Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Energy deposition around swift proton tracks in polymethylmethacrylate: How much and how far

  • Dapor, Maurizio
  • Abril, Isabel
  • Vera Gomis, Pablo de
  • García Molina, Rafael
  • Abril, Isabel|||/items/cfca10a8-c1ac-4706-a8b7-f2215edb97c3
The use of proton beams in several modern technologies to probe or modify the properties of materials, such as proton beam lithography or ion beam cancer therapy, requires us to accurately know the extent to which the energy lost by the swift projectiles in the medium is redistributed radially around their tracks, since this determines several endpoints, such as the resolution of imaging or manufacturing techniques, or even the biological outcomes of radiotherapy. In this paper, the radial distribution of the energy deposited around swift-proton tracks in polymethylmethacrylate (PMMA) by the transport of secondary electrons is obtained by means of a detailed Monte Carlo simulation. The initial energy and angular distributions of the secondary electrons generated by proton impact, as well as the electronic cross sections for the ejection of these electrons, are reliably calculated in the framework of the dielectric formalism, where a realistic electronic excitation spectrum of PMMA is accounted for. The cascade of all secondary electrons generated in PMMA is simulated taking into account the main interactions that occur between these electrons and the condensed phase target. After analyzing the influence that several angular distributions of the electrons generated by the proton beam have on the resulting radial profiles of deposited energy, we conclude that the widely used Rudd and Kim formula should be replaced by the simpler isotropic angular distribution, which leads to radial energy distributions comparable to the ones obtained from more realistic angular distributions. By studying the dependence of the radial dose on the proton energy we recommend lower proton energies than previously published for reducing proximity effects around a proton track. The obtained results are of relevance for assessing the resolution limits of proton beam based imaging and manufacturing techniques.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Simulation of the secondary electrons energy deposition produced by proton beams in PMMA: influence of the target electronic excitation description

  • Dapor, Maurizio
  • Abril, Isabel
  • Vera Gomis, Pablo de
  • García Molina, Rafael
  • Abril, Isabel|||/items/cfca10a8-c1ac-4706-a8b7-f2215edb97c3
We have studied the radial dependence of the energy deposition of the secondary electron generated by swift proton beams incident with energies T = 50 keV–5 MeV on poly(methylmethacrylate) (PMMA). Two different approaches have been used to model the electronic excitation spectrum of PMMA through its energy loss function (ELF), namely the extended-Drude ELF and the Mermin ELF. The singly differential cross section and the total cross section for ionization, as well as the average energy of the generated secondary electrons, show sizeable differences at T ⩽ 0.1 MeV when evaluated with these two ELF models. In order to know the radial distribution around the proton track of the energy deposited by the cascade of secondary electrons, a simulation has been performed that follows the motion of the electrons through the target taking into account both the inelastic interactions (via electronic ionizations and excitations as well as electron-phonon and electron trapping by polaron creation) and the elastic interactions. The radial distribution of the energy deposited by the secondary electrons around the proton track shows notable differences between the simulations performed with the extended-Drude ELF or the Mermin ELF, being the former more spread out (and, therefore, less peaked) than the latter. The highest intensity and sharpness of the deposited energy distributions takes place for proton beams incident with T ~ 0.1–1 MeV. We have also studied the influence in the radial distribution of deposited energy of using a full energy distribution of secondary electrons generated by proton impact or using a single value (namely, the average value of the distribution); our results show that differences between both simulations become important for proton energies larger than ~0.1 MeV. The results presented in this work have potential applications in materials science, as well as hadron therapy (due to the use of PMMA as a tissue phantom) in order to properly consider the generation of electrons by proton beams and their subsequent transport and energy deposition through the target in nanometric scales.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Lateral spread of dose distribution by therapeutic proton beams in liquid water

  • Abril, Isabel
  • Vera Gomis, Pablo de
  • García Molina, Rafael
  • Kyriakou, Ioanna
  • Emfietzoglou, Dimitris
  • Abril, Isabel|||/items/cfca10a8-c1ac-4706-a8b7-f2215edb97c3
We have calculated the lateral spread of the dose distribution of protons in liquid water by means of the SEICS (Simulation of Energetic Ions and Clusters through Solids) code, which properly accounts for the electronic stopping force (including energy-loss straggling), multiple elastic scattering with the target nuclei, dynamical electron charge-exchange processes and nuclear fragmentation reactions between the projectile and the nuclei of the target. Due to the multiple elastic scattering processes part of the proton energy may be deposited at a given lateral distance from the initial beam direction, which is quantified by the root mean square radius (rrms). We find in our simulations that the rrms follows a parabolic dependence as a function of the depth in the target and the quotient between the rrms at the Bragg peak and the depth of the Bragg peak is around 3% independently of the proton energy. A rather good agreement is obtained when comparing our results of rrms with experimental data and with other models.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Radiobiological Effects Induced by X-ray (LINAC) Irradiation: Experiments and Modelling

  • Traore, A.
  • Ellis-Gibbings, L.
  • Krupa, K.
  • Lozano, Ana I.
  • Colmenares, R.
  • Muñoz, A.
  • Oller, Juan C.
  • Blanco, F.
  • García-Grande, Aránzazu
  • Coronado, M.J.
  • Rosado, S.
  • Rami, E.
  • Núñez, L.
  • Limão-Vieira, P.
  • García, Gustavo
Part of the Bioanalysis book series (BIOANALYSIS, volume 8), In this study we present a modelling procedure that combines the standard electromagnetic physics of Geant4 for photons with the LEPTS event by event Monte Carlo simulation programme for secondary electrons. LEPTS provides detailed information of the energy deposition and the type and number of collision events taking place in a 1 m3 liquid water phantom when irradiated with 6 MV photons generated by a LINAC accelerator. The simulation is compared to a radiobiological experiment determining the biological effects (cell cycle alteration, early apoptosis, DNA damage) induced by the 6 MeV CLINAC radiation to a Jurkat T lymphocyte culture in a water phantom. Notable cell cycle alterations were found between 24 and 48 h after a 2 Gy radiation dose. Early apoptosis and DNA fragmentation has been analysed at 48, 72 and 96 h post irradiation. As expected, the sequence of the apoptotic process has been clear in the irradiated area up to 48 h after radiation. However, substantial apoptotic cells have also been identified outside of this area, in the penumbra and even in the low dose area, where a maximum in the percentage of DNA fragmentation is shown. We attributed this effect to the fact that although the average energy of primary and secondary particles in these areas is lower than those in the irradiated area, their interaction cross sections are much higher, thereby increasing the probability of producing damage., This study has been mainly supported by the EU through the FP7-PEOPLE-2013-ITN programme (project ARGENT-608163). It has also been supported by the Spanish Ministerio de Ciencia, Innovación y Universidades (project FIS2016-80440). We also acknowledge the Hospital Universitario Puerta de Hierro of Madrid for providing the required equipment and services to perform the presented experiments.