Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Self-referenced carrier frequency offset interferogram correction for distributed sensing using dual-comb systems

  • Romero-Barrueco, A.
  • Escobar-Vera, C.
  • Quevedo-Galán, C.
  • Rosado, A.
  • Mateu-Comas, J.
  • Martín-Lopez, S.
  • González-Herraez, M.
  • Esquivias, I.
  • Fernández-Ruiz, M. R.
10 pages, 16 figures, Dual-comb interferometry (DCI) has become a key tool in an ever-increasing number of applications, including precision spectroscopy, high-resolution ranging, and distributed optical fiber sensing. These techniques benefit from the ability of dual frequency combs (DFC) to retrieve complex-valued information over broad bandwidths with high spectral resolution and accuracy, and without the need for moving parts. However, the long-term coherence required for accurate time-domain analysis is often compromised by carrier frequency offset (CFO), which introduces phase drifts and spectral misalignment between successive interferograms. Although a wide number of CFO correction algorithms and procedures have been reported in the literature, they are generally valid for completely static measurement applications like spectroscopy, or in applications where sharp temporal features are present in the interferogram. Therefore, these methods prove inadequate in emerging applications of DCI that involve time-varying interferograms or where the temporal response has no clear signature, such as distributed optical fiber sensing. In this work, we present a self-referenced spectral-domain CFO compensation method suitable for distributed sensing systems, initially validated in a spectroscopy configuration. The technique has been refined and extended to support distributed fiber-optic measurements using DFCs generated from various laser sources. The proposed correction enables substantial improvements in signal integrity, effectively restoring the additive-noise-limited regime from the previously phase-noise-dominated scenario. This transition represents a key step toward fully coherent data recovery, ensuring stable averaging performance and reliable spectral interpretation in both spectroscopy and distributed fiber sensing experiments., The work of M. R. Fernández-Ruiz was supported by MCIN/AEI/10.13039/501100011033 and European Union Next Generation EU/PRTR under Grant RYC2021-032167-I. This work was supported in part by the Spanish MCIN/AEI/10.13039/501100011033 and the European Union Next Generation EU/PRTR Program under Grant PSI: Reference PLEC2021-007875 and Grant REMO Reference CPP2021-008869, in part by Spanish MCIN/AEI/10.13039/501100011033 and FEDER Una manera de hacer Europa under Grant PRECISION: Reference PID2021-128000OB-C22, Grant MOTION: Reference PID2022-140963OA-I00, Reference PID2021-1234590BC21, and Reference TED2021-131957B-100, in part by European Innovation Council under Grant SAFE: Reference 101098992, Grant SUBMERSE: Reference 101095055, and Grant ECSTATIC: Reference 101189595, and in part by MCIN/AEI/10.13039/501100011033 under Grant SEASNAKE+ Reference PCI2023-145978-2 of the CETPartnership 2022 joint call.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Phase-Sensitive Symmetric Dual-Comb Spectroscopy

  • Mateu-Comas, Julia
  • Romero-Barrueco, Alonso
  • Soriano-Amat, Miguel
  • Martín-López, Sonia
  • González-Herráez, Miguel
  • Fernández-Ruiz, María R.
In symmetric dual-comb spectroscopy, two optical frequency combs with slightly different repetition rates are transmitted through a sample under test. Traditionally, this configuration has been regarded as suitable for measuring only the magnitude of the spectral response of the sample, with the phase information typically sacrificed in favor of a more robust setup against instabilities in the measurement paths, as compared to an asymmetric configuration. In this work, we formulate and demonstrate an algorithm capable of extracting the spectral phase information of a sample from the analysis of high-order Nyquist zones in a symmetric dual-comb spectroscopy configuration. The phase reconstruction strategy is generalized for both standard and quasi-integer ratio (QIR) dual-comb schemes. The capability of recovering both the magnitude and phase spectral profiles by using the generalized phase-reconstruction algorithm in a symmetric configuration is validated by means of two samples, a lossy fiber-based ring resonator and a traceable hydrogen cyanide (HCN) gas cell., The work of María R. Fernández-Ruiz was supported by MCIN/AEI/ 10.13039/501100011033 and European Union “NextGenerationEU”/PRTR under Grant RYC2021-032167-I. The work of Miguel Soriano-Amat was supported by MICIU/AEI/10.13039/501100011033 and FSE+ under Grant JDC2023-051111-I. This work was supported in part by the Spanish MCIN/AEI/10.13039/501100011033 and the European Union NextGenerationEU/PRTR Program under GrantPSI PLEC2021-007875 and Grant CPP2021-008869, in part by Spanish MCIN/AEI/10.13039/501100011033, in part by FEDER Una manera de hacer Europa under Grant PRECISION PID2021-128000OB-C21 and Grant MOTION PID2022-140963OA-I00, in part by the European Innovation Council under Grant SAFE 101098992, Grant SUBMERSE 101095055, and Grant ECSTATIC 101189595, and in part by MCIN/AEI/10.13039/501100011033 under Grant SEASNAKE+ PCI2023- 145978-2 of CETPartnership 2022 joint call., Peer reviewed
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Self-referenced carrier frequency offset interferogram correction for distributed sensing using dual-comb systems

  • Romero Barrueco, Alonso|||0009-0004-1197-9653
  • Escobar Vera, Camilo|||0000-0001-7193-9590
  • Quevedo Galán, Clara|||0000-0001-5501-4117
  • Rosado Pérez, Alejandro|||0000-0002-9276-7051
  • Mateu Comas, Julia|||0009-0000-5483-325X
  • Martín López, Sonia
  • González Herráez, Miguel
  • Esquivias Moscardo, Ignacio|||0000-0001-7298-8271
  • Fernández Ruiz, María del Rosario|||0000-0003-3561-2405
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Vessel detection and localization using distributed acoustic sensing in submarine optical fiber cables

  • Rámirez Torres, Erick Eduardo|||0000-0002-9482-2819
  • Macías Guarasa, Javier|||0000-0002-3303-3963
  • Pizarro Pérez, Daniel|||0000-0003-0622-4884
  • Tejedor Noguerales, Javier
  • Palazuelos Cagigas, Sira Elena|||0000-0002-2311-441X
  • Vidal Moreno, Pedro Jose|||0000-0003-1123-7073
  • Martín López, Sonia|||0000-0001-5203-6206
  • González Herráez, Miguel|||0000-0003-2555-2971
  • Vanthillo, Roel
Submarine cables play a critical role in global internet connectivity, energy transmission, and communication but remain vulnerable to accidental damage and sabotage. Recent incidents in the Baltic Sea highlighted the need for enhanced monitoring to protect this vital infrastructure. Traditional vessel detection methods, such as synthetic aperture radar, video surveillance, and multispectral satellite imagery, face limitations in real-time processing, adverse weather conditions, and coverage range. This article explores distributed acoustic sensing (DAS) as an alternative by repurposing submarine telecommunication cables as large-scale acoustic sensor arrays. DAS offers continuous real-time monitoring, operates independently of cooperative systems, such as the automatic identification system, being largely unaffected by lighting or weather conditions. However, existing research on DAS for vessel tracking is limited in scale and lacks validation under real-world conditions. To address these gaps, a general and systematic methodology is presented for vessel detection and distance estimation using DAS. Advanced machine learning models are applied to improve detection and localization accuracy in dynamic maritime environments. The approach is evaluated on a real pre-existing 28 km submarine fiber-optic cable deployed in the North Sea over a continuous ten-day period, covering diverse ship and operational conditions, representing one of the largest scale DAS-based vessel monitoring studies to date, and for which we release the full evaluation dataset. Results demonstrate DAS as a practical tool for maritime surveillance, with an overall F1-score of over 90% in vessel detection at the selected 1000-m operating threshold, and a mean absolute error of 141 m for vessel distance estimation, toward bridging the gap between experimental research and real-world deployment., Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Phase-sensitive symmetric dual-comb spectroscopy

  • Mateu Comas, Julia
  • Romero Barrueco, Alonso Víctor
  • Soriano Amat, Miguel|||0000-0002-4819-3898
  • Martín López, Sonia|||0000-0001-5203-6206
  • González Herráez, Miguel|||0000-0003-2555-2971
  • Fernández Ruiz, María Del Rosario|||0000-0003-3561-2405
In symmetric dual-comb spectroscopy, two optical frequency combs with slightly different repetition rates are transmitted through a sample under test. Traditionally, this configuration has been regarded as suitable for measuring only the magnitude of the spectral response of the sample, with the phase information typically sacrificed in favor of a more robust setup against instabilities in the measurement paths, as compared to an asymmetric configuration. In this work, we formulate and demonstrate an algorithm capable of extracting the spectral phase information of a sample from the analysis of high-order Nyquist zones in a symmetric dual-comb spectroscopy configuration. The phase reconstruction strategy is generalized for both standard and quasi-integer ratio (QIR) dual-comb schemes. The capability of recovering both the magnitude and phase spectral profiles by using the generalized phase-reconstruction algorithm in a symmetric configuration is validated by means of two samples, a lossy fiber-based ring resonator and a traceable hydrogen cyanide (HCN) gas cell., Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, European Commission