Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Exposures in indoor air affecting health

  • Hartiala, Maria
  • García Aymerich, Judith
  • Koch, Sarah
  • Mueller, Natalie, 1988-
  • Opbroek, Jet
  • Pozdniakova, Sofya
  • IDEAL Consortium
Indoor air quality (IAQ) is influenced by a wide range of chemical, biological and physical agents that can negatively impact physical, immunological and mental health. Adverse health effects depend on the type and concentration of pollutants, duration of exposure, and individual susceptibility. The availability of data on IAQ is limited, as are standardized approaches for evaluating its health impact. This expert review aims to describe the most important indoor air determinants affecting health, and present the IDEAL cluster, which comprises seven EU-funded scientific projects on the topic of IAQ and human health. Across the IDEAL projects, knowledge is generated on exposure to a wide range of indoor air pollutants, including well-known hazards and more explorative chemical and microbiological determinants. The projects will also contribute to the implementation of low-cost and/or real-time sensors on IAQ, as well as advanced chemical and microbiological analyses, and evaluate various interventions to improve IAQ. Several of them focus on particularly vulnerable groups. Raising public awareness and implementing measures to reduce pollutant levels are essential for safeguarding health, particularly in urban areas with elevated pollution levels., The project was funded by the Horizon Europe project SynAir-G, grant agreement ID: 101057271. This work was co-funded by the Horizon Europe INQUIRE project (grant agreement number 101057499) and by the UK Research and Innovation (UKRI) under the UK government's Horizon Europe funding guarantee (grant number 10042425). This work is part of the TwinAIR project, funded by the EU's Horizon Europe program (grant agreement number 101057779). InChildHealth is receiving funding from the European Union's Horizon Europe research under grant agreement 101056883, from the State Secretariat for Education, Research and Innovation (SERI grant agreement 22.00324), from the UK Research and Innovation (UKRI grant agreement 10040524), and from the Australian National Health and Medical Research Council (NHMRC grant agreements APP2017786 and APP2008813). This work has received financial support from the K-HEALTHinAIR project, grant agreement number 101057693, under a European Union's Call on Environment and Health (HORIZON-HLTH-2021-ENVHLTH-02). This work was supported by the affiliated institutions, European Regional Development Fund project KK.01.1.1.02.0007 (Rec-IMI), the Croatian Science Foundation (HUMNap project #1192), the Horizon Europe (EDIAQI project #101057497), Next Generation EU 533-03-23-0006 (BioMolTox). The authors wish to acknowledge Tanzeela Hanif for their expertise concerning the graphic design of this manuscript. Open access publishing facilitated by Turun yliopisto, as part of the Wiley - FinELib agreement.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

The InChildHealth Walkthrough Survey - towards a standardized characterization of classrooms for Indoor Air Quality studies in Europe

  • Vorkamp, Katrin
  • Viegas, Carla
  • Almeida, Marta
  • Aretaki, Maria Antonia
  • Bossi, Rossana
  • Castagnoli, Emmanuelle
  • Cervantes, Renata
  • Desmet, Judith
  • Diapouli, Evangelia
  • Domínguez, Alan
  • Fabian, Claudia M.
  • Fauser, Patrik
The Horizon Europe project InChildHealth aims to study indoor air quality in European schools and the effects of physical, chemical and microbiological parameters on the health of school children aged 6-13. As schools in Europe can vary considerably in terms of size, age, materials, equipment, heating, ventilation and air conditioning (HVAC), cleaning procedures etc., a questionnaire was developed for a standardized description of classrooms and schools. It includes 86 mandatory and 82 optional questions, targeting building characteristics and potential sources of exposure to particles, chemicals and microorganisms. The survey has been implemented digitally with the option of paper-based versions and future data sharing for combined data interpretation. The project foresees the possibility of revisions based on lessons learnt from the application in seven European cities. The final version can be adjusted to other microenvironments and used in future indoor air studies in Europe and elsewhere. © 2024 18th Conference of the International Society of Indoor Air Quality and Climate, INDOOR AIR 2024, The project has received funding from European Union\u2019s Horizon Europe Research and Innovation programme under Grant Agreement No. 101056883., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development of a strategy for sampling, preservation, and analysis of classical and emerging flame retardants and plasticizers in air samples

  • Desmet, Judith
  • Aretaki, Maria A.
  • Viana, Mar
  • Eljarrat, Ethel
This study presents a methodology for sampling, preserving, and analyzing 15 organophosphate esters (OPEs), 11 phthalate esters (PEs), and 6 alternative plasticizers (APs) in indoor air. Accurate quantification is essential, given their widespread use in household items and adverse health effects associated with exposure. Solid-phase extraction (SPE) cartridges, collecting both gaseous and particulate phases, connected to a low-volume pump were used for the collection of air samples. Stability tests confirm that storing samples at 4 °C is most optimal to maintain analyte integrity for at least 2 weeks. The analytes were extracted and then purified online using turbulent flow chromatography, before analysis via liquid chromatography-tandem mass spectrometry (TFC-LC-MS/MS). Quantification was carried out by applying the isotopic dilution method with labelled standards. Recoveries ranged from 50 to 136%, with reproducibility below 21%. The relative standard deviation (RSD) varied from 2 to 31%, only exceeding the 20% threshold for certain OPEs at lower concentrations. Limits of detection (mLODs) varied between 0.02-0.89 ng/m3, 0.02-20.0 ng/m3, and 0.07-1.47 ng/m3 for OPEs, PEs, and APs, respectively. The study demonstrates that this methodology is effective, cost-efficient, and suitable for monitoring a total of 33 flame retardants and plasticizers in indoor air. It minimizes material costs and sample handling time by allowing direct analysis without pretreatment. Results from indoor air samples collected in a case study revealed that OPEs attributed to less than 20% of the chemical profile, while triethyl citrate (TEC) was detected at concentrations up to 28.9 ng/m3, confirming the method's applicability for the added APs., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was funded by project InChildHealth (grant agreement ID: 101056883), by the European Health and DIGITAL Executive Agency (HaDEA) under the Horizon Europe Framework Programme., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Determination of Polycyclic Aromatic Hydrocarbons and Organic Molecular Tracer Compounds in Dusts Samples from Schools in Puchuncaví and Quintero (Chile)

  • Parra, Sonnia
  • Bravo, Manuel A.
  • Van Drooge, Barend L.
This article belongs to the Special Issue Emerging Contaminants and Their Transformation Products in the Environment: Advanced Analytical Methods for Assessing Ecological and Human Health Impacts., This investigation was conducted in order to gain a first knowledge of concentrations, distribution patterns, and potential sources of 16 US EPA priority polycyclic aromatic hydrocarbons (PAHs) and organic molecular tracer compounds in deposition dust samples collected in the Valparaiso region, Chile. Dust was sampled in schools (indoor and outdoor) that are located in Puchuncaví and Quintero. Source apportionment analysis using the concentrations of PAHs; glucose, mannitol, sucrose, fructose; di-2-ethylhexyl phthalate; hopanes, and levoglucosan as molecular tracer compounds showed three sources of contribution. The first (46.38%) was related to incomplete combustion processes (Acy, Flu, Ant, Flt, Pyr, and BaA), a second source (20%) represented soil+ biomass burning (levoglucosan, α glucose, β glucose, mannitol, sucrose, and fructose), and a third source (10.26%) was dominated only by 27_norhopane, 27_hopane, which are related to traffic. To assess potential health risks for schoolchildren, the study calculated the benzo[a]pyrene equivalent (BaPE) toxicity and the incremental lifetime cancer risk (ILCR). Toxicity equivalent (TEQ) results showed that the main contributor to overall toxicity in PAHs, especially in schools located in Puchuncaví, was benzo[a]pyrene (BaP), followed by benzo[α]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), indeno[1,2,3-cd] pyrene (IcdP), and dibenzo[a,h]anthracene (DahA). According to the calculated ILCR values, the highest cancer risk was associated with dust ingestion (both indoor and outdoor) for ∑16PAHs, ranging from 1.14 × 10−3 to 8.88 × 10−4. This was followed by dermal contact (1.27 × 10−5 to 7.27 × 10−7) and inhalation (1.22 × 10−8 to 9.99 × 10−9)., The research work of Sonnia Parra was partially supported by to the Dirección de Investigación y Estudios Avanzados (VRIEA-PUCV) project 039.345/2021. Barend Drooge was supported by the European Commission EU Horizon for financial support (IN CHILD HEALTH EU Horizon 101056883)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Children's exposure to airborne microplastics in school classrooms: linking indoor concentrations with respiratory deposition modelling

  • Torres-Agullo, Ana
  • Lacorte Bruguera, Silvia
  • Lazaridis, Mihalis
  • Chalvatzaki, Eleftheria
  • Chatoutsidou, Sofia Eirini
  • Karanasiou, Angeliki
Ensuring good indoor air quality in schools is essential for healthy child development. Airborne microplastics (MP) pollution has attracted increasing attention in recent years due to the potential negative impact on human health, especially in indoor environments where people spend approximately 90% of their time. The present study is one of the first to combine real classroom airborne microplastic measurements with respiratory deposition and clearance modelling, enabling a health-relevant evaluation of lung-deposited dose in children. We collected total suspended particles from indoor air in 5 primary schools (n = 25) across the urban area of Barcelona to assess MP concentrations and composition. Quantitative analysis was performed by pyrolysis coupled to gas chromatography high-resolution mass spectrometry, a size-unrestricted technique targeting ten polymer types. Total MP concentrations ranged from 64.9 ± 24.3 to 178.7 ± 47.7 ng/m3 with a mean value of 99.7 ± 44.4 ng/m3. Nylon 6,6 and nitrile butadiene rubber (NBR) were detected in all the samples, with NBR showing the highest concentrations (36.8 ± 14.1 to 109.6 ± 23.6 ng/m3). To evaluate potential health implications, the ExDoM2 dosimetry model based on the International Commission on Radiological Protection framework was applied to estimate respiratory deposition and clearance in children. On average, 32 ± 8 particles were deposited during an 8-h school day, corresponding to a mass dose of 254 ± 68 ng. After 24 h, 60-67% of the deposited mass was cleared to the gastrointestinal tract via mucociliary transport, and less than 1% was estimated to reach the bloodstream. These results highlight the relevance of inhalation exposure to MP in school environments and the necessity of additional research during critical developmental stages., This work was funded by project InChildHealth funded from the European Union’s Horizon Europe research under grant agreement 101056883. Views and opinions expressed are however those of the author(s) only and do not necessarily reflect those of the European Health and Digital Executive Agency (HaDEA). Neither the European Union nor the granting authority can be held responsible for them. InChildHealth is also receiving funding from the Swiss State Secretariat for Education, Research and Innovation (SERI grant agreement 22.00324), from the United Kingdom Research and Innovation (UKRI grant agreement 10040524), and from the Australian National Health & Medical Research Council (NHMRC grant agreements APP2017786 and APP2008813). The Spanish Ministry of Science and Innovation is acknowledged for financial support [PID2022-137766NB-I00] and for the predoctoral grant of A. Torres-Agullo (PRE2021-097960). Maria Antonia Aretaki and Judith Desmet are acknowledged to help during the sampling campaign. The participating schools, teachers and pupils are also thanked for their collaboration., Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Exposures in indoor air affecting health

  • Hartiala, Maria
  • García Aymerich, Judith
  • Koch, Sarah
  • Mueller, Natalie, 1988-
  • Opbroek, Jet
  • Pozdniakova, Sofya
  • IDEAL Consortium
Indoor air quality (IAQ) is influenced by a wide range of chemical, biological and physical agents that can negatively impact physical, immunological and mental health. Adverse health effects depend on the type and concentration of pollutants, duration of exposure, and individual susceptibility. The availability of data on IAQ is limited, as are standardized approaches for evaluating its health impact. This expert review aims to describe the most important indoor air determinants affecting health, and present the IDEAL cluster, which comprises seven EU-funded scientific projects on the topic of IAQ and human health. Across the IDEAL projects, knowledge is generated on exposure to a wide range of indoor air pollutants, including well-known hazards and more explorative chemical and microbiological determinants. The projects will also contribute to the implementation of low-cost and/or real-time sensors on IAQ, as well as advanced chemical and microbiological analyses, and evaluate various interventions to improve IAQ. Several of them focus on particularly vulnerable groups. Raising public awareness and implementing measures to reduce pollutant levels are essential for safeguarding health, particularly in urban areas with elevated pollution levels., The project was funded by the Horizon Europe project SynAir-G, grant agreement ID: 101057271. This work was co-funded by the Horizon Europe INQUIRE project (grant agreement number 101057499) and by the UK Research and Innovation (UKRI) under the UK government's Horizon Europe funding guarantee (grant number 10042425). This work is part of the TwinAIR project, funded by the EU's Horizon Europe program (grant agreement number 101057779). InChildHealth is receiving funding from the European Union's Horizon Europe research under grant agreement 101056883, from the State Secretariat for Education, Research and Innovation (SERI grant agreement 22.00324), from the UK Research and Innovation (UKRI grant agreement 10040524), and from the Australian National Health and Medical Research Council (NHMRC grant agreements APP2017786 and APP2008813). This work has received financial support from the K-HEALTHinAIR project, grant agreement number 101057693, under a European Union's Call on Environment and Health (HORIZON-HLTH-2021-ENVHLTH-02). This work was supported by the affiliated institutions, European Regional Development Fund project KK.01.1.1.02.0007 (Rec-IMI), the Croatian Science Foundation (HUMNap project #1192), the Horizon Europe (EDIAQI project #101057497), Next Generation EU 533-03-23-0006 (BioMolTox). The authors wish to acknowledge Tanzeela Hanif for their expertise concerning the graphic design of this manuscript. Open access publishing facilitated by Turun yliopisto, as part of the Wiley - FinELib agreement.