importance in action potential duration

  • Escobar-Ropero, Fernando|||0000-0001-7602-447X
  • Gomis-Tena Dolz, Julio|||0000-0002-1309-2368
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Friis, Soren
  • Adly, Nouran
  • Brinkwirth, Nina
  • Klaerke, Dan A.
  • Stoelzle-Feix, Sonja
[EN] Background and Objective: Assessment of drug cardiotoxicity is critical in the development of new compounds and modeling of drug-binding dynamics to hERG can improve early cardiotoxicity assessment. We previously developed a methodology to generate Markovian models reproducing preferential state-dependent binding properties, trapping dynamics and the onset of IKr block using simple voltage clamp protocols. Here, we test this methodology with real IKr blockers and investigate the impact of drug dynamics on action potential prolongation. Methods: Experiments were performed on HEK cells stably transfected with hERG and using the Nanion SyncroPatch 384i. Three protocols, P-80, P0 and P40, were applied to obtain the experimental data from the drugs and the Markovian models were generated using our pipeline. The corresponding static models were also generated and a modified version of the O¿Hara-Rudy action potential model was used to simulate the action potential duration. Results: The experimental Hill plots and the onset of IKr block of ten compounds were obtained using our voltage clamp protocols and the models generated successfully mimicked these experimental data, unlike the CiPA dynamic models. Marked differences in APD prolongation were observed when drug effects were simulated using the dynamic models and the static models. Conclusions: These new dynamic models of ten well-known IKr blockers constitute a validation of our methodology to model dynamic drug¿hERG channel interactions and highlight the importance of state-dependent binding, trapping dynamics and the time-course of IKr block to assess drug effects even at the steady-state., This work was funded by the Spanish Ministerio de Ciencia, Innovacion y Universidades [grant "Formacion de Profesorado Universitario" FPU19/02200; grant PID2022-140553OB-C41 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU]; the European Union's Horizon 2020 research and innovation program [grant agreement No. 101016496 (SimCardioTest) ] and the Direccion General de Politica Cientifica de la Generalitat Valenciana [grant PROMETEO/2020/043]. SF, NA, NB and SS are employed by Nanion Technologies, the manufacturer of the SyncroPatch 384i used to obtain the experimental data of this manuscript. The dynamic models of the I Kr blockers have been generated in accordance with the technology protected by PCT/ES2023/070195 (patent pending).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of the response of human iPSC-derived cardiomyocyte tissue to I CaL block. A combined in vitro and in silico approach

  • Dasí, Albert
  • Hernández-Romero, Ismael
  • Gómez, Juan F.
  • Andreu M. Climent|||0000-0002-7260-8811
  • Ferrero De Loma-Osorio, José María|||0000-0003-4200-9225
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
[EN] The high incidence of cardiac arrythmias underlines the need for the assessment of pharmacological therapies. In this field of drug efficacy, as in the field of drug safety highlighted by the Comprehensive in Vitro Proarrhythmia Assay initiative, new pillars for research have become crucial: firstly, the integration of in-silico experiments, and secondly the evaluation of fully integrated biological systems, such as human induced pluripotent stem cell derived cardiomyocytes (hiPSC-CMs). In this study, we therefore aimed to combine in-vitro experiments and in-silico simulations to evaluate the antiarrhythmic effect of L-type calcium current (I-CaL) block in hiPSC-CMs. For this, hiPSC-CM preparations were cultured and an equivalent virtual tissue was modeled. Re-entry patterns of electrical activation were induced and several biomarkers were obtained before and after I-CaL block. The virtual hiPSC-CM simulations were also reproduced using a tissue composed of adult ventricular cardiomyocytes (hAdultV-CMs). The analysis of phases, currents and safety factor for propagation showed an increased size of the re-entry core when I-CaL was blocked as a result of depressed cellular excitability. The bigger wavefront curvature yielded reductions of 12.2%, 6.9%, and 4.2% in the frequency of the re-entry for hiPSC-CM cultures, virtual hiPSC-CM, and hAdultV-CM tissues, respectively. Furthermore, I-CaL block led to a 47.8% shortening of the vulnerable window for re-entry in the virtual hiPSC-CM tissue and to re-entry vanishment in hAdultV-CM tissue. The consistent behavior between in-vitro and in-silico hiPSC-CMs and between in-silico hiPSC-CMs and hAdultV-CMs evidences that virtual hiPSC-CM tissues are suitable for assessing cardiac efficacy, as done in the present study through the analysis of I-CaL block., This work was supported by the "Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2017-2020" of the Ministerio de Ciencia e Innovacion y Universidades (PID2019-104356RB-C41/AEI/10.13039/501100011033) , also by the Direccion General de Politica Cientifica de la Generalitat Valenciana (PROMETEO 2020/043) , by the European Union's Horizon 2020 Research and Innovation Programme under Grant Agreement No. 101016496, and by the Agencia Estatal de Investigacion [RYC2018-024346-I].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A simulation study of the impact of drug-IKr binding mechanisms on biomarkers of proarrhythmic risk reveals a crucial role in reverse use-dependence of action potential duration and a marked influence on the vulnerable window

  • Gomis-Tena Dolz, Julio|||0000-0002-1309-2368
  • Escobar-Ropero, Fernando|||0000-0001-7602-447X
  • Romero Pérez, Lucia|||0000-0003-4605-8630
[EN] Background and objective In silico human models are being used more and more to predict the potential proarrhythmic risk of compounds. It has been shown that incorporation of the dynamics of drug-hERG channel interactions can have an important impact on the action potential duration (APD) at normal heart rates. Our aim is to investigate the relevance of drug dynamics on other important biomarkers of proarrhythmic risk. Methods We use the state-of-the-art mathematical models of the cardiac electrophysiological activity to simulate TRIaD biomarkers, namely Triangulation, Reverse use-dependency, electrical Instability of the action potential and Dispersion, together with the vulnerable window to unidirectional block. They were simulated in control conditions and in the presence of an extensive set of 114 in silico IKr blockers with different kinetics and affinities to conformational states of the channel and 10 well-known real IKr blockers at the concentration leading to a 25 % prolongation of the APD. Results Our results show that drug binding dynamics to hERG are crucial for the reverse use-dependence of APD, the slope of the APD restitution curve as a function of the root square of the cycle length ranging from 0 to 5.6 ms/ms (2.1 ms/ms in control conditions). The vulnerable window for unidirectional block and the transmural action potential duration dispersion markedly depended on the drug binding mechanisms and kinetics, although to a lesser extent. Virtual drugs led to increments of these two biomarkers from 25 % to 200 %. On the contrary, temporal instability and, beat-to-beat instability, are less dependent on the dynamics of drug binding. The results obtained with the models of real IKr blockers are in line with those obtained with the virtual drugs. Conclusions Our study highlights the importance of considering the drug binding mechanism, as well as the kinetics, to assess the effects of IKr blockers. Moreover, adoption of in silico models mimicking these characteristics would contribute to the improvement of the prediction of the proarrhythmic risk of new compounds., This work was funded by the Spanish Ministerio de Ciencia, Innovacion y Universidades [grant "Formacion de Profesorado Universitario" FPU19/02200; grant PID2022-140553OB-C41 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU] ; the European Union's Horizon 2020 research and innovation program [grant agreement No 101016496 (SimCardioTest) ] ; and the Agencia Valenciana de la Innovacio and by ERDF/EU (INNVA1/2024/60) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

In silico predictions of action potential propagation in doxorubicin cardiotoxicity: A parametric study using preclinical 3D magnetic resonance imaging-based fibrotic left ventricle models

  • Villar-Valero, Javier|||0009-0003-1889-0515
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Rodríguez Padilla, Jairo
  • Cedilnik, Nicolas
  • Ly, Buntheng
  • Gomez, Juan F.
  • Sermesant, Maxime
  • Pop, Mihaela
[EN] Doxorubicin (DOX) is a widely used chemotherapeutic agent, but its cardiotoxic effects, including diffuse myocardial fibrosis, increase the risk of dangerous arrhythmias. There is a critical need for non-invasive tools to predict DOX-related ventricular arrhythmias in early chronic stages following chemotherapy. A computational study was performed using experimental data from three pigs: one control and two at 9 weeks following DOX. Customized 3D left ventricular (LV) models were generated from late gadolinium-enhanced magnetic resonance imaging and electro-anatomical maps, integrating tissue structure, electrical properties (healthy/fibrosis) and fibre directions. Action potential (AP) wave propagation was simulated using a high-performance numerical solver. A virtual programmed stimulation protocol was applied in 96 simulations to assess arrhythmia inducibility, varying the parameters corresponding to excitability and conduction velocity in fibrotic zones. Arrhythmias were inducible only in DOX-treated cases. Reentrant wave genesis depended on: excitability, conduction velocity, fibrosis distribution and AP duration heterogeneity. In one scenario, AP heterogeneities and a ¿70% reduction in diffusion coefficient were required to induce reentry despite unchanged excitability in fibrosis. This study presents the first computational simulation of DOX-induced cardiotoxicity in a realistic 3D LV model using a highly efficient, automated Lattice¿Boltzmann approach. Our findings provide insights into arrhythmogenic mechanisms and may aid in developing strategies to prevent and treat DOX-related cardiotoxicity., European Comission Horizon 2020: Beatriz Trenor, 101016496; French Government: Maxime Sermesant, ANR-19-P3IA-0002; Canadian CIHR: Mihaela Pop, (PJT) 153212; Spanish Government: Javier VillarValero, MCIN/AEI/10.13039/501100011033; Spanish Government: Juan F Gomez, PID2022-136273OA-C33; Spanish Government: Beatriz Trenor, PID2022-140553OB-C41; Barcelona Supercomputing Center (BSC): Beatriz Trenor, IM-2021-1-0001 and IM-2021-3-0001.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Insights from an electro-mechanical heart failure cell model: Role of SERCA enhancement on arrhythmogenesis and myocyte contraction

  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Zaza, Antonio
[EN] Background and objective: Structural and electrical remodeling in heart failure predisposes the heart to ventricular arrhythmias. Computer modeling approaches, used to complement experimental results, can provide a more mechanistic knowledge of the biophysical phenomena underlying cardiac pathologies. Indeed, previous in-silico studies have improved the understanding of the electrical correlates of heart failure involved in arrhythmogenesis; however, information on the crosstalk between electrical activity, intracellular Ca2+ and contraction is still incomplete. This study aims to investigate the electro-mechanical behavior of virtual failing human ventricular myocytes to help in the development of therapies, which should ideally target pump failure and arrhythmias at the same time. Methods: We implemented characteristic remodeling of heart failure with reduced ejection fraction by including reported changes in ionic conductances, sarcomere function and cell structure (e.g. T-tubules disarray). Model parametrization was based on published experimental data and the outcome of simulations was validated against experimentally observed patterns. We focused on two aspects of myocardial dysfunction central in heart failure: altered force-frequency relationship and susceptibility to arrhythmogenic early afterdepolarizations. Because biological variability is a major problem in the generalization of in-silico findings based on a unique set of model parameters, we generated and evaluated a population of models. Results: The population-based approach is crucial in robust identification of parameters at the core of abnormalities and in generalizing the outcome of their correction. As compared to non-failing ones, failing myocytes had prolonged repolarization, a higher incidence of early afterdepolarizations, reduced contraction and a shallower force-frequency relationship, all features peculiar of heart failure. Component analysis applied to the model population identified reduced SERCA function as a relevant contributor to most of these derangements, which were largely reverted or diminished by restoration of SERCA function alone. Conclusions: These simulated results encourage the development of strategies comprising SERCA stimulation and highlight the need to evaluate both electrical and mechanical outcomes., This work received funding for open access charge: CRUE Universitat Politècnica de València. The project was supported by the European Union's Horizon 2020 research and innovation programme under grant agreement No 101016496 (SimCardioTest), and by Grant PID2019-104356RB-C41 funded by MCIN/AEI/10.13039/501100011033.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Insights from electromechanical simulations to assess omecamtiv mecarbil efficacy in heart failure

  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • van Herck, Ilse
  • Daversin-Catty, Cécile
  • Finsberg, Henrik
  • Llopis-Lorente, Jordi
  • Arevalo, Hermenegild
  • Wall, Samuel
[EN] Heart failure is a cardiac pathology characterized by causing myocardial dysfunction. The need to improve current pharmacotherapy for patients with heart failure has encouraged the development of more promising compounds. Currently, the amount of experimentation required during the early phases of drug development to assess safety and efficacy is costly, but computer simulations can help accelerate the process. In the present study, we performed computer simulations to investigate the electromechanical effects of the sarcomeric drug omecamtiv mecarbil on cardiac tissue. We used a cellular human electromechanical model to develop a concentration-dependent numerical model for the pharmacological compound based on previous experimental evidence. It was then implemented on a ventricular slab to extrapolate cellular activity to myocardial tissue scale, and heart failure with reduced ejection fraction conditions was reproduced. In silico results reveal that omecamtiv mecarbil can correct the depressed active force developed by failing myocytes and make the slab contract to the same extent as in healthy conditions. However, additional changes involving contraction times and diastolic function, measured as the time to active tension peak and baseline slab stretch, respectively, can compromise the pumping capacity of the heart. After exploring drug effects at different heart rates, results show that elevated stimulation frequencies (2 Hz), together with overdoses (omecamtiv mecarbil > 0.8 mu m), are the main factors reducing fractional shortening and leading to loss of function. We demonstrate that electromechanical simulation results can provide a better understanding of the mechanism of action of a drug and facilitate the redirection of future investigations.Key points A new pipeline to assess the efficacy of inotropic drugs based on computational electromechanical models is described. Omecamtiv mecarbil increases developed force in failing cardiac tissue. Undesirable effects on diastolic function and contraction duration override the positive effects. Fast heart rates and elevated omecamtiv mecarbil doses aggravate cardiac dysfunction., This work was partially funded by European Union's Horizon 2020 Framework Programme (SimCardioTest project, grant agreement 101 016 496), and by grant PID2022-140553OB-C41 funded by MICIU/AEI/10.13039/501 100 011 033 and by ERDF/EU. Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Building credibility of computational models in cardiovascular medicine through verification and validation

  • Setzu, Romano
  • Olivares, Andy
  • Mill, Jordi
  • Albors, Carlos
  • Cámara, Óscar
  • Valen-Sendstad, Kristian
  • Sermesant, Maxime
  • Barbier, Michèle
  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
[EN] Cardiovascular diseases affect 15 million people in Europe and digital solutions are now seen as very useful tools in the search for new drugs and medical devices. SimCardioTest is a 4-year project funded by the European Commission that aims to develop credible computer modelling and simulation approaches on a cloud-based platform for testing cardiac drugs and devices in silico., This project has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme under grant agreement No. 101078351.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

Uncertainty Assessment of Proarrhythmia Predictions Derived from Multi-Level in Silico Models

  • Kopanska, Karolina
  • Rodríguez-Belenguer, Pablo
  • Llopis-Lorente, Jordi
  • Pastor, Manuel
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] These datasets were generated to train ("PopulationDrugsTrainingKrNaLCaL.xlsx") and test ("PopulationDrugsTestKrCaLNaL.xlsx") the uncertainty assessment models developed in the paper "Uncertainty assessment of proarrhythmia predictions derived from multi-level in silico models" by Kopanska, Rodríguez-Belenguer, et al., The authors received funding from the eTRANSAFE project, Innovative Medicines Initiative 2 Joint Undertaking under grant agreement No 777365, supported from European Union's Horizon 2020 and the EFPIA. We also received funding from the SimCardioTest supported by European Union’s Horizon 2020 research and innovation programme under grant agreement No 101016496. J.L.L. is being funded by the Ministerio de Ciencia, Innovacion y Universidades for the “Formacion de Profesorado Universitario” (Grant Reference: FPU18/01659). The work was also partially support by the Dirección General de Política Científica de la Generalitat Valenciana (PROMETEO/ 2020/043).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Considering population variability of electrophysiological models improves the assessment of drug-induced torsadogenic risk

  • Llopis-Lorente, Jordi
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Background and Objective In silico tools are known to aid in drug cardiotoxicity assessment. However, computational models do not usually consider electrophysiological variability, which may be crucial when predicting rare adverse events such as drug-induced Torsade de Pointes (TdP). In addition, classification tools are usually binary and are not validated using an external data set. Here we analyze the role of incorporating electrophysiological variability in the prediction of drug-induced arrhythmogenic-risk, using a ternary classification and two external validation datasets. Methods The effects of the 12 training CiPA drugs were simulated at three different concentrations using a single baseline model and an electrophysiologically calibrated population of models. 9 biomarkers related with action potential (AP), calcium dynamics and net charge were measured for each simulated concentration. These biomarkers were used to build ternary classifiers based on Support Vector Machines (SVM) methodology. Classifiers were validated using two external drug sets: the 16 validation CiPA drugs and 81 drugs from CredibleMeds database. Results Population of models allowed to obtain different AP responses under the same pharmacological intervention and improve the prediction of drug-induced TdP with respect to the baseline model. The classification tools based on population of models achieve an accuracy higher than 0.8 and a mean classification error (MCE) lower than 0.3 for both validation drug sets and for the two electrophysiological action potential models studied (Tomek et al. 2020 and a modified version of O'Hara et al. 2011). In addition, simulations with population of models allowed the identification of individuals with lower conductances of IKr, IKs, and INaK and higher conductances of ICaL, INaL, and INCX, which are more prone to develop TdP. Conclusions The methodology presented here provides new opportunities to assess drug-induced TdP-risk, taking into account electrophysiological variability and may be helpful to improve current cardiac safety screening methods., This project has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement No 101016496 (SimCardioTest). This workwas alsopartially supported by the Direccion General de Politica Cientifica de la Generalitat Valenciana (PROMETEO/2020/043). JL is being funded by the Ministerio de Ciencia, Innovacion y Universidades for the Formacion de Profesorado Universitario (grant reference: FPU18/01659). Funding for open access charge: Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Integration of electrophysiological and mechanical biomarkers in cardiac risk assessment models

  • Priego-Saiz, Lucía
  • Llopis-Lorente, Jordi
  • Finsberg, Henrik
  • Daversin-Catty, Cécile
  • Van Herck, Ilsbeth
  • Wall, Samuel
  • Arevalo, Hermenegild
  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
[EN] Background and Objective: Cardiac drug safety assessment is essential to detect molecules with potential adverse effects, particularly those increasing the risk of arrhythmias such as Torsade de Pointes (TdP). The challenge lies in achieving early predictions with minimal experimental studies while maintaining high sensitivity and specificity. Traditional approaches rely primarily on electrophysiological (EP) biomarkers; however, mechanical effects of drugs on cardiac contractility remain underexplored. This study aims to integrate electrophysiological and mechanical biomarkers to improve cardiac risk assessment models. Methods: The present study investigated the integration of electrophysiological and mechanical biomarkers using a cellular and three-dimensional in silico population approach. We evaluated the effects on different EP and mechanical relevant biomarkers to assess both, the proarrhythmic and inotropic risks of 39 compounds, including CiPA compounds and calcium channel blockers (CCBs). Classification models were developed using EP biomarkers alone and in combination with mechanical biomarkers to evaluate their predictive capabilities. Results: Classification models based solely on EP biomarkers demonstrated robust prediction on CiPA torsadogenic risk. The inclusion of mechanical biomarkers did not enhance classification accuracy for TdP risk. However, mechanical metrics revealed significant contractile changes induced by CCBs and other negative inotropic compounds, such as mavacamten. Drugs induced a range of fractional shortening values, correlated with ejection fraction variations, highlighting clinically relevant contractile effects. Conclusions: EP-based assessments remain reliable for predicting torsadogenic risk, but mechanical biomarkers provide crucial insights into drug-induced cardiac contractile effects. Future studies should focus on increasing experimental data availability and incorporating more complex cardiac geometries to enhance translational applicability of in silico models in comprehensive drug safety evaluation., Cellular simulations were performed on resources provided by Rigel cluster from the Universitat Politecnica de Valencia. Tissue simulations were performed on resources provided by Sigma2-the National Infra-structure for High Performance Computing and Data Storage in Norway. This work was partially funded by European Union's Horizon 2020 Framework Programme (SimCardioTest project, grant agreement 101016496) , and by grant PID2022-140553OB-C41 funded by MICIU/AEI/10.13039/501100011033 and by ERDF/EU. Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Research data Set de datos (Dataset)

In Silico Systematic Evaluation of the Scar Effect in Conventional and New Cardiac Resynchronization Therapy Approaches

  • Ruiz Gálvez, Cristóbal Rubén
  • Gómez García, Juan Francisco
  • Osca Asensi, Joaquín
  • Izquierdo de Francisco, Maria Teresa
  • Mora-Fenoll, María Teresa|||0000-0002-8069-2486
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
[EN] This dataset contains simulation data to represent the 12 ECG leads for every scenario simulated in the study by Ruiz et al. (2024) entitled: In Silico Systematic Evaluation of the Scar Effect in Conventional and New Cardiac Resynchronization Therapy Approaches (SImulation data), The authors also thankfully acknowledge the computer resources at MareNostrum and the technical support provided by Barcelona Supercomputing Center (IM-2021-1-0001, IM-2021-1-0003, IM-2022-1-0002, IM-2023-1-0002).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automatic modeling of dynamic drug-hERG channel interactions using three voltage protocols and machine learning techniques: A simulation study

  • Escobar-Ropero, Fernando|||0000-0001-7602-447X
  • Gomis-Tena Dolz, Julio|||0000-0002-1309-2368
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • Romero Pérez, Lucia|||0000-0003-4605-8630
[EN] Background: Assessment of drug cardiac safety is critical in the development of new compounds and is commonly addressed by evaluating the half-maximal blocking concentration of the potassium human ether-à-go-go related gene (hERG) channels. However, recent works have evidenced that the modelling of drug-binding dynamics to hERG can help to improve early cardiac safety assessment. Our goal is to de- velop a methodology to automatically generate Markovian models of the drug-hERG channel interactions. Methods: The training and the test sets consisted of 20800 and 5200 virtual drugs, respectively, dis- tributed into 104 groups with different affinities and kinetics to the conformational states of the chan- nel. In our system, drugs may bind to any state (individually or simultaneously), with different degrees of preference for a conformational state and the change of the conformational state of the drug bound channels may be restricted or allowed. To model such a wide range of possibilities, 12 Markovian chains are considered. Our approach uses the response of the drugs to our three previously developed voltage clamp protocols, which enhance the differences in the probabilities of occupying a certain conformational state of the channel (open, closed and inactivated). The computing tool is comprised of a classifier and a parameter optimizer and uses linear interpolation, support vector machines and a simplex method for function minimization. Results: We propose a novel methodology that automatically generates dynamic drug models using Markov model formulations and that elucidates the states where the drug binds and unbinds and the preferential binding state using data obtained from simple voltage clamp protocols that captures the preferential state-dependent binding properties, the relative affinities, trapping and non-trapping dynam- ics and the onset of I Kr block. Overall, the tool correctly predicted the class of 92.04% of the drugs and the model provided by the tool accurately fitted the response of the target compound, the mean accu- racy being 97.53%. Moreover, generation of the dynamic model of an I Kr blocker from its response to our voltage clamp protocols usually takes less than an hour on a common desktop computer. Conclusion: Our methodology could be very useful to model and simulate dynamic drug¿hERG channel interactions. It would contribute to the improvement of the preclinical assessment of the proarrhythmic risk of drugs that inhibit I Kr and the efficacy of antiarrhythmic I Kr blockers., This work was the Spanish Ministerio de Ciencia, Innovacion y Universidades [grant "Formacion de Profesorado Universitario" FPU19/02200; grant PID2019-104356RB-C41 funded by MCIN/AEI/10.13039/50110 0 011033 ]; the European Union's Horizon 2020 research and innovation program [grant agreement No 101016496 (SimCardioTest)]; and the Direccion General de Politica Cientifica de la Generalitat Valenciana [grant PROMETEO/2020/043]. Patenting of the proposed system/software is under consideration
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Tesis doctoral (DoctoralThesis)

In Silico Study of Ventricular Arrhythmias in Structurally and Functionally Remodeled Myocardium

  • Villar-Valero, Javier|||0009-0003-1889-0515
[ES] Las arritmias ventriculares continúan siendo una de las principales causas de muerte súbita cardíaca en corazones estructuralmente remodelados. A pesar de los avances en imagen y electrofisiología, la estratificación clínica del riesgo y los criterios de éxito de los procedimientos siguen basándose en marcadores globales y en pruebas de inducibilidad dependientes del protocolo, que pueden no reflejar la complejidad real del sustrato arrítmico. Esta tesis aborda la arritmogénesis ventricular como un fenómeno dependiente del sustrato que emerge de la interacción entre la estructura miocárdica, la heterogeneidad espacial electrofisiológica y factores moduladores dinámicos. La hipótesis central plantea que la reentrada aparece cuando el remodelado anatómico genera vías permisivas de conducción lenta y el acoplamiento local entre activación y recuperación permite interacciones frente-cola de onda capaces de explotar dichas vías. El objetivo principal es desarrollar y aplicar modelos computacionales mecanísticamente fundamentados que permitan identificar los determinantes estructurales y funcionales de la vulnerabilidad arrítmica ventricular. Para ello, se construyeron modelos ventriculares específicos de paciente y sujeto a partir de resonancia magnética con realce tardío de gadolinio, incorporando representaciones detalladas de cicatriz y fibrosis. El comportamiento electrofisiológico se simuló mediante mallas volumétricas anatómicamente detalladas y una formulación monodominio acoplada a modelos celulares ventriculares biofísicamente detallados, permitiendo el análisis mecanístico de la activación y la repolarización en sustratos remodelados. Se incorporó la modulación autonómica para evaluar los efectos simpáticos mediados por el ganglio estrellado sobre la repolarización y la vulnerabilidad arrítmica. La propensión a la arritmia se cuantificó mediante protocolos de estimulación y mediante el Reentry Vulnerability Index (RVI). Asimismo, se mejoró la escalabilidad computacional mediante la implementación de un esquema acelerado en GPU basado en el método de lattice Boltzmann acoplado a un modelo simplificado y calibrable de potencial de acción. Los resultados demuestran que la organización espacial de la cicatriz y la fibrosis, en particular la presencia de corredores de conducción dentro de tejido heterogéneo, condiciona de forma decisiva el inicio y mantenimiento de reentradas sostenidas. Además, la modulación simpática puede modificar significativamente los gradientes de repolarización y los patrones de vulnerabilidad incluso sin cambios en la inducibilidad clásica, lo que respalda el RVI como marcador basado en el sustrato capaz de capturar susceptibilidad latente. En el remodelado difuso no isquémico, los patrones específicos de fibrosis y la dispersión electrofisiológica determinan la dinámica de la reentrada, subrayando la relevancia de la caracterización estructural personalizada. En conjunto, esta tesis propone una visión estructural-funcional integrada de la arritmogénesis ventricular, destacando que el riesgo arrítmico depende no solo del remodelado anatómico, sino también de factores electrofisiológicos dinámicos y moduladores. Mediante el avance de estrategias mecanísticas y computacionales específicas de paciente, este trabajo contribuye hacia una evaluación más fundamentada fisiológicamente de la vulnerabilidad arrítmica ventricular., This work was supported by Grant PRE2020-091849 [MCIN/AEI/10.13039/50 1100011033] and “ESF Investing in your future”; Grant PID2019-104356RB-C41 [MCIN/AEI/10.13039/501100011033]; PID2022-136273OA-C33 and PID2022- 140553OB-C41 [MICIU/AEI/10.13039/501100011033 and by ERDF/EU]; Barcelona Supercomputing Center [IM-2021-1-0001, IM-2021-3-0001, IM-2024- 1-0010 and IM-2024-2-0015]; Oracle Cloud credits and related resources by Oracle for Research; and Teknon projects European Comission Horizon 2020: Beatriz Trenor, 101016496; French Government: Maxime Sermesant, ANR-19-P3IA-0002; Canadian CIHR: Mihaela Pop, (PJT) 153212; Spanish Government: Javier VillarValero, MCIN/AEI/10.1303 9/501100011033; Spanish Government: Juan F Gomez, PID2022-136273OAC33; Spanish Government: Beatriz Trenor, PID2022-140553OB-C41; Barcelona Supercomputing Center (BSC): Beatriz Trenor, IM-2021-1-0001 and IM-2021-3-0001.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of vulnerability to reentry in acute myocardial ischemia using a realistic human heart model

  • Carpio, Edison F.
  • Gómez, Juan F.
  • Rodríguez-Matas, José F.
  • Trenor Gomis, Beatriz Ana|||0000-0001-9166-6112
  • Ferrero De Loma-Osorio, José María|||0000-0003-4200-9225
[EN] Electrophysiological alterations of the myocardium caused by acute ischemia constitute a pro-arrhythmic substrate for the generation of potentially lethal arrhythmias. Experimental evidence has shown that the main components of acute ischemia that induce these electrophysiological alterations are hyperkalemia, hypoxia (or anoxia in complete artery occlusion), and acidosis. However, the influence of each ischemic component on the likelihood of reentry is not completely established. Moreover, the role of the His-Purkinje system (HPS) in the initiation and maintenance of arrhythmias is not completely understood. In the present work, we investigate how the three components of ischemia affect the vulnerable window (VW) for reentry using computational simulations. In addition, we analyze the role of the HPS on arrhythmogenesis. A 3D biventricular/torso human model that includes a realistic geometry of the central and border ischemic zones with one of the most electrophysiologically detailed model of ischemia to date, as well as a realistic cardiac conduction system, were used to assess the VW for reentry. Four scenarios of ischemic severity corresponding to different minutes after coronary artery occlusion were simulated. Our results suggest that ischemic severity plays an important role in the generation of reentries. Indeed, this is the first 3D simulation study to show that ventricular arrhythmias could be generated under moderate ischemic conditions, but not in mild and severe ischemia. Moreover, our results show that anoxia is the ischemic component with the most significant effect on the width of the VW. Thus, a change in the level of anoxia from moderate to severe leads to a greater increment in the VW (40 ms), in comparison with the increment of 20 ms and 35 ms produced by the individual change in the level of hyperkalemia and acidosis, respectively. Finally, the HPS was a necessary element for the generation of approximately 17% of reentries obtained. The retrograde conduction from the myocardium to HPS in the ischemic region, conduction blocks in discrete sections of the HPS, and the degree of ischemia affecting Purkinje cells, are suggested as mechanisms that favor the generation of ventricular arrhythmias., This work was supported by the Secretaría de Educacion ¿ Superior, Ciencia, Tecnología e Innovacion ¿ (SENESCYT) of Ecuador CIBAE-023- 2014, by Grant PID2019-104356RB-C41 funded by MCIN/AEI/ 10.13039/501100011033, by the European Union¿s Horizon 2020 research and innovation programme under grant agreement No 101016496, by Direccion ¿ General de Política Científica de la Generalitat Valenciana (PROMETEO 2020/043), and by the ¿Programa Salvador de Madariaga 2018¿¿ of the Spanish Ministry of Science, Innovation and Universities (Grant Reference PRX18/00489).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Simulación de los efectos de fármacos antiarrítmicos en la electrofisiología auricular

  • Puche-García, Violeta|||0000-0002-3386-1478
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[ES] La terapia farmacológica es la primera línea contra la fibrilación auricular; aunque los mecanismos no se comprenden por completo. Nuestro objetivo es comparar datos experimentales a nivel unicelular de varios fármacos con la respuesta de tres modelos computacionales diferentes: Courtemanche (CRN), Grandi y Skibsbye (SKI) empleando un modelo de bloqueo de poro simple, así como una variante de modelo dinámico para los fármacos flecainida y vernakalant en CRN (+INa,Marvok). La mayoría de las simulaciones consiguen reproducir la dependencia del aumento del APD90 y la disminución de la dV/dtmax con la frecuencia y la concentración. Además, las respuestas de CRN, CRN+INa,Marvok y SKI reprodujeron de manera más adecuada las tendencias encontradas en los resultados experimentales. El análisis realizado contribuye a la mejora de la simulación de fármacos antiarrítmicos., Este trabajo ha sido financiado por el Programa Prometeo de la Generalitat Valenciana (2020/043) y por el programa de investigación e innovación Horizon 2020 de la Unión Europea bajo subvención No 101016496 (SimCardioTest).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Left atrial thrombus - Are all atria and appendages equal?

  • Cresti, Alberto
  • Camara, Oscar
Although the left atrial appendage (LAA) seems useless, it has several critical functions that are not fully known yet, such as the causes for being the main origin of cardioembolic stroke. Difficulties arise due to the extreme range of LAA morphologic variability, making the definition of normality challenging and hampering the stratification of thrombotic risk. Furthermore, obtaining quantitative metrics of its anatomy and function from patient data is not straightforward. A multimodality imaging approach, using advanced computational tools for their analysis, allows a complete characterization of the LAA to individualize medical decisions related to left atrial thrombosis patients., This work was supported by the Spanish Ministry of Economy and Competitiveness under the Retos Investigacion project (RTI2018-101193-B-I00) and by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Uncertainty assessment of proarrhythmia predictions derived from multi-level in silico models

  • Kopańska, Karolina
  • Rodríguez-Belenguer, Pablo
  • Llopis-Lorente, Jordi
  • Trenor, Beatriz
  • Saiz, Javier
  • Pastor Maeso, Manuel
In silico methods can be used for an early assessment of arrhythmogenic properties of drug candidates. However, their use for decision-making is conditioned by the possibility to estimate the predictions' uncertainty. This work describes our efforts to develop uncertainty quantification methods for the predictions produced by multi-level proarrhythmia models. In silico models used in this field usually start with experimental or predicted IC50 values that describe drug-induced ion channel blockade. Using such inputs, an electrophysiological model computes how the ion channel inhibition, exerted by a drug in a certain concentration, translates to an altered shape and duration of the action potential in cardiac cells, which can be represented as arrhythmogenic risk biomarkers such as the APD90. Using this framework, we identify the main sources of aleatory and epistemic uncertainties and propose a method based on probabilistic simulations that replaces single-point estimates predicted using multiple input values, including the IC50s and the electrophysiological parameters, by distributions of values. Two selected variability types associated with these inputs are then propagated through the multi-level model to estimate their impact on the uncertainty levels in the output, expressed by means of intervals. The proposed approach yields single predictions of arrhythmogenic risk biomarkers together with value intervals, providing a more comprehensive and realistic description of drug effects on a human population. The methodology was tested by predicting arrhythmogenic biomarkers on a series of twelve well-characterised marketed drugs, belonging to different arrhythmogenic risk classes., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. The authors received funding from the eTRANSAFE project, Innovative Medicines Initiative 2 Joint Undertaking under Grant Agreement No. 777365, supported from European Union’s Horizon 2020 and the EFPIA. Authors declare that this work reflects only the author’s view, and that IMI-JU is not responsible for any use that may be made of the information it contains. Also, this project received funding from the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 964537 (RISK-HUNT3R), which is part of the ASPIS cluster. We also received funding from the SimCardioTest supported by European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 101016496. J.L.L. is being funded by the Ministerio de Ciencia, Innovacion y Universidades for the “Formacion de Profesorado Universitario” (Grant Reference: FPU18/01659). The work was also partially support by the Dirección General de Política Científica de la Generalitat Valenciana (PROMETEO/2020/043).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi
  • Montoliu, Helena
  • Moustafa, Abdel-Hakim
  • Olivares, Andy L.
  • Albors, Carlos
  • Aguado, Ainhoa M.
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier
  • Arzamendi, Dabit
  • Cochet, Hubert
  • Camara, Oscar
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM 2015-0502), and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062). In addition, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

In silico estimation of thrombogenic risk after left atrial appendage excision: towards digital twins in atrial fibrillation

  • Albors, Carlos
  • Arrarte Terreros, Nerea
  • Saiz-Vivó, Marta
  • Zappala, Pietro
  • Terpstra, Marc M.
  • Olivares Miyares, Andy Luis
  • Planken, R. Nils
  • van Boven, WimJan P.
  • Driessen, Antoine H. G.
  • de Groot, Joris R.
  • Camara, Oscar
Background & aim: The left atrial appendage (LAA) is a highly variable, pouch-like structure in the left atrium prone to thrombus formation, especially in atrial fibrillation (AF) patients. In silico cardiac models can help characterize the LAA's complex morphology and hemodynamics, aiding in identifying pro-thrombotic areas. This study assessed atrial hemodynamics and thrombus formation risk after LAA excision and compared with optimal synthetic excisions and occluder placements in high thrombogenic-risk cases. Methods: We included 33 patients from the MARK-AF study who had persistent AF and underwent excision of the LAA. We quantified the morphological characteristics of the post-excision LAA remnant. With patient-specific atrial geometries and boundary conditions, in silico blood flow simulations were performed. For each patient, we quantified multiple in silico indices to characterize blood flow patterns and identify thrombogenic regions. We performed an in silico comparison of different LAA treatment approaches. Results: In our cohort, 25/33 (76 %) of patients had a post-excision, protruding LAA remnant (LAA depth >10 mm). In silico simulations indicated that patients with a protruding remnant more frequently showed unfavorable values for in silico indices associated with high thrombogenic risk at the excision site. However, a prominent LAA remnant was not the only factor associated with a high thrombogenic risk. An optimal excision or optimal occluder device placement reduced thrombus formation risk. Conclusion: The combination of LAA remnant morphology and hemodynamics contributed to thrombus formation risk. Advanced in silico simulations uniquely enabled the comparison of different therapies, until now only centered on device occluders, contributing to digital twins in AF., This work was supported by the Spanish Ministry of Science, Innovation and Universities GENERALITAAT (PID2022-143239OB-I00) grant, the European Horizon 2020 SimCardioTest (ID 101016496) project, the Horizon 2024 GEMINI (ID 101136438) project, the Distinguished Women Scientist Fund and the Amsterdam University Medical Centers Women in Science Fund.
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Sensitivity analysis of left atrial wall modeling approaches and inlet/outlet boundary conditions in fluid simulations to predict thrombus formation

  • Albors, Carlos
  • Mill, Jordi
  • Kjeldsberg, Henrik A
  • Viladés-Medel, David
  • Olivares Miyares, Andy Luis
  • Valen-Sendstad, Kristian
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., In-silico fluid simulations of the left atria (LA) in atrial fibrillation (AF) patients can help to describe and relate patient-specific morphologies and complex flow haemodynamics with the pathophysiological mechanisms behind thrombus formation. Even in AF patients, LA wall motion plays a non-negligible role in LA function and blood flow patterns. However, obtaining 4D LA wall dynamics from patient-specific data is not an easy task due to current image resolution limitations. Therefore, several approaches have been proposed in the literature to include left atrial wall motion in fluid simulations, being necessary to benchmark them in relation to their estimations on thrombogenic risk. In this work, we present results obtained with computational fluid dynamic simulations of LA geometries from a control and an AF patient with different left atrial wall motion approaches: 1) assuming rigid walls; 2) with a passive movement of the mitral valve annulus plane from a dynamic mesh approach based on springs (DM-SB); and 3) imposing LA wall deformation extracted from dynamic computed tomography (DM-dCT) images. Different strategies for the inlet/outlet boundary conditions were also tested. The DM-dCT approach was the one providing simulation results closer to velocity curves extracted from the reference echocardiographic data, whereas the rigid wall strategy over-estimated the risk of thrombus formation., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 101016496 (SimCardioTest).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Digital twin integrating clinical, morphological and hemodynamic data to identify stroke risk factors

  • Saiz-Vivó, Marta
  • Mill, Jordi
  • Iriart, Xavier
  • Cochet, Hubert
  • Piella Fenoy, Gemma
  • Sermesant, Maxime
  • Camara, Oscar
Stroke remains a leading global cause of mortality, with ischemic stroke as the most common subtype. Atrial fibrillation (AF) increases ischemic stroke risk due to thrombus formation in the left atrium (LA), particularly in the left atrial appendage (LAA). Traditional risk assessments, like the CHA2DS2-VASc score, focus on clinical factors but often overlook LA morphology and hemodynamics. Existing studies either use mechanistic models with limited cases or rely solely on clinical data, missing hemodynamic insights. This study integrates statistical and mechanistic models within a Digital Twin framework, using unsupervised Multiple Kernel Learning on 130 AF patients. Combining LA morphology, hemodynamics, and clinical data improved patient stratification, identifying three phenogroups. The highest-risk group exhibited larger atrial dimensions, complex LAA structures, and elevated B-type natriuretic peptide levels. This study underscores the potential of Digital Twin models in assessing thrombus risk, emphasizing the need for further research to refine stroke prediction models., This project has received funding from the European Union’s Horizon 2020 research and innovation program under the grant agreements No 101016496 (SimCardioTest) and No 101136438 (GEMINI), as well as by the Spanish Ministry of Science, Innovation and Universities under the GENERALITAAT grant, (PID2022-143239OB-I00). GP’s contribution was supported by the ICREA Academia program.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Deep learning framework for real-time estimation of in-silico thrombotic risk indices in the left atrial appendage

  • Morales Ferez, Xabier
  • Mill, Jordi
  • Juhl, Kristine Aavild
  • Acebes Pinilla, César
  • Iriart, Xavier
  • Legghe, Benoit
  • Cochet, Hubert
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Patient-specific computational fluid dynamics (CFD) simulations can provide invaluable insight into the interaction of left atrial appendage (LAA) morphology, hemodynamics, and the formation of thrombi in atrial fibrillation (AF) patients. Nonetheless, CFD solvers are notoriously time-consuming and computationally demanding, which has sparked an ever-growing body of literature aiming to develop surrogate models of fluid simulations based on neural networks. The present study aims at developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), an in-silico index linked to the risk of thrombosis, typically derived from CFD simulations, solely from the patient-specific LAA morphology. To this end, a set of popular DL approaches were evaluated, including fully connected networks (FCN), convolutional neural networks (CNN), and geometric deep learning. While the latter directly operated over non-Euclidean domains, the FCN and CNN approaches required previous registration or 2D mapping of the input LAA mesh. First, the superior performance of the graph-based DL model was demonstrated in a dataset consisting of 256 synthetic and real LAA, where CFD simulations with simplified boundary conditions were run. Subsequently, the adaptability of the geometric DL model was further proven in a more realistic dataset of 114 cases, which included the complete patient-specific LA and CFD simulations with more complex boundary conditions. The resulting DL framework successfully predicted the overall distribution of the ECAP in both datasets, based solely on anatomical features, while reducing computational times by orders of magnitude compared to conventional CFD solvers., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme—FI (2020-FI-B-00690) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of the influence of pulmonary vein configuration on left atrial haemodynamics and thrombus formation in a large cohort

  • Mill, Jordi
  • Harrison, Josquin
  • Legghe, Benoit
  • Olivares, Andy L.
  • Morales, Xabier
  • Noailly, Jérôme
  • Iriart, Xavier
  • Cochet, Hubert
  • Sermesant, Maxime
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Moreover, the impact of structures such as the pulmonary veins (PVs) on LA haemodynamics has not been thoroughly studied due to the difficulties of acquiring appropriate data. On the other hand, in-silico studies and flow simulations allow a thorough analysis of haemodynamics, analysing the 4D nature of blood flow patterns under different boundary conditions. However, the reduced number of cases reported on the literature of these studies has been a limitation. The main goal of this work was to study the influence of PVs on left atrium (LA) and LAA haemodynamics. Computational fluid dynamics simulations were run on 52 patients, the largest cohort so far in the literature, where different parameters were individually studied: pulmonary veins orientation and configuration; LAA and LA volumes and its ratio; and flow velocities. Our computational analysis showed how the right pulmonary vein height and angulation have a great influence on LA haemodynamics. Additionally, we found that LAA with great bending with its tip pointing towards the mitral valve could contribute to favour flow stagnation., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496) and the European project PARIS (ID35).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

The role of the pulmonary veins on left atrial flow patterns and thrombus formation

  • Mill, Jordi
  • Harrison, Josquin
  • Saiz-Vivó, Marta
  • Albors, Carlos
  • Morales, Xabier
  • Olivares, Andy L.
  • Iriart, Xavier
  • Cochet, Hubert
  • Noailly, Jérôme
  • Sermesant, Maxime
  • Camara, Oscar
Atrial fibrillation (AF) is the most common human arrhythmia, forming thrombi mostly in the left atrial appendage (LAA). However, the relation between LAA morphology, blood patterns and clot formation is not yet fully understood. Furthermore, the impact of anatomical structures like the pulmonary veins (PVs) have not been thoroughly studied due to data acquisition difficulties. In-silico studies with flow simulations provide a detailed analysis of blood flow patterns under different boundary conditions, but a limited number of cases have been reported in the literature. To address these gaps, we investigated the influence of PVs on LA blood flow patterns and thrombus formation risk through computational fluid dynamics simulations conducted on a sizeable cohort of 130 patients, establishing the largest cohort of patient-specific LA fluid simulations reported to date. The investigation encompassed an in-depth analysis of several parameters, including pulmonary vein orientation (e.g., angles) and configuration (e.g., number), LAA and LA volumes as well as their ratio, flow, and mass-less particles. Our findings highlight the total number of particles within the LAA as a key parameter for distinguishing between the thrombus and non-thrombus groups. Moreover, the angles between the different PVs play an important role to determine the flow going inside the LAA and consequently the risk of thrombus formation. The alignment between the LAA and the main direction of the left superior pulmonary vein, or the position of the right pulmonary vein when it exhibits greater inclination, had an impact to distinguish the control group vs. the thrombus group. These insights shed light on the intricate relationship between PV configuration, LAA morphology, and thrombus formation, underscoring the importance of comprehensive blood flow pattern analyses., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00) and GENERALITAAT (PID2022-143239OB-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of device-related thrombosis for different left atrial appendage occluder settings

  • Planas, Eric
  • Mill, Jordi
  • Olivares, Andy L.
  • Morales, Xabier
  • Pons Vidal, Maria Isabel
  • Iriart, Xavier
  • Cochet, Hubert
  • Camara, Oscar
Comunicació presentada a: 12th International Workshop, STACOM 2021 celebrada del 27 de setembre de 2021 a Strasbourg, França., Atrial fibrillation (AF) is one of the most common cardiac arrhythmias and is associated to an increasing risk of stroke. Most AF- related strokes are formed in the left atrial appendage (LAA). To prevent thrombus formation, LAA occlusion (LAAO) is considered a suitable alternative for AF patients with contraindications for anti-coagulation treatment. Nevertheless, LAAO is linked to a non-negligible risk of gener- ating thrombus at the surface near the device (i.e., device-related throm- bus, DRT), depending on the implantation settings. For instance, it has been shown that not covering the pulmonary ridge (PR) with the LAAO increases the risk of DRT. In-silico analysis is a useful tool to better understand the blood flow patterns after LAAO and predict the risk of DRT for a given patient and device configuration. In the present work we designed a modelling pipeline based on fluid simulations, including a thrombus model using discrete phase modelling, to analyse the risk of DRT in six patient-specific geometries for different LAAO settings. In particular, we studied the possible incidence of DRT depending on the device positioning (covering/uncovering the PR) and type (Amplatzer Amulet and Watchman FLX). The resulting in-silico indices demon- strated that covering the PR entails less thrombogenic patterns than uncovering it. In our study, disk-based devices had better adaptability to complex LAA morphologies and a slightly minor associated risk of DRT than non-disk devices., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Inves- tigaci ́on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Cardiomyopathy and thrombogenesis in cats through left atrial morphological and fluid dynamics analysis

  • Pons Vidal, Maria Isabel
  • Olivares, Andy L.
  • Mill, Jordi
  • Novo Matos, Jose
  • García Cañadilla, Patricia, 1985-
  • Cerrada, Inma
  • Guy, Anna
  • Morales Ferez, Xabier
  • Hutchinson, John Ciaran
  • Simcock, Ian C.
  • Arthurs, Owen J.
  • Cook, Andrew C.
  • Luis Fuentes, Virginia
  • Camara, Oscar
The relationship between atrial fibrillation (AF), blood flow disturbances and thrombus formation is well-established in humans. Thrombi primarily form in the left atrial appendage (LAA), but the specific role of LAA morphology remains unclear. Felines, despite rarely experiencing AF, present a valuable model for studying human heart diseases. Cats exhibit a high incidence of cardiomyopathies, often accompanied by significant left atrial dilation and thrombus formation. This unique aspect prompts research focusing on LAA morphology and function in relation to thrombus development. Our study, using advanced image processing and fluid simulations on 24 cat hearts ranging from normal to cardiomyopathy subjects, aims to find distinctions in left atrium (LA) and LAA morphologies, blood flow patterns and their relation to thrombus formation. Significantly different variables in feline heart groups included: heart weight, LAA volume, LA volume, ostium area, ostium area-to-heart weight ratio, centreline length and velocity at the LAA ostium. Fluid simulations revealed lower LAA blood flow velocities and increased thrombotic risk in cases with thrombi. Our study enhances the understanding of LAA structure and function, offering insights into thrombus formation mechanisms with potential implications for better managing thrombosis risk in patients., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación projects VIROLAAI and GENERALITAAT (RTI2018-101193-B-I00, PID2022-143239OB-I00). Furthermore, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; Grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Automated 4D flow MRI pipeline for the quantification of advanced hemodynamic parameters in the left atrium

  • Morales, Xabier
  • Elsayed, Ayah
  • Zhao, Debbie
  • Loncaric, Filip
  • Aguado, Ainhoa M.
  • Masias Bruns, Mireia
  • Quill, Gina M.
  • Ramos, Marc
  • Doltra, Adelina
  • Garcia-Alvarez, Ana
  • Sitges, Marta
  • Marlevi, David
  • Young, Alistair A.
  • Nash, Martyn P.
  • Bijnens, Bart
  • Camara, Oscar
The left atrium (LA) plays a pivotal role in modulating left ventricular filling, yet its hemodynamics remain poorly understood due to the limitations of conventional ultrasound analysis. Four-dimensional flow magnetic resonance imaging (4D Flow MRI) holds promise for enhancing our understanding of atrial hemodynamics, but its analysis is hindered by the inherently low velocities within the chamber and the modest spatial resolution of 4D Flow MRI. Heterogeneity in acquisition protocols and MRI vendors, and the lack of standardized computational frameworks further complicates the creation of large, comparable datasets needed to assess the prognostic value of hemodynamic markers provided by 4D Flow MRI. To address these challenges, we introduce a computational framework tailored to the analysis of 4D Flow MRI in the LA, enabling the qualitative and quantitative analysis of advanced hemodynamic parameters (e.g., kinetic energy, vorticity, and pressure). We applied this framework to a diverse cohort spanning different degrees of left ventricular diastolic dysfunction to investigate the prognostic potential of these metrics. Our framework proved robustness across multicenter data of varying quality, producing high-accuracy automated segmentations. Notably, our findings show that 4D Flow MRI-derived parameters provide superior differentiation between healthy and pathological states than those available to conventional hemodynamic analysis tools., This study was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme - FI (2020 FI_B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (PID2022-143239OB-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital Transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496). This research was also supported by grants from NVIDIA and utilized NVIDIA RTX A6000. Data collection and analysis at the University of Auckland is supported by the Health Research Council of New Zealand (program grant 17/608). Funded also by Instituto de Salud Carlos III, Gobierno de España grant FIS PI21/00905 and Hospital Clinic, Premi Emili Letang-Josep Font (MR). D.M. acknowledges funding from the European Union (ERC, MultiPRESS, 101075494). Views and opinions expressed are those of the authors and do not reflect those of the European Union or the European Research Council Executive Agency.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Sensitivity analysis of in silico fluid simulations to predict thrombus formation after left atrial appendage occlusion

  • Mill, Jordi
  • Agudelo, Victor
  • Olivares Miyares, Andy Luis
  • Pons Vidal, Maria Isabel
  • Silva, Etelvino
  • Nuñez-Garcia, Marta
  • Morales Ferez, Xabier
  • Arzamendi, Dabit
  • Freixa, Xavier
  • Noailly, Jérôme
  • Camara, Oscar
Atrial fibrillation (AF) is nowadays the most common human arrhythmia and it is considered a marker of an increased risk of embolic stroke. It is known that 99% of AF-related thrombi are generated in the left atrial appendage (LAA), an anatomical structure located within the left atrium (LA). Left atrial appendage occlusion (LAAO) has become a good alternative for nonvalvular AF patients with contraindications to anticoagulants. However, there is a non-negligible number of device-related thrombus (DRT) events, created next to the device surface. In silico fluid simulations can be a powerful tool to better understand the relation between LA anatomy, haemodynamics, and the process of thrombus formation. Despite the increasing literature in LA fluid modelling, a consensus has not been reached yet in the community on the optimal modelling choices and boundary conditions for generating realistic simulations. In this line, we have performed a sensitivity analysis of several boundary conditions scenarios, varying inlet/outlet and LA wall movement configurations, using patient-specific imaging data of six LAAO patients (three of them with DRT at follow-up). Mesh and cardiac cycle convergence were also analysed. The boundary conditions scenario that better predicted DRT cases had echocardiography-based velocities at the mitral valve outlet, a generic pressure wave from an AF patient at the pulmonary vein inlets, and a dynamic mesh approach for LA wall deformation, emphasizing the need for patient-specific data for realistic simulations. The obtained promising results need to be further validated with larger cohorts, ideally with ground truth data, but they already offer unique insights on thrombogenic risk in the left atria., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Impact of blood rheological strategies on the optimization of patient-specific LAAO configurations for thrombus assessment

  • Albors, Carlos
  • Olivares Miyares, Andy Luis
  • Iriart, Xavier
  • Cochet, Hubert
  • Mill, Jordi
  • Camara, Oscar
Comunicació presentada a 12th International Conference, Functional Imaging and Modeling of the Heart, FIMH 2023, celebrada del 19 al 22 de juny de 2023 a Lió, França., Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4–6% incidence of device-related thrombus (DRT). In-silico simulations can be used to estimate the risk of DRT and identify the critical parameters, such as suboptimal device positioning. However, simulation outcomes depend a lot on a series of modelling assumptions such as blood behaviour. Therefore, in this work, we present fluid simulations results computed on two patient-specific LA geometries, using two different commercially available LAAO devices, located in two positions: 1) mimicking the real post-LAAO intervention configuration; and 2) an improved one better covering the pulmonary ridge for DRT prevention. Different blood modeling strategies were also tested. The results show flow re-circulations at low velocities with significant platelet accumulation in LAA-deep device positioning uncovering the pulmonary ridge, potentially leading to thrombus formation. In addition, assuming Newtonian blood behaviour may result in an overestimation of DRT risk., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement, No 101016496 (SimCardioTest).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Towards real-time optimization of left atrial appendage occlusion device placement through physics-informed neural networks

  • Morales, Xabier
  • Albors, Carlos
  • Mill, Jordi
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., The adoption of patient-specific computational fluid dynamics (CFD) simulations has been instrumental toward a better understanding of the mechanisms underlying thrombogenesis in the left atrial appendage. Such simulations can help optimize the placement of left atrial appendage occlusion (LAAO) devices in atrial fibrillation patients and avoid the generation of device-related thrombosis. However, integrating conventional solvers into clinical practice is cumbersome, as even the slightest change in model geometry involves computing the entire simulation from scratch. In contrast, neural networks can entirely circumvent this issue by transferring knowledge across models targeted at similar physical domains. Thus, in the present study, we introduced a neural network capable of predicting left atrial hemodynamics under different occlusion device configurations, relying solely on a single finite element simulation for training. To this end, we leveraged physics-informed neural networks (PINN), which embed the physical laws governing the domain of interest into the model, exhibiting far superior generalization capabilities than conventional data-driven models. Several device types and positions have been tested in two distinct left atrial geometries. By employing a single reference simulation per patient the network can predict the updated hemodynamics for a variety of device types and positions, orders of magnitude faster than with conventional CFD solvers., This work was funded by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme - FI (2020 FI_B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and the Retos Investigación project (RTI2018-101193-B-I00), and the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496). Additionally, this research was supported by grants from NVIDIA and utilized NVIDIA RTX A6000.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Impact of left atrial wall motion assumptions in fluid simulations on proposed predictors of thrombus formation

  • Kjeldsberg, Henrik A.
  • Albors, Carlos
  • Mill, Jordi
  • Viladés-Medel, David
  • Camara, Oscar
  • Sundnes, Joakim
  • Valen-Sendstad, Kristian
Atrial fibrillation (AF) poses a significant risk of stroke due to thrombus formation, which primarily occurs in the left atrial appendage (LAA). Medical image-based computational fluid dynamics (CFD) simulations can provide valuable insight into patient-specific hemodynamics and could potentially enhance personalized assessment of thrombus risk. However, the importance of accurately representing the left atrial (LA) wall dynamics has not been fully resolved. In this study, we compared four modeling scenarios; rigid walls, a generic wall motion based on a reference motion, a semi-generic wall motion based on patient-specific motion, and patient-specific wall motion based on medical images. We considered a LA geometry acquired from 4D computed tomography during AF, systematically performed convergence tests to assess the numerical accuracy of our solution strategy, and quantified the differences between the four approaches. The results revealed that wall motion had no discernible impact on LA cavity hemodynamics, nor on the markers that indicate thrombus formation. However, the flow patterns within the LAA deviated significantly in the rigid model, indicating that the assumption of rigid walls may lead to errors in the estimated risk factors. In contrast, the generic, semi-generic, and patient-specific cases were qualitatively similar. The results highlight the crucial role of wall motion on hemodynamics and predictors of thrombus formation, and also demonstrate the potential of using a generic motion model as a surrogate for the more complex patient-specific motion. While the present study considered a single case, the employed CFD framework is entirely open-source and designed for adaptability, allowing for integration of additional models and generic motions., This research was funded, in whole or in part, by The Research Council of Norway through the PARIS project (311117) and by ERACoSysMed under grant agreement no. 643271. We also acknowledge funding by the SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020) under grant agreement no. 101016496. Simulations were performed on the Saga cluster, with resources provided by UNINETT Sigma2—the National Infrastructure for High Performance Computing and Data Storage in Norway, grant number nn9249k, and on the Oracle HPC Cluster stack through Oracle Cloud credits and related resources provided by Oracle for Research.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus

  • Albors, Carlos
  • Mill, Jordi
  • Olivares Miyares, Andy Luis
  • Iriart, Xavier
  • Cochet, Hubert
  • Camara, Oscar
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation., This work was supported by the European Union’s Horizon 2020 research and innovation program SimCardioTest (101016496 to OC), by the programm GEMINI (GA 101136438), and by the Spanish Ministry of Science, Innovation and Universities under the GENERALITAAT, (PID2022-143239OB-I00 to OC). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Geometric deep learning for the assessment of thrombosis risk in the left atrial appendage

  • Morales, Xabier
  • Mill, Jordi
  • Simeon, Guillem
  • Juhl, Kristine Aavild
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., The assessment of left atrial appendage (LAA) thrombogenesis has experienced major advances with the adoption of patient-specific computational fluid dynamics (CFD) simulations. Nonetheless, due to the vast computational resources and long execution times required by fluid dynamics solvers, there is an ever-growing body of work aiming to develop surrogate models of fluid flow simulations based on neural networks. The present study builds on this foundation by developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), linked to the risk of thrombosis, solely from the patient-specific LAA geometry. To this end, we leveraged recent advancements in Geometric DL, which seamlessly extend the unparalleled potential of convolutional neural networks (CNN), to non-Euclidean data such as meshes. The model was trained with a dataset combining 202 synthetic and 54 real LAA, predicting the ECAP distributions instantaneously, with an average mean absolute error of 0.563. Moreover, the resulting framework manages to predict the anatomical features related to higher ECAP values even when trained exclusively on synthetic cases., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Unsupervised machine learning exploration of morphological and haemodynamic indices to predict thrombus formation in the left atrial appendage

  • Saiz-Vivó, Marta
  • Mill, Jordi
  • Harrison, Josquin
  • Jimenez-Perez, Guillermo
  • Legghe, Benoit
  • Iriart, Xavier
  • Cochet, Hubert
  • Piella Fenoy, Gemma
  • Sermesant, Maxime
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., Atrial Fibrillation (AF) is the most common cardiac arrhythmia, and it is associated with an increased risk of embolic stroke. It is known that AF-related thrombus formation occurs predominantly in the left atrial appendage (LAA). However, it is still unknown the structural and functional characteristics of the left atria (LA) that promote low velocities and stagnated blood flow, thus a high risk of thrombogenesis. In this work, we investigated morphological and in-silico haemodynamic indices of the LA and LAA with unsupervised machine learning (ML) techniques, to identify the most relevant features that could subsequently be used to generate thrombus prediction models. A fully automatic pipeline was implemented to extract multiple morphological parameters from a 3D mesh of a LA. Morphological parameters were then combined with particle flow parameters from in-silico fluid simulations. Unsupervised multiple kernel learning (MKL) was used for dimensionality reduction, resulting in a latent space positioning patients based on feature similarity. Clustering applied to the MKL output space estimated clusters with different proportion of thrombus cases. The cluster with the highest risk of thrombus formation was characterised by high values of LAA height, tortuosity and ostium perimeter, as well as total number of flow particles in the LAA and low angle between the LAA and the left superior pulmonary vein, proving the usefulness of unsupervised ML techniques to extract knowledge from the data, and early identify AF patients at higher risk of thrombus formation., This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 101016496 (SimCardioTest).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Sensitivity analysis of in silico fluid simulations to predict thrombus formation after left atrial appendage occlusion

  • Mill, Jordi|||0000-0003-0087-7489
  • Agudelo Montañez, Victor Hugo
  • Olivares, Andy Luis|||0000-0002-7284-0696
  • Pons, Maria Isabel
  • Silva, Etelvino
  • Nuñez-Garcia, Marta|||0000-0001-9349-3059
  • Morales Ferez, Xabier|||0000-0003-1349-2457
  • Arzamendi, Dabit|||0000-0001-7543-5867
  • Freixa, Xavier|||0000-0002-3203-9060
  • Noailly, Jérôme
  • Camara, Oscar|||0000-0002-5125-6132
Atrial fibrillation (AF) is nowadays the most common human arrhythmia and it is consid-ered a marker of an increased risk of embolic stroke. It is known that 99% of AF-related thrombi are generated in the left atrial appendage (LAA), an anatomical structure located within the left atrium (LA). Left atrial appendage occlusion (LAAO) has become a good alternative for nonvalvular AF patients with contraindications to anticoagulants. However, there is a non-negligible number of device-related thrombus (DRT) events, created next to the device surface. In silico fluid simulations can be a powerful tool to better understand the relation between LA anatomy, haemodynamics, and the process of thrombus formation. Despite the increasing literature in LA fluid modelling, a consensus has not been reached yet in the community on the optimal modelling choices and boundary conditions for generating realistic simulations. In this line, we have performed a sensitivity analysis of several boundary conditions scenarios, varying inlet/outlet and LA wall movement configurations, using patient-specific imaging data of six LAAO patients (three of them with DRT at follow-up). Mesh and cardiac cycle convergence were also analysed. The boundary conditions scenario that better predicted DRT cases had echocardiography-based velocities at the mitral valve outlet, a generic pressure wave from an AF patient at the pulmonary vein inlets, and a dynamic mesh approach for LA wall deformation, emphasizing the need for patient-specific data for realistic simulations. The obtained promising results need to be further validated with larger cohorts, ideally with ground truth data, but they already offer unique insights on thrombogenic risk in the left atria.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi|||0000-0003-0087-7489
  • Montoliu, Helena
  • Moustafa, Abdel Hakim|||0000-0001-6077-6888
  • Olivares, Andy Luis|||0000-0002-7284-0696
  • Albors, Carlos
  • Aguado, Ainhoa M.|||0000-0003-3281-4298
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier|||0000-0002-3203-9060
  • Arzamendi, Dabit|||0000-0001-7543-5867
  • Cochet, Hubert
  • Camara, Oscar|||0000-0002-5125-6132
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment.