Skip to main content

RED DE POSICIONAMIENTO Y NAVEGACION EN INTERIORES Y EXTERIORES RESTRINGIDOS Y SUS APLICACIONES

RED2022-134355-T

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Redes Investigación /Redes Excelencia
Call year 2022
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ALCALA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

e_Buah Biblioteca Digital Universidad de Alcalá
Publication Contribución de congreso (ConferenceOutput)

6-DoF optical positioning system with RSS-AoA measurements and Harmony Search refinement

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Moltó Orozco, David|||0000-0002-2790-3758
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
IPIN-WCAL 2025 Indoor Positioning and Indoor Navigation - Workshop for Computing & Advanced Localization 2025, at the 15th International Conference on Indoor Positioning and Indoor Navigation (IPIN 2025), Tampere, Finland, September 15 - 18, 2025., Indoor localization is an ever-growing area of research, driven by applications such as autonomous robot navigation, cultural and commercial venue guidance, logistics, emergency response, and health monitoring of older adults. This paper presents a two-stage hybrid method for the full six degrees-of-freedom (6-DoF) pose estimation in optical indoor localization systems using a quadrant photodiode (QP) sensor. First, a geometric Angle-of-Arrival (AoA) algorithm estimates the receiver’s 3D position and yaw rotation using normalized energy ratios. Then, a Harmony Search (HS) algorithm refines this partial estimation to full 6-DoF by estimating the roll and pitch angles, while simultaneously refining all pose parameters through reprojection error minimization. The method is validated through simulations over a 2 × 2 × 1 m³ volume. Results show that the proposed approach significantly outperforms the AoA-only baseline. In scenarios with different orientations, the 90-th percentile position error drops from 0.61 m to 0.38 m in the x and y coordinates, and from 0.24 m to 0.20 m in the z one. Orientation errors in roll, pitch, and yaw are below 6.56°, 6.48°, and 1.03°, respectively., Agencia Estatal de Investigación