Dataset for Thermoporoelastic flow control strategies for enhancing the longevity of hydraulic fracture-based enhanced geothermal systems

  • Tangirala, Sri Kalyan
  • Kivi, Iman Rahimzadeh
  • Vilarrasa, Víctor
ResFrac is a commercial software and requires a license to use it., [Relationship between files, if important] Folders named no_FCDs and with_FCDs contain the models where no FCDs were used and the models where FCDs were used. The no_FCDs folder contains 6 subfolders, each of which have their respective model files. The with_FCDs folder has 3 subfolders where 135kgps and 150kgps, each have 3 of their own subfolders that contain the model files corresponding to when the FCDs were activated during circulation. The pre existing fracture folder in the with_FCDs folder has its model files where FCDs were activated from the beginning of circulation., This dataset includes the input files of the numerical models used in the manuscript for simulating different cases of the hydraulic fracture-based Enhanced Geothermal Systems (EGS). There are two main folders named ‘no_FCDs’ and ‘with_FCDs’ that contain subfolders corresponding to their different circulation flow rates and pre-existing fracture cases. In the no_FCDs folder, there are 6 subfolders where 5 of them are named with their circulation flow rates (90 kgps, 105 kgps, 120 kgps, 135 kgps and 150 kgps) and another subfolder named ‘pre existing fracture’. The folder named with_FCDs has three folders named ‘135 kgps’, ‘150 kgps’ and ‘pre existing fracture’. The 135 kgps folder has subfolders named ‘from start’, ‘from 21 yr’ and ‘from 24 yr’. The 150 kgps folder has subfolders named ‘from start’, ‘from 13 yr’ and ‘from 16 yr’. Within each subfolder, the model is defined by two text files in a ResFrac-specific keyword format. The 'settings' file and the 'input' file together contain the simulation-specific parameters, including material and formation properties, initial and boundary conditions, the mesh definition (matrix region extent and element sizing), the fluid and relative permeability models, and the well controls and treatment schedule. Because the model was built on a rectilinear grid within the user interface, no separate mesh file is generated and the gridding is contained directly within these input files., S.K.T. and V.V. acknowledge funding from the European Research Council (ERC) under the European Union’s Horizon Europe Research and Innovation Program through the Proof of Concept NOSHAKE under Grant agreement No. 101248689. I.R.K. acknowledges funding from MICIU/AEI /10.13039/501100011033 and from the FSE+ through the ‘Ramón y Cajal’ fellowship (reference RYC2024-048711-I). V.V. acknowledges support from the Spanish Ministry of Science, Innovation and Universities through the project HydroPoreII (PID2022-137652NB-C44). IMEDEA is an accredited "Maria de Maeztu Excellence Unit" (Grant CEX2021-001198, funded by MICIU/AEI/10.13039/501100011033)., With funding from the Spanish government through the "Maria de Maeztu Centre of Excellence" accreditation (CEX2021-001198)., File List: README.txt (this file) no_FCDs input_TE_on_90_fln2_noFCDn_45.txt settings_TE_on_90_fln2_noFCDn_45.txt input_TE_on_105_fln2_noFCDn_45.txt settings_TE_on_105_fln2_noFCDn_45.txt input_TE_on_120_fln2_noFCDn_45y.txt settings_TE_on_120_fln2_noFCDn_45y.txt input_TE_on_135_fln2_noFCDn_45y.txt settings_TE_on_135_fln2_noFCDn_45y.txt input_TE_on_150_fln2_noFCDn_45y.txt settings_TE_on_150_fln2_noFCDn_45y.txt input_TE_on_120_fln2_noFCDn_crack1.txt settings_TE_on_120_fln2_noFCDn_crack1.txt with_FCDs input_TE_on_135_fln2_FCDn0p125_45y.txt settings_TE_on_135_fln2_FCDn0p125_45y.txt input_TE_on_135_fln2_21yFCDn45y.txt settings_TE_on_135_fln2_21yFCDn45y.txt input_TE_on_135_fln2_FCDn_24_45.txt settings_TE_on_135_fln2_FCDn_24_45.txt input_TE_on_150_fln2_FCD0p125_45y.txt settings_TE_on_150_fln2_FCD0p125_45y.txt input_TE_on_150_fln2_13yFCDn0p125_45.txt settings_TE_on_150_fln2_13yFCDn0p125_45.txt input_TE_on_150_fln2_FCDn_16_45.txt settings_TE_on_150_fln2_FCDn_16_45.txt input_TE_on_120_fln2_FCDn_crack.txt settings_TE_on_120_fln2_FCDn_crack.txt These models were simulated using a commercial software ResFrac. In order to run the models, a valid license needs to be taken from ResFrac to use their simulator., Peer reviewed