DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication
Artículo científico (JournalArticle)
Automatic detection of alignment errors in cryo-electron tomography
Supplementary material related to this article can be found online at https://doi.org/10.1016/j.jsb.2024.108153, Cryo-electron tomography is an imaging technique that allows the study of the three-dimensional structure of a wide range of biological samples, from entire cellular environments to purified specimens. This technique collects a series of images from different views of the specimen by tilting the sample stage in the microscope. Subsequently, this information is combined into a three-dimensional reconstruction. To obtain reliable representations of the specimen of study, it is mandatory to define the acquisition geometry accurately. This is achieved by aligning all tilt images to a standard reference scheme. Errors in this step introduce artifacts into the final reconstructed tomograms, leading to loss of resolution and making them unsuitable for detailed sample analysis. This publication presents algorithms for automatically assessing the alignment quality of the tilt series and their classification based on the residual errors provided by the alignment algorithms. If no alignment information is available, a set of algorithms for calculating the residual vectors focused on fiducial markers is also presented. This software is accessible as part of the Xmipp software package and the Scipion framework., The authors acknowledge the financial support from the Ministry of Science, Innovation, and Universities, Spain (BDNS n. 716450) to the Instruct Image Processing Center (I2PC) as part of the Spanish participation in Instruct-ERIC, the European Strategic Infrastructure Project (ESFRI) in the area of Structural Biology. This work was also supported by Grant PID2022-136594NB-I00 funded by MICIU/AEI/10.13039/501100011033 and ‘‘ERDF A way of making Europe’’, by the European Union and Comunidad Autónoma de Madrid, Spain through Grant S2022/BMD-7232. Additional support came from the European Union (EU) and Horizon 2020 through the HighResCells grant (ERC- 2018 - SyG, Proposal: 810057) and from the European Union (EU) and Horizon Europe through the Fragment Screen grant (Proposal: 101094131)., Peer reviewed
Project:
AEI / Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023 PID2022-136594NB-I00
,
EC / H2020 810057
,
EC / HE 101094131
DOI: http://hdl.handle.net/10261/379751, https://api.elsevier.com/content/abstract/scopus_id/85212549286
HANDLE: http://hdl.handle.net/10261/379751, https://api.elsevier.com/content/abstract/scopus_id/85212549286