Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

DAU Arxiu Digital de la Universitat Ramon Llull
Publication Artículo científico (JournalArticle)

Intraamniotic sealing of fetoscopic membrane defects in ex vivo and in vivo sheep models using an integrated semirigid bioadhesive patch

  • Micheletti, Talita
  • Eixarch, Elisenda
  • Febas, Germán
  • Berdun, Sergio
  • Parra, Johanna
  • Hernansanz, Albert
  • Borrós, Salvador
  • Gratacos, Eduard
BACKGROUND Preterm prelabor rupture of membranes is the most frequent complication of fetoscopic surgery. Strategies to seal the membrane defect created by fetoscopy have been attempted with little success. We previously developed an integrated semirigid bioadhesive patch composed of silicone and hydroxypropyl methylcellulose that achieved ex vivo sealing of membrane defects. OBJECTIVE To evaluate the feasibility of the insertion of our integrated semirigid bioadhesive patches using a fetoscopic technique and to test the adhesion in ex vivo human membranes and in an in vivo ovine model. STUDY DESIGN An experimental study involving 2 experiments: (1) ex vivo—human fetal membranes were mounted in a custom-designed model with saline solution simulating intraamniotic pressure. The insertion of 2 different bioadhesive patches made of silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose was performed through a 12-Fr cannula mimicking fetoscopic surgery technique. The experiment was repeated 10 times with membranes from different donors. Measures included insertion time, successful insertion, and adhesion at 5 minutes; (2) in vivo—16 patches of silicone-hydroxypropyl methylcellulose were inserted by fetoscopy in the amniotic cavity of pregnant sheep (4 bioadhesives per animal, in 4 ewes). Measures included successful insertion, adhesion at 5 minutes, and adhesion at the end of surgery. RESULTS In the ex vivo insertion study, there was no difference in the insertion time between silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose patches (P=.49). Insertion was successful in all cases, but complete adhesion at 5 minutes was superior for silicone-hydroxypropyl methylcellulose (P=.02). In the in vivo study, insertion of silicone-hydroxypropyl methylcellulose by fetoscopy was feasible and successful in all cases, and no complications were reported. Adhesion persisted at 5 minutes and at the end of the surgery in 68.8% and 56.3% of the patches, respectively. CONCLUSION We describe the feasibility of deploying through a fetoscopic trocar a semirigid silicone-hydroxypropyl methylcellulose patch that seals fetal membranes after an invasive fetal procedure. The results warrant further research for improving long-term adhesion and developing a clinically applicable system., info:eu-repo/semantics/publishedVersion
DAU Arxiu Digital de la Universitat Ramon Llull
Publication Artículo científico (JournalArticle)

Ex-vivo mechanical sealing properties and toxicity of a bioadhesive patch as sealing system for fetal membrane iatrogenic defects

  • Borrós, Salvador
  • Febas, Germán
  • Micheletti, Talita
  • Eixarch, Elisenda
  • Berdun, Sergio
  • Mazza, Edoardo
  • Gratacos, Eduard
Preterm prelabor rupture of membranes (PPROM) is the most frequent complication of fetal surgery. Strategies to seal the membrane defect created by fetoscopy aiming to reduce the occurrence of PPROM have been attempted with little success. The objective of this study was to evaluate the ex-vivo mechanical sealing properties and toxicity of four different bioadhesives integrated in semi-rigid patches for fetal membranes. We performed and ex-vivo study using term human fetal membranes to compare the four integrated patches composed of silicone or silicone-polyurethane combined with dopaminated-hyaluronic acid or hydroxypropyl methylcellulose (HPMC). For mechanical sealing properties, membranes were mounted in a multiaxial inflation device with saline, perforated and sealed with the 4 combinations. We measured bursting pressure and maximum pressure free of leakage (n = 8). For toxicity, an organ culture of membranes sealed with the patches was used to measure pyknotic index (PI) and lactate dehydrogenase (LDH) concentration (n = 5). All bioadhesives achieved appropriate bursting pressures, but only HPMC forms achieved high maximum pressures free of leakage. Concerning toxicity, bioadhesives showed low PI and LDH levels, suggesting no cell toxicity. We conclude that a semi-rigid patch coated with HPMC achieved ex-vivo sealing of iatrogenic defects in fetal membranes with no signs of cell toxicity. These results warrant further research addressing long-term adhesiveness and feasibility as a sealing system for fetoscopy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Heart morphology differences induced by intrauterine growth restriction and preterm birth measured on the ECG at preadolescent age

  • Ortigosa, Nuria
  • Rodriguez-Lopez, Mérida
  • Bailón, Raquel
  • Sarvari, Sebastian Imre
  • Sitges, Marta
  • Gratacos, Eduard
  • Bijnens, Bart
  • Crispi, Fatima
  • Laguna, Pablo
Intrauterine Growth Restriction (IUGR) and premature birth are associated with higher risk of cardiovascular diseases throughout adulthood. The aim of this study was to evaluate the influence of these factors in ventricular electrical remodeling in preadolescents. Electrocardiography was performed in a cohort of 33-IUGR, 32-preterm with appropriate weight and 60 controls. Depolarization and repolarization processes were studied by means of the surface ECG, including loops and angles corresponding to QRS and T-waves. The angles between the dominant vector of QRS and the frontal plane XY were different among the study groups: controls [20.03°(10.11°-28.64°)], preterm [25.48°(19.79°-33.56°)], and IUGR [27.77°(16.59°-33.23°)]. When compared to controls, IUGR subjects also presented wider angles between the difference of QRS and T-wave dominant vectors and the XY-plane [5.28° ± 12.15° vs 0.49° ± 14.15°, p b 0.05] while preterm ones showed smaller frontal QRS-T angle [4.68°(2.20°-12.89°) vs 6.57°(2.72°-11.31°), p b 0.05]. Thus, electrical remodeling is present in IUGR and preterm preadolescents, and might predispose them to cardiovascular diseases in adulthood. Follow-up studies are warranted.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Heart morphology differences induced by intrauterine growth restriction and premature birth measured on the ECG in pre-adolescents

  • Ortigosa, Nuria
  • Crispi, Fátima
  • Bailón, Raquel
  • Rodriguez-Lopez. Merida
  • Gratacós, Eduard
  • Savari, Sebastián
  • Sitges, Marta
  • Bijnens, Bart
  • Laguna, Pablo
Pre-adolescents who had suffered from intrauterine growth restriction (IUGR) during their mothers'' pregnancy usually present more spherical hearts (smaller relation between base to apex measure and basal diameter), measured using echocardiograms, which has been associated with long-term cardiac disfunction. The present work aims to analyse these heart morphology changes by means of the surface ECG so as to have an early diagnostic tool of this pathology. The dataset is conformed by 148 pre-adolescents with either preterm or term births, and with or without IUGR. Once QRS and T-wave loops were obtained from the vectorcardiogram, the angles between the dominant vector of the QRS loop and -XY or -YZ planes(FR-XY, FR-YZ) and the difference between FR-XY and the angle between the dominant vector of T-wave loop (FT-XY) and the XY-plane showed different values for pre-adolescents who suffered from premature birth and IUGR than for control subjects (p < 0.05). These characteristics can open the door for a much easier diagnosis and follow-up of candidates for these disfunctions.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Ex-vivo mechanical sealing properties and toxicity of a bioadhesive patch as sealing system for fetal membrane iatrogenic defects

  • Borrós, Salvador
  • Febas, Germán
  • Micheletti, Talita
  • Eixarch, Elisenda
  • Berdun, Sergio
  • Mazza, Edoardo
  • Gratacos, Eduard
Preterm prelabor rupture of membranes (PPROM) is the most frequent complication of fetal surgery. Strategies to seal the membrane defect created by fetoscopy aiming to reduce the occurrence of PPROM have been attempted with little success. The objective of this study was to evaluate the ex-vivo mechanical sealing properties and toxicity of four different bioadhesives integrated in semi-rigid patches for fetal membranes. We performed and ex-vivo study using term human fetal membranes to compare the four integrated patches composed of silicone or silicone-polyurethane combined with dopaminated-hyaluronic acid or hydroxypropyl methylcellulose (HPMC). For mechanical sealing properties, membranes were mounted in a multiaxial inflation device with saline, perforated and sealed with the 4 combinations. We measured bursting pressure and maximum pressure free of leakage (n = 8). For toxicity, an organ culture of membranes sealed with the patches was used to measure pyknotic index (PI) and lactate dehydrogenase (LDH) concentration (n = 5). All bioadhesives achieved appropriate bursting pressures, but only HPMC forms achieved high maximum pressures free of leakage. Concerning toxicity, bioadhesives showed low PI and LDH levels, suggesting no cell toxicity. We conclude that a semi-rigid patch coated with HPMC achieved ex-vivo sealing of iatrogenic defects in fetal membranes with no signs of cell toxicity. These results warrant further research addressing long-term adhesiveness and feasibility as a sealing system for fetoscopy.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Intraamniotic sealing of fetoscopic membrane defects in ex vivo and in vivo sheep models using an integrated semirigid bioadhesive patch

  • Micheletti, Talita
  • Eixarch, Elisenda
  • Febas, Germán
  • Berdun, Sergio
  • Parra, Johanna
  • Hernansanz, Albert
  • Borrós, Salvador
  • Gratacos, Eduard
BACKGROUND Preterm prelabor rupture of membranes is the most frequent complication of fetoscopic surgery. Strategies to seal the membrane defect created by fetoscopy have been attempted with little success. We previously developed an integrated semirigid bioadhesive patch composed of silicone and hydroxypropyl methylcellulose that achieved ex vivo sealing of membrane defects. OBJECTIVE To evaluate the feasibility of the insertion of our integrated semirigid bioadhesive patches using a fetoscopic technique and to test the adhesion in ex vivo human membranes and in an in vivo ovine model. STUDY DESIGN An experimental study involving 2 experiments: (1) ex vivo—human fetal membranes were mounted in a custom-designed model with saline solution simulating intraamniotic pressure. The insertion of 2 different bioadhesive patches made of silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose was performed through a 12-Fr cannula mimicking fetoscopic surgery technique. The experiment was repeated 10 times with membranes from different donors. Measures included insertion time, successful insertion, and adhesion at 5 minutes; (2) in vivo—16 patches of silicone-hydroxypropyl methylcellulose were inserted by fetoscopy in the amniotic cavity of pregnant sheep (4 bioadhesives per animal, in 4 ewes). Measures included successful insertion, adhesion at 5 minutes, and adhesion at the end of surgery. RESULTS In the ex vivo insertion study, there was no difference in the insertion time between silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose patches (P=.49). Insertion was successful in all cases, but complete adhesion at 5 minutes was superior for silicone-hydroxypropyl methylcellulose (P=.02). In the in vivo study, insertion of silicone-hydroxypropyl methylcellulose by fetoscopy was feasible and successful in all cases, and no complications were reported. Adhesion persisted at 5 minutes and at the end of the surgery in 68.8% and 56.3% of the patches, respectively. CONCLUSION We describe the feasibility of deploying through a fetoscopic trocar a semirigid silicone-hydroxypropyl methylcellulose patch that seals fetal membranes after an invasive fetal procedure. The results warrant further research for improving long-term adhesion and developing a clinically applicable system., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Intraamniotic sealing of fetoscopic membrane defects in ex vivo and in vivo sheep models using an integrated semirigid bioadhesive patch

  • Micheletti, Talita
  • Eixarch Roca, Elisenda
  • Febas Bosomba, Germán
  • Berdún Martín, Sergio
  • Parra Hernández, Johanna
  • Hernansanz Prats, Alberto
  • Borrós Gómez, Salvador
  • Gratacós Solsona, Eduard
BACKGROUND: Preterm prelabor rupture of membranes is the most frequent complication of fetoscopic surgery. Strategies to seal the membrane defect created by fetoscopy have been attempted with little success. We previously developed an integrated semirigid bioadhesive patch composed of silicone and hydroxypropyl methylcellulose that achieved ex vivo sealing of membrane defects. OBJECTIVE: To evaluate the feasibility of the insertion of our integrated semirigid bioadhesive patches using a fetoscopic technique and to test the adhesion in ex vivo human membranes and in an in vivo ovine model. STUDY DESIGN: An experimental study involving 2 experiments: (1) ex vivo—human fetal membranes were mounted in a custom-designed model with saline solution simulating intraamniotic pressure. The insertion of 2 different bioadhesive patches made of silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose was performed through a 12-Fr cannula mimicking fetoscopic surgery technique. The experiment was repeated 10 times with membranes from different donors. Measures included insertion time, successful insertion, and adhesion at 5 minutes; (2) in vivo—16 patches of silicone-hydroxypropyl methylcellulose were inserted by fetoscopy in the amniotic cavity of pregnant sheep (4 bioadhesives per animal, in 4 ewes). Measures included successful insertion, adhesion at 5 minutes, and adhesion at the end of surgery. RESULTS: In the ex vivo insertion study, there was no difference in the insertion time between silicone-hydroxypropyl methylcellulose and silicone-polyurethane-hydroxypropyl methylcellulose patches (P=.49). Insertion was successful in all cases, but complete adhesion at 5 minutes was superior for silicone-hydroxypropyl methylcellulose (P=.02). In the in vivo study, insertion of silicone-hydroxypropyl methylcellulose by fetoscopy was feasible and successful in all cases, and no complications were reported. Adhesion persisted at 5 minutes and at the end of the surgery in 68.8% and 56.3% of the patches, respectively. CONCLUSION: We describe the feasibility of deploying through a fetoscopic trocar a semirigid silicone-hydroxypropyl methylcellulose patch that seals fetal membranes after an invasive fetal procedure. The results warrant further research for improving long-term adhesion and developing a clinically applicable system., This project has been funded by the Cellex Foundation and the Erasmus+ Programme of the European Union (Framework Agreement number: 2013-0040). This publication reflects only the authors’ views, and the Commission cannot be held responsible for any use that may be made of the information contained therein. T.M. was supported by a predoctoral grant from Erasmus Mundus FetalMed-PhD. E.E. has received funding from the Departament de Salut under grant number SLT008/18/00156., Peer Reviewed, Postprint (published version)