RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Magnetic and electric antennas calibration for partial discharge charge estimation in gas-insulated substations

  • Mier, Christian
  • Castro, Luis
  • Vaessen, Peter
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
[EN] There are no accepted procedures that quantify the apparent charge of partial discharge (PD) in gas-insulated substations (GIS). This paper proposes a calibration method for PD charge estimation using unconventional electromagnetic sensors: a magnetic loop antenna (inductive coupler) and an electric antenna (capacitive coupler.) The calibration procedure is intended for the voltage double integral method, which is reviewed for magnetic antennas and extended for electric antennas. By injecting low-frequency sinusoidal signals, the cali-bration constants are determined for two different test setups: the first one being a testbench where the char-acteristic impedance is matched and the second one a full-scale 420 kV GIS. The calibration method is validated in three ways: with a calibrated pulse in the testbench, a calibrated pulse in a full-scale GIS, and PD defects in the full-scale GIS. The calibration procedure revealed a frequency limit range dependent on the GIS length and the sensor's signal-to-noise ratio. The three validation methods showed low charge estimation errors for the mag-netic and electric antennas, demonstrating that the PD calibration method applies to any electric/magnetic detector with a low-frequency derivative response. This research paves the way for better GIS insulation monitoring and PD sensor harmonization.(c) 2017 Elsevier Inc. All rights reserved., This project 19ENG02 FutureEnergy has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme. Funder ID: 10.13039/100014132.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Validation of a Qualification Procedure Applied to the Verification of Partial Discharge Analysers Used for HVDC or HVAC Networks

  • Vera, Carlos
  • Garnacho, Fernando
  • Klüss, Joni
  • Mier, Christian
  • Álvarez, Fernando
  • Lahti, Kari
  • Khamlichi, Abderrahim
  • Elg, Alf-Peter
  • Arcones, Eduardo
  • Camuñas, Álvaro
  • Pakonen, Perti
  • Ortego, Javier
  • Vidal, José Ramón
  • Haider, Miran
  • Rovira, Jorge
  • Simón, Pascual
  • Squicciarini, Antonio
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
[EN] The insulation condition of HVDC grids consisting of cable systems, GIS, and converters should be monitored by partial discharge (PD) analysers using artificial intelligence (AI) tools for efficient insulation diagnosis. Although there are many experiences of PD monitoring solutions developed for the supervision of the insulation condition of HVAC grids using PD analysers, there are no standardised requirements for their qualification available yet. The international technical specification TS IEC 62478 provides general rules for PD measurements using electromagnetic methods but does not define performance requirements for qualification tests. HVDC and HVAC PD analysers must be tested by unambiguous test procedures. This paper compiles experiences of using PD analysers with HFCT sensors in HVAC grids (cable systems, GIS, and AIS) to define a qualification procedure for HVAC systems. This procedure is applicable to HVDC grids (cable systems, GIS, AIS, and converters) because the particularities related to the insulation behaviour under HVDC voltage are also considered. Representative PD sources are discussed in HVAC and HVDC positive and negative polarity. The PD pulse trend of representative insulation defects in HVDC cable systems is quite different from that of HVAC grids. Special attention should be paid to the acquisition of PD signals in HVDC grids since few pulses appear in solid insulations, mainly during voltage changes (polarity reversals or surges), but rarely in continuous operation with constant direct voltage. A synthetic PD simulator has been developed to reproduce trains of PD pulses or noise signals, similar to those that can appear in the power network. A set of three functionality tests has been developed for qualification of the diagnostic capabilities of PD analysers working up to 30 MHz addressed to HVDC or HVAC grids: (1) PD recognition test, (2) PD clustering test, and (3) PD location test. This qualification procedure has been validated by means of a round-robin test performed by five research institutes (RISE, FFII, TUDelft, TAU, and UPM) using commercial and in-development AI PD recognition and clustering tools to demonstrate its robustness and applicability. Applying this qualification procedure, two PD methods for electrical detection and prevention of insulation defects have been approved, one for HVAC and the other for HVDC grids., This project 19ENG02 FutureEnergy has received funding from the EMPIR programme co-financed by the Participating States and from the European Union s Horizon 2020 research and innovation programme.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Metrological Qualification of PD Analysers for Insulation Diagnosis of HVDC and HVAC Grids

  • Garnacho, Fernando
  • Álvarez, Fernando
  • Elg, Alf-Peter
  • Mier, Christian
  • Lahti, Kari
  • Khamlichi, Abderrahim
  • Arcones, Eduardo
  • Klüss, Joni
  • Pakonen, Pertti
  • Vidal, José Ramón
  • Camuñas, Álvaro
  • Rovira, Jorge
  • Vera, Carlos
  • Haider, Miran
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
[EN] On-site partial discharge (PD) measurements have turned out to be a very efficient technique for determining the insulation condition in high-voltage electrical grids (AIS, cable systems, GIS, HVDC converters, etc.); however, there is not any standardised procedure for determining the performances of PD measuring systems. In on-line and on-site PD measurements, high-frequency current transformers (HFCTs) are commonly used as sensors as they allow for monitoring over long distances in high-voltage installations. To ensure the required performances, a metrological qualification of the PD analysers by applying an evaluation procedure is necessary. A novel evaluation procedure was established to specify the quantities to be measured (electrical charge and PD repetition rate) and to describe the evaluation tests considering the measured influence parameters: noise, charge amplitude, pulse width and time interval between consecutive pulses. This procedure was applied to different types of PD analysers used for off-line measurements, sporadic on-line measurements and continuous PD monitoring. The procedure was validated in a round-robin test involving two metrological institutes (RISE from Sweden and FFII from Spain) and three universities (TUDelft from the Netherlands, TAU from Finland and UPM from Spain). With this round-robin test, the effectiveness of the proposed qualification procedure for discriminating between efficient and inappropriate PD analysers was demonstrated. Furthermore, it was shown that the PD charge quantity can be properly determined for on-line measurements and continuous monitoring by integrating the pulse signals acquired with HFCT sensors. In this case, these sensors must have a flat frequency spectrum in the range between several tens of kHz and at least two tens of MHz, where the frequency pulse content is more significant. The proposed qualification procedure can be useful for improving the future versions of the technical specification TS IEC 62478 and the standard IEC 60270., The research presented in this paper has received funding from the project 19ENG02 FutureEnergy of the EMPIR programme, co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A directional coupler for partial discharge measurements in gas-insulated substations

  • Mier, Christian
  • Vaessen, Peter
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
[EN] This paper introduces a directional coupler for partial discharge (PD) measurements in gas-insulated substations (GIS). The sensor comprises a combination of magnetic and electric couplers, effectively segregating forward and backward pulses to enhance PD charge estimation and defect location. The sensor's design was supported with finite element method simulations and measurements conducted in a transverse electromagnetic test bench. Comparative analyses were performed against independent magnetic and electric couplers. The charge estimation and the directional coupler's directivity were evaluated in both the test bench and a full-scale GIS with different PD defects. Initially, the combined magnetic and the electric couplers exhibited undesired interactions, prompting corrective measures. Subsequent adjustments included changes to the electric coupler material and modifications to the magnetic coupler construction. The resulting high-voltage directional coupler performed better than the separated couplers in a GIS with discontinuities. This partial discharge sensor emerges as a candidate for future SF6-free alternative GIS., This project 19ENG02 FutureEnergy has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme. Funder ID: 10.13039/100014132.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Magnetic and electric antennas synergy for partial discharge measurements in gas-insulated substations: Power flow and reflection suppression

  • Mier, Christian
  • Vaessen, Peter
  • Lathouwers, André
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
[EN] One of the main difficulties in measuring partial discharges (PD) in gas-insulated substations (GIS) is the overlapping of pulses at the sensor's location, which distorts the pulse resolution and the charge estimation. This research presents a new method called "synergy," which identifies and suppresses reflections using magnetic and electric antennas in the very-high frequency range. By scaling the antennas' outputs and adding them, it is possible to segregate forward and backward pulses. Additionally, by multiplying the electric and magnetic signals, the power flow of the pulses is obtained, which identifies the propagation direction and the location of discontinuities in the transmission path. The synergy method is evaluated in three scenarios: a fully matched test bench using a calibrated pulse, a full-scale GIS using a calibrated pulse, and a full-scale GIS using a PD defect. The results showed that the pulse reflections can be eliminated from the incident pulse, improving the charge calculation when the pulses overlap. The output of this research represents an improvement for PD monitoring in GIS, exhibiting a tool for better defect localization, pulse wave shape construction, charge estimation, and possible interference rejection., This project 19ENG02 FutureEnergy has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme. Funder ID: 10.13039/100014132.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Partial discharge and interference discrimination in gas-insulated systems using electric and magnetic sensors

  • Mier, Christian
  • Luo, Tianming
  • Vaessen, Peter
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
[EN] The correct identification of partial discharges (PDs) is instrumental for the maintenance plan in gas-insulated systems (GIS). However, onsite PD measurements are difficult, especially in HVDC systems, where partial discharges can be confused with interference. This paper proposes a method to discern PDs from interferences based on the GIS characteristic impedance. The characteristic impedance is measured using very-high frequency electric and magnetic sensors, and it is calculated using four approaches based on the PD charge magnitude, peak value, peak-to-peak value, and frequency spectrum. The method is first tested with a PD calibrator in a matched and open-circuited GIS testbench. Then, the identification of PDs and interference is tested in a full-scale GIS, where the measurements are subjected to pulse overlapping and noise. Five types of interferences and PDs are injected into the GIS in two positions and measured in multiple mounting holes. The results show that all four approaches can precisely calculate the characteristic impedance in a matched testbench. In the full-scale GIS, these approaches show more deviation, with the peak approach being the most accurate. A practical application of the method is demonstrated using a calibrator in the full-scale GIS. The proposed method contributes to a more reliable PD monitoring system for HVDC/AC GIS and allows better maintenance planning, reducing unnecessary costs, notably for offshore substations., This project 19ENG02 FutureEnergy has received funding from the EMPIR programme co-financed by the Participating States and from the European Unions Horizon 2020 research and innovation programme. Funder ID: 10.13039/100014132.
Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

Procedures to qualify PD measuring instruments to use in the insulation condition of cable systems

  • Garnacho Vecino, Fernando|||0000-0002-7752-8810
  • Khamlichi, Abderrahim
  • Ramírez Linares, Ángel
  • Rovira, Jorge
  • Álvarez Gómez, Fernando|||0000-0002-1944-9823
  • Arcones del Álamo, Eduardo|||0000-0002-5205-7792
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Scale Modular Test Platform for the Characterization of PD Measuring Systems Using HFCT Sensors

  • Arcones del Álamo, Eduardo|||0000-0002-5205-7792
  • Álvarez Gómez, Fernando|||0000-0002-1944-9823
  • Khamlichi El Khamlichi, Abderrahim|||0000-0001-7738-3706
  • Garnacho Vecino, Fernando|||0000-0002-7752-8810
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Methods for Partial Discharge Calibration in Gas-Insulated Substations for HVDC Power Grids and Charge Evaluation Uncertainty

  • Mier Escurra, Christian|||0000-0002-2752-1987
  • Khamlichi El Khamlichi, Abderrahim|||0000-0001-7738-3706
  • Dalstein, Matthieu|||0000-0001-9103-7957
  • Vidal, José Ramón
  • Garnacho Vecino, Fernando|||0000-0002-7752-8810
  • Rodrigo Mor, Armando|||0000-0002-5719-8201
  • Vu-Cong, Thanh