Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Uncertainty-aware electrification of university campuses: Matching demand with renewable generation for zero emissions

  • Berna-Escriche, César|||0000-0002-2097-5089
  • Álvarez-Piñeiro, Lucas|||0000-0002-9450-2479
  • Bastida-Molina, Paula|||0000-0003-3516-0090
  • Blanco-Muelas, David|||0000-0003-2958-0558
[EN] Urban decarbonization requires robust methodologies to match electrified demand with on-site renewable generation under operational variability. University campuses are particularly well-suited testing environments, as their predominantly daytime demand profiles favor solar photovoltaic (PV) self-consumption. However, most campus-scale studies adopt deterministic approaches and do not explicitly quantify the impact of uncertainty in solar generation and demand, which can significantly affect system performance and design. This study proposes a structured and transferable methodology for campus decarbonization, integrating high-resolution hourly demand analysis, PV generation modeling, electrification measures, and uncertainty quantification within a Best Estimate Plus Uncertainty (BEPU) framework using Wilks' non-parametric tolerance intervals. The approach is applied to the ETSII buildings at the Universitat Polite`cnica de Vale`ncia (UPV), within Valencia's climate-neutrality strategy. For a case study with similar to 3 GWh annual demand and 1.3 MWp PV capacity, results indicate that solar PV alone can supply about 70% of annual demand, with self-consumption levels of 67-69% and overall self-sufficiency near 50%. Adding a 1 MW / 4 MWh battery increases self-consumption above 95% and selfsufficiency to similar to 65%, despite storage losses. The BEPU/Wilks framework provides statistically robust performance bounds, supporting reliable PV-storage sizing. The methodology provides a robust and scalable framework for planning the decarbonization of urban areas and university campuses., This work was supported by: the URBISOS project (CIGE/2024/193) funded by the Generalitat Valenciana; a grant of the Catedra de Transicion Energetica Urbana-funded by Ajuntament de Valencia-Valencia Innovation Capital Foundation, and OAM Valencia Sostenible; and the LIFE23-CET-RESSKILL project, financed by the European Union under the LIFE Programme (Grant Agreement No. 101167278).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Field thermal and energy performance of a closed-platform floating PV system on a tropical hydroelectric reservoir

  • Lara-Vargas, Fabian Alonso
  • Isaac-Milan, Idi Amin
  • Castro-Morales, Amarilis
  • Vargas-Salgado, Carlos|||0000-0002-9259-8374
[EN] FPV systems are expected to outperform ground-mounted PV (GPV) through water cooling, unconfirmed for closed-platform FPV in tropical reservoirs, where water temperature can exceed ambient air temperature. Platform type was isolated using a co-located, identical-hardware GPV reference, monitored for 12 months at hourly resolution in a Colombian hydroelectric reservoir. The GPV system generated 1407 kWh/kWp per year, compared to 1382 kWh/kWp for the FPV system, representing a shortfall of 25 kWh/kWp (1.75%), of which 12.4% is due to resistive losses in the FPV system¿s longer wiring and the remaining 87.6% to thermal loss. The FPV modules operated at higher temperatures than the GPV modules during 70.5% of the monitored hours, at a mean differential of +1.17 ¿C. Water beneath the platform averaged 30.98 ¿C, above ambient throughout. Wind speed showed no cooling effect on the temperature difference between the FPV and GPV modules (Spearman: 0.090); airflow beneath the floating platform was not measured directly, and it is possible that the irregular bathymetry (depth of 6 to 38 m) limited renewal of the surface layer. Closed-platform FPV over warm water can act as a net heat source. The 25 kWh/kWp gap equals 567 USD/year (171 kWp) or 82,725 USD/25 years (1 MW), useful for prefeasibility assessments., One of the authors, F.A.L.V., was awarded a scholarship by the Universidad Pontificia Bolivariana through Act 58 of October 25, 2023, for studies at the Universitat Politecnica de Valencia. This work was also supported by: a grant of the Catedra de Transicion Energetica Urbana funded by Ajuntament de Val`encia Valencia Innovation Capital and Fundacio Valencia Clima i Energia; and the project Renewable Energy System Integration and Digitalization Upskilling Initiative for Sustainable Buildings RESSKILL financed by the European Union under Grant Agreement No. 101167278.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Multistage symbolic optimization for predictive thermal modeling of bifacial photovoltaic systems with solar tracking in tropical climates

  • Lara-Vargas, Fabian Alonso
  • Águila-León, Jesús
  • Sanchis-Gomez, Carlos
  • Vargas-Salgado, Carlos|||0000-0002-9259-8374
[EN] Accurate prediction of module temperature in bifacial photovoltaic (PV) systems equipped with single-axis solar tracking is critical for optimizing energy yield and mitigating thermal stress, particularly in tropical climates. However, existing empirical and data-driven approaches often lack physical interpretability or fail to adequately represent the nonlinear thermal behavior of operating PV modules. This study presents a novel multistage symbolic optimization (MSO) framework for predictive thermal modeling that addresses these limitations. The proposed two-level hierarchical approach first derives a physically interpretable symbolic equation using genetic algorithms (GA), followed by a second corrective symbolic regression stage in which GA and Alpha Evolution (AE) are evaluated as competing optimizers. This work presents a novel application of the AE algorithm to symbolic regression in PV thermal modeling. The methodology is validated using one year of high-resolution (5-min) operational data from a utility-scale bifacial PV plant with solar tracking in Colombia. The MSO-AE model achieved an R2 of 0.9439, an RMSE of 3.18 degrees C, and an MAE of 2.01 degrees C, outperforming the MSO-GA benchmark by 7.3% in MAE and 6.5% in RMSE, and surpassing recent single-stage symbolic regression models by 3.7-20%, while preserving closed-form, interpretable expressions suitable for real-time control applications. A field-derived heating coefficient of 0.034 degrees C/(W/m2) was identified. Observations show module temperatures exceeding 70 degrees C between 14:00 and 16:00, reducing electrical efficiency to 17.31%, corresponding to a 12.1% loss relative to standard test conditions. This thermal degradation resulted in average economic losses of USD 110.7 per hour during peak periods and an annual energy loss of 6738.6 MWh, equivalent to USD 336,929 at a benchmark electricity price of USD 50/MWh. These results define economic thresholds for thermal management investments in bifacial PV systems operating in tropical environments., FALV acknowledges the scholarship awarded by the Universidad Pontificia Bolivariana through RR No. 58 (October 25, 2023) to pursue studies at the Universitat Politecnica de Valencia. This work was supported by the Vicerrectorado de Investigacion de la Universitat Politecnica de Valencia through the PAID-11-25 program; the Catedra de Transicion Energetica Urbana, funded by the Ajuntament de Valencia-Valencia Innovation Capital and the Fundacio Valencia Clima i Energia; and the project "Renewable Energy System Integration and Digitalization Upskilling Initiative for Sustainable Buildings", financed by the European Union under Grant Agreement No. 101167278. JAL acknowledges support from the PROSNII 2025 program of the University of Guadalajara. CSG received support from the Valencian Innovation Agency through the European Regional Development Fund (ERDF) 2021-2026.The authors would like to thank Atlantica Sustainable SAS and Engineer Edison Ortega for their valuable support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Statistical energy-based sizing of electric vehicle charging infrastructure for workplace parking facilities: case study of Polytechnic University of Valencia, Spain

  • Blanco-Muelas, David|||0000-0003-2958-0558
  • Bastida-Molina, Paula|||0000-0003-3516-0090
  • Berna-Escriche, César|||0000-0002-2097-5089
  • Álvarez-Piñeiro, Lucas|||0000-0002-9450-2479
  • Montagud- Montalvá, Carla|||0000-0002-7118-6119
[EN] The accelerating electrification of transport is a cornerstone of global decarbonization strategies, yet it poses challenges for energy systems dominated by intermittent renewable sources. In this context, workplace parking facilities offer an opportunity to integrate Electric Vehicle (EV) charging with on-site renewable generation, benefiting from extended dwell times and predictable user behavior. This study proposes a scalable methodology for the characterization and optimal sizing of EV charging infrastructure integrated with renewable energy sources, explicitly accounting for uncertainty in vehicle characteristics, user behavior, mobility patterns, and solar generation. The methodology combines stochastic demand modeling with a Best Estimate Plus Uncertainty (BEPU) framework and Wilks¿ order statistics to derive confidence bounds for energy demand, peak power requirements, and infrastructure sizing. It is applied to a large underground parking facility serving a research campus at the Polytechnic University of Valencia (UPV), accommodating over 600 vehicles and supported by up to 0.6 MW of rooftop and canopy-mounted PhotoVoltaic (PV) generation. Results show that modeling commuting patterns and occupancy reduces annual charging demand estimates to 1200¿1580 MWh. Although the PV system can theoretically generate energy equivalent to 80% of the annual charging demand, temporal mismatches between generation and load limit direct self-consumption without storage. The analysis shows that moderate charging power (7.4 kW) combined with smart charging can reduce infrastructure requirements. Battery energy storage markedly improves self-consumption, demand coverage, and grid interaction, particularly under favorable seasonal conditions. The framework supports planning resilient, cost-effective, renewable-driven EV charging systems in institutional and urban environments., This is an extended and updated version of a paper originally presented at the 20th Conference on Sustainable Development of Energy, Water and Environment Systems (SDEWES 2025) held in Dubrovnik, Croatia, over the period 5th to 10th October 2025 (denoted then as paper SDEWES2025.0341 SS7 and entitled: Dimensioning electric vehicle charging points for university campus decarbonization: Application to a parking lot of the Polytechnic University of Valencia). This work was supported by: a grant of the C¿ atedra de Transicion ¿ Energ¿etica Urbana- funded by Ajuntament de Val`encia-Valencia Innovation Capital Foundation, and OAM Valencia Sostenible; and the LIFE23-CET-RESSKILL project, financed by the European Union under the LIFE Programme (Grant Agreement No. 101167278).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Optimising the Design of Solar Photovoltaic Cantilevers on Building Façades to Enhance Energy Efficiency

  • Martinez-Rodriguez, Lucas Rodolfo
  • Guillén Guillamón, Ignacio Enrique|||0000-0001-5546-1486
  • Bastida-Molina, Paula|||0000-0003-3516-0090
  • Jara-Calabuig, Aaron|||0000-0002-9509-063X
  • Gómez-Navarro, Tomás|||0000-0001-6114-2414
[EN] In dense urban areas, limited available space constrains the deployment of renewable energy systems, motivating alternative solutions. Solar photovoltaic cantilevers on building fa & ccedil;ades offer a promising approach, generating electricity and shading that enhance building energy efficiency. A methodology is proposed to determine the optimal tilt angle, considering both electricity generation and shading-related energy savings. The method is applied to a university building in a Mediterranean climate to evaluate performance under realistic conditions. Results indicate that the optimal photovoltaic cantilever reduces cooling demand by 7% and increases heating demand by 5%, supplies 14% of the building's electricity with a 4% surplus, and can reduce overall electricity consumption by 16-20%. Although focused on a specific case, the findings support broader applications of this approach and highlight its potential as a spatially efficient strategy for advancing energy sustainability in urban buildings., This research was funded by the Yo Investigo program of NextGenerationEU and the Universitat Politecnica de Valencia (UPV); and by the Catedra de Transicion Energetica Urbana, funded by Ajuntament de Valencia and Valencia Sostenible. This work was also supported by the European Union under Grant Agreement No. 101167278-LIFE23-CET-RESSKILL, co-funded by the European Union. Views and opinions expressed are, however, those of the author(s) only and do not necessarily reflect those of the European Union or CINEA. Neither the European Union nor the granting authority can be held responsible for them.