Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 30
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Toward integrated management of cerebral aneurysms

  • Villa-Uriol, Maria-Cruz
  • Larrabide, Ignacio, 1978-
  • Pozo Soler, José Ma. (José María)
  • Kim, Minsuok
  • Camara, Oscar
  • Craene, Mathieu de
  • Zhang, Chong
  • Geers, Arjan
  • Morales, Hernán G.
  • Bogunovic, Hrvoje
  • Cardenes, Rubén
  • Frangi Caregnato, Alejandro
In the last few years, some of the visionary concepts behind the virtual physiological human began to be demonstrated on various clinical domains, showing great promise for improving healthcare management. In the current work, we provide an overview of image- and biomechanics-based techniques that, when put together, provide a patient-specific pipeline for the management of intracranial aneurysms. The derivation and subsequent integration of morphological, morphodynamic, haemodynamic and structural analyses allow us to extract patient-specific models and information from which diagnostic and prognostic descriptors can be obtained. Linking such new indices with relevant clinical events should bring new insights into the processes behind aneurysm genesis, growth and rupture. The development of techniques for modelling endovascular devices such as stents and coils allows the evaluation of alternative treatment scenarios before the intervention takes place and could also contribute to the understanding and improved design of more effective devices. A key element to facilitate the clinical take-up of all these developments is their comprehensive validation. Although a number of previously published results have shown the accuracy and robustness of individual components, further efforts should be directed to demonstrate the diagnostic and prognostic efficacy of these advanced tools through large-scale clinical trials., This work was partially supported by the @neurIST Integrated Project (co-financed by the European Commission through contract no. IST-027703), a CDTI CENIT-CDTEAM grant funded by the Spanish Ministry of Science and Innovation (MICINN-CDTI) and Philips Healthcare (Best, The Netherlands). The authors are also grateful for the support provided by ANSYS Inc. (Canonsburg, PA, USA).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Efficient 3D Geometric and Zernike moments computation from unstructured surface meshes

  • Pozo Soler, José Ma. (José María)
  • Villa-Uriol, Maria-Cruz
  • Frangi Caregnato, Alejandro
This paper introduces and evaluates a fast exact algorithm and a series of faster approximate algorithms for the computation of 3D geometric moments from an unstructured surface mesh of triangles. Being based on the object surface reduces the computational complexity of these algorithms with respect to volumetric grid-based algorithms. In contrast, it can only be applied for the computation of geometric moments of homogeneous objects. This advantage and restriction is shared with other proposed algorithms based on the object boundary. The proposed exact algorithm reduces the computational complexity for computing geometric moments up to order N with respect to previously proposed exact algorithms, from N 9 to N 6 . The approximate series algorithm appears as a power series on the rate between triangle size and object size, which can be truncated at any desired degree. The higher the number and quality of the triangles, the better the approximation. This approximate algorithm reduces the computational complexity to N 3 . In addition, the paper introduces a fast algorithm for the computation of 3D Zernike moments from the computed geometric moments, with a computational complexity N 4 , while the previously proposed algorithm is of order N 6 . The error introduced by the proposed approximate algorithms is evaluated in different shapes and the cost-benefit ratio in terms of error, and computational time is analyzed for different moment orders., This work was partially supported by Philips Healthcare (Best, The Netherlands), the @neurIST Integrated Project (co-financed by the European Commission through the contract no. IST-027703), the CDTI CENIT-CDTEAM grant funded by the Spanish Ministry of Industry and the research project STIMATH (TIN2009-14536-C02-01) funded by the Spanish Ministry of Science and Innovation (MICINN) and the European Regional Development Fund (ERDF)
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

The role of computational fluid dynamics in the management of unruptured intracranial aneurysms: a clinicians' view

  • Singh, Pankai K.
  • Marzo, Alberto
  • Coley, Stuart C.
  • Berti, Guntram
  • Bijlenga, Philippe
  • Lawford, Patricia V.
  • Villa-Uriol, Maria-Cruz
  • Rufenacht, Daniel A.
  • McCormack, Keith M.
  • Frangi Caregnato, Alejandro
  • Patel, Umang J.
  • Hose, D. Rodney
Objective: The importance of hemodynamics in the etiopathogenesis of intracranial aneurysms (IAs) is widely accepted./nComputational fluid dynamics (CFD) is being used increasingly for hemodynamic predictions. However, alogn with the/ncontinuing development and validation of these tools, it is imperative to collect the opinion of the clinicians. Methods: A workshop/non CFD was conducted during the European Society of Minimally Invasive Neurological Therapy (ESMINT) Teaching Course,/nLisbon, Portugal. 36 delegates, mostly clinicians, performed supervised CFD analysis for an IA, using the @neuFuse software/ndeveloped within the European project @neurIST. Feedback on the workshop was collected and analyzed. The performance/nwas assessed on a scale of 1 to 4 and, compared with experts’ performance. Results: Current dilemmas in the management of/nunruptured IAs remained the most important motivating factor to attend the workshop and majority of participants showed/ninterest in participating in a multicentric trial. The participants achieved an average score of 2.52 (range 0–4) which was 63% (range 0–100%) of an expert user. Conclusions: Although participants showed a manifest interest in CFD, there was a clear lack of/nawareness concerning the role of hemodynamics in the etiopathogenesis of IAs and the use of CFD in this context. More efforts/ntherefore are required to enhance understanding of the clinicians in the subject., The authors would like to thank the European Commission,/nVI Framework Program, Priority 2, Information Society/nComputational Intelligence and Neuroscience 11/nTechnologies, a European Public Funded Organization,/nfor funding @neurIST Project (2) (www.aneurist.org) and/nallowing this study (Research Grant no. IST-FP6-027703). The funding was provided in the form of financial support/nto first two authors along with the arrangement of necessary/nresources to conduct the workshop.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Deployment of self-expandable stents in aneurysmatic cerebral vessels: comparison of different computational approaches for interventional planning

  • Bernardini, A.
  • Larrabide, Ignacio, 1978-
  • Petrini, L.
  • Pennati, G.
  • Flore, Eleonora
  • Kim, Minsuok
  • Frangi Caregnato, Alejandro
In the last few years, there has been a growing focus on faster computational methods to support clinicians in planning stenting procedures. This study investigates the possibility of introducing computational approximations in modelling stent deployment in aneurysmatic cerebral vessels to achieve simulations compatible with the constraints of real clinical workflows. The release of a self-expandable stent in a simplified aneurysmatic vessel was modelled in four different initial positions. Six progressively simplified modelling approaches (based on Finite Element method and Fast Virtual Stenting – FVS) have been used. Comparing accuracy of the results, the final configuration of the stent is more affected by neglecting mechanical properties of materials (FVS) than by adopting 1D instead of 3D stent models. Nevertheless, the differences/nshowed are acceptable compared to those achieved by considering different stent initial positions. Regarding computational/ncosts, simulations involving 1D stent features are the only ones feasible in clinical context., This work was partially supported within the CENIT CDTEAM (2006–2009) and cvREMOD (2010–2012) projects funded by the Spanish MICINN-CDTI, and partly within the framework of the @neurIST Integrated Project (IST-2005-027703), which is cofinanced by the European Commission within the IST Program of Sixth Framework Program.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape

  • Larrabide, Ignacio, 1978-
  • Aguilar, María Laura
  • Morales, Hernán G.
  • Geers, Adrianus Johannes
  • Kulcsár, Zsolt
  • Rüfenacht, Daniel
  • Frangi Caregnato, Alejandro
Background and purpose: Effects of blood flow modification by flow diverters are observed to lead often to aneurysm thrombosis and reverse remodeling. For this process, to further understand the potential roles of intra-aneurysmal blood pressure changes and aneurysm morphologies, 23 patients were studied by numeric simulation. Materials and methods: 3D imaging of aneurysms of different sizes and shapes, all located at the supraclinoid segment of the ICA (n = 23), was prepared for CFD simulations. Hemodynamic variables were calculated for conditions before and after virtual FD implantation, reconstituting a vessel wall scaffold across the aneurysm neck. WSS, velocity, residence time, turnover time, and intra-aneurysmal pressure were assessed statistically. Results: After placement of FDs, significant reductions inside the aneurysm were observed for most hemodynamic variables (P < .01) except mean intra-aneurysmal pressures. For minimum/maximum intra-aneurysmal pressure values, small but significant changes were found; however, they were considered too small to be of relevance. Conclusions: Calculations in 23 cases did not reveal significant intra-aneurysmal mean or peak pressure changes, indicating a minor role of pressure changes in the rare event of secondary ruptures after FD use. Other hemodynamic variables (WSS and velocity) exhibited more significant changes, indicating their role in intra-aneurysmal thrombus formation. Size-dependent, significantly higher reduction in WSS (P = .069) and velocity (P = .013) was observed in small aneurysms compared with larger ones. When it came to shape, there were significantly higher reductions in WSS (P = .055) and velocity (P = .065) and a significantly higher increase in turnover time in fusiform aneurysms compared with saccular aneurysms., This research has been partially funded by the Industrial and Technological Development Center (CDTI) under the CENIT-CDTEAM and CENIT-cvREMOD programs, the European Commission project @neurIST (IST-2005-027703), and Philips Healthcare.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Morphodynamic analysis of cerebral aneurysm pulsation from time-resolved rotational angiography

  • Zhang, Chong
  • Villa-Uriol, Maria-Cruz
  • Craene, Mathieu de
  • Pozo Soler, José Ma. (José María)
  • Frangi Caregnato, Alejandro
This paper presents a technique to estimate and model patient-specific pulsatility of cerebral aneurysms over one/ncardiac cycle, using 3D rotational X-ray angiography (3DRA) acquisitions. Aneurysm pulsation is modeled as a time varying/n-spline tensor field representing the deformation applied to a reference volume image, thus producing the instantaneous/nmorphology at each time point in the cardiac cycle. The estimated deformation is obtained by matching multiple simulated projections of the deforming volume to their corresponding original projections. A weighting scheme is introduced to account for the relevance of each original projection for the selected time point. The wide coverage of the projections, together with the weighting scheme, ensures motion consistency in all directions. The technique has been tested on digital and physical phantoms that are realistic and clinically relevant in terms of geometry, pulsation and imaging conditions. Results from digital phantom/nexperiments demonstrate that the proposed technique is able to recover subvoxel pulsation with an error lower than 10% of the maximum pulsation in most cases. The experiments with the physical phantom allowed demonstrating the feasibility of pulsation estimation as well as identifying different pulsation regions under clinical conditions., This work was supported in part by Philips Healthcare, Best, The Netherlands, in part by/nthe CENIT-CDTEAM grant funded by the Spanish Ministry Of Science and Innovation (MICINN-CDTI), and partially generated in the framework of the/n@neurIST Integrated Project, which is co-financed by the European Commission (IST-027703).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Patient-specific computational hemodynamics of intracranial aneurysms from 3D rotational angiography and CT angiography: an in vivo reproducibility study

  • Geers, Arjan
  • Larrabide, Ignacio, 1978-
  • Radaelli, Alessandro Guido
  • Bogunovic, Hrvoje
  • Kim, Minsuok
  • Gratama van Andel, Hugo A. F.
  • Majoie, Charles B. L. M.
  • VanBavel, E
  • Frangi Caregnato, Alejandro
Patient-specific simulations of the hemodynamics in intracranial aneurysms can be constructed by using image-based vascular models and CFD techniques. This work evaluates the impact of the choice of imaging technique on these simulations, This work was partially supported by the @neurIST Integrated Project (cofinanced by the European Commission through contract no. IST-027703) and the CD-TEAM grant funded by the Spanish Ministry of Science and Innovation. Support from Philips Healthcare B.V. and ANSYS Europe Ltd is also acknowledged.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Estimation of the viscoelastic properties of vessel walls using a computational model and Doppler ultrasound

  • Balocco, Simone
  • Basset, Olivier
  • Courbebaisse, Guy
  • Boni, Enrico
  • Frangi Caregnato, Alejandro
  • Tortoli, Piero
  • Cachard, Christian
Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%., This work has been partially funded by the Industrial and Technological Development Centre (CDTI) within the CENIT Programme (CDTEAM Project), the EC @neurIST (IST-FP6-2004-027703) projects, by BQR INSA-Lyon and by the Italian/nMinistry of University & Research (COFIN-PRIN 2005).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Wall motion estimation in intracranial aneurysms

  • Oubel, E.
  • Cebral, J.R.
  • Craene, Mathieu de
  • Blanc, R.
  • Blasco, Jordi
  • Macho, Juan M.
  • Putman, C.M.
  • Frangi Caregnato, Alejandro
The quantification of wall motion in cerebral aneurysms is becoming important owing to its potential connection to rupture, and as a way to incorporate the effects of vascular compliance in computational fluid dynamics (CFD) simulations./nMost of papers report values obtained with experimental phantoms, simulated images, or animal models, but the information for real patients is limited. In this paper, we have combined non-rigid registration (IR) with signal processing techniques to measure pulsation in real patients from high frame rate digital subtraction angiography (DSA). We have obtained physiological meaningful waveforms with amplitudes in the/nrange 0mm-0.3mm for a population of 18 patients including ruptured and unruptured aneurysms. Statistically significant differences in pulsation were found according to the rupture status, in agreement with differences in biomechanical properties reported in the literature.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

@neurIST infrastructure for advanced disease management through integration of heterogeneous data, computing, and complex processing services

  • Benkner, Siegfried
  • Arbona, Antonio
  • Berti, Guntram
  • Chiarini, Alessandro
  • Dunlop, Robert
  • Engelbrecht, Gerhard
  • Frangi Caregnato, Alejandro
  • Friedrich, Christoph M.
  • Hanser, Susanne
  • Hasselmeyer, Peer
  • Hose, D. Rodney
  • Iavindrasana, Jimison
  • Köhler, Martin
  • Lo Iacono, Luigi
  • Lonsdale, Guy
  • Meyer, Rodolphe
  • Moore, Bob
  • Rajasekaran, Hariharan
  • Summers, Paul E.
  • Wöhrer, Alexander
  • Wood, Steven
The increasing volume of data describing human/ndisease processes and the growing complexity of understanding, managing, and sharing such data presents a huge challenge for clinicians and medical researchers. This paper presents the/n@neurIST system, which provides an infrastructure for biomedical research while aiding clinical care, by bringing together heterogeneous data and complex processing and computing services. Although @neurIST targets the investigation and treatment of cerebral aneurysms, the system’s architecture is generic enough that it could be adapted to the treatment of other diseases./nInnovations in @neurIST include confining the patient data pertaining to aneurysms inside a single environment that offers clinicians/nthe tools to analyze and interpret patient data and make use of knowledge-based guidance in planning their treatment. Medical/nresearchers gain access to a critical mass of aneurysm related data due to the system’s ability to federate distributed information/nsources. A semantically mediated grid infrastructure ensures that both clinicians and researchers are able to seamlessly access and/nwork on data that is distributed across multiple sites in a secure way in addition to providing computing resources on demand for/nperforming computationally intensive simulations for treatment planning and research., This work was supported by the framework of the @neurIST Integrated Project, which is cofinanced by the European Commission under Contract IST-027703.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Dynamic estimation of three-dimensional cerebrovascular deformation from rotational angiography

  • Zhang, Chong
  • Villa-Uriol, Maria-Cruz
  • Craene, Mathieu de
  • Pozo Soler, José Ma. (José María)
  • Macho, Juan M.
  • Frangi Caregnato, Alejandro
  • Universitat Pompeu Fabra
Purpose: The objective of this study is to investigate the feasibility of detecting and quantifying 3D cerebrovascular wall motion from a single 3D rotational x-ray angiography (3DRA) acquisition within a clinically acceptable time and computing from the estimated motion field for the further biomechanical modeling of the cerebrovascular wall. Methods: The whole motion cycle of the cerebral vasculature is modeled using a 4D B-spline transformation, which is estimated from a 4D to 2D + t image registration framework. The registration is performed by optimizing a single similarity metric between the entire 2D + t measured projection sequence and the corresponding forward projections of the deformed volume at their exact time instants. The joint use of two acceleration strategies, together with their implementation on graphics processing units, is also proposed so as to reach computation times close to clinical requirements. For further characterizing vessel wall properties, an approximation of the wall thickness changes is obtained through a strain calculation. Results: Evaluation on in silico and in vitro pulsating phantom aneurysms demonstrated an accurate estimation of wall motion curves. In general, the error was below 10% of the maximum pulsation, even in the situation when substantial inhomogeneous intensity pattern was present. Experiments on in vivo data provided realistic aneurysm and vessel wall motion estimates, whereas in regions where motion was neither visible nor anatomically possible, no motion was detected. The use of the acceleration strategies enabled completing the estimation process for one entire cycle in 5-10 min without degrading the overall performance. The strain map extracted from our motion estimation provided a realistic deformation measure of the vessel wall. Conclusions: The authors' technique has demonstrated that it can provide accurate and robust 4D estimates of cerebrovascular wall motion within a clinically acceptable time, although it has to be applied to a larger patient population prior to possible wide application to routine endovascular procedures. In particular, for the first time, this feasibility study has shown that in vivo cerebrovascular motion can be obtained intraprocedurally from a 3DRA acquisition. Results have also shown the potential of performing strain analysis using this imaging modality, thus making possible for the future modeling of biomechanical properties of the vascular wall., This work was partially supported by the CENIT-CDTEAM grant funded by the Spanish Ministry of Science and Innovation, partially generated in the framework of the @neurIST Integrated Project, which is cofinanced by the European Commission (Grant No. IST-027703), and partially supported by the Spanish Ministry of Science and Innovation (Ref. No. TIN2009-14536-C02-01), Plan E, and FEDER.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Automated Segmentation of Cerebral Vasculature with Aneurysms in 3DRA and TOF-MRA using Geodesic Active Regions: an Evaluation Study

  • Bogunovic, Hrvoje
  • Pozo Soler, José Ma. (José María)
  • Villa-Uriol, Maria-Cruz
  • Majoie, Charles B. L. M.
  • van den Berg, Rene
  • Gratama van Andel, Hugo A. F.
  • Macho, Juan M.
  • Blasco, Jordi
  • San Román, Luis
  • Frangi Caregnato, Alejandro
Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D X-ray reconstruc-/ntion angiography (3DRA) and time of °ight magnetic resonance angiography (TOF-MRA) images available in the clinical routine./nMethods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using di®erent imaging equipment. Evaluation included qualitative and quantitative analyses of/nthe segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: iso-intensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an inter-modality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE di®ered from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE, respectively) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatability/nof GAR was superior to manual measurements and ISE. The inter-modality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine., The authors would like to acknowledge J. Schneiders for providing part of the TOF-MRA imaging data. The authors would like to thank also A. G. Radaelli, M. Nieber, and X. Planes for the help in implementing some of the methods. This work was partially supported by the @neurIST Integrated Project (co-financed by the European Commission through Contract No. IST-027703), the CDTI CENIT-CDTEAM grant funded by the Spanish Ministry of Science and Innovation (MICINN-CDTI), the AGAUR-FI fellowship from Generalitat de Catalunya, and Philips Healthcare (Best, The Netherlands).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

How do coil configuration and packing density influence intra-aneurysmal hemodynamics?

  • Morales, Hernán G.
  • Kim, Minsuok
  • Vivas, EE
  • Villa-Uriol, Maria-Cruz
  • Larrabide, Ignacio, 1978-
  • Sola, T
  • Guimaraens, Leopoldo
  • Frangi Caregnato, Alejandro
Endovascular coiling is a well-established therapy for treating intracranial aneurysms. Nonetheless, postoperative hemodynamic changes induced by this therapy remain not fully understood. The purpose of this work is to assess the influence of coil configuration and packing density on intra-aneurysmal hemodynamics, This work was partially supported within the CENIT program, as part of CDTEAM and cvREMOD projects funded by the Spanish CDTI and partly within the framework of the @neurIST Project (IST-2005-027703), which is cofinanced by the European Commission within the IST Program of the Sixth Framework Program
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Pathway databases and tools for their exploitation: benefits, current limitations and challenges

  • Bauer-Mehren, Anna
  • Furlong, Laura I., 1971-
  • Sanz, Ferran
In past years, comprehensive representations of cell signalling pathways have been developed by manual curation from literature, which requires huge effort and would benefit from information stored in databases and from automatic retrieval and integration methods. Once a reconstruction of the network of interactions is achieved, analysis of its structural features and its dynamic behaviour can take place. Mathematical modelling techniques are used to simulate the complex behaviour of cell signalling networks, which ultimately sheds light on the mechanisms leading to complex diseases or helps in the identification of drug targets. A variety of databases containing information on cell signalling pathways have been developed in conjunction with methodologies to access and analyse the data. In principle, the scenario is prepared to make the most of this information for the analysis of the dynamics of signalling pathways. However, are the knowledge repositories of signalling pathways ready to realize the systems biology promise? In this article we aim to initiate this discussion and to provide some insights on this issue., This work was generated in the framework of the @neurIST and the/nEU-ADR projects co-financed by the European Commission through/nthe contracts no. IST-027703 and ICT-215847, respectively.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Three-dimensional morphological analysis of intracranial aneurysms: a fully automated method for aneurysm sac isolation and quantification

  • Larrabide, Ignacio, 1978-
  • Villa-Uriol, Maria-Cruz
  • Cardenes, Rubén
  • Pozo Soler, José Ma. (José María)
  • Macho, Juan M.
  • San Román, Luis
  • Blasco, Jordi
  • Vivas, Elio
  • Marzo, Alberto
  • Hose, D. Rodney
  • Frangi Caregnato, Alejandro
Morphological descriptors are practical and essential biomarkers for diagnosis and/ntreatment selection for intracranial aneurysm management according to the current guidelines/nin use. Nevertheless, relatively little work has been dedicated to improve the three-dimensional/nquanti cation of aneurysmal morphology, automate the analysis, and hence reduce the inherent/nintra- and inter-observer variability of manual analysis. In this paper we propose a methodology/nfor the automated isolation and morphological quanti cation of saccular intracranial aneurysms/nbased on a 3D representation of the vascular anatomy., This work was partially supported within the CENIT-CDTEAM and CENIT cvREMOD projects funded by the Spanish Ministry of Innovation and Science-CDTI and partly within the framework of the @neurIST Project (IST-2005-027703), which is co- nanced by the European Commission within the IST Program of the Sixth Framework Programm.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Toward integrated management of cerebral aneurysms

  • Villa-Uriol, Maria-Cruz
  • Larrabide, Ignacio, 1978-
  • Pozo Soler, José Ma. (José María)
  • Kim, Minsuok
  • Camara, Oscar
  • Craene, Mathieu de
  • Zhang, Chong
  • Geers, Arjan
  • Morales, Hernán G.
  • Bogunovic, Hrvoje
  • Cardenes, Rubén
  • Frangi Caregnato, Alejandro
In the last few years, some of the visionary concepts behind the virtual physiological human began to be demonstrated on various clinical domains, showing great promise for improving healthcare management. In the current work, we provide an overview of image- and biomechanics-based techniques that, when put together, provide a patient-specific pipeline for the management of intracranial aneurysms. The derivation and subsequent integration of morphological, morphodynamic, haemodynamic and structural analyses allow us to extract patient-specific models and information from which diagnostic and prognostic descriptors can be obtained. Linking such new indices with relevant clinical events should bring new insights into the processes behind aneurysm genesis, growth and rupture. The development of techniques for modelling endovascular devices such as stents and coils allows the evaluation of alternative treatment scenarios before the intervention takes place and could also contribute to the understanding and improved design of more effective devices. A key element to facilitate the clinical take-up of all these developments is their comprehensive validation. Although a number of previously published results have shown the accuracy and robustness of individual components, further efforts should be directed to demonstrate the diagnostic and prognostic efficacy of these advanced tools through large-scale clinical trials., This work was partially supported by the @neurIST Integrated Project (co-financed by the European Commission through contract no. IST-027703), a CDTI CENIT-CDTEAM grant funded by the Spanish Ministry of Science and Innovation (MICINN-CDTI) and Philips Healthcare (Best, The Netherlands). The authors are also grateful for the support provided by ANSYS Inc. (Canonsburg, PA, USA).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Deployment of self-expandable stents in aneurysmatic cerebral vessels: comparison of different computational approaches for interventional planning

  • Bernardini, A.
  • Larrabide, Ignacio, 1978-
  • Petrini, L.
  • Pennati, G.
  • Flore, Eleonora
  • Kim, Minsuok
  • Frangi Caregnato, Alejandro
In the last few years, there has been a growing focus on faster computational methods to support clinicians in planning stenting procedures. This study investigates the possibility of introducing computational approximations in modelling stent deployment in aneurysmatic cerebral vessels to achieve simulations compatible with the constraints of real clinical workflows. The release of a self-expandable stent in a simplified aneurysmatic vessel was modelled in four different initial positions. Six progressively simplified modelling approaches (based on Finite Element method and Fast Virtual Stenting – FVS) have been used. Comparing accuracy of the results, the final configuration of the stent is more affected by neglecting mechanical properties of materials (FVS) than by adopting 1D instead of 3D stent models. Nevertheless, the differences/nshowed are acceptable compared to those achieved by considering different stent initial positions. Regarding computational/ncosts, simulations involving 1D stent features are the only ones feasible in clinical context., This work was partially supported within the CENIT CDTEAM (2006–2009) and cvREMOD (2010–2012) projects funded by the Spanish MICINN-CDTI, and partly within the framework of the @neurIST Integrated Project (IST-2005-027703), which is cofinanced by the European Commission within the IST Program of Sixth Framework Program.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Dynamic estimation of three-dimensional cerebrovascular deformation from rotational angiography

  • Zhang, Chong
  • Villa-Uriol, Maria-Cruz
  • Craene, Mathieu de
  • Pozo Soler, José Ma. (José María)
  • Macho, Juan M.
  • Frangi Caregnato, Alejandro
  • Universitat Pompeu Fabra
Purpose: The objective of this study is to investigate the feasibility of detecting and quantifying 3D cerebrovascular wall motion from a single 3D rotational x-ray angiography (3DRA) acquisition within a clinically acceptable time and computing from the estimated motion field for the further biomechanical modeling of the cerebrovascular wall. Methods: The whole motion cycle of the cerebral vasculature is modeled using a 4D B-spline transformation, which is estimated from a 4D to 2D + t image registration framework. The registration is performed by optimizing a single similarity metric between the entire 2D + t measured projection sequence and the corresponding forward projections of the deformed volume at their exact time instants. The joint use of two acceleration strategies, together with their implementation on graphics processing units, is also proposed so as to reach computation times close to clinical requirements. For further characterizing vessel wall properties, an approximation of the wall thickness changes is obtained through a strain calculation. Results: Evaluation on in silico and in vitro pulsating phantom aneurysms demonstrated an accurate estimation of wall motion curves. In general, the error was below 10% of the maximum pulsation, even in the situation when substantial inhomogeneous intensity pattern was present. Experiments on in vivo data provided realistic aneurysm and vessel wall motion estimates, whereas in regions where motion was neither visible nor anatomically possible, no motion was detected. The use of the acceleration strategies enabled completing the estimation process for one entire cycle in 5-10 min without degrading the overall performance. The strain map extracted from our motion estimation provided a realistic deformation measure of the vessel wall. Conclusions: The authors' technique has demonstrated that it can provide accurate and robust 4D estimates of cerebrovascular wall motion within a clinically acceptable time, although it has to be applied to a larger patient population prior to possible wide application to routine endovascular procedures. In particular, for the first time, this feasibility study has shown that in vivo cerebrovascular motion can be obtained intraprocedurally from a 3DRA acquisition. Results have also shown the potential of performing strain analysis using this imaging modality, thus making possible for the future modeling of biomechanical properties of the vascular wall., This work was partially supported by the CENIT-CDTEAM grant funded by the Spanish Ministry of Science and Innovation, partially generated in the framework of the @neurIST Integrated Project, which is cofinanced by the European Commission (Grant No. IST-027703), and partially supported by the Spanish Ministry of Science and Innovation (Ref. No. TIN2009-14536-C02-01), Plan E, and FEDER.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

The role of computational fluid dynamics in the management of unruptured intracranial aneurysms: a clinicians' view

  • Singh, Pankai K.
  • Marzo, Alberto
  • Coley, Stuart C.
  • Berti, Guntram
  • Bijlenga, Philippe
  • Lawford, Patricia V.
  • Villa-Uriol, Maria-Cruz
  • Rufenacht, Daniel A.
  • McCormack, Keith M.
  • Frangi Caregnato, Alejandro
  • Patel, Umang J.
  • Hose, D. Rodney
Objective: The importance of hemodynamics in the etiopathogenesis of intracranial aneurysms (IAs) is widely accepted./nComputational fluid dynamics (CFD) is being used increasingly for hemodynamic predictions. However, alogn with the/ncontinuing development and validation of these tools, it is imperative to collect the opinion of the clinicians. Methods: A workshop/non CFD was conducted during the European Society of Minimally Invasive Neurological Therapy (ESMINT) Teaching Course,/nLisbon, Portugal. 36 delegates, mostly clinicians, performed supervised CFD analysis for an IA, using the @neuFuse software/ndeveloped within the European project @neurIST. Feedback on the workshop was collected and analyzed. The performance/nwas assessed on a scale of 1 to 4 and, compared with experts’ performance. Results: Current dilemmas in the management of/nunruptured IAs remained the most important motivating factor to attend the workshop and majority of participants showed/ninterest in participating in a multicentric trial. The participants achieved an average score of 2.52 (range 0–4) which was 63% (range 0–100%) of an expert user. Conclusions: Although participants showed a manifest interest in CFD, there was a clear lack of/nawareness concerning the role of hemodynamics in the etiopathogenesis of IAs and the use of CFD in this context. More efforts/ntherefore are required to enhance understanding of the clinicians in the subject., The authors would like to thank the European Commission,/nVI Framework Program, Priority 2, Information Society/nComputational Intelligence and Neuroscience 11/nTechnologies, a European Public Funded Organization,/nfor funding @neurIST Project (2) (www.aneurist.org) and/nallowing this study (Research Grant no. IST-FP6-027703). The funding was provided in the form of financial support/nto first two authors along with the arrangement of necessary/nresources to conduct the workshop.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Three-dimensional morphological analysis of intracranial aneurysms: a fully automated method for aneurysm sac isolation and quantification

  • Larrabide, Ignacio, 1978-
  • Villa-Uriol, Maria-Cruz
  • Cardenes, Rubén
  • Pozo Soler, José Ma. (José María)
  • Macho, Juan M.
  • San Román, Luis
  • Blasco, Jordi
  • Vivas, Elio
  • Marzo, Alberto
  • Hose, D. Rodney
  • Frangi Caregnato, Alejandro
Morphological descriptors are practical and essential biomarkers for diagnosis and/ntreatment selection for intracranial aneurysm management according to the current guidelines/nin use. Nevertheless, relatively little work has been dedicated to improve the three-dimensional/nquanti cation of aneurysmal morphology, automate the analysis, and hence reduce the inherent/nintra- and inter-observer variability of manual analysis. In this paper we propose a methodology/nfor the automated isolation and morphological quanti cation of saccular intracranial aneurysms/nbased on a 3D representation of the vascular anatomy., This work was partially supported within the CENIT-CDTEAM and CENIT cvREMOD projects funded by the Spanish Ministry of Innovation and Science-CDTI and partly within the framework of the @neurIST Project (IST-2005-027703), which is co- nanced by the European Commission within the IST Program of the Sixth Framework Programm.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape

  • Larrabide, Ignacio, 1978-
  • Aguilar, María Laura
  • Morales, Hernán G.
  • Geers, Adrianus Johannes
  • Kulcsár, Zsolt
  • Rüfenacht, Daniel
  • Frangi Caregnato, Alejandro
Background and purpose: Effects of blood flow modification by flow diverters are observed to lead often to aneurysm thrombosis and reverse remodeling. For this process, to further understand the potential roles of intra-aneurysmal blood pressure changes and aneurysm morphologies, 23 patients were studied by numeric simulation. Materials and methods: 3D imaging of aneurysms of different sizes and shapes, all located at the supraclinoid segment of the ICA (n = 23), was prepared for CFD simulations. Hemodynamic variables were calculated for conditions before and after virtual FD implantation, reconstituting a vessel wall scaffold across the aneurysm neck. WSS, velocity, residence time, turnover time, and intra-aneurysmal pressure were assessed statistically. Results: After placement of FDs, significant reductions inside the aneurysm were observed for most hemodynamic variables (P < .01) except mean intra-aneurysmal pressures. For minimum/maximum intra-aneurysmal pressure values, small but significant changes were found; however, they were considered too small to be of relevance. Conclusions: Calculations in 23 cases did not reveal significant intra-aneurysmal mean or peak pressure changes, indicating a minor role of pressure changes in the rare event of secondary ruptures after FD use. Other hemodynamic variables (WSS and velocity) exhibited more significant changes, indicating their role in intra-aneurysmal thrombus formation. Size-dependent, significantly higher reduction in WSS (P = .069) and velocity (P = .013) was observed in small aneurysms compared with larger ones. When it came to shape, there were significantly higher reductions in WSS (P = .055) and velocity (P = .065) and a significantly higher increase in turnover time in fusiform aneurysms compared with saccular aneurysms., This research has been partially funded by the Industrial and Technological Development Center (CDTI) under the CENIT-CDTEAM and CENIT-cvREMOD programs, the European Commission project @neurIST (IST-2005-027703), and Philips Healthcare.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Morphodynamic analysis of cerebral aneurysm pulsation from time-resolved rotational angiography

  • Zhang, Chong
  • Villa-Uriol, Maria-Cruz
  • Craene, Mathieu de
  • Pozo Soler, José Ma. (José María)
  • Frangi Caregnato, Alejandro
This paper presents a technique to estimate and model patient-specific pulsatility of cerebral aneurysms over one/ncardiac cycle, using 3D rotational X-ray angiography (3DRA) acquisitions. Aneurysm pulsation is modeled as a time varying/n-spline tensor field representing the deformation applied to a reference volume image, thus producing the instantaneous/nmorphology at each time point in the cardiac cycle. The estimated deformation is obtained by matching multiple simulated projections of the deforming volume to their corresponding original projections. A weighting scheme is introduced to account for the relevance of each original projection for the selected time point. The wide coverage of the projections, together with the weighting scheme, ensures motion consistency in all directions. The technique has been tested on digital and physical phantoms that are realistic and clinically relevant in terms of geometry, pulsation and imaging conditions. Results from digital phantom/nexperiments demonstrate that the proposed technique is able to recover subvoxel pulsation with an error lower than 10% of the maximum pulsation in most cases. The experiments with the physical phantom allowed demonstrating the feasibility of pulsation estimation as well as identifying different pulsation regions under clinical conditions., This work was supported in part by Philips Healthcare, Best, The Netherlands, in part by/nthe CENIT-CDTEAM grant funded by the Spanish Ministry Of Science and Innovation (MICINN-CDTI), and partially generated in the framework of the/n@neurIST Integrated Project, which is co-financed by the European Commission (IST-027703).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Estimation of the viscoelastic properties of vessel walls using a computational model and Doppler ultrasound

  • Balocco, Simone
  • Basset, Olivier
  • Courbebaisse, Guy
  • Boni, Enrico
  • Frangi Caregnato, Alejandro
  • Tortoli, Piero
  • Cachard, Christian
Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%., This work has been partially funded by the Industrial and Technological Development Centre (CDTI) within the CENIT Programme (CDTEAM Project), the EC @neurIST (IST-FP6-2004-027703) projects, by BQR INSA-Lyon and by the Italian/nMinistry of University & Research (COFIN-PRIN 2005).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Automated Segmentation of Cerebral Vasculature with Aneurysms in 3DRA and TOF-MRA using Geodesic Active Regions: an Evaluation Study

  • Bogunovic, Hrvoje
  • Pozo Soler, José Ma. (José María)
  • Villa-Uriol, Maria-Cruz
  • Majoie, Charles B. L. M.
  • van den Berg, Rene
  • Gratama van Andel, Hugo A. F.
  • Macho, Juan M.
  • Blasco, Jordi
  • San Román, Luis
  • Frangi Caregnato, Alejandro
Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D X-ray reconstruc-/ntion angiography (3DRA) and time of °ight magnetic resonance angiography (TOF-MRA) images available in the clinical routine./nMethods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using di®erent imaging equipment. Evaluation included qualitative and quantitative analyses of/nthe segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: iso-intensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an inter-modality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE di®ered from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE, respectively) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatability/nof GAR was superior to manual measurements and ISE. The inter-modality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine., The authors would like to acknowledge J. Schneiders for providing part of the TOF-MRA imaging data. The authors would like to thank also A. G. Radaelli, M. Nieber, and X. Planes for the help in implementing some of the methods. This work was partially supported by the @neurIST Integrated Project (co-financed by the European Commission through Contract No. IST-027703), the CDTI CENIT-CDTEAM grant funded by the Spanish Ministry of Science and Innovation (MICINN-CDTI), the AGAUR-FI fellowship from Generalitat de Catalunya, and Philips Healthcare (Best, The Netherlands).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Pathway databases and tools for their exploitation: benefits, current limitations and challenges

  • Bauer-Mehren, Anna
  • Furlong, Laura I., 1971-
  • Sanz, Ferran
In past years, comprehensive representations of cell signalling pathways have been developed by manual curation from literature, which requires huge effort and would benefit from information stored in databases and from automatic retrieval and integration methods. Once a reconstruction of the network of interactions is achieved, analysis of its structural features and its dynamic behaviour can take place. Mathematical modelling techniques are used to simulate the complex behaviour of cell signalling networks, which ultimately sheds light on the mechanisms leading to complex diseases or helps in the identification of drug targets. A variety of databases containing information on cell signalling pathways have been developed in conjunction with methodologies to access and analyse the data. In principle, the scenario is prepared to make the most of this information for the analysis of the dynamics of signalling pathways. However, are the knowledge repositories of signalling pathways ready to realize the systems biology promise? In this article we aim to initiate this discussion and to provide some insights on this issue., This work was generated in the framework of the @neurIST and the/nEU-ADR projects co-financed by the European Commission through/nthe contracts no. IST-027703 and ICT-215847, respectively.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

@neurIST infrastructure for advanced disease management through integration of heterogeneous data, computing, and complex processing services

  • Benkner, Siegfried
  • Arbona, Antonio
  • Berti, Guntram
  • Chiarini, Alessandro
  • Dunlop, Robert
  • Engelbrecht, Gerhard
  • Frangi Caregnato, Alejandro
  • Friedrich, Christoph M.
  • Hanser, Susanne
  • Hasselmeyer, Peer
  • Hose, D. Rodney
  • Iavindrasana, Jimison
  • Köhler, Martin
  • Lo Iacono, Luigi
  • Lonsdale, Guy
  • Meyer, Rodolphe
  • Moore, Bob
  • Rajasekaran, Hariharan
  • Summers, Paul E.
  • Wöhrer, Alexander
  • Wood, Steven
The increasing volume of data describing human/ndisease processes and the growing complexity of understanding, managing, and sharing such data presents a huge challenge for clinicians and medical researchers. This paper presents the/n@neurIST system, which provides an infrastructure for biomedical research while aiding clinical care, by bringing together heterogeneous data and complex processing and computing services. Although @neurIST targets the investigation and treatment of cerebral aneurysms, the system’s architecture is generic enough that it could be adapted to the treatment of other diseases./nInnovations in @neurIST include confining the patient data pertaining to aneurysms inside a single environment that offers clinicians/nthe tools to analyze and interpret patient data and make use of knowledge-based guidance in planning their treatment. Medical/nresearchers gain access to a critical mass of aneurysm related data due to the system’s ability to federate distributed information/nsources. A semantically mediated grid infrastructure ensures that both clinicians and researchers are able to seamlessly access and/nwork on data that is distributed across multiple sites in a secure way in addition to providing computing resources on demand for/nperforming computationally intensive simulations for treatment planning and research., This work was supported by the framework of the @neurIST Integrated Project, which is cofinanced by the European Commission under Contract IST-027703.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

How do coil configuration and packing density influence intra-aneurysmal hemodynamics?

  • Morales, Hernán G.
  • Kim, Minsuok
  • Vivas, EE
  • Villa-Uriol, Maria-Cruz
  • Larrabide, Ignacio, 1978-
  • Sola, T
  • Guimaraens, Leopoldo
  • Frangi Caregnato, Alejandro
Endovascular coiling is a well-established therapy for treating intracranial aneurysms. Nonetheless, postoperative hemodynamic changes induced by this therapy remain not fully understood. The purpose of this work is to assess the influence of coil configuration and packing density on intra-aneurysmal hemodynamics, This work was partially supported within the CENIT program, as part of CDTEAM and cvREMOD projects funded by the Spanish CDTI and partly within the framework of the @neurIST Project (IST-2005-027703), which is cofinanced by the European Commission within the IST Program of the Sixth Framework Program
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Efficient 3D Geometric and Zernike moments computation from unstructured surface meshes

  • Pozo Soler, José Ma. (José María)
  • Villa-Uriol, Maria-Cruz
  • Frangi Caregnato, Alejandro
This paper introduces and evaluates a fast exact algorithm and a series of faster approximate algorithms for the computation of 3D geometric moments from an unstructured surface mesh of triangles. Being based on the object surface reduces the computational complexity of these algorithms with respect to volumetric grid-based algorithms. In contrast, it can only be applied for the computation of geometric moments of homogeneous objects. This advantage and restriction is shared with other proposed algorithms based on the object boundary. The proposed exact algorithm reduces the computational complexity for computing geometric moments up to order N with respect to previously proposed exact algorithms, from N 9 to N 6 . The approximate series algorithm appears as a power series on the rate between triangle size and object size, which can be truncated at any desired degree. The higher the number and quality of the triangles, the better the approximation. This approximate algorithm reduces the computational complexity to N 3 . In addition, the paper introduces a fast algorithm for the computation of 3D Zernike moments from the computed geometric moments, with a computational complexity N 4 , while the previously proposed algorithm is of order N 6 . The error introduced by the proposed approximate algorithms is evaluated in different shapes and the cost-benefit ratio in terms of error, and computational time is analyzed for different moment orders., This work was partially supported by Philips Healthcare (Best, The Netherlands), the @neurIST Integrated Project (co-financed by the European Commission through the contract no. IST-027703), the CDTI CENIT-CDTEAM grant funded by the Spanish Ministry of Industry and the research project STIMATH (TIN2009-14536-C02-01) funded by the Spanish Ministry of Science and Innovation (MICINN) and the European Regional Development Fund (ERDF)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Wall motion estimation in intracranial aneurysms

  • Oubel, E.
  • Cebral, J.R.
  • Craene, Mathieu de
  • Blanc, R.
  • Blasco, Jordi
  • Macho, Juan M.
  • Putman, C.M.
  • Frangi Caregnato, Alejandro
The quantification of wall motion in cerebral aneurysms is becoming important owing to its potential connection to rupture, and as a way to incorporate the effects of vascular compliance in computational fluid dynamics (CFD) simulations./nMost of papers report values obtained with experimental phantoms, simulated images, or animal models, but the information for real patients is limited. In this paper, we have combined non-rigid registration (IR) with signal processing techniques to measure pulsation in real patients from high frame rate digital subtraction angiography (DSA). We have obtained physiological meaningful waveforms with amplitudes in the/nrange 0mm-0.3mm for a population of 18 patients including ruptured and unruptured aneurysms. Statistically significant differences in pulsation were found according to the rupture status, in agreement with differences in biomechanical properties reported in the literature.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Patient-specific computational hemodynamics of intracranial aneurysms from 3D rotational angiography and CT angiography: an in vivo reproducibility study

  • Geers, Arjan
  • Larrabide, Ignacio, 1978-
  • Radaelli, Alessandro Guido
  • Bogunovic, Hrvoje
  • Kim, Minsuok
  • Gratama van Andel, Hugo A. F.
  • Majoie, Charles B. L. M.
  • VanBavel, E
  • Frangi Caregnato, Alejandro
Patient-specific simulations of the hemodynamics in intracranial aneurysms can be constructed by using image-based vascular models and CFD techniques. This work evaluates the impact of the choice of imaging technique on these simulations, This work was partially supported by the @neurIST Integrated Project (cofinanced by the European Commission through contract no. IST-027703) and the CD-TEAM grant funded by the Spanish Ministry of Science and Innovation. Support from Philips Healthcare B.V. and ANSYS Europe Ltd is also acknowledged.