Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Life-cycle cost of CFRP and steel prestressed concrete elements

  • Bairán García, Jesús Miguel|||0000-0003-2831-1479
  • Murcia Delso, Juan|||0000-0001-6424-7262
  • Duarte Gómez, Noemí|||0000-0002-4542-8487
  • Oller Ibars, Eva|||0000-0002-0845-3587
  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
Carbon steel reinforcement is vulnerable to corrosion, degrading the structure with time, and has large economic implications for aging infrastructures. CFRP is an alternative in reinforced and prestressed concrete, not prone to corrosion. However, its cost is considerably larger than steel, and its mechanical properties enforce different design criteria. Therefore, it is not evident when CFRP is a convenient solution. In this paper, benefits of CFRP reinforcement are investigated in LCC context. An archetype prestressed-concrete bridge is designed with the two types of reinforcement. Two environment scenarios are analyzed, representative of current and increased chloride concentration in coastal regions. The costs investigated include routine inspections, major repairs and users’ affectation. Although requiring less maintenance cost, the design with CFRP has a higher LCC that the steel-reinforced alternative, in the current chloride scenario close to the coast. However, in scenarios of larger chloride exposure, the CFRP solution may be more competitive., This study was developed in the scope of research projects PID2021-123701OB-C21, funded by MCIN/ AEI/10.13039/501100011033 and European Regional Development Funds (ERDF) “A way to make Europe”, and TED2021-130272B-C21 funded by MCIN/ AEI/10.13039/501100011033 “European Union NextGenerationEU/PRTR”.
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Model code approach to the SLS design of FRP reinforced concrete elements

  • Torres Llinàs, Lluís
  • Guadagnini, Maurizio
  • Barris Peña, Cristina
  • Matthys, Stijn
  • Oller Ibars, Eva|||0000-0002-0845-3587
  • Baena Muñoz, Marta
Though research on FRP reinforcement has led to the development of several design recommendations over the past 25 years, recent efforts have focused on the development of unified design procedures and models that can account for the effect of both conventional steel and advanced FRP reinforcement. Examples of such efforts are testament to the level of maturity reached by this novel reinforcing solution and will facilitate a more widespread adoption of FRP reinforcement. The relatively lower modulus of elasticity of FRP materials compared to steel reinforcement may lead to large strains, crack widths and deflections, and as a consequence the design FRP reinforced concrete structures is often governed by serviceability requirements. This paper outlines the principles underlying the recommendations for the serviceability limit state design of FRP reinforced concrete structures included in the next generation of Model Code, discussing merits and limitations as well as comparing to other relevant proposals., Support provided by Spanish Ministry of Science and Innovation (MCIN/ AEI) and by European Funds for Regional Development through projects PID2020‐119015GB‐C22, RTI2018–097314-B-C21 and PID2021-123701OB-C21 is acknowledged.
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Shear strength assessment of FRP pre-tensioned concrete beams

  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
  • Oller Ibars, Eva|||0000-0002-0845-3587
  • Murcia Delso, Juan|||0000-0001-6424-7262
  • Bairán García, Jesús Miguel|||0000-0003-2831-1479
  • Duarte Gómez, Noemí|||0000-0002-4542-8487
The low susceptibility to corrosion of fiber reinforced composite materials (FRP) has led to considering their use for prestressing reinforcement, as an alternative to steel. However, the effects of FRP fragility, low elastic modulus, and low bond with concrete, when compared to usual prestressing steel, must be accounted for in the design of structures. This paper presents a theoretical model for predicting the shear strength of FRP prestressed pre-tensioned concrete beams, extending a previously developed model (CCCM), to account for the properties of FRP as active reinforcement, and to capture reductions in shear strength caused by bond loss in the FRP tendons. The model has been validated by comparing the theoretical predictions with the results of shear tests available in the literature. Good accuracy has been obtained in predicting the shear capacity and also in identifying those cases where shear failure is associated to loss of anchorage bond., The study presented in this paper was developed in the scope of research projects RTI2018-097314-B-C21 and PID2021-123701OB-C21 funded by the Spanish Ministry of Science and Innovation and the European Regional Development Funds (ERDF).
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Reducing eccentricity in plan-irregular buildings through an innovative stiffening solution of the façade frames

  • Moyano, Gabriel
  • Bairán García, Jesús Miguel|||0000-0003-2831-1479
Adjusting to architectonic and urbanistic constraints in dense cities frequently require plan irregularities in structures. One recurrent case in many cities is the combination of a frame in the façade, to allow parking access, with structural walls in other perimeter axes, for drift control. In long structures, this solution creates large eccentricities between the mass and stiffness centres. This paper investigates one solution that significantly increases the stiffness of the façade frame, without affecting its functionality. The concept consists on creating vertical elements in the inner spans of the intermittent stories, producing a Vierendeel-effect in the frame. The stiffer frame closes the distance between the centres of stiffness and mass. The behaviour and possible variation of the failure mode are discussed in the paper, and recommendations for the capacity design of the façade frame are given. It is found that the additional vertical element does not contribute in the gravity load system; hence, it should not be considered as an intermittent column irregularity. This concept is applied to a 10-story plan-irregular building, with hypothetical location in Lima (Perú), and its seismic performance is assessed. Compared to the original solution, the maximum floor displacement was reduced up to 30%. The dominant period of vibration was reduced up to 15%. The recommended capacity-design condition allowed ductile behaviour without local collapse for demands larger than the MCE., The authors acknowledge support of the Spanish State Research Agency and the European Funds for Regional Development, through the research project RTI2018-097314-BC21.
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Mechanical model for the shear strength of steel fibers reinforced concrete beams (SFRC) without stirrups, Modelo mecánico para la resistencia a cortante de vigas de hormigón armado reforzado con fibras, sin armadura de cortante

  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
  • Spinella, Nino
  • Recupero, Antonino
  • Cladera Bohigas, Antoni
Despite the numerous studies made showing that the addition of steel fibres to concrete enhances the shear strength of RC beams, current design formulations are still empirical and present large scatter in front of the test results. In this paper, the previously developed Multi-Action Shear Model is extended to SFRC beams without stirrups, adopting an analytical formulation to evaluate the residual tensile stress of SFRC and incorporating the effects of the crack bridging capacity of SFRC in the shear resisted trough the different shear-transfer mechanisms. The proposed model predicts the tests results included in a recently published database with 448 shear tests with less scatter than any of the existing models., The financial support provided by the University of Messina (Italy), through the scholarship granted for a two-months research and teaching stage of the first author, is acknowledged. This work is part of the Research Projects BIA2015-64672-C4-1-R, funded by the Spanish Ministry of Economy and competitiveness, and RTI2018-097314-B-C21, funded by the Spanish Ministry of Science and Innovation.
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Experimental study on the performance of fibre reinforced polymer pretensioned concrete beams

  • Ortiz Bernal, Galo Fabian|||0000-0002-9823-1637
  • Oller Ibars, Eva|||0000-0002-0845-3587
  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
The use of FRP tendons as an alternative to conventional steel strands in prestressed concrete structures is very limited. There are many aspects that are still not clear enough to establish the basis of design of FRP prestressed concrete structures. To contribute to increase the current knowledge about the performance of this type of structures, an experimental campaign of tests on precast FRP pre-tensioned simply supported beams, without stirrups, is currently under development. The main purpose of this program was to study their performance at service and ultimate load levels. The experimental program includes 15 beams tested under flexure and shear, using steel, CFRP (carbon), GFRP (glass) rebars as active reinforcement, with different levels of prestressing force. Eight out of the fifteen beams have been tested in a 3-point bending configuration and failed unexpectedly in shear at an applied load lower than that predicted. The remaining seven beams have been tested in shear by applying a point load twice at both beam ends. This paper summarizes the preliminary results obtained in this program., The authors acknowledge 1the support provided by Spanish Ministry of Science and Innovation (MCIN/ AED and by the :European Funds for Regional Development in thefollowingprojects RTI2018-097314-B-C21, and PID2021-1237010B-C21. Theauthors would like to acknowledge Sireg for their courtesy supplying the different FRP embedded reinforcement used in the experimental programs.
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Experimental bond performance of fibre reinforced polymer prestressed concrete elements

  • Oller Ibars, Eva|||0000-0002-0845-3587
  • Ortiz Bernal, Galo Fabian|||0000-0002-9823-1637
  • Várzea, Nuno
  • Murcia Delso, Juan|||0000-0001-6424-7262
  • Marí Bernat, Antonio Ricardo|||0000-0002-0994-0715
In pretensioned prestressed concrete elements, bond between reinforcement and concrete differs is fundamental for a safe design. The so-called Hoyer effect, produced by the lateral expansion of a material when subjected to load, increases the bond resistance, but it also increases the circumferential stresses and then, the risk of cracking due to the tendon expansion. The bond behaviour of FRP tendons has not been studied in depth. To study the bond performance of FRP tendons, and characterize the transfer and flexural development length, an experimental program was carried out. This program was based on a setup called ECADA developed for steel tendons by the Universidad Politécnica de Valencia. The test specimen represents the anchorage area of the tendon and the remaining part of the theoretical beam is substituted by an anchorage measurement access system that has the same rigidity of the replaced part. The test starts by prestressing from one side and after concreting, the prestressed force is released gradually, then the transfer length is measured. Afterwards, the tendon is pulled from the other side, and the total development length is determined iteratively by producing samples of different lengths. The results of the ECADA tests have indicated that the transfer lengths of the FRP tendons being studied lie within 100 and 300 mm., The authors acknowledge the support provided by Spanish Ministry of Science and Innovation (MCIN/AEI) and by the European Funds for Regional Development in the following projects RTI2018-097314-B-C21, and PID2021-123701OB-C21. The authors would like to acknowledge Sireg for their courtesy supplying the different FRP embedded reinforcement used in the experimental programs.
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Life-cycle cost of CFRP and steel prestressed concrete elements

  • Bairán García, Jesús Miguel
  • Murcia Delso, Juan
  • Duarte Gómez, Noemí
  • Oller Ibars, Eva
  • Marí Bernat, Antonio Ricardo
Carbon steel reinforcement is vulnerable to corrosion, degrading the structure with time, and has large economic implications for aging infrastructures. CFRP is an alternative in reinforced and prestressed concrete, not prone to corrosion. However, its cost is considerably larger than steel, and its mechanical properties enforce different design criteria. Therefore, it is not evident when CFRP is a convenient solution. In this paper, benefits of CFRP reinforcement are investigated in LCC context. An archetype prestressed-concrete bridge is designed with the two types of reinforcement. Two environment scenarios are analyzed, representative of current and increased chloride concentration in coastal regions. The costs investigated include routine inspections, major repairs and users’ affectation. Although requiring less maintenance cost, the design with CFRP has a higher LCC that the steel-reinforced alternative, in the current chloride scenario close to the coast. However, in scenarios of larger chloride exposure, the CFRP solution may be more competitive., This study was developed in the scope of research projects PID2021-123701OB-C21, funded by MCIN/ AEI/10.13039/501100011033 and European Regional Development Funds (ERDF) “A way to make Europe”, and TED2021-130272B-C21 funded by MCIN/ AEI/10.13039/501100011033 “European Union NextGenerationEU/PRTR”., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Shear strength assessment of FRP pre-tensioned concrete beams

  • Marí Bernat, Antonio Ricardo
  • Oller Ibars, Eva
  • Murcia Delso, Juan
  • Bairán García, Jesús Miguel
  • Duarte Gómez, Noemí
The low susceptibility to corrosion of fiber reinforced composite materials (FRP) has led to considering their use for prestressing reinforcement, as an alternative to steel. However, the effects of FRP fragility, low elastic modulus, and low bond with concrete, when compared to usual prestressing steel, must be accounted for in the design of structures. This paper presents a theoretical model for predicting the shear strength of FRP prestressed pre-tensioned concrete beams, extending a previously developed model (CCCM), to account for the properties of FRP as active reinforcement, and to capture reductions in shear strength caused by bond loss in the FRP tendons. The model has been validated by comparing the theoretical predictions with the results of shear tests available in the literature. Good accuracy has been obtained in predicting the shear capacity and also in identifying those cases where shear failure is associated to loss of anchorage bond., The study presented in this paper was developed in the scope of research projects RTI2018-097314-B-C21 and PID2021-123701OB-C21 funded by the Spanish Ministry of Science and Innovation and the European Regional Development Funds (ERDF)., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Experimental study on the performance of fibre reinforced polymer pretensioned concrete beams

  • Ortiz Bernal, Galo Fabian
  • Oller Ibars, Eva
  • Marí Bernat, Antonio Ricardo
The use of FRP tendons as an alternative to conventional steel strands in prestressed concrete structures is very limited. There are many aspects that are still not clear enough to establish the basis of design of FRP prestressed concrete structures. To contribute to increase the current knowledge about the performance of this type of structures, an experimental campaign of tests on precast FRP pre-tensioned simply supported beams, without stirrups, is currently under development. The main purpose of this program was to study their performance at service and ultimate load levels. The experimental program includes 15 beams tested under flexure and shear, using steel, CFRP (carbon), GFRP (glass) rebars as active reinforcement, with different levels of prestressing force. Eight out of the fifteen beams have been tested in a 3-point bending configuration and failed unexpectedly in shear at an applied load lower than that predicted. The remaining seven beams have been tested in shear by applying a point load twice at both beam ends. This paper summarizes the preliminary results obtained in this program., The authors acknowledge 1the support provided by Spanish Ministry of Science and Innovation (MCIN/ AED and by the :European Funds for Regional Development in thefollowingprojects RTI2018-097314-B-C21, and PID2021-1237010B-C21. Theauthors would like to acknowledge Sireg for their courtesy supplying the different FRP embedded reinforcement used in the experimental programs., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Reducing eccentricity in plan-irregular buildings through an innovative stiffening solution of the façade frames

  • Moyano, Gabriel
  • Bairán García, Jesús Miguel
Adjusting to architectonic and urbanistic constraints in dense cities frequently require plan irregularities in structures. One recurrent case in many cities is the combination of a frame in the façade, to allow parking access, with structural walls in other perimeter axes, for drift control. In long structures, this solution creates large eccentricities between the mass and stiffness centres. This paper investigates one solution that significantly increases the stiffness of the façade frame, without affecting its functionality. The concept consists on creating vertical elements in the inner spans of the intermittent stories, producing a Vierendeel-effect in the frame. The stiffer frame closes the distance between the centres of stiffness and mass. The behaviour and possible variation of the failure mode are discussed in the paper, and recommendations for the capacity design of the façade frame are given. It is found that the additional vertical element does not contribute in the gravity load system; hence, it should not be considered as an intermittent column irregularity. This concept is applied to a 10-story plan-irregular building, with hypothetical location in Lima (Perú), and its seismic performance is assessed. Compared to the original solution, the maximum floor displacement was reduced up to 30%. The dominant period of vibration was reduced up to 15%. The recommended capacity-design condition allowed ductile behaviour without local collapse for demands larger than the MCE., The authors acknowledge support of the Spanish State Research Agency and the European Funds for Regional Development, through the research project RTI2018-097314-BC21., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Experimental bond performance of fibre reinforced polymer prestressed concrete elements

  • Oller Ibars, Eva
  • Ortiz Bernal, Galo Fabian
  • Várzea, Nuno
  • Murcia Delso, Juan
  • Marí Bernat, Antonio Ricardo
In pretensioned prestressed concrete elements, bond between reinforcement and concrete differs is fundamental for a safe design. The so-called Hoyer effect, produced by the lateral expansion of a material when subjected to load, increases the bond resistance, but it also increases the circumferential stresses and then, the risk of cracking due to the tendon expansion. The bond behaviour of FRP tendons has not been studied in depth. To study the bond performance of FRP tendons, and characterize the transfer and flexural development length, an experimental program was carried out. This program was based on a setup called ECADA developed for steel tendons by the Universidad Politécnica de Valencia. The test specimen represents the anchorage area of the tendon and the remaining part of the theoretical beam is substituted by an anchorage measurement access system that has the same rigidity of the replaced part. The test starts by prestressing from one side and after concreting, the prestressed force is released gradually, then the transfer length is measured. Afterwards, the tendon is pulled from the other side, and the total development length is determined iteratively by producing samples of different lengths. The results of the ECADA tests have indicated that the transfer lengths of the FRP tendons being studied lie within 100 and 300 mm., The authors acknowledge the support provided by Spanish Ministry of Science and Innovation (MCIN/AEI) and by the European Funds for Regional Development in the following projects RTI2018-097314-B-C21, and PID2021-123701OB-C21. The authors would like to acknowledge Sireg for their courtesy supplying the different FRP embedded reinforcement used in the experimental programs., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Model code approach to the SLS design of FRP reinforced concrete elements

  • Torres Llinàs, Lluís
  • Guadagnini, Maurizio
  • Barris Peña, Cristina
  • Matthys, Stijn
  • Oller Ibars, Eva
  • Baena Muñoz, Marta
Though research on FRP reinforcement has led to the development of several design recommendations over the past 25 years, recent efforts have focused on the development of unified design procedures and models that can account for the effect of both conventional steel and advanced FRP reinforcement. Examples of such efforts are testament to the level of maturity reached by this novel reinforcing solution and will facilitate a more widespread adoption of FRP reinforcement. The relatively lower modulus of elasticity of FRP materials compared to steel reinforcement may lead to large strains, crack widths and deflections, and as a consequence the design FRP reinforced concrete structures is often governed by serviceability requirements. This paper outlines the principles underlying the recommendations for the serviceability limit state design of FRP reinforced concrete structures included in the next generation of Model Code, discussing merits and limitations as well as comparing to other relevant proposals., Support provided by Spanish Ministry of Science and Innovation (MCIN/ AEI) and by European Funds for Regional Development through projects PID2020‐119015GB‐C22, RTI2018–097314-B-C21 and PID2021-123701OB-C21 is acknowledged., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Mechanical model for the shear strength of steel fibers reinforced concrete beams (SFRC) without stirrups, Modelo mecánico para la resistencia a cortante de vigas de hormigón armado reforzado con fibras, sin armadura de cortante

  • Marí Bernat, Antonio Ricardo
  • Spinella, Nino
  • Recupero, Antonino
  • Cladera Bohigas, Antoni
Despite the numerous studies made showing that the addition of steel fibres to concrete enhances the shear strength of RC beams, current design formulations are still empirical and present large scatter in front of the test results. In this paper, the previously developed Multi-Action Shear Model is extended to SFRC beams without stirrups, adopting an analytical formulation to evaluate the residual tensile stress of SFRC and incorporating the effects of the crack bridging capacity of SFRC in the shear resisted trough the different shear-transfer mechanisms. The proposed model predicts the tests results included in a recently published database with 448 shear tests with less scatter than any of the existing models., The financial support provided by the University of Messina (Italy), through the scholarship granted for a two-months research and teaching stage of the first author, is acknowledged. This work is part of the Research Projects BIA2015-64672-C4-1-R, funded by the Spanish Ministry of Economy and competitiveness, and RTI2018-097314-B-C21, funded by the Spanish Ministry of Science and Innovation., Postprint (published version)