Skip to main content

COMPUTATIONAL BIOLOGY AND BIOMEDICAL SYSTEMS

PRE2018-084062

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Formación
Call Contratos Predoctorales
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POMPEU FABRA CCT

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Deep learning framework for real-time estimation of in-silico thrombotic risk indices in the left atrial appendage

  • Morales Ferez, Xabier
  • Mill, Jordi
  • Juhl, Kristine Aavild
  • Acebes Pinilla, César
  • Iriart, Xavier
  • Legghe, Benoit
  • Cochet, Hubert
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Patient-specific computational fluid dynamics (CFD) simulations can provide invaluable insight into the interaction of left atrial appendage (LAA) morphology, hemodynamics, and the formation of thrombi in atrial fibrillation (AF) patients. Nonetheless, CFD solvers are notoriously time-consuming and computationally demanding, which has sparked an ever-growing body of literature aiming to develop surrogate models of fluid simulations based on neural networks. The present study aims at developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), an in-silico index linked to the risk of thrombosis, typically derived from CFD simulations, solely from the patient-specific LAA morphology. To this end, a set of popular DL approaches were evaluated, including fully connected networks (FCN), convolutional neural networks (CNN), and geometric deep learning. While the latter directly operated over non-Euclidean domains, the FCN and CNN approaches required previous registration or 2D mapping of the input LAA mesh. First, the superior performance of the graph-based DL model was demonstrated in a dataset consisting of 256 synthetic and real LAA, where CFD simulations with simplified boundary conditions were run. Subsequently, the adaptability of the geometric DL model was further proven in a more realistic dataset of 114 cases, which included the complete patient-specific LA and CFD simulations with more complex boundary conditions. The resulting DL framework successfully predicted the overall distribution of the ECAP in both datasets, based solely on anatomical features, while reducing computational times by orders of magnitude compared to conventional CFD solvers., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme—FI (2020-FI-B-00690) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of the influence of pulmonary vein configuration on left atrial haemodynamics and thrombus formation in a large cohort

  • Mill, Jordi
  • Harrison, Josquin
  • Legghe, Benoit
  • Olivares, Andy L.
  • Morales, Xabier
  • Noailly, Jérôme
  • Iriart, Xavier
  • Cochet, Hubert
  • Sermesant, Maxime
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Moreover, the impact of structures such as the pulmonary veins (PVs) on LA haemodynamics has not been thoroughly studied due to the difficulties of acquiring appropriate data. On the other hand, in-silico studies and flow simulations allow a thorough analysis of haemodynamics, analysing the 4D nature of blood flow patterns under different boundary conditions. However, the reduced number of cases reported on the literature of these studies has been a limitation. The main goal of this work was to study the influence of PVs on left atrium (LA) and LAA haemodynamics. Computational fluid dynamics simulations were run on 52 patients, the largest cohort so far in the literature, where different parameters were individually studied: pulmonary veins orientation and configuration; LAA and LA volumes and its ratio; and flow velocities. Our computational analysis showed how the right pulmonary vein height and angulation have a great influence on LA haemodynamics. Additionally, we found that LAA with great bending with its tip pointing towards the mitral valve could contribute to favour flow stagnation., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496) and the European project PARIS (ID35).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Geometric deep learning for the assessment of thrombosis risk in the left atrial appendage

  • Morales, Xabier
  • Mill, Jordi
  • Simeon, Guillem
  • Juhl, Kristine Aavild
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., The assessment of left atrial appendage (LAA) thrombogenesis has experienced major advances with the adoption of patient-specific computational fluid dynamics (CFD) simulations. Nonetheless, due to the vast computational resources and long execution times required by fluid dynamics solvers, there is an ever-growing body of work aiming to develop surrogate models of fluid flow simulations based on neural networks. The present study builds on this foundation by developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), linked to the risk of thrombosis, solely from the patient-specific LAA geometry. To this end, we leveraged recent advancements in Geometric DL, which seamlessly extend the unparalleled potential of convolutional neural networks (CNN), to non-Euclidean data such as meshes. The model was trained with a dataset combining 202 synthetic and 54 real LAA, predicting the ECAP distributions instantaneously, with an average mean absolute error of 0.563. Moreover, the resulting framework manages to predict the anatomical features related to higher ECAP values even when trained exclusively on synthetic cases., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Towards assisted electrocardiogram interpretation using an AI-enabled Augmented Reality headset

  • Lampreave, Paula
  • Jimenez-Perez, Guillermo
  • Sanz-Pérez, Isidro
  • Gomez, Alberto
  • Camara, Oscar
The interpretation of electrocardiograms (ECGs) is key for the diagnosis and monitoring of cardiovascular health. Despite the progressive digital transformation in healthcare, it is still common for clinicians to analyse ECG printed on paper. Although some systems provide signal processing-based ECG classification, clinicians often find it unreliable. Artificial Intelligence (AI) techniques are becoming state-of-the-art for ECG processing but the lack of digitised ECG has hampered the clinical translation of these techniques. Concurrently, we are living a rise in augmented reality (AR) technologies, with an increasing availability of devices. In this work, we present an automatic digitisation and assisted interpretation of ECG based on an AI-enabled Augmented Reality headset. The AR headset is used to acquire an image of the printed ECG, from which the digitised ECG signal is extracted. Afterwards, the digitised ECG is introduced into a Deep Learning (DL) algorithm pre-trained on a public database of 12-lead ECG recordings. The output of the DL algorithm classifies the ECG signal onto different cardiomyopathy categories, which is then visualized back in the AR headset. Preliminary classification results on simulated ECG images (96.5% of accuracy) confirm the potential of the developed approach to contribute on the digital transformation of ECG processing., This work was supported by the Ministerio de Ciencia, Innovación y Universidades under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Ministerio de Economíay Competitividad under the Programme for the Formation of Doctors (PRE2018-084062). Alberto Gomez acknowl-edges financial support from the Department of Health via the National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre award to Guy’s and St Thomas’ NHS Foundation Trust in partnership with King's College London and King’s College Hospital NHS Foundation Trust.
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

Towards real-time optimization of left atrial appendage occlusion device placement through physics-informed neural networks

  • Morales, Xabier
  • Albors, Carlos
  • Mill, Jordi
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., The adoption of patient-specific computational fluid dynamics (CFD) simulations has been instrumental toward a better understanding of the mechanisms underlying thrombogenesis in the left atrial appendage. Such simulations can help optimize the placement of left atrial appendage occlusion (LAAO) devices in atrial fibrillation patients and avoid the generation of device-related thrombosis. However, integrating conventional solvers into clinical practice is cumbersome, as even the slightest change in model geometry involves computing the entire simulation from scratch. In contrast, neural networks can entirely circumvent this issue by transferring knowledge across models targeted at similar physical domains. Thus, in the present study, we introduced a neural network capable of predicting left atrial hemodynamics under different occlusion device configurations, relying solely on a single finite element simulation for training. To this end, we leveraged physics-informed neural networks (PINN), which embed the physical laws governing the domain of interest into the model, exhibiting far superior generalization capabilities than conventional data-driven models. Several device types and positions have been tested in two distinct left atrial geometries. By employing a single reference simulation per patient the network can predict the updated hemodynamics for a variety of device types and positions, orders of magnitude faster than with conventional CFD solvers., This work was funded by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme - FI (2020 FI_B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and the Retos Investigación project (RTI2018-101193-B-I00), and the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496). Additionally, this research was supported by grants from NVIDIA and utilized NVIDIA RTX A6000.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Joint analysis of morphological parameters and in silico haemodynamics of the left atrial appendage for thrombogenic risk assessment

  • Pons Vidal, Maria Isabel
  • Mill, Jordi
  • Fernandez-Quilez, Álvaro
  • Olivares, Andy L.
  • Silva, Etelvino
  • De Potter, Tom
  • Camara, Oscar
Background. Atrial fibrillation (AF) is considered the most common human arrhythmia. In nonvalvular AF, around 99% of thrombi are formed in the left atrial appendage (LAA). Nevertheless, there is not a consensus in the community about the relevant factors to stratify the AF population according to thrombogenic risk. Objective. To demonstrate the need for combining left atrial morphological and haemodynamics indices to improve the thrombogenic risk assessment in nonvalvular AF patients. Methods. A cohort of 71 nonvalvular AF patients was analysed. Statistical analysis, regression models, and random forests were used to analyse the differences between morphological and haemodynamics parameters, extracted from computational simulations built on 3D rotational angiography images, between patients with and without transient ischemic attack (TIA) or cerebrovascular accident (CVA). Results. The analysis showed that models composed of both morphological and haemodynamic factors were better predictors of TIA/CVA compared with models based on either morphological or haemodynamic factors separately. Maximum ostium diameter, length of the centreline, blood flow velocity within the LAA, oscillatory shear index, and time average wall shear stress parameters were found to be key risk factors for TIA/CVA prediction. In addition, TIA/CVA patients presented more flow stagnation within the LAA. Conclusion. Thrombus formation in the LAA is the result of multiple factors. Analyses based only on morphological or haemodynamic parameters are not precise enough to predict such a phenomenon, as demonstrated in our results; a better patient stratification can be obtained by jointly analysing morphological and haemodynamic features., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888).
Repositorio Digital de la UPF
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of device-related thrombosis for different left atrial appendage occluder settings

  • Planas, Eric
  • Mill, Jordi
  • Olivares, Andy L.
  • Morales, Xabier
  • Pons Vidal, Maria Isabel
  • Iriart, Xavier
  • Cochet, Hubert
  • Camara, Oscar
Comunicació presentada a: 12th International Workshop, STACOM 2021 celebrada del 27 de setembre de 2021 a Strasbourg, França., Atrial fibrillation (AF) is one of the most common cardiac arrhythmias and is associated to an increasing risk of stroke. Most AF- related strokes are formed in the left atrial appendage (LAA). To prevent thrombus formation, LAA occlusion (LAAO) is considered a suitable alternative for AF patients with contraindications for anti-coagulation treatment. Nevertheless, LAAO is linked to a non-negligible risk of gener- ating thrombus at the surface near the device (i.e., device-related throm- bus, DRT), depending on the implantation settings. For instance, it has been shown that not covering the pulmonary ridge (PR) with the LAAO increases the risk of DRT. In-silico analysis is a useful tool to better understand the blood flow patterns after LAAO and predict the risk of DRT for a given patient and device configuration. In the present work we designed a modelling pipeline based on fluid simulations, including a thrombus model using discrete phase modelling, to analyse the risk of DRT in six patient-specific geometries for different LAAO settings. In particular, we studied the possible incidence of DRT depending on the device positioning (covering/uncovering the PR) and type (Amplatzer Amulet and Watchman FLX). The resulting in-silico indices demon- strated that covering the PR entails less thrombogenic patterns than uncovering it. In our study, disk-based devices had better adaptability to complex LAA morphologies and a slightly minor associated risk of DRT than non-disk devices., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Inves- tigaci ́on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi
  • Montoliu, Helena
  • Moustafa, Abdel-Hakim
  • Olivares, Andy L.
  • Albors, Carlos
  • Aguado, Ainhoa M.
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier
  • Arzamendi, Dabit
  • Cochet, Hubert
  • Camara, Oscar
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM 2015-0502), and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062). In addition, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi
  • Montoliu, Helena
  • Moustafa, Abdel-Hakim
  • Olivares, Andy L.
  • Albors, Carlos
  • Aguado, Ainhoa M.
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier
  • Arzamendi, Dabit
  • Cochet, Hubert
  • Camara, Oscar
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM 2015-0502), and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062). In addition, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Deep learning framework for real-time estimation of in-silico thrombotic risk indices in the left atrial appendage

  • Morales Ferez, Xabier
  • Mill, Jordi
  • Juhl, Kristine Aavild
  • Acebes Pinilla, César
  • Iriart, Xavier
  • Legghe, Benoit
  • Cochet, Hubert
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Patient-specific computational fluid dynamics (CFD) simulations can provide invaluable insight into the interaction of left atrial appendage (LAA) morphology, hemodynamics, and the formation of thrombi in atrial fibrillation (AF) patients. Nonetheless, CFD solvers are notoriously time-consuming and computationally demanding, which has sparked an ever-growing body of literature aiming to develop surrogate models of fluid simulations based on neural networks. The present study aims at developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), an in-silico index linked to the risk of thrombosis, typically derived from CFD simulations, solely from the patient-specific LAA morphology. To this end, a set of popular DL approaches were evaluated, including fully connected networks (FCN), convolutional neural networks (CNN), and geometric deep learning. While the latter directly operated over non-Euclidean domains, the FCN and CNN approaches required previous registration or 2D mapping of the input LAA mesh. First, the superior performance of the graph-based DL model was demonstrated in a dataset consisting of 256 synthetic and real LAA, where CFD simulations with simplified boundary conditions were run. Subsequently, the adaptability of the geometric DL model was further proven in a more realistic dataset of 114 cases, which included the complete patient-specific LA and CFD simulations with more complex boundary conditions. The resulting DL framework successfully predicted the overall distribution of the ECAP in both datasets, based solely on anatomical features, while reducing computational times by orders of magnitude compared to conventional CFD solvers., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme—FI (2020-FI-B-00690) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigación project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of the influence of pulmonary vein configuration on left atrial haemodynamics and thrombus formation in a large cohort

  • Mill, Jordi
  • Harrison, Josquin
  • Legghe, Benoit
  • Olivares, Andy L.
  • Morales, Xabier
  • Noailly, Jérôme
  • Iriart, Xavier
  • Cochet, Hubert
  • Sermesant, Maxime
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., Atrial fibrillation (AF) is considered the most common human arrhythmia. Around 99% of thrombi in non-valvular AF are formed in the left atrial appendage (LAA). Studies suggest that abnormal LAA haemodynamics and the subsequently stagnated flow are the factors triggering clot formation. However, the relation between LAA morphology, the blood pattern and the triggering is not fully understood. Moreover, the impact of structures such as the pulmonary veins (PVs) on LA haemodynamics has not been thoroughly studied due to the difficulties of acquiring appropriate data. On the other hand, in-silico studies and flow simulations allow a thorough analysis of haemodynamics, analysing the 4D nature of blood flow patterns under different boundary conditions. However, the reduced number of cases reported on the literature of these studies has been a limitation. The main goal of this work was to study the influence of PVs on left atrium (LA) and LAA haemodynamics. Computational fluid dynamics simulations were run on 52 patients, the largest cohort so far in the literature, where different parameters were individually studied: pulmonary veins orientation and configuration; LAA and LA volumes and its ratio; and flow velocities. Our computational analysis showed how the right pulmonary vein height and angulation have a great influence on LA haemodynamics. Additionally, we found that LAA with great bending with its tip pointing towards the mitral valve could contribute to favour flow stagnation., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496) and the European project PARIS (ID35).
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

In-silico analysis of device-related thrombosis for different left atrial appendage occluder settings

  • Planas, Eric
  • Mill, Jordi
  • Olivares, Andy L.
  • Morales, Xabier
  • Pons Vidal, Maria Isabel
  • Iriart, Xavier
  • Cochet, Hubert
  • Camara, Oscar
Comunicació presentada a: 12th International Workshop, STACOM 2021 celebrada del 27 de setembre de 2021 a Strasbourg, França., Atrial fibrillation (AF) is one of the most common cardiac arrhythmias and is associated to an increasing risk of stroke. Most AF- related strokes are formed in the left atrial appendage (LAA). To prevent thrombus formation, LAA occlusion (LAAO) is considered a suitable alternative for AF patients with contraindications for anti-coagulation treatment. Nevertheless, LAAO is linked to a non-negligible risk of gener- ating thrombus at the surface near the device (i.e., device-related throm- bus, DRT), depending on the implantation settings. For instance, it has been shown that not covering the pulmonary ridge (PR) with the LAAO increases the risk of DRT. In-silico analysis is a useful tool to better understand the blood flow patterns after LAAO and predict the risk of DRT for a given patient and device configuration. In the present work we designed a modelling pipeline based on fluid simulations, including a thrombus model using discrete phase modelling, to analyse the risk of DRT in six patient-specific geometries for different LAAO settings. In particular, we studied the possible incidence of DRT depending on the device positioning (covering/uncovering the PR) and type (Amplatzer Amulet and Watchman FLX). The resulting in-silico indices demon- strated that covering the PR entails less thrombogenic patterns than uncovering it. In our study, disk-based devices had better adaptability to complex LAA morphologies and a slightly minor associated risk of DRT than non-disk devices., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Inves- tigaci ́on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Towards assisted electrocardiogram interpretation using an AI-enabled Augmented Reality headset

  • Lampreave, Paula
  • Jimenez-Perez, Guillermo
  • Sanz-Pérez, Isidro
  • Gomez, Alberto
  • Camara, Oscar
The interpretation of electrocardiograms (ECGs) is key for the diagnosis and monitoring of cardiovascular health. Despite the progressive digital transformation in healthcare, it is still common for clinicians to analyse ECG printed on paper. Although some systems provide signal processing-based ECG classification, clinicians often find it unreliable. Artificial Intelligence (AI) techniques are becoming state-of-the-art for ECG processing but the lack of digitised ECG has hampered the clinical translation of these techniques. Concurrently, we are living a rise in augmented reality (AR) technologies, with an increasing availability of devices. In this work, we present an automatic digitisation and assisted interpretation of ECG based on an AI-enabled Augmented Reality headset. The AR headset is used to acquire an image of the printed ECG, from which the digitised ECG signal is extracted. Afterwards, the digitised ECG is introduced into a Deep Learning (DL) algorithm pre-trained on a public database of 12-lead ECG recordings. The output of the DL algorithm classifies the ECG signal onto different cardiomyopathy categories, which is then visualized back in the AR headset. Preliminary classification results on simulated ECG images (96.5% of accuracy) confirm the potential of the developed approach to contribute on the digital transformation of ECG processing., This work was supported by the Ministerio de Ciencia, Innovación y Universidades under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Ministerio de Economíay Competitividad under the Programme for the Formation of Doctors (PRE2018-084062). Alberto Gomez acknowl-edges financial support from the Department of Health via the National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre award to Guy’s and St Thomas’ NHS Foundation Trust in partnership with King's College London and King’s College Hospital NHS Foundation Trust.
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Towards real-time optimization of left atrial appendage occlusion device placement through physics-informed neural networks

  • Morales, Xabier
  • Albors, Carlos
  • Mill, Jordi
  • Camara, Oscar
Comunicació presentada a 13th International Workshop, STACOM 2022, conjuntament amb MICCAI 2022, celebrada el 18 de setembre de 2022 a Singapur., The adoption of patient-specific computational fluid dynamics (CFD) simulations has been instrumental toward a better understanding of the mechanisms underlying thrombogenesis in the left atrial appendage. Such simulations can help optimize the placement of left atrial appendage occlusion (LAAO) devices in atrial fibrillation patients and avoid the generation of device-related thrombosis. However, integrating conventional solvers into clinical practice is cumbersome, as even the slightest change in model geometry involves computing the entire simulation from scratch. In contrast, neural networks can entirely circumvent this issue by transferring knowledge across models targeted at similar physical domains. Thus, in the present study, we introduced a neural network capable of predicting left atrial hemodynamics under different occlusion device configurations, relying solely on a single finite element simulation for training. To this end, we leveraged physics-informed neural networks (PINN), which embed the physical laws governing the domain of interest into the model, exhibiting far superior generalization capabilities than conventional data-driven models. Several device types and positions have been tested in two distinct left atrial geometries. By employing a single reference simulation per patient the network can predict the updated hemodynamics for a variety of device types and positions, orders of magnitude faster than with conventional CFD solvers., This work was funded by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the Grants for the Contracting of New Research Staff Programme - FI (2020 FI_B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and the Retos Investigación project (RTI2018-101193-B-I00), and the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1-DTH-06-2020; grant agreement No. 101016496). Additionally, this research was supported by grants from NVIDIA and utilized NVIDIA RTX A6000.
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Geometric deep learning for the assessment of thrombosis risk in the left atrial appendage

  • Morales, Xabier
  • Mill, Jordi
  • Simeon, Guillem
  • Juhl, Kristine Aavild
  • De Backer, Ole
  • Paulsen, Rasmus R.
  • Camara, Oscar
Comunicació presentada a: FIMH 2021 11th International Conference, celebrada del 21 al 25 de juny de 2021 a Stanford, CA, USA., The assessment of left atrial appendage (LAA) thrombogenesis has experienced major advances with the adoption of patient-specific computational fluid dynamics (CFD) simulations. Nonetheless, due to the vast computational resources and long execution times required by fluid dynamics solvers, there is an ever-growing body of work aiming to develop surrogate models of fluid flow simulations based on neural networks. The present study builds on this foundation by developing a deep learning (DL) framework capable of predicting the endothelial cell activation potential (ECAP), linked to the risk of thrombosis, solely from the patient-specific LAA geometry. To this end, we leveraged recent advancements in Geometric DL, which seamlessly extend the unparalleled potential of convolutional neural networks (CNN), to non-Euclidean data such as meshes. The model was trained with a dataset combining 202 synthetic and 54 real LAA, predicting the ECAP distributions instantaneously, with an average mean absolute error of 0.563. Moreover, the resulting framework manages to predict the anatomical features related to higher ECAP values even when trained exclusively on synthetic cases., This work was supported by the Agency for Management of University and Research Grants of the Generalitat de Catalunya under the the Grants for the Contracting of New Research Staff Programme - FI (2020 FI B 00608) and the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502) and the Retos Investigaci´on project (RTI2018-101193-B-I00). Additionally, this work was supported by the H2020 EU SimCardioTest project (Digital transformation in Health and Care SC1- DTH-06-2020; grant agreement No. 101016496).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Joint analysis of morphological parameters and in silico haemodynamics of the left atrial appendage for thrombogenic risk assessment

  • Pons Vidal, Maria Isabel
  • Mill, Jordi
  • Fernandez-Quilez, Álvaro
  • Olivares, Andy L.
  • Silva, Etelvino
  • De Potter, Tom
  • Camara, Oscar
Background. Atrial fibrillation (AF) is considered the most common human arrhythmia. In nonvalvular AF, around 99% of thrombi are formed in the left atrial appendage (LAA). Nevertheless, there is not a consensus in the community about the relevant factors to stratify the AF population according to thrombogenic risk. Objective. To demonstrate the need for combining left atrial morphological and haemodynamics indices to improve the thrombogenic risk assessment in nonvalvular AF patients. Methods. A cohort of 71 nonvalvular AF patients was analysed. Statistical analysis, regression models, and random forests were used to analyse the differences between morphological and haemodynamics parameters, extracted from computational simulations built on 3D rotational angiography images, between patients with and without transient ischemic attack (TIA) or cerebrovascular accident (CVA). Results. The analysis showed that models composed of both morphological and haemodynamic factors were better predictors of TIA/CVA compared with models based on either morphological or haemodynamic factors separately. Maximum ostium diameter, length of the centreline, blood flow velocity within the LAA, oscillatory shear index, and time average wall shear stress parameters were found to be key risk factors for TIA/CVA prediction. In addition, TIA/CVA patients presented more flow stagnation within the LAA. Conclusion. Thrombus formation in the LAA is the result of multiple factors. Analyses based only on morphological or haemodynamic parameters are not precise enough to predict such a phenomenon, as demonstrated in our results; a better patient stratification can be obtained by jointly analysing morphological and haemodynamic features., This work was supported by the Spanish Ministry of Science, Innovation and Universities under the Retos I+D Programme (RTI2018-101193-B-I00), the Maria de Maeztu Units of Excellence Programme (MDM-2015-0502), the Spanish Ministry of Economy and Competitiveness under the Programme for the Formation of Doctors (PRE2018-084062), and MINECO (RYC-2015-18888).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Sensitivity analysis of in silico fluid simulations to predict thrombus formation after left atrial appendage occlusion

  • Mill, Jordi|||0000-0003-0087-7489
  • Agudelo Montañez, Victor Hugo
  • Olivares, Andy Luis|||0000-0002-7284-0696
  • Pons, Maria Isabel
  • Silva, Etelvino
  • Nuñez-Garcia, Marta|||0000-0001-9349-3059
  • Morales Ferez, Xabier|||0000-0003-1349-2457
  • Arzamendi, Dabit|||0000-0001-7543-5867
  • Freixa, Xavier|||0000-0002-3203-9060
  • Noailly, Jérôme
  • Camara, Oscar|||0000-0002-5125-6132
Atrial fibrillation (AF) is nowadays the most common human arrhythmia and it is consid-ered a marker of an increased risk of embolic stroke. It is known that 99% of AF-related thrombi are generated in the left atrial appendage (LAA), an anatomical structure located within the left atrium (LA). Left atrial appendage occlusion (LAAO) has become a good alternative for nonvalvular AF patients with contraindications to anticoagulants. However, there is a non-negligible number of device-related thrombus (DRT) events, created next to the device surface. In silico fluid simulations can be a powerful tool to better understand the relation between LA anatomy, haemodynamics, and the process of thrombus formation. Despite the increasing literature in LA fluid modelling, a consensus has not been reached yet in the community on the optimal modelling choices and boundary conditions for generating realistic simulations. In this line, we have performed a sensitivity analysis of several boundary conditions scenarios, varying inlet/outlet and LA wall movement configurations, using patient-specific imaging data of six LAAO patients (three of them with DRT at follow-up). Mesh and cardiac cycle convergence were also analysed. The boundary conditions scenario that better predicted DRT cases had echocardiography-based velocities at the mitral valve outlet, a generic pressure wave from an AF patient at the pulmonary vein inlets, and a dynamic mesh approach for LA wall deformation, emphasizing the need for patient-specific data for realistic simulations. The obtained promising results need to be further validated with larger cohorts, ideally with ground truth data, but they already offer unique insights on thrombogenic risk in the left atria.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Domain expert evaluation of advanced visual computing solutions and 3D printing for the planning of the left atrial appendage occluder interventions

  • Mill, Jordi|||0000-0003-0087-7489
  • Montoliu, Helena
  • Moustafa, Abdel Hakim|||0000-0001-6077-6888
  • Olivares, Andy Luis|||0000-0002-7284-0696
  • Albors, Carlos
  • Aguado, Ainhoa M.|||0000-0003-3281-4298
  • Medina, Elodie
  • Ceresa, Mario
  • Freixa, Xavier|||0000-0002-3203-9060
  • Arzamendi, Dabit|||0000-0001-7543-5867
  • Cochet, Hubert
  • Camara, Oscar|||0000-0002-5125-6132
Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment.