Skip to main content

RED DE POSICIONAMIENTO Y NAVEGACION EN INTERIORES Y EXTERIORES RESTRINGIDOS Y SUS APLICACIONES

RED2022-134355-T

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Redes Investigación /Redes Excelencia
Call year 2022
State Plan 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ALCALA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Efficacy, safety, and evaluation criteria of mHealth interventions for depression, systematic review

  • Duarte-Díaz, Andrea|||0000-0003-1171-9945
  • Perestelo-Pérez, Lilisbeth|||0000-0002-6113-7313
  • Gelabert, Estel|||0000-0001-5897-1932
  • Robles, Noemí|||0000-0003-0740-9098
  • Pérez-Navarro, Antoni|||0000-0002-7037-0635
  • Vidal-Alaball, Josep|||0000-0002-3527-4242
  • Solà-Morales, Oriol|||0000-0002-8312-8178
  • Sales Masnou, Ariadna|||0009-0002-3602-7216
  • Carrion, Carme|||0000-0003-1479-7551
Background: Depression is a significant public health issue that can lead to considerable disability and reduced quality of life. With the rise of technology, mobile health (mHealth) interventions, particularly smartphone apps, are emerging as a promising approach for addressing depression. However, the lack of standardized evaluation tools and evidence-based principles for these interventions remains a concern. Objective: In this systematic review and meta-analysis, we aimed to evaluate the efficacy and safety of mHealth interventions for depression and identify the criteria and evaluation tools used for their assessment. Methods: A systematic review and meta-analysis of the literature was carried out following the recommendations of the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. Studies that recruited adult patients exhibiting elevated depressive symptoms or those diagnosed with depressive disorders and aimed to assess the effectiveness or safety of mHealth interventions were eligible for consideration. The primary outcome of interest was the reduction of depressive symptoms, and only randomized controlled trials (RCTs) were included in the analysis. The risk of bias in the original RCTs was assessed using version 2 of the Cochrane risk-of-bias tool for randomized trials. Results: A total of 29 RCTs were included in the analysis after a comprehensive search of electronic databases and manual searches. The efficacy of mHealth interventions in reducing depressive symptoms was assessed using a random effects meta-analysis. In total, 20 RCTs had an unclear risk of bias and 9 were assessed as having a high risk of bias. The most common element in mHealth interventions was psychoeducation, followed by goal setting and gamification strategies. The meta-analysis revealed a significant effect for mHealth interventions in reducing depressive symptoms compared with nonactive control (Hedges g=−0.62, 95% CI −0.87 to −0.37, I 2=87%). Hybrid interventions that combined mHealth with face-to-face sessions were found to be the most effective. Three studies compared mHealth interventions with active controls and reported overall positive results. Safety analyses showed that most studies did not report any study-related adverse events. Conclusions: This review suggests that mHealth interventions can be effective in reducing depressive symptoms, with hybrid interventions achieving the best results. However, the high level of heterogeneity in the characteristics and components of mHealth interventions indicates the need for personalized approaches that consider individual differences, preferences, and needs. It is also important to prioritize evidence-based principles and standardized evaluation tools for mHealth interventions to ensure their efficacy and safety in the treatment of depression. Overall, the findings of this study support the use of Health interventions as a viable method for delivering mental health care.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Greenhouse-scale proximity-RFID system enabling flower-visit metrics for bumblebee pollination studies under climate change

  • Jiménez Ruiz, Antonio R.
  • Pilla Barroso, Melisa Janela
  • Serrano Rodriguez, Julián
  • Seco Granja, Fernando
  • Ruiz-Ruiz, Luisa
  • Ormazabal, Maialen
  • Guerrero, Juan José
  • Prudencio, Ángela S.
  • Martín Rodríguez, J. A.
  • Pérez-Alfocea, Francisco
Bumblebee pollination is critical for crop production, yet monitoring their visitation patterns at crop scale with flower-level resolution remains a major challenge. This study presents a novel proximity radio-frequency identification (RFID) system designed to quantify pollination activity in a greenhouse environment. A dense network of 42 readers and 336 custom ring-shaped antennas was deployed over 1200 m2 to enable continuous detection of 154 tagged bumblebees during an eight-week campaign. More than 1.2 million detections were processed into 14,288 discrete visits, including their duration and frequency, allowing detailed characterization of pollinator activity. The system was demonstrated in a tomato crop under both control and simulated heat-stress conditions, showing robust performance and the ability to capture shifts in pollination activity in response to environmental stressors. To our knowledge, this work provides the first greenhouse-scale RFID framework capable of resolving visit-level pollination events, offering new opportunities to study crop–pollinator interactions under different scenarios., This work was supported by the European Union Horizon 2020 project DARkWIN (Grant Agreement No. 122642OB-C43), REPNIN++ (RED2022-134355-T), both funded by MCIN/AEI/10.13039/501100011033, and Fudación Séneca Science and Technology Agency of the Region of Murcia for a predoctoral fellowship to JJGF (21796/FPI/22)., Peer reviewed
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Vehicular visible light positioning system based on a PSD detector

  • Raissouni Germim, Fátima Zahra
  • Llana Calvo, Álvaro de la|||0000-0002-8889-0452
  • Lázaro Galilea, José Luis|||0000-0001-5048-7134
  • Gardel Vicente, Alfredo|||0000-0001-7887-4689
  • Cherkaoui, Abdeljabbar
  • Bravo Muñoz, Ignacio|||0000-0002-6964-0036
In this paper, we explore the use of visible light positioning (VLP) technology in vehicles in intelligent transportation systems (ITS), highlighting its potential for maintaining effective line of sight (LOS) and providing high-accuracy positioning between vehicles. The proposed system (V2V-VLP) is based on a position-sensitive detector (PSD) and exploiting car taillights to determine the position and inter-vehicular distance by angle of arrival (AoA) measurements. The integration of the PSD sensor in vehicles promises exceptional positioning accuracy, opening new prospects for navigation and driving safety. The results revealed that the proposed system enables precise measurement of position and distance between vehicles, including lateral distance. We evaluated the impact of different focal lengths on the system performance, achieving cm-level accuracy for distances up to 35 m, with an optimum focal length of 25 mm, and under low signal-to-noise conditions, which meets the standards required for safe and reliable V2V applications. Several experimental tests were carried out to validate the results of the simulations., Agencia Estatal de Investigación, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Vehicle-to-vehicle VLC based on PSD sensor: system modeling and effects of multipath in unfavorable situations

  • Raissouni Germim, Fátima Zahra
  • Llana Calvo, Álvaro de la|||0000-0002-8889-0452
  • Lázaro Galilea, José Luis|||0000-0001-5048-7134
  • Gardel Vicente, Alfredo|||0000-0001-7887-4689
  • Cherkaoui, Abdeljabbar
Vehicular communication based visible light presents an excellent solution to ensure road safety and transportation efficiency in critical environments like tunnels, underground garages, or covered parking lots where traditionally RF solutions cannot provide an efficient communication. In this paper, we propose a new multipath channel model for V2V-VLC in unfavorable situations like in tunnels by using a PSD sensor. The performance of the derived channel model is evaluated using statistical measures based on numerical simulations in terms of channel impulse response, channel DC gain and RMS delay spread to quantify the effects of multipath propagation. Monte Carlo simulation is also used to explore the statistical model obtained for different transmission scenarios. Additionally, we evaluate the influence of various model parameters, such as road width and inter-vehicular distance, on the performance of the V2V channel. The main results are compared with typical Lambertian reflector model to confirm the validity of the proposed model., Universidad de Alcalá, Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Contribución de congreso (ConferenceOutput)

6-DoF optical positioning system with RSS-AoA measurements and Harmony Search refinement

  • Aparicio Esteve, Elena|||0000-0001-7886-312X
  • Moltó Orozco, David|||0000-0002-2790-3758
  • Hernández Alonso, Álvaro|||0000-0001-9308-8133
  • Ureña Ureña, Jesús|||0000-0003-1408-6039
IPIN-WCAL 2025 Indoor Positioning and Indoor Navigation - Workshop for Computing & Advanced Localization 2025, at the 15th International Conference on Indoor Positioning and Indoor Navigation (IPIN 2025), Tampere, Finland, September 15 - 18, 2025., Indoor localization is an ever-growing area of research, driven by applications such as autonomous robot navigation, cultural and commercial venue guidance, logistics, emergency response, and health monitoring of older adults. This paper presents a two-stage hybrid method for the full six degrees-of-freedom (6-DoF) pose estimation in optical indoor localization systems using a quadrant photodiode (QP) sensor. First, a geometric Angle-of-Arrival (AoA) algorithm estimates the receiver’s 3D position and yaw rotation using normalized energy ratios. Then, a Harmony Search (HS) algorithm refines this partial estimation to full 6-DoF by estimating the roll and pitch angles, while simultaneously refining all pose parameters through reprojection error minimization. The method is validated through simulations over a 2 × 2 × 1 m³ volume. Results show that the proposed approach significantly outperforms the AoA-only baseline. In scenarios with different orientations, the 90-th percentile position error drops from 0.61 m to 0.38 m in the x and y coordinates, and from 0.24 m to 0.20 m in the z one. Orientation errors in roll, pitch, and yaw are below 6.56°, 6.48°, and 1.03°, respectively., Agencia Estatal de Investigación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Seamless mobile indoor navigation with VLP-PDR

  • Alcázar Fernández, Aitor|||0000-0002-1297-8343
  • Llana Calvo, Álvaro de la|||0000-0002-8889-0452
  • Lázaro Galilea, José Luis|||0000-0001-5048-7134
  • Pérez Navarro, Antoni
  • Gil Vera, Rubén|||0000-0002-5579-6718
  • Gardel Vicente, Alfredo|||0000-0001-7887-4689
This study unveils a mobile app-based indoor positioning system (IPS) tailored for seamless museum navigation. Leveraging smartphone inertial measurement unit (IMU) sensors, it incorporates a pedestrian dead reckoning (PDR) algorithm and a visible light positioning (VLP) beacon-based angle of arrival (AoA) algorithm for precise user positioning relative to smart light sources. In standalone mode, the VLP AoA-based algorithm demonstrates reliability with a mean error of 10.64 cm, while the PDR algorithm, operating independently, exhibits mean error of 3 m influenced by environmental factors. Integration of both algorithms proves crucial in mitigating cumulative errors. By updating PDR deviations with the precision provided by the VLP AoA-based solution, the entire system minimizes its mean error to 0.85 m. The user-friendly interface not only enriches visitor experiences with contextual information but also enables intuitive navigation without continuous internet connectivity. This innovative solution caters to the critical demand for precise indoor navigation, particularly in museum environments, fostering increased user acceptance and utilization., Universidad de Alcalá, Agencia Estatal de Investigación