Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Iterative Application of UMAP-Based Algorithms for Fully Synthetic Healthcare Tabular Data Generation

  • Lázaro, Carla
  • Angulo, Cecilio
Building on a previously developed partially synthetic data generation algorithm utilizing data visualization techniques, this study extends the novel algorithm to generate fully synthetic tabular healthcare data. In this enhanced form, the algorithm serves as an alternative to conventional methods based on Generative Adversarial Networks (GANs) or Variational Autoencoders (VAEs). By iteratively applying the original methodology, the adapted algorithm employs UMAP (Uniform Manifold Approximation and Projection), a dimensionality reduction technique, to validate generated samples through low-dimensional clustering. This approach has been successfully applied to three healthcare domains: prostate cancer, breast cancer, and cardiovascular disease. The generated synthetic data have been rigorously evaluated for fidelity and utility. Results show that the UMAP-based algorithm outperforms GAN- and VAE-based generation methods across different scenarios. In fidelity assessments, it achieved smaller maximum distances between the cumulative distribution functions of real and synthetic data for different attributes. In utility evaluations, the UMAP-based synthetic datasets enhanced machine learning model performance, particularly in classification tasks. In conclusion, this method represents a robust solution for generating secure, high-quality synthetic healthcare data, effectively addressing data scarcity challenges., This research was funded by the European Union Horizon Europe R&I program through the project FLUTE (Grant agreement no.: 101095382). It is also co-funded by the European Union–Next Generation EU funds, through the I+D+i PID2021-122835OBC21 research project ARTIFACTS (MCIN/AEI/10.13039/501000011033) and FEDER “Una manera de hacer Europa”., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Rethinking trust in synthetic health data: lessons from 7 European research initiatives

  • Declerck, Jens
  • Kalra, Dipak
  • Airola, Antti
  • Ali Amer, Ahmed Youssef
  • Chatzichristos, Christos
  • Mañu Pereira, Maria del Mar
  • de Brito Robalo, Bruno M.
  • Ghini, Francesco
  • Gutiérrez Torre, Alberto|||0000-0002-5548-3359
  • Reidel Lojo, Sara Isabel|||0000-0003-1887-9538
Synthetic data generation (SDG) structured health data is increasingly promoted as a solution to longstanding barriers in health data access. It is offering the promise of privacy-preserving data reuse for research, innovation, and policy. Despite rapid technical advances, the adoption of synthetic health data in real-world settings remains limited. Shaped by challenges around data quality, representativeness, infrastructure readiness, trust, and legal uncertainty, this viewpoint draws on experiences from 7 European research initiatives within the HealthData4EU cluster to reflect on how SDG is being operationalized in practice. It synthesizes cross-project insights to highlight recurring methodological and governance tensions and to examine their implications for trust and responsible use. The analysis argues that trustworthy SDG cannot be achieved through technical optimization alone but requires alignment between evaluation practices, upstream data stewardship, regulatory clarity, and sustained stakeholder engagement. Addressing these conditions is essential for moving synthetic data from experimental pilots toward a credible and sustainable component of European health research ecosystems., This paper was funded by the Innovative Health Initiative through the SYNTHIA project. The study draws on insights from 7 research projects that form part of the HealthData4EU cluster. Projects within the cluster and their funding sources are as follows. SYNTHEMA, PHASE IV AI, SECURED, FLUTE, and AISym4MED are funded by the Horizon Europe program. PHEMS is funded by Horizon Europe and UK Research and Innovation. SYNTHIA is funded through the Innovative Health Initiative., Peer Reviewed, Article signat per 18 autors/es: Jens Declerck 1,2, MSc; Dipak Kalra 1, Prof Dr; Antti Airola 3; Ahmed Youssef Ali Amer 4; Christos Chatzichristos 5; Maria del Mar Mañu Pereira 6; Bruno M. de Brito Robalo 7; Francesco Ghini 8; Alberto Gutierrez-Torre 9; Sem Hoogteijling 10; Susanne Hultsch 11; Jan Ramon 12; Sara Reidel 13,14; Francesco Regazzoni 15,16; Luís Silva 17; Inês Silveira 17; Tsekeridou Sofia 18, PhD; Christophe Maes 1,2 / 1- The European Institute for Innovation through Health Data, Oosterzele, Belgium; 2- Unit of Medical Informatics and Statistics, Department of Public Health and Primary Care, The University of Ghent, Ghent, Belgium; 3- Department of Computing, University of Turku, Turku, Finland; 4- Innovative Medicine, Johnson & Johnson, Beerse, Belgium; 5- Department of Electrical Engineering, KU Leuven, Leuven, Belgium; 6- University Hospital Vall d'Hebron, Barcelona, Spain; 7- Department of Obstetrics and Gynaecology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands; 8- Laboratory of Translational Research, Reggio Emilia, Italy; 9- Barcelona Supercomputing Center, Barcelona, Catalonia, Spain; 10- Department of Neurology and Neurosurgery, University Medical Center Utrecht Brain Center, Utrecht, The Netherlands; 11- VEIL.AI, Helsinki, Finland; 12- Institut national de recherche en sciences et technologies du numérique, Lille, France; 13- Vall d'Hebron Research Institute, University Hospital Vall d'Hebron, Barcelona, Spain; 14- BarcelonaTech (UPC), Universitat Politècnica de Catalunya, Barcelona, Spain; 15- University of Amsterdam, Amsterdam, The Netherlands; 16- Università della Svizzera italiana, Lugano, Ticino, Switzerland; 17- Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics, NOVA School of Science and Technology, Caparica, Portugal; 18- Netcompany BELUX, Athens, Greece
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

3D-StyleGAN2-ADA: Volumetric synthesis of realistic prostate T2W MRI

  • Lezcano Giardina, Claudia Patricia|||0000-0002-2670-7069
  • Vilaplana Besler, Verónica|||0000-0001-6924-9961
This work investigates the extension of StyleGAN2-ADA to three-dimensional prostate T2-weighted (T2W) MRI generation. The architecture is adapted to operate on 3D anisotropic volumes, enabling stable training at a clinically relevant resolution of 256×256×24, where a baseline 3D-StyleGAN fails to converge. Quantitative evaluation using Fréchet Inception Distance (FID), Kernel Inception Distance (KID), and generative Precision–Recall metrics demonstrates substantial improvements over a 3D-StyleGAN baseline. Specifically, FID decreased from 114.2 to 27.3, while generative Precision increased from 0.22 to 0.82, indicating markedly improved fidelity and alignment with the real data distribution. Beyond generative metrics, the synthetic volumes were evaluated through radiomic feature analysis and downstream prostate segmentation. Synthetic data augmentation resulted in segmentation performance comparable to real-data training, supporting that volumetric generation preserves anatomically relevant structures, while multivariate radiomic analyses showed strong global feature alignment between real and synthetic volumes. These findings indicate that a 3D extension of StyleGAN2-ADA enables stable high-resolution volumetric prostate MRI synthesis while preserving anatomically coherent structure and global radiomic characteristics., This work was supported by the European project Federated Learning and mUlti-party computation Techniques for prostatE cancer (HORIZON-101095382-FLUTE), the Spanish Research Agency (AEI) under project PID2023-148614OB-I00 funded by MICIU/AEI/10.13039/501100011033 and by FEDER, EU, and the FPI-Ministerio PRE-2021-098481 grant., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Iterative application of UMAP-based algorithms for fully synthetic healthcare tabular data generation

  • Lázaro Trilles, Carla|||0009-0003-4308-5032
  • Angulo Bahón, Cecilio|||0000-0001-9589-8199
Building on a previously developed partially synthetic data generation algorithm utilizing data visualization techniques, this study extends the novel algorithm to generate fully synthetic tabular healthcare data. In this enhanced form, the algorithm serves as an alternative to conventional methods based on Generative Adversarial Networks (GANs) or Variational Autoencoders (VAEs). By iteratively applying the original methodology, the adapted algorithm employs UMAP (Uniform Manifold Approximation and Projection), a dimensionality reduction technique, to validate generated samples through low-dimensional clustering. This approach has been successfully applied to three healthcare domains: prostate cancer, breast cancer, and cardiovascular disease. The generated synthetic data have been rigorously evaluated for fidelity and utility. Results show that the UMAP-based algorithm outperforms GAN- and VAE-based generation methods across different scenarios. In fidelity assessments, it achieved smaller maximum distances between the cumulative distribution functions of real and synthetic data for different attributes. In utility evaluations, the UMAP-based synthetic datasets enhanced machine learning model performance, particularly in classification tasks. In conclusion, this method represents a robust solution for generating secure, high-quality synthetic healthcare data, effectively addressing data scarcity challenges., This research was funded by the European Union Horizon Europe R&I program through the project FLUTE (Grant agreement no.: 101095382). It is also co-funded by the European Union–Next Generation EU funds, through the I+D+i PID2021-122835OBC21 research project ARTIFACTS (MCIN/AEI/10.13039/501000011033) and FEDER “Una manera de hacer Europa”., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Anatomically guided 3D diffusion models for synthetic prostate MRI generation

  • Lezcano Giardina, Claudia Patricia|||0000-0002-2670-7069
  • Vila Bagaria, Sígrid|||0009-0002-9348-7235
  • Albornés Sotomayor, Carlos
  • Pardàs Feliu, Montse|||0000-0002-5861-6356
  • Vilaplana Besler, Verónica|||0000-0001-6924-9961
Automated analysis of prostate MRI has the potential to improve cancer diagnosis, but its development is limited by the scarcity of large, annotated datasets. This limitation stems not only from the laborintensive nature of expert annotation but also from strict patient privacy constraints that restrict data sharing. Diffusion-based generative models show promise for data augmentation, but often lack anatomical awareness, limiting their ability to produce realistic lesions and fully coherent anatomy. To address this, we propose an anatomically guided 3D diffusion model that synthesizes T2-weighted prostate MRI conditioned on region masks (prostate zones and lesions). In addition, our method leverages FiLM-based label conditioning to enable class-specific generation for clinically significant prostate cancer. We evaluate our approach using both standard image synthesis metrics and performance of downstream region segmentation tasks. In particular, we show that nnU-Net models trained on synthetic and hybrid datasets match the performance of models trained on the full set of real annotations, despite using only 17% of the original manual annotations. Furthermore, radiomic feature analysis demonstrates that descriptors from synthetic images closely align with those from real MRI, confirming structural plausibility. These results highlight the potential of anatomically conditioned diffusion models to generate high-quality synthetic data, reduce the annotation burden, and provide a scalable solution to develop deep learning models in prostate MRI., This work was supported by the European project Federated Learning and mUlti-party computation Techniques for prostatE cancer (HORIZON101095382-FLUTE), the Spanish Research Agency (AEI) under project PID2023- 148614OB-I00 research project funded by MICIU/AEI /10.13039/501100011033 and by FEDER, EU, the FPI-Ministerio PRE-2021-098481 grant and the predoctoral program AGAUR-FI ajuts (2025 FI-1 00076) Joan Oró backed by the Secretariat of Universities and Research of the Department of Research and Universities of the Generalitat of Catalonia, as well as the European Social Plus Fund., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Using UMAP for partially synthetic healthcare tabular data generation and validation

  • Lázaro Trilles, Carla|||0009-0003-4308-5032
  • Angulo Bahón, Cecilio|||0000-0001-9589-8199
In healthcare, vast amounts of data are increasingly collected through sensors for smart health applications and patient monitoring or diagnosis. However, such medical data often comprise sensitive patient information, posing challenges regarding data privacy, and are resource-intensive to acquire for significant research purposes. In addition, the common case of lack of information due to technical issues, transcript errors, or differences between descriptors considered in different health centers leads to the need for data imputation and partial data generation techniques. This study introduces a novel methodology for partially synthetic tabular data generation, designed to reduce the reliance on sensor measurements and ensure secure data exchange. Using the UMAP (Uniform Manifold Approximation and Projection) visualization algorithm to transform the original, high-dimensional reference data set into a reduced-dimensional space, we generate and validate synthetic values for incomplete data sets. This approach mitigates the need for extensive sensor readings while addressing data privacy concerns by generating realistic synthetic samples. The proposed method is validated on prostate and breast cancer data sets, showing its effectiveness in completing and augmenting incomplete data sets using fully available references. Furthermore, our results demonstrate superior performance in comparison to state-of-the-art imputation techniques. This work makes a dual contribution by not only proposing an innovative method for synthetic data generation, but also studying and establishing a formal framework to understand and solve synthetic data generation and imputation problems in sensor-driven environments., This research was funded by the European Union Horizon Europe R&I program through the project FLUTE (Grant agreement no.: 101095382). It is also co-funded by the European Union–Next Generation EU funds, through the I+D+i PID2021-122835OBC21 research project ARTIFACTS (MCIN/AEI/10.13039/501000011033) and FEDER “Una manera de hacer Europa”., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Rethinking trust in synthetic health data: lessons from 7 European research initiatives

  • Declerck, Jens
  • Kalra, Dipak
  • Airola, Antti
  • Ali Amer, Ahmed Youssef
  • Chatzichristos, Christos
  • Mañu Pereira, Maria del Mar
  • de Brito Robalo, Bruno M.
  • Ghini, Francesco
  • Gutiérrez Torre, Alberto
  • Reidel Lojo, Sara Isabel
Synthetic data generation (SDG) structured health data is increasingly promoted as a solution to longstanding barriers in health data access. It is offering the promise of privacy-preserving data reuse for research, innovation, and policy. Despite rapid technical advances, the adoption of synthetic health data in real-world settings remains limited. Shaped by challenges around data quality, representativeness, infrastructure readiness, trust, and legal uncertainty, this viewpoint draws on experiences from 7 European research initiatives within the HealthData4EU cluster to reflect on how SDG is being operationalized in practice. It synthesizes cross-project insights to highlight recurring methodological and governance tensions and to examine their implications for trust and responsible use. The analysis argues that trustworthy SDG cannot be achieved through technical optimization alone but requires alignment between evaluation practices, upstream data stewardship, regulatory clarity, and sustained stakeholder engagement. Addressing these conditions is essential for moving synthetic data from experimental pilots toward a credible and sustainable component of European health research ecosystems., This paper was funded by the Innovative Health Initiative through the SYNTHIA project. The study draws on insights from 7 research projects that form part of the HealthData4EU cluster. Projects within the cluster and their funding sources are as follows. SYNTHEMA, PHASE IV AI, SECURED, FLUTE, and AISym4MED are funded by the Horizon Europe program. PHEMS is funded by Horizon Europe and UK Research and Innovation. SYNTHIA is funded through the Innovative Health Initiative., Peer Reviewed, Article signat per 18 autors/es: Jens Declerck 1,2, MSc; Dipak Kalra 1, Prof Dr; Antti Airola 3; Ahmed Youssef Ali Amer 4; Christos Chatzichristos 5; Maria del Mar Mañu Pereira 6; Bruno M. de Brito Robalo 7; Francesco Ghini 8; Alberto Gutierrez-Torre 9; Sem Hoogteijling 10; Susanne Hultsch 11; Jan Ramon 12; Sara Reidel 13,14; Francesco Regazzoni 15,16; Luís Silva 17; Inês Silveira 17; Tsekeridou Sofia 18, PhD; Christophe Maes 1,2 / 1- The European Institute for Innovation through Health Data, Oosterzele, Belgium; 2- Unit of Medical Informatics and Statistics, Department of Public Health and Primary Care, The University of Ghent, Ghent, Belgium; 3- Department of Computing, University of Turku, Turku, Finland; 4- Innovative Medicine, Johnson & Johnson, Beerse, Belgium; 5- Department of Electrical Engineering, KU Leuven, Leuven, Belgium; 6- University Hospital Vall d'Hebron, Barcelona, Spain; 7- Department of Obstetrics and Gynaecology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands; 8- Laboratory of Translational Research, Reggio Emilia, Italy; 9- Barcelona Supercomputing Center, Barcelona, Catalonia, Spain; 10- Department of Neurology and Neurosurgery, University Medical Center Utrecht Brain Center, Utrecht, The Netherlands; 11- VEIL.AI, Helsinki, Finland; 12- Institut national de recherche en sciences et technologies du numérique, Lille, France; 13- Vall d'Hebron Research Institute, University Hospital Vall d'Hebron, Barcelona, Spain; 14- BarcelonaTech (UPC), Universitat Politècnica de Catalunya, Barcelona, Spain; 15- University of Amsterdam, Amsterdam, The Netherlands; 16- Università della Svizzera italiana, Lugano, Ticino, Switzerland; 17- Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics, NOVA School of Science and Technology, Caparica, Portugal; 18- Netcompany BELUX, Athens, Greece, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

3D-StyleGAN2-ADA: Volumetric synthesis of realistic prostate T2W MRI

  • Lezcano Giardina, Claudia Patricia
  • Vilaplana Besler, Verónica
This work investigates the extension of StyleGAN2-ADA to three-dimensional prostate T2-weighted (T2W) MRI generation. The architecture is adapted to operate on 3D anisotropic volumes, enabling stable training at a clinically relevant resolution of 256×256×24, where a baseline 3D-StyleGAN fails to converge. Quantitative evaluation using Fréchet Inception Distance (FID), Kernel Inception Distance (KID), and generative Precision–Recall metrics demonstrates substantial improvements over a 3D-StyleGAN baseline. Specifically, FID decreased from 114.2 to 27.3, while generative Precision increased from 0.22 to 0.82, indicating markedly improved fidelity and alignment with the real data distribution. Beyond generative metrics, the synthetic volumes were evaluated through radiomic feature analysis and downstream prostate segmentation. Synthetic data augmentation resulted in segmentation performance comparable to real-data training, supporting that volumetric generation preserves anatomically relevant structures, while multivariate radiomic analyses showed strong global feature alignment between real and synthetic volumes. These findings indicate that a 3D extension of StyleGAN2-ADA enables stable high-resolution volumetric prostate MRI synthesis while preserving anatomically coherent structure and global radiomic characteristics., This work was supported by the European project Federated Learning and mUlti-party computation Techniques for prostatE cancer (HORIZON-101095382-FLUTE), the Spanish Research Agency (AEI) under project PID2023-148614OB-I00 funded by MICIU/AEI/10.13039/501100011033 and by FEDER, EU, and the FPI-Ministerio PRE-2021-098481 grant., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Anatomically guided 3D diffusion models for synthetic prostate MRI generation

  • Lezcano Giardina, Claudia Patricia
  • Vila Bagaria, Sígrid
  • Albornés Sotomayor, Carlos
  • Pardàs Feliu, Montse
  • Vilaplana Besler, Verónica
Automated analysis of prostate MRI has the potential to improve cancer diagnosis, but its development is limited by the scarcity of large, annotated datasets. This limitation stems not only from the laborintensive nature of expert annotation but also from strict patient privacy constraints that restrict data sharing. Diffusion-based generative models show promise for data augmentation, but often lack anatomical awareness, limiting their ability to produce realistic lesions and fully coherent anatomy. To address this, we propose an anatomically guided 3D diffusion model that synthesizes T2-weighted prostate MRI conditioned on region masks (prostate zones and lesions). In addition, our method leverages FiLM-based label conditioning to enable class-specific generation for clinically significant prostate cancer. We evaluate our approach using both standard image synthesis metrics and performance of downstream region segmentation tasks. In particular, we show that nnU-Net models trained on synthetic and hybrid datasets match the performance of models trained on the full set of real annotations, despite using only 17% of the original manual annotations. Furthermore, radiomic feature analysis demonstrates that descriptors from synthetic images closely align with those from real MRI, confirming structural plausibility. These results highlight the potential of anatomically conditioned diffusion models to generate high-quality synthetic data, reduce the annotation burden, and provide a scalable solution to develop deep learning models in prostate MRI., This work was supported by the European project Federated Learning and mUlti-party computation Techniques for prostatE cancer (HORIZON101095382-FLUTE), the Spanish Research Agency (AEI) under project PID2023- 148614OB-I00 research project funded by MICIU/AEI /10.13039/501100011033 and by FEDER, EU, the FPI-Ministerio PRE-2021-098481 grant and the predoctoral program AGAUR-FI ajuts (2025 FI-1 00076) Joan Oró backed by the Secretariat of Universities and Research of the Department of Research and Universities of the Generalitat of Catalonia, as well as the European Social Plus Fund., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Iterative application of UMAP-based algorithms for fully synthetic healthcare tabular data generation

  • Lázaro Trilles, Carla
  • Angulo Bahón, Cecilio
Building on a previously developed partially synthetic data generation algorithm utilizing data visualization techniques, this study extends the novel algorithm to generate fully synthetic tabular healthcare data. In this enhanced form, the algorithm serves as an alternative to conventional methods based on Generative Adversarial Networks (GANs) or Variational Autoencoders (VAEs). By iteratively applying the original methodology, the adapted algorithm employs UMAP (Uniform Manifold Approximation and Projection), a dimensionality reduction technique, to validate generated samples through low-dimensional clustering. This approach has been successfully applied to three healthcare domains: prostate cancer, breast cancer, and cardiovascular disease. The generated synthetic data have been rigorously evaluated for fidelity and utility. Results show that the UMAP-based algorithm outperforms GAN- and VAE-based generation methods across different scenarios. In fidelity assessments, it achieved smaller maximum distances between the cumulative distribution functions of real and synthetic data for different attributes. In utility evaluations, the UMAP-based synthetic datasets enhanced machine learning model performance, particularly in classification tasks. In conclusion, this method represents a robust solution for generating secure, high-quality synthetic healthcare data, effectively addressing data scarcity challenges., This research was funded by the European Union Horizon Europe R&I program through the project FLUTE (Grant agreement no.: 101095382). It is also co-funded by the European Union–Next Generation EU funds, through the I+D+i PID2021-122835OBC21 research project ARTIFACTS (MCIN/AEI/10.13039/501000011033) and FEDER “Una manera de hacer Europa”., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Using UMAP for partially synthetic healthcare tabular data generation and validation

  • Lázaro Trilles, Carla
  • Angulo Bahón, Cecilio
In healthcare, vast amounts of data are increasingly collected through sensors for smart health applications and patient monitoring or diagnosis. However, such medical data often comprise sensitive patient information, posing challenges regarding data privacy, and are resource-intensive to acquire for significant research purposes. In addition, the common case of lack of information due to technical issues, transcript errors, or differences between descriptors considered in different health centers leads to the need for data imputation and partial data generation techniques. This study introduces a novel methodology for partially synthetic tabular data generation, designed to reduce the reliance on sensor measurements and ensure secure data exchange. Using the UMAP (Uniform Manifold Approximation and Projection) visualization algorithm to transform the original, high-dimensional reference data set into a reduced-dimensional space, we generate and validate synthetic values for incomplete data sets. This approach mitigates the need for extensive sensor readings while addressing data privacy concerns by generating realistic synthetic samples. The proposed method is validated on prostate and breast cancer data sets, showing its effectiveness in completing and augmenting incomplete data sets using fully available references. Furthermore, our results demonstrate superior performance in comparison to state-of-the-art imputation techniques. This work makes a dual contribution by not only proposing an innovative method for synthetic data generation, but also studying and establishing a formal framework to understand and solve synthetic data generation and imputation problems in sensor-driven environments., This research was funded by the European Union Horizon Europe R&I program through the project FLUTE (Grant agreement no.: 101095382). It is also co-funded by the European Union–Next Generation EU funds, through the I+D+i PID2021-122835OBC21 research project ARTIFACTS (MCIN/AEI/10.13039/501000011033) and FEDER “Una manera de hacer Europa”., Peer Reviewed, Postprint (published version)
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

The Role of Radiomics in the Prediction of Clinically Significant Prostate Cancer in the PI-RADS v2 and v2.1 Era, A Systematic Review

  • Antolín, Andreu|||0000-0001-6973-4246
  • Roson, Nuria|||0000-0001-6751-7491
  • Mast, Richard|||0000-0001-6005-800X
  • Arce, Javier
  • Almodovar, Ramon
  • Cortada, Roger
  • Maceda, Almudena
  • Escobar, Manuel|||0000-0002-3794-2224
  • Trilla Herrera, Enrique|||0000-0001-9401-0872
  • Morote Robles, Juan|||0000-0002-2168-323X
There is still an overdiagnosis of indolent prostate cancer (iPCa) lesions using the Prostate Imaging-Reporting and Data System (PI-RADS), and radiomics has emerged as a promising tool to improve the diagnosis of clinically significant prostate cancer (csPCa) lesions. However, the current state and applicability of radiomics remains a challenge. This systematic review aims at evaluating the evidence of handcrafted and deep radiomics in differentiating lesions at risk of having csPCa from those with iPCa and benign pathology. The review highlighted a good performance of radiomics but without significant differences with radiologist assessment (PI-RADS), as well as several methodological limitations in the reported studies, which might induce bias. Future studies should improve methodological aspects to ensure the clinical applicability of radiomics, especially the need for clinical prospective studies and the comparison with PI-RADS. Early detection of clinically significant prostate cancer (csPCa) has substantially improved with the latest PI-RADS versions. However, there is still an overdiagnosis of indolent lesions (iPCa), and radiomics has emerged as a potential solution. The aim of this systematic review is to evaluate the role of handcrafted and deep radiomics in differentiating lesions with csPCa from those with iPCa and benign lesions on prostate MRI assessed with PI-RADS v2 and/or 2.1. The literature search was conducted in PubMed, Cochrane, and Web of Science databases to select relevant studies. Quality assessment was carried out with Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2), Radiomic Quality Score (RQS), and Checklist for Artificial Intelligence in Medical Imaging (CLAIM) tools. A total of 14 studies were deemed as relevant from 411 publications. The results highlighted a good performance of handcrafted and deep radiomics methods for csPCa detection, but without significant differences compared to radiologists (PI-RADS) in the few studies in which it was assessed. Moreover, heterogeneity and restrictions were found in the studies and quality analysis, which might induce bias. Future studies should tackle these problems to encourage clinical applicability. Prospective studies and comparison with radiologists (PI-RADS) are needed to better understand its potential.