Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Emergence of Bat-Related Betacoronaviruses: Hazard and Risks

  • Frutos, Roger
  • Serra Cobo, Jordi
  • Pinault, Lucile
  • López Roig, Marc
  • Devaux, Christian A.
The current Coronavirus Disease 2019 (COVID-19) pandemic, with more than 111 million reported cases and 2,500,000 deaths worldwide (mortality rate currently estimated at 2.2%), is a stark reminder that coronaviruses (CoV)-induced diseases remain a major threat to humanity. COVID-19 is only the latest case of betacoronavirus (β-CoV) epidemics/pandemics. In the last 20 years, two deadly CoV epidemics, Severe Acute Respiratory Syndrome (SARS; fatality rate 9.6%) and Middle East Respiratory Syndrome (MERS; fatality rate 34.7%), plus the emergence of HCoV-HKU1 which causes the winter common cold (fatality rate 0.5%), were already a source of public health concern. Betacoronaviruses can also be a threat for livestock, as evidenced by the Swine Acute Diarrhea Syndrome (SADS) epizootic in pigs. These repeated outbreaks of β-CoV-induced diseases raise the question of the dynamic of propagation of this group of viruses in wildlife and human ecosystems. SARS-CoV, SARS-CoV-2, and HCoV-HKU1 emerged in Asia, strongly suggesting the existence of a regional hot spot for emergence. However, there might be other regional hot spots, as seen with MERS-CoV, which emerged in the Arabian Peninsula. β-CoVs responsible for human respiratory infections are closely related to bat-borne viruses. Bats are present worldwide and their level of infection with CoVs is very high on all continents. However, there is as yet no evidence of direct bat-to-human coronavirus infection. Transmission of β-CoV to humans is considered to occur accidentally through contact with susceptible intermediate animal species. This zoonotic emergence is a complex process involving not only bats, wildlife and natural ecosystems, but also many anthropogenic and societal aspects. Here, we try to understand why only few hot spots of β-CoV emergence have been identified despite worldwide bats and bat-borne β-CoV distribution. In this work, we analyze and compare the natural and anthropogenic environments associated with the emergence of β-CoV and outline conserved features likely to create favorable conditions for a new epidemic. We suggest monitoring South and East Africa as well as South America as these regions bring together many of the conditions that could make them future hot spots.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Engineering photonics solutions for COVID-19

  • Soler, María
  • Scholtz, Alexis
  • Zeto, Rene
  • Armani, Andrea
As the impact of COVID-19 on society became apparent, the engineering and scientific community recognized the need for innovative solutions. Two potential roadmaps emerged: developing short-term solutions to address the immediate needs of the healthcare communities and developing mid/long-term solutions to eliminate the over-arching threat. However, in a truly global effort, researchers from all backgrounds came together in tackling this challenge. Short-term efforts have focused on re-purposing existing technologies and leveraging additive manufacturing techniques to address shortages in personal protective equipment and disinfection. More basic research efforts with mid-term and long-term impact have emphasized developing novel diagnostics and accelerating vaccines. As a foundational technology, photonics has contributed directly and indirectly to all efforts. This perspective will provide an overview of the critical role that the photonics field has played in efforts to combat the immediate COVID-19 pandemic as well as how the photonics community could anticipate contributing to future pandemics of this nature., The authors would like to thank the National Science Foundation (Grant No. 2028446) and the CoNVaT project from the H2020 research and innovation programme of the European Commission (Project Grant No. 101003544). The ICN2 was funded by the CERCA programme/Generalitat de Catalunya. The ICN2 was supported by the Severo Ochoa Centres of Excellence programme, funded by AEI (Grant No. SEV-2017-0706)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Label-free plasmonic biosensor for rapid, quantitative, and highly sensitive COVID-19 serology: implementation and clinical validation

  • Calvo-Lozano, Olalla
  • Sierra, Miquel
  • Soler, María
  • Estévez, M. Carmen
  • Chiscano- Camón, Luis
  • Ruiz-Sanmartín, Adolfo
  • Ruiz-Rodriguez, Juan Carlos
  • Ferrer, Ricard
  • González-López, Juan José
  • Esperalba, Juliana
  • Fernández-Nava, Candela
  • Bueno, Leticia
  • López-Aladid, Rubén
  • Torres, Antoni
  • Fernández-Barat, Laia
  • Attoumani, Sarah
  • Charrel, Remi
  • Coutard, Bruno
  • Lechuga, Laura M.
Serological tests are essential for the control and management of COVID-19 pandemic, not only for current and historical diagnostics but especially for surveillance, epidemiological, and acquired immunity studies. Clinical COVID-19 serology is routinely performed by enzymatic or chemiluminescence immunoassays (i.e., ELISA or CLIA), which provide good sensitivities at the expense of relatively long turnaround times and specialized laboratory settings. Rapid serological tests, based on lateral flow assays, have also been developed and widely commercialized, but they suffer from limited reliability due to relatively low sensitivity and specificity. We have developed and validated a direct serological biosensor assay employing proprietary technology based on Surface Plasmon Resonance (SPR). The biosensor offers a rapid -less than 15 min- identification and quantification of SARS-CoV-2 antibodies directly in clinical samples, without the need of any signal amplification. The portable plasmonic biosensor device employs a custom-designed multi-antigen sensor biochip, combining the two main viral antigens (RBD peptide and N protein), for simultaneous detection of human antibodies targeting both antigens. The SPR serology assay reaches detection limits in the low ng mL-1 range employing polyclonal antibodies as standard, which are well below the commonly detected antibody levels in COVID-19 patients. The assay has also been implemented employing the first WHO approved anti-SARS-CoV-2 immunoglobulin standard. We have carried out a clinical validation with COVID-19 positive and negative samples (n=120) that demonstrates the excellent diagnostic sensitivity (99%) and specificity (100%). This positions our biosensor device as an accurate, robust, and easy-to-use diagnostics tool for rapid and reliable COVID-19 serology to be employed both at laboratory and decentralized settings for the management of COVID-19 patients and for the evaluation of immunological status during vaccination, treatment or in front of emerging variants., H2020 Research and Innovation Programme of the European Commission Project, No. 101003544 Spanish Research Agency (AEI, grant no. SEV-2017-0706AEI, grant no. SEV-2017-0706) Spanish Ministry of Science and Innovation and the Spanish Research Agency and the European Social Fund (ESF)BES-2017-080527 GENCAT-DGRIS COVID EU H2020 Programme (644956) Plan Nacional de I+D+i 2013-2016 ISCIII- Ministerio de Ciencia e Innovación, Vall d’Hebron University Hospital Biobank PT17/0015/0047 European Virus Archive GLOBAL (EVA-GLOBAL) EU Horizon 2020 (grant agreement No. 871029) Fundació Glòria Soler for COVIDBANK collection Spanish Network for Research in Infectious Diseases (REIPI RD16/0016/0003), No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanophotonic biosensors for point-of-care COVID-19 diagnostics and coronavirus surveillance

  • Ruiz-Vega, Gisela
  • Soler, María
  • Lechuga, Laura M.
The COVID-19 pandemic has revealed the need of novel diagnostic technologies for rapid and accurate virus detection. In the European CONVAT project, a point-of-care nanophotonic biosensor is being developed for the direct, fast and specific identification of severe acute respiratory syndrome coronavirus 2 from both human patient samples and animal reservoirs. The technology will provide a quantitative detection of the viral load and it can be implemented in decentralized settings to improve the early diagnosis and clinical management of patients as well as coronavirus environmental monitoring to prevent future outbreaks., The work is funded by the H2020 Research and Innovation Programme of the European Commission (H2020-SC1-PHE-CORONAVIRUS-2020, Project No. 101003544). The CONVAT consortium is formed by the ICN2 (Professor Laura M. Lechuga, Spain), the University of Barcelona (UB, Professor Jordi Serra-Cobo, Spain), the Aix-Marseille University (AMU, Professor Remi Charrel and Professor Bruno Coutard, France), and the National Institute for Infectious Diseases Spallanzani (INMI, Professor Antonino di Caro, Italy). The ICN2 is funded by the CERCA programme of the Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence programme, funded by the AEI (Grand No. SEV-2017-0706)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Label-Free Plasmonic Biosensor for Rapid, Quantitative, and Highly Sensitive COVID-19 Serology: Implementation and Clinical Validation

  • Calvo-Lozano, Olalla
  • Sierra, Miquel
  • Soler, María
  • Estévez, M. Carmen
  • Chiscano- Camón, Luis
  • Ruiz-Sanmartín, Adolfo
  • Ruiz-Rodriguez, Juan Carlos
  • Ferrer, Ricard
  • González-López, Juan José
  • Esperalba, Juliana
  • Fernández-Nava, Candela
  • Bueno, Leticia
  • López-Aladid, Rubén
  • Torres, Antoni
  • Fernández-Barat, Laia
  • Attoumani, Sarah
  • Charrel, Remi
  • Coutard, Bruno
  • Lechuga, Laura M.
Serological tests are essential for the control and management of COVID-19 pandemic (diagnostics and surveillance, and epidemiological and immunity studies). We introduce a direct serological biosensor assay employing proprietary technology based on plasmonics, which offers rapid (<15 min) identification and quantification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies in clinical samples, without signal amplification. The portable plasmonic device employs a custom-designed multiantigen (RBD peptide and N protein) sensor biochip and reaches detection limits in the low ng mL–1 range employing polyclonal antibodies. It has also been implemented employing the WHO-approved anti-SARS-CoV-2 immunoglobulin standard. A clinical validation with COVID-19 positive and negative samples (n = 120) demonstrates its excellent diagnostic sensitivity (99%) and specificity (100%). This positions our biosensor as an accurate and easy-to-use diagnostics tool for rapid and reliable COVID-19 serology to be employed both at laboratory and decentralized settings for the disease management and for the evaluation of immunological status during vaccination or treatment., ICN2 and UVE acknowledge financial support from H2020 Research and Innovation Programme of the European Commission (H202-SC1-PHE-Coronavirus-2020, CONVAT Project, No. 101003544). The ICN2 is funded by the CERCA program/Generalitat de Catalunya and supported by the Severo Ochoa Centres of Excellence program funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). ICN2 group is very grateful to EPI Industries (Barcelona, Spain) for its kind donation supporting our research in COVID-19. O.C.-L. acknowledges the economic support from the Spanish Ministry of Science and Innovation and the Spanish Research Agency and the European Social Fund (ESF) (ref. BES-2017-080527) linked to the TEC 2016-78515-R project Predict. A part of the work was supported by the European Virus Archive GLOBAL (EVA-GLOBAL) project that has received funding from the EU Horizon 2020 (grant agreement No. 871029). A.T. and L.F.-B. acknowledge financial support from GENCAT-DGRIS COVID. We are indebted to all the patients who accepted to participate contributing to science advancement. We are indebted to the HCB-IDIBAPS Biobank for the human samples and data procurement and to the Fundació Glòria Soler for its support to the COVIDBANK collection. We thank the IDIBAPS Biobank for its valuable contribution to sample processing and storage. The authors acknowledge the EU Horizon 2020 Program under grant agreement no. 644956 (RAIS project) for funding the Hospital Vall d’Hebron Biobank. The VHIR-HUVH is supported by Plan Nacional de I + D + i 2013-2016 and ISCIII-Ministerio de Ciencia e Innovación, and Spanish Network for Research in Infectious Diseases (REIPI RD16/0016/0003)─cofinanced by European Development Regional Fund “A way to achieve Europe,” Operative program Intelligent Growth 2014. Part of the samples and data from patients included in this study were provided by the Vall d’Hebron University Hospital Biobank (PT17/0015/0047), integrated in the Spanish National Biobanks Network, and they were processed following standard operating procedures with the appropriate approval of the Ethical and Scientific Committee. The authors kindly appreciate the generous donation of samples and clinical data of the donors of the Sepsis Bank of HUVH Biobank and COVID-19 patients attended at HUVH., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Novel Sensing Algorithm for Linear Read-Out of Bimodal Waveguide Interferometric Biosensors

  • Bassols, Bernat
  • Ramirez-Priego, Patricia
  • Soler, María
  • Estévez, M. Carmen
  • Díaz-Luisravelo, Heriberto J.
  • Cardeñosa-Rubio, María
  • Lechuga, Laura M.
Biosensors employing photonics integrated circuits, and specifically those that rely on interferometric evanescent wave working principles, have outstanding performances due to the extreme sensitivity exhibited in one-step and direct assay, without the need of amplification. Within the interferometric configurations, the Bimodal Waveguide (BiMW) interferometric sensor stands out due to its demonstrated sensitivity for real-life applications and the simplicity of its design. To overcome the ambiguities that arise from the periodic nature of interferometric read-outs, a new all-optical modulation and the subsequent trigonometry-based algorithm have been proposed and applied to the BiMW biosensor. This new algorithm has been successfully employed for the selective identification and quantification of the external Spike (S) protein of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Our biosensing results from this simple, quick, and user-friendly method demonstrate high sensitivity and specificity and pave the way towards a point-of-care device for general use., This work was supported by the H2020 Research and Innovation Programme of the European Commission (CONVAT project, H2020-SC1-PHE- CORONAVIRUS-2020) under Grant 101003544. The ICN2 was supported by the CERCA programme of the Generalitat de Catalunya and by the Severo Ochoa Centres of Excellence Program, funded by the AEI under Grand SEV- 2017-0706.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Rapid and direct quantification of the SARS-CoV-2 virus with an ultrasensitive nanobody-based photonic nanosensor

  • Ruiz-Vega, Gisela
  • Soler, María
  • Estévez, M. Carmen
  • Ramirez-Priego, Patricia
  • Pazos, Martalu D.
  • Noriega, María A.
  • Margolles, Yago
  • Francés-Gómez, Clara
  • Geller, Ron
  • Matusali, Giulia
  • Colavita, Francesca
  • Di Caro, Antonino
  • Casasnovas, José María
  • Fernández, Luis Ángel
  • Lechuga, Laura M.
The coronavirus (CoV) disease 2019 (COVID-19) is expected to become endemic in the coming years, meaning that the worldwide society shall be prepared to routinely manage the highly contagious respiratory SARS-CoV-2. A rapid and early diagnosis of the SARS-CoV-2 infection is crucial for controlling the spread of the disease, interrupting the transmission chain, and providing timely medical attention to patients. We introduce an innovative nanophotonic biosensor for the quantitative detection of viral particles in less than 20 minutes total assay time. The nanosensor, based on the bimodal waveguide (BiMW) interferometric technology, has been functionalized with novel bioengineered nanobodies (Nb) targeting the SARS-CoV-2 receptor-binding domain (RBD). Our approach relies on the direct capture of the viral particles, and the optimized methodology allows the detection of the SARS-CoV-2 virus with outstanding sensitivity, below 200 TCID50 per mL, being able to provide accurate viral load determination within a broad dynamic range (102–106 TCID50 per mL). Both the nanobodies and the sensor nanotechnology can be produced at a large scale with highly-efficient cost-effective procedures, and they are being integrated into a user-friendly point-of-care device for multiplexed and decentralized operation. The implementation of this unique biosensor in primary care assistance, hospitals, pharmacies, or private laboratories could greatly aid in the relief and descongestion of the sanitary systems and the clinical and social management of COVID-19., This work has been mainly funded by the H2020 Research and Innovation Program of the European Commission (H2020-SC1-PHE-Coronavirus-2020, CONVAT No 101003544) and by the European Commission – NextGenerationEU (Regulation EU 2020/2094), through CSIC's Global Health Platform (PTI Salud Global – Iniciativa Estratégica de Diagnóstico). The ICN2 is funded by the CERCA Program/Generalitat de Catalunya and supported by the Severo Ochoa Centers of Excellence program, funded by the Spanish Research Agency (AEI, grant SEV-2017-0706). Work in CNB-CSIC was funded by the Spanish Ministry of Science and Innovation (MICIN) and the Spanish Research Council (CSIC) under grants PIE-RD-COVID 19 (No 202020E079) and PTI Salud Global REC_EU (No SGL 2103051, NextGenerationEU). Work at I2SysBio was funded by Ayudas de concesión directa a soluciones científico-innovadoras directamente relacionadas con la lucha contra la Covid-19 grant from the Generalitat Valenciana, Spanish National Research Council grant CSIC-COV19-082/104, Fondo Supera Covid-19 grant BlockAce, and European Commission – NextGenerationEU to Ron Geller. INMI received funds for this study from the Ministero della Salute (Ricerca Corrente - linea 1), the European Commission – Horizon 2020 (EU project 101003544 – CoNVat) and the European Virus Archive – GLOBAL (grants no. 653316 and no. 871029), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Biomimetic nanoplasmonic sensor for rapid evaluation of neutralizing SARS-CoV-2 monoclonal antibodies as antiviral therapy

  • Batool, Razia
  • Soler, María
  • Colavita, Francesca
  • Fabeni, Lavinia
  • Matusali, Giulia
  • Lechuga, Laura M.
Monoclonal antibody (mAb) therapy is one of the most promising immunotherapies that have shown the potential to prevent or neutralize the effects of COVID-19 in patients at very early stages, with a few formulations recently approved by the European and American medicine agencies. However, a main bottleneck for their general implementation resides in the time-consuming, laborious, and highly-specialized techniques employed for the manufacturing and assessing of these therapies, excessively increasing their prices and delaying their administration to the patients. We propose a biomimetic nanoplasmonic biosensor as a novel analytical technique for the screening and evaluation of COVID-19 mAb therapies in a simpler, faster, and reliable manner. By creating an artificial cell membrane on the plasmonic sensor surface, our label-free sensing approach enables real-time monitoring of virus-cell interactions as well as direct analysis of antibody blocking effects in only 15 min assay time. We have achieved detection limits in the 102 TCID50/mL range for the study of SARS-CoV-2 viruses, which allows to perform neutralization assays by only employing a low-volume sample with common viral loads. We have demonstrated the accuracy of the biosensor for the evaluation of two different neutralizing antibodies targeting both Delta and Omicron variants of SARS-CoV-2, with half maximal inhibitory concentrations (IC50) determined in the ng/mL range. Our user-friendly and reliable technology could be employed in biomedical and pharmaceutical laboratories to accelerate, cheapen, and simplify the development of effective immunotherapies for COVID-19 and other serious infectious diseases or cancer., Financial support is acknowledged from the SensCELL project (Ref. No. PGC-2018-099870), funded by the Spanish Ministry of Science and Innovation (MCIN), the Spanish Research Agency (AEI), and the European Regional Development Fund (ERDF), and from the CONVAT project (Ref. 101003544), funded by the H2020 Research and Innovation Programme of the European Commission (H2020-SC1-PHE-Coronavirus-2020). RB acknowledges the economic support (Ref. PRE2019- 089357) from MCIN and AEI linked to the project SEV-2017-0706-19-4. MS acknowledges the economic support of the Ramon y Cajal Grant (RYC2020-029015-I) funded by the AEI/MCIN and the European Union NextGenerationEU/PRTR. INMI also acknowledges funding from the European Virus Archive – GLOBAL (Grant No. 871029). The ICN2 is supported by the CERCA programme (Generalitat de Catalunya) and the Severo Ochoa Centres of Excellence programme, funded by the AEI (Grant. No. SEV-2017-0706)., Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Emergence of Bat-Related Betacoronaviruses: Hazard and Risks

  • Frutos, Roger
  • Serra Cobo, Jordi
  • Pinault, Lucile
  • López Roig, Marc
  • Devaux, Christian A.
The current Coronavirus Disease 2019 (COVID-19) pandemic, with more than 111 million reported cases and 2,500,000 deaths worldwide (mortality rate currently estimated at 2.2%), is a stark reminder that coronaviruses (CoV)-induced diseases remain a major threat to humanity. COVID-19 is only the latest case of betacoronavirus (β-CoV) epidemics/pandemics. In the last 20 years, two deadly CoV epidemics, Severe Acute Respiratory Syndrome (SARS; fatality rate 9.6%) and Middle East Respiratory Syndrome (MERS; fatality rate 34.7%), plus the emergence of HCoV-HKU1 which causes the winter common cold (fatality rate 0.5%), were already a source of public health concern. Betacoronaviruses can also be a threat for livestock, as evidenced by the Swine Acute Diarrhea Syndrome (SADS) epizootic in pigs. These repeated outbreaks of β-CoV-induced diseases raise the question of the dynamic of propagation of this group of viruses in wildlife and human ecosystems. SARS-CoV, SARS-CoV-2, and HCoV-HKU1 emerged in Asia, strongly suggesting the existence of a regional hot spot for emergence. However, there might be other regional hot spots, as seen with MERS-CoV, which emerged in the Arabian Peninsula. β-CoVs responsible for human respiratory infections are closely related to bat-borne viruses. Bats are present worldwide and their level of infection with CoVs is very high on all continents. However, there is as yet no evidence of direct bat-to-human coronavirus infection. Transmission of β-CoV to humans is considered to occur accidentally through contact with susceptible intermediate animal species. This zoonotic emergence is a complex process involving not only bats, wildlife and natural ecosystems, but also many anthropogenic and societal aspects. Here, we try to understand why only few hot spots of β-CoV emergence have been identified despite worldwide bats and bat-borne β-CoV distribution. In this work, we analyze and compare the natural and anthropogenic environments associated with the emergence of β-CoV and outline conserved features likely to create favorable conditions for a new epidemic. We suggest monitoring South and East Africa as well as South America as these regions bring together many of the conditions that could make them future hot spots.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Label-Free Plasmonic Biosensor for Rapid, Quantitative, and Highly Sensitive COVID-19 Serology: Implementation and Clinical Validation

  • Calvo Lozano, Olalla
  • Sierra Montoya, Miquel
  • Soler, Maria
  • Estevez, M. Carmen
  • Chiscano Camon, Luis Silvestre
  • Ruiz Sanmartin, Adolfo
  • Ruiz Rodriguez, Juan Carlos
  • Ferrer Roca, Ricard
  • Gonzalez Lopez, Juan Jose
  • Esperalba Esquerra, Juliana
  • Fernandez Naval, Candela
COVID-19; Biosensor plasmónico; Serología, COVID-19; Biosensor plasmònic; Serologia, COVID-19; Plasmonic biosensor; Serology, Serological tests are essential for the control and management of COVID-19 pandemic (diagnostics and surveillance, and epidemiological and immunity studies). We introduce a direct serological biosensor assay employing proprietary technology based on plasmonics, which offers rapid (<15 min) identification and quantification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies in clinical samples, without signal amplification. The portable plasmonic device employs a custom-designed multiantigen (RBD peptide and N protein) sensor biochip and reaches detection limits in the low ng mL–1 range employing polyclonal antibodies. It has also been implemented employing the WHO-approved anti-SARS-CoV-2 immunoglobulin standard. A clinical validation with COVID-19 positive and negative samples (n = 120) demonstrates its excellent diagnostic sensitivity (99%) and specificity (100%). This positions our biosensor as an accurate and easy-to-use diagnostics tool for rapid and reliable COVID-19 serology to be employed both at laboratory and decentralized settings for the disease management and for the evaluation of immunological status during vaccination or treatment., ICN2 and UVE acknowledge financial support from H2020 Research and Innovation Programme of the European Commission (H202-SC1-PHE-Coronavirus-2020, CONVAT Project, No. 101003544). The ICN2 is funded by the CERCA program/Generalitat de Catalunya and supported by the Severo Ochoa Centres of Excellence program funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). ICN2 group is very grateful to EPI Industries (Barcelona, Spain) for its kind donation supporting our research in COVID-19. O.C.-L. acknowledges the economic support from the Spanish Ministry of Science and Innovation and the Spanish Research Agency and the European Social Fund (ESF) (ref. BES-2017-080527) linked to the TEC 2016-78515-R project Predict. A part of the work was supported by the European Virus Archive GLOBAL (EVA-GLOBAL) project that has received funding from the EU Horizon 2020 (grant agreement No. 871029). A.T. and L.F.-B. acknowledge financial support from GENCAT-DGRIS COVID. We are indebted to all the patients who accepted to participate contributing to science advancement. We are indebted to the HCB-IDIBAPS Biobank for the human samples and data procurement and to the Fundació Glòria Soler for its support to the COVIDBANK collection. We thank the IDIBAPS Biobank for its valuable contribution to sample processing and storage. The authors acknowledge the EU Horizon 2020 Program under grant agreement no. 644956 (RAIS project) for funding the Hospital Vall d’Hebron Biobank. The VHIR-HUVH is supported by Plan Nacional de I + D + i 2013-2016 and ISCIII-Ministerio de Ciencia e Innovación, and Spanish Network for Research in Infectious Diseases (REIPI RD16/0016/0003)─cofinanced by European Development Regional Fund “A way to achieve Europe,” Operative program Intelligent Growth 2014. Part of the samples and data from patients included in this study were provided by the Vall d’Hebron University Hospital Biobank (PT17/0015/0047), integrated in the Spanish National Biobanks Network, and they were processed following standard operating procedures with the appropriate approval of the Ethical and Scientific Committee. The authors kindly appreciate the generous donation of samples and clinical data of the donors of the Sepsis Bank of HUVH Biobank and COVID-19 patients attended at HUVH.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

How Nanophotonic Label-Free Biosensors Can Contribute to Rapid and Massive Diagnostics of Respiratory Virus Infections, COVID-19 Case

  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Estévez, M. Carmen|||0000-0003-3694-7186
  • Cardenosa-Rubio, Maria|||0000-0001-8616-5030
  • Astua, Alejandro
  • Lechuga, Laura M|||0000-0001-5187-5358
The global sanitary crisis caused by the emergence of the respiratory virus SARS-CoV-2 and the COVID-19 outbreak has revealed the urgent need for rapid, accurate, and affordable diagnostic tests to broadly and massively monitor the population in order to properly manage and control the spread of the pandemic. Current diagnostic techniques essentially rely on polymerase chain reaction (PCR) tests, which provide the required sensitivity and specificity. However, its relatively long time-to-result, including sample transport to a specialized laboratory, delays massive detection. Rapid lateral flow tests (both antigen and serological tests) are a remarkable alternative for rapid point-of-care diagnostics, but they exhibit critical limitations as they do not always achieve the required sensitivity for reliable diagnostics and surveillance. Next-generation diagnostic tools capable of overcoming all the above limitations are in demand, and optical biosensors are an excellent option to surpass such critical issues. Label-free nanophotonic biosensors offer high sensitivity and operational robustness with an enormous potential for integration in compact autonomous devices to be delivered out-of-the-lab at the point-of-care (POC). Taking the current COVID-19 pandemic as a critical case scenario, we provide an overview of the diagnostic techniques for respiratory viruses and analyze how nanophotonic biosensors can contribute to improving such diagnostics. We review the ongoing published work using this biosensor technology for intact virus detection, nucleic acid detection or serological tests, and the key factors for bringing nanophotonic POC biosensors to accurate and effective COVID-19 diagnosis on the short term.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Engineering photonics solutions for COVID-19

  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Scholtz, Alexis
  • Zeto, Rene
  • Armani, Andrea M.|||0000-0001-9890-5104
As the impact of COVID-19 on society became apparent, the engineering and scientific community recognized the need for innovative solutions. Two potential roadmaps emerged: Developing short-term solutions to address the immediate needs of the healthcare communities and developing mid/long-term solutions to eliminate the over-arching threat. However, in a truly global effort, researchers from all backgrounds came together in tackling this challenge. Short-term efforts have focused on re-purposing existing technologies and leveraging additive manufacturing techniques to address shortages in personal protective equipment and disinfection. More basic research efforts with mid-term and long-term impact have emphasized developing novel diagnostics and accelerating vaccines. As a foundational technology, photonics has contributed directly and indirectly to all efforts. This perspective will provide an overview of the critical role that the photonics field has played in efforts to combat the immediate COVID-19 pandemic as well as how the photonics community could anticipate contributing to future pandemics of this nature.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanophotonic biosensors for point-of-care COVID-19 diagnostics and coronavirus surveillance

  • Ruiz Vega, Gisela|||0000-0002-8438-3146
  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Lechuga, Laura M|||0000-0001-5187-5358
The COVID-19 pandemic has revealed the need of novel diagnostic technologies for rapid and accurate virus detection. In the European CONVAT project, a point-of-care nanophotonic biosensor is being developed for the direct, fast and specific identification of severe acute respiratory syndrome coronavirus 2 from both human patient samples and animal reservoirs. The technology will provide a quantitative detection of the viral load and it can be implemented in decentralized settings to improve the early diagnosis and clinical management of patients as well as coronavirus environmental monitoring to prevent future outbreaks.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Label-Free Plasmonic Biosensor for Rapid, Quantitative, and Highly Sensitive COVID-19 Serology, Implementation and Clinical Validation

  • Calvo Lozano, Olalla|||0000-0001-5486-2237
  • Sierra, Miquel
  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Estévez, M. Carmen|||0000-0003-3694-7186
  • Chiscano-Camón, Luis|||0000-0003-0037-0610
  • Ruiz-Sanmartin, Adolfo
  • Ruiz-Rodriguez, Juan Carlos|||0000-0001-7392-8617
  • Ferrer, Ricard|||0000-0002-4859-4747
  • González-López, Juanjo|||0000-0003-2419-5909
  • Esperalba, Juliana|||0000-0003-1326-1341
  • Fernandez-Naval, Candela|||0000-0002-5584-3537
  • Bueno, Leticia
  • López-Aladid, Ruben
  • Torres, Antoni|||0000-0002-8643-2167
  • Fernández Barat, Laia|||0000-0001-7528-9636
  • Attoumani, Sarah
  • Charrel, Rémi
  • Coutard, Bruno
  • Lechuga, Laura M.|||0000-0001-5187-5358
Serological tests are essential for the control and management of COVID-19 pandemic (diagnostics and surveillance, and epidemiological and immunity studies). We introduce a direct serological biosensor assay employing proprietary technology based on plasmonics, which offers rapid (<15 min) identification and quantification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies in clinical samples, without signal amplification. The portable plasmonic device employs a custom-designed multiantigen (RBD peptide and N protein) sensor biochip and reaches detection limits in the low ng mL -1 range employing polyclonal antibodies. It has also been implemented employing the WHO-approved anti-SARS-CoV-2 immunoglobulin standard. A clinical validation with COVID-19 positive and negative samples (n = 120) demonstrates its excellent diagnostic sensitivity (99%) and specificity (100%). This positions our biosensor as an accurate and easy-to-use diagnostics tool for rapid and reliable COVID-19 serology to be employed both at laboratory and decentralized settings for the disease management and for the evaluation of immunological status during vaccination or treatment.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Novel sensing algorithm for linear read-out of bimodal waveguide interferometric biosensors

  • Bassols-Cornudella, Bernat|||0000-0001-6620-6739
  • Ramirez Priego, Patricia|||0000-0001-5657-3279
  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Estévez, M. Carmen|||0000-0003-3694-7186
  • Díaz-Luisravelo, Heriberto J|||0000-0003-4181-1240
  • Cardenosa-Rubio, Maria|||0000-0001-8616-5030
  • Lechuga, Laura M|||0000-0001-5187-5358
Biosensors employing photonics integrated circuits, and specifically those that rely on interferometric evanescent wave working principles, have outstanding performances due to the extreme sensitivity exhibited in one-step and direct assay, without the need of amplification. Within the interferometric configurations, the Bimodal Waveguide (BiMW) interferometric sensor stands out due to its demonstrated sensitivity for real-life applications and the simplicity of its design. To overcome the ambiguities that arise from the periodic nature of interferometric read-outs, a new all-optical modulation and the subsequent trigonometry-based algorithm have been proposed and applied to the BiMW biosensor. This new algorithm has been successfully employed for the selective identification and quantification of the external Spike (S) protein of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Our biosensing results from this simple, quick, and user-friendly method demonstrate high sensitivity and specificity and pave the way towards a point-of-care device for general use.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Rapid and direct quantification of the SARS-CoV-2 virus with an ultrasensitive nanobody-based photonic nanosensor

  • Ruiz Vega, Gisela|||0000-0002-8438-3146
  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Estévez, M. Carmen|||0000-0003-3694-7186
  • Ramirez Priego, Patricia|||0000-0001-5657-3279
  • Pazos, Martalu D.
  • Noriega, María A.
  • Margolles, Yago
  • Francés-Gómez, Clara
  • Geller, Ron
  • Matusali, Giulia
  • Colavita, Francesca
  • Caro, Antonino di
  • Casasnovas, José M.|||0000-0002-2873-6410
  • Fernández, Luis Angel
  • Lechuga, Laura M|||0000-0001-5187-5358
The coronavirus (CoV) disease 2019 (COVID-19) is expected to become endemic in the coming years, meaning that the worldwide society shall be prepared to routinely manage the highly contagious respiratory SARS-CoV-2. A rapid and early diagnosis of the SARS-CoV-2 infection is crucial for controlling the spread of the disease, interrupting the transmission chain, and providing timely medical attention to patients. We introduce an innovative nanophotonic biosensor for the quantitative detection of viral particles in less than 20 minutes total assay time. The nanosensor, based on the bimodal waveguide (BiMW) interferometric technology, has been functionalized with novel bioengineered nanobodies (Nb) targeting the SARS-CoV-2 receptor-binding domain (RBD). Our approach relies on the direct capture of the viral particles, and the optimized methodology allows the detection of the SARS-CoV-2 virus with outstanding sensitivity, below 200 TCID50 per mL, being able to provide accurate viral load determination within a broad dynamic range (102-106 TCID50 per mL). Both the nanobodies and the sensor nanotechnology can be produced at a large scale with highly-efficient cost-effective procedures, and they are being integrated into a user-friendly point-of-care device for multiplexed and decentralized operation. The implementation of this unique biosensor in primary care assistance, hospitals, pharmacies, or private laboratories could greatly aid in the relief and descongestion of the sanitary systems and the clinical and social management of COVID-19.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Biomimetic nanoplasmonic sensor for rapid evaluation of neutralizing SARS-CoV-2 monoclonal antibodies as antiviral therapy

  • Batool, Razia|||0000-0001-6864-5655
  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Colavita, Francesca
  • Fabeni, Lavinia|||0000-0002-2975-8611
  • Matusali, Giulia
  • Lechuga, Laura M|||0000-0001-5187-5358
Monoclonal antibody (mAb) therapy is one of the most promising immunotherapies that have shown the potential to prevent or neutralize the effects of COVID-19 in patients at very early stages, with a few formulations recently approved by the European and American medicine agencies. However, a main bottleneck for their general implementation resides in the time-consuming, laborious, and highly-specialized techniques employed for the manufacturing and assessing of these therapies, excessively increasing their prices and delaying their administration to the patients. We propose a biomimetic nanoplasmonic biosensor as a novel analytical technique for the screening and evaluation of COVID-19 mAb therapies in a simpler, faster, and reliable manner. By creating an artificial cell membrane on the plasmonic sensor surface, our label-free sensing approach enables real-time monitoring of virus-cell interactions as well as direct analysis of antibody blocking effects in only 15 min assay time. We have achieved detection limits in the 10 TCID50/mL range for the study of SARS-CoV-2 viruses, which allows to perform neutralization assays by only employing a low-volume sample with common viral loads. We have demonstrated the accuracy of the biosensor for the evaluation of two different neutralizing antibodies targeting both Delta and Omicron variants of SARS-CoV-2, with half maximal inhibitory concentrations (IC) determined in the ng/mL range. Our user-friendly and reliable technology could be employed in biomedical and pharmaceutical laboratories to accelerate, cheapen, and simplify the development of effective immunotherapies for COVID-19 and other serious infectious diseases or cancer.
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Label-Free Plasmonic Biosensor for Rapid, Quantitative, and Highly Sensitive COVID-19 Serology: Implementation and Clinical Validation

  • Calvo Lozano, Olalla
  • Sierra Montoya, Miquel
  • Soler, Maria
  • Estevez, M. Carmen
  • Chiscano Camon, Luis Silvestre
  • Ruiz Sanmartin, Adolfo
  • Ruiz Rodriguez, Juan Carlos
  • Ferrer Roca, Ricard
  • Gonzalez Lopez, Juan Jose
  • Esperalba Esquerra, Juliana
  • Fernandez Naval, Candela
COVID-19; Biosensor plasmónico; Serología, COVID-19; Biosensor plasmònic; Serologia, COVID-19; Plasmonic biosensor; Serology, Serological tests are essential for the control and management of COVID-19 pandemic (diagnostics and surveillance, and epidemiological and immunity studies). We introduce a direct serological biosensor assay employing proprietary technology based on plasmonics, which offers rapid (<15 min) identification and quantification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies in clinical samples, without signal amplification. The portable plasmonic device employs a custom-designed multiantigen (RBD peptide and N protein) sensor biochip and reaches detection limits in the low ng mL–1 range employing polyclonal antibodies. It has also been implemented employing the WHO-approved anti-SARS-CoV-2 immunoglobulin standard. A clinical validation with COVID-19 positive and negative samples (n = 120) demonstrates its excellent diagnostic sensitivity (99%) and specificity (100%). This positions our biosensor as an accurate and easy-to-use diagnostics tool for rapid and reliable COVID-19 serology to be employed both at laboratory and decentralized settings for the disease management and for the evaluation of immunological status during vaccination or treatment., ICN2 and UVE acknowledge financial support from H2020 Research and Innovation Programme of the European Commission (H202-SC1-PHE-Coronavirus-2020, CONVAT Project, No. 101003544). The ICN2 is funded by the CERCA program/Generalitat de Catalunya and supported by the Severo Ochoa Centres of Excellence program funded by the Spanish Research Agency (AEI, grant no. SEV-2017-0706). ICN2 group is very grateful to EPI Industries (Barcelona, Spain) for its kind donation supporting our research in COVID-19. O.C.-L. acknowledges the economic support from the Spanish Ministry of Science and Innovation and the Spanish Research Agency and the European Social Fund (ESF) (ref. BES-2017-080527) linked to the TEC 2016-78515-R project Predict. A part of the work was supported by the European Virus Archive GLOBAL (EVA-GLOBAL) project that has received funding from the EU Horizon 2020 (grant agreement No. 871029). A.T. and L.F.-B. acknowledge financial support from GENCAT-DGRIS COVID. We are indebted to all the patients who accepted to participate contributing to science advancement. We are indebted to the HCB-IDIBAPS Biobank for the human samples and data procurement and to the Fundació Glòria Soler for its support to the COVIDBANK collection. We thank the IDIBAPS Biobank for its valuable contribution to sample processing and storage. The authors acknowledge the EU Horizon 2020 Program under grant agreement no. 644956 (RAIS project) for funding the Hospital Vall d’Hebron Biobank. The VHIR-HUVH is supported by Plan Nacional de I + D + i 2013-2016 and ISCIII-Ministerio de Ciencia e Innovación, and Spanish Network for Research in Infectious Diseases (REIPI RD16/0016/0003)─cofinanced by European Development Regional Fund “A way to achieve Europe,” Operative program Intelligent Growth 2014. Part of the samples and data from patients included in this study were provided by the Vall d’Hebron University Hospital Biobank (PT17/0015/0047), integrated in the Spanish National Biobanks Network, and they were processed following standard operating procedures with the appropriate approval of the Ethical and Scientific Committee. The authors kindly appreciate the generous donation of samples and clinical data of the donors of the Sepsis Bank of HUVH Biobank and COVID-19 patients attended at HUVH.