Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanoporous Graphene Integrated onto Bimodal Waveguide Biosensors for Detection of C-Reactive Protein

  • Lisboa, Bárbara|||0000-0002-3231-7411
  • Soler Aznar, Maria|||0000-0001-7232-2277
  • Singh, Rukmani|||0000-0002-7562-7217
  • Castro-Esteban, Jesús|||0000-0003-0100-943X
  • Peña, Diego|||0000-0003-3814-589X
  • Mugarza, Aitor|||0000-0002-2698-885X
  • Lechuga, Laura M.|||0000-0001-5187-5358
  • Moreno, Cesar|||0000-0003-2682-211X
Despite the outstanding progress in photonic sensor devices, a major limitation for its application as label-free biosensors for biomedical analysis lies in the surface biofunctionalization step, that is, the reliable immobilization of the biorecognition element onto the sensor surface. Here, we report the integration of bottom-up synthesized nanoporous graphene onto bimodal waveguide interferometric biosensors as an atomically precise biofunctionalization scaffold. This combination leverages the high sensitivity of bimodal waveguide interferometers and the large functional surface area of nanoporous graphene to create highly sensitive, selective, and robust biosensors for the direct immunoassay detection of C-reactive protein (CRP), an inflammatory biomarker widely used in the clinical diagnosis of infections and sepsis. The limit of detection was determined at 3 ng/mL, which is well below the clinical cutoff levels required for the diagnostic detection of CRP in patient samples. This innovative approach holds promise for transforming diagnostics, environmental monitoring, and various fields requiring precise biomolecular detection.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanoporous Graphene Integrated onto Bimodal Waveguide Biosensors for Detection of C-Reactive Protein

  • Lisboa, Bárbara D.
  • Soler, María
  • Singh, Rukmani
  • Castro-Esteban, Jesús
  • Peña, Diego
  • Mugarza, Aitor
  • Lechuga, Laura M.
  • Moreno, César
Despite the outstanding progress in photonic sensor devices, a major limitation for its application as label-free biosensors for biomedical analysis lies in the surface biofunctionalization step, that is, the reliable immobilization of the biorecognition element onto the sensor surface. Here, we report the integration of bottom-up synthesized nanoporous graphene onto bimodal waveguide interferometric biosensors as an atomically precise biofunctionalization scaffold. This combination leverages the high sensitivity of bimodal waveguide interferometers and the large functional surface area of nanoporous graphene to create highly sensitive, selective, and robust biosensors for the direct immunoassay detection of C-reactive protein (CRP), an inflammatory biomarker widely used in the clinical diagnosis of infections and sepsis. The limit of detection was determined at 3 ng/mL, which is well below the clinical cutoff levels required for the diagnostic detection of CRP in patient samples. This innovative approach holds promise for transforming diagnostics, environmental monitoring, and various fields requiring precise biomolecular detection., Main funding source of the work has been the LEGOCHIP project, a FLAG-ERA project funded by the Spanish Research Agency (AEI, ref PCI2019–111890–2). Financial support is also acknowledged from the AMBROSIA project (European Commission, HORIZON-CL4–2022-DIGITAL-EMERGING-01–03, 101093166)., M.S. acknowledges economic support of the Ramon y Cajal Fellowship (RYC2020-029015-I) funded by the AEI/MCIN and the European Union NextGenerationEU/PRTR. CM was supported by Grant RYC2019-028110-I funded by MICIN/AEI/10.13039/501100011033 and by “ESF Investing in your future”, SUBVTC-2022-0010, PID2022-140827OB-I00 funded by MICIU/AEI/10.13039/501100011033 and by FEDER, UE and CNS2023-144257 funded by MICIU/AEI/10.13039/501100011033 and by NextGenerationEU/PRTR. The ICN2 is supported by the Severo Ochoa Centres of Excellence Programme, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033. ICN2 is funded by the CERCA programme (Generalitat de Catalunya). The NanoB2A group is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament de Recerca i Universitats de la Generalitat de Catalunya. D.P. and J.C.E. acknowledge financial support from Spanish MCIN/AEI/10.13039/501100011033 and the European Regional Development Fund (ERDF) through grant PID2022-140845OB-C62, and from Xunta de Galicia (Centro de Investigación do Sistema Universitario de Galicia, 2023-2027, ED431G 2023/03)., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Compact Multichannel Plasmonic Device for Rapid and Versatile Inflammatory Biomarker Analysis

  • Giarola, Juliana Fátima
  • Ramirez-Priego, Patricia
  • Estévez, M. Carmen
  • Lechuga, Laura M.
Plasmonic biosensors have demonstrated versatility across diverse applications, including clinical diagnostics, environmental monitoring, and food analysis. Multiplexed plasmonic biosensors capable of detecting multiple analytes simultaneously have also been developed. However, existing designs face challenges for wide-scale adoption due to bulky designs and expense. A compact multichannel plasmonic biosensor platform is presented for multiplexed detection of up to four biomarkers from one sample distributed via microfluidic channels. The device operates under the Kretschmann configuration for sequential quasi-simultaneous multichannel sensing. Optical performance evaluation demonstrates high sensitivity and a limit of detection (LOD) of 10⁻⁶ RIU across four channels. The biosensing capabilities of the device have been assessed for detecting four inflammatory biomarkers. Customized biofunctionalization of sensor chips ensures inter-channel reproducibility and direct binding detection assays for C-reactive protein (CRP), interleukin-6 (IL-6), procalcitonin (PCT), and pancreatic stone protein (PSP), with sensitivities in the low ng/mL range and negligible cross-reactivity. Recovery testing confirms its feasibility for detecting multiple biomarkers at low concentrations in human serum. The compact, user-friendly design makes this biosensor an attractive tool for multiplexed detection, underscoring its applicability beyond inflammatory-related processes, offering a versatile solution for biomarker analysis in human fluids, and contributing to the decentralization of diagnostics for complex diseases., The authors thank Mehdi Torabi for his contribution to this work. This work was funded by the Ministry of Science and Innovation (MICINN) and the European Union Next Generation (EU/PRTR) (10.13039/ 501100011033) (Grant PDC2021-121325-I00). ICN2 is funded by the CERCA program / Generalitat de Catalunya. The ICN2 is supported by the Severo Ochoa Centres of Excellence program, Grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033. The work has been supported by the European Commission through the Horizon Europe project AMBROSIA (No. 101093166). The NanoB2A group is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament de Recerca i Universitats de la Generalitat de Catalunya (expedient: 2021 SGR 00456)., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed