Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Validity and sensitivity of instrumented postural and gait assessment using low-cost devices in Parkinson&apos, s disease

  • Álvarez, Ignacio
  • Latorre, Jorge
  • Aguilar, Miquel
  • Pastor, Pau
  • Llorens Rodríguez, Roberto|||0000-0002-8677-8707
[EN] Background Accurate assessment of balance and gait is necessary to monitor the clinical progress of Parkinson's disease (PD). Conventional clinical scales can be biased and have limited accuracy. Novel interactive devices are potentially useful to detect subtle posture or gait-related impairments. Methods Posturographic and single and dual-task gait assessments were performed to 54 individuals with PD and 43 healthy controls with the Wii Balance Board and the Kinect v2 and the, respectively. Individuals with PD were also assessed with the Tinetti Performance Oriented Mobility Assessment, the Functional Gait Assessment and the 10-m Walking Test. The influence of demographic and clinical variables on the performance in the instrumented posturographic and gait tests, the sensitivity of these tests to the clinical condition and phenotypes, and their convergent validity with clinical scales were investigated. Results Individuals with PD in H&Y I and I.5 stages showed similar performance to controls. The greatest differences in posture and gait were found between subjects in H&Y II.5 and H&Y I-I.5 stage, as well as controls. Dual-tasking enhanced the differences among all groups in gait parameters. Akinetic/rigid phenotype showed worse postural control and gait than other phenotypes. High significant correlations were found between the limits of stability and most of gait parameters with the clinical scales. Conclusions Low-cost devices showed potential to objectively quantify posture and gait in established PD (H&Y >= II). Dual-tasking gait evaluation was more sensitive to detect differences among PD stages and compared to controls than free gait. Gait and posture were more impaired in akinetic/rigid PD., This study has been funded by project VALORA, Grant 201701-10 of the Fundacio la Marato de la TV3 (Barcelona, Spain) and the European Union through the Operational Program of the European Regional Development Fund (ERDF) of the Valencian Community 2014-2020 (IDIFEDER/2018/029) to RL, and Alter Laboratories SA to PP.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Embodiment and Presence in Virtual Reality After Stroke. A Comparative Study With Healthy Subjects

  • Borrego, Adrián|||0000-0001-5134-7811
  • Alcañiz Raya, Mariano Luis|||0000-0001-9207-0636
  • Llorens Rodríguez, Roberto|||0000-0002-8677-8707
  • Latorre, Jorge
[EN] The ability of virtual reality (VR) to recreate controlled, immersive, and interactive environments that provide intensive and customized exercises has motivated its therapeutic use after stroke. Interaction and bodily presence in VR-based interventions is usually mediated through virtual selves, which synchronously represent body movements or responses to events on external input devices. Embodied self-representations in the virtual world not only provide an anchor for visuomotor tasks, but their morphologies can have behavioral implications. While research has focused on the underlying subjective mechanisms of exposure to VR on healthy individuals, the transference of these findings to individuals with stroke is not evident and remains unexplored, which could affect the experience and, ultimately, the clinical effectiveness of neurorehabilitation interventions. This study determined and compared the sense of embodiment and presence elicited by a virtual environment under different perspectives and levels of immersion in healthy subjects and individuals with stroke. Forty-six healthy subjects and 32 individuals with stroke embodied a gender-matched neutral avatar in a virtual environment that was displayed in a first-person perspective with a head-mounted display and in a third-person perspective with a screen, and the participants were asked to interact in a virtual task for 10 min under each condition in counterbalanced order, and to complete two questionnaires about the sense of embodiment and presence experienced during the interaction. The sense of body-ownership, self-location, and presence were more vividly experienced in a first-person than in a third-person perspective by both healthy subjects (p < 0.001, eta(2)(p) = 0.212; p = 0.005, eta(2)(p) = 0.101; p = 0.001, eta(2)(p) = 0.401, respectively) and individuals with stroke (p = 0.019, eta(2)(p) = 0.070; p = 0.001, eta(2)(p) = 0.135; p = 0.014, eta(2)(p) = 0.077, respectively). In contrast, no agency perspective-related differences were found in any group. All measures were consistently higher for healthy controls than for individuals with stroke, but differences between groups only reached statistical significance in presence under the first-person condition (p < 0.010, eta(2)(p) = 0.084). In spite of these differences, the participants experienced a vivid sense of embodiment and presence in almost all conditions. These results provide first evidence that, although less intensively, embodiment and presence are similarly experienced by individuals who have suffered a stroke and by healthy individuals, which could support the vividness of their experience and, consequently, the effectiveness of VR-based interventions., This study was funded by Ministerio de Economía y Competitividad of Spain (Project RTC-2017-6051-7 and Grant BES-2014-068218), Fundació la Marató de la TV3 (Grant 201701-10), and Universitat Politècnica de València (Grant PAID-10-18). We acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A virtual reality bus ride as an ecologically valid assessment of balance: a feasibility study

  • Gonçalves, A.
  • Montoya, M. F.
  • Bermúdez i Badia, S.
  • Llorens Rodríguez, Roberto|||0000-0002-8677-8707
[EN] Balance disorders can have substantial adverse implications on the performance of daily activities and lead to an increased risk of falls, which often have severe negative consequences for older adults. Quantitative assessment through computerized force plate-based posturography enables objective assessment of postural control but could not successfully represent specific abilities required during daily activities. The use of virtual reality (VR) could improve the representative design of functional activities and increase the ecological validity of posturographic tests, which would enhance the transferability of results to the real world. In this work, we investigate the feasibility of a simulated bus ride experienced in a surround-screen VR system to assess balance with increased ecological validity. Participants were first evaluated with a posturography test and then with the VR-based bus ride test, while the reactions of their centre of pressure were registered. Lastly, participants provided self-reported measures of the elicited sense of presence during the test. A total of 16 healthy young adults completed the study. Results showed that the simulation could elicit significant medial-lateral excursions of the centre of pressure in response to variations in the optical flow. Furthermore, these responses' amplitude negatively correlated with the participants' posturography excursions when fixating a target. Although the sense of presence was moderate, likely due to the passive nature of the test, the results support the feasibility of our proposed paradigm, based in the context of a meaningful daily living activity, in assessing balance control components, This work was supported by the Fundacao para a Ciencia e Tecnologia through the AHA project (CMUPERI/HCI/0046/2013), and NOVA-LINCS (UID/CEC/04516/2019), by the INTERREG program through the MACBIOIDI project (MAC/1.1.b/098), by project VALORA, Grant 201701-10 of the Fundacio la Marato de la TV3 (Barcelona, Spain) and the European Union through the Operational Program of the European Regional Development Fund (ERDF) of the Valencian Community 2014-2020 (IDIFEDER/2018/029)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluation of a Low-Cost Virtual Reality Surround-Screen Projection System

  • Gonçalves, Afonso
  • Latorre, Jorge
  • Bermúdez, Sergi
  • Borrego, Adrián|||0000-0001-5134-7811
  • Llorens Rodríguez, Roberto|||0000-0002-8677-8707
[EN] Two of the most popular mediums for virtual reality are head-mounted displays and surround-screen projection systems, such as CAVE Automatic Virtual Environments. In recent years, HMDs suffered a significant reduction in cost and have become widespread consumer products. In contrast, CAVEs are still expensive and remain accessible to a limited number of researchers. This study aims to evaluate both objective and subjective characteristics of a CAVE-like monoscopic low-cost virtual reality surround-screen projection system compared to advanced setups and HMDs. For objective results, we measured the head position estimation accuracy and precision of a low-cost active infrared (IR) based tracking system, used in the proposed low-cost CAVE, relatively to an infrared marker-based tracking system, used in a laboratory-grade CAVE system. For subjective characteristics, we investigated the sense of presence and cybersickness elicited in users during a visual search task outside personal space, beyond arms reach, where the importance of stereo vision is diminished. Thirty participants rated their sense of presence and cybersickness after performing the VR search task with our CAVE-like system and a modern HMD. The tracking showed an accuracy error of 1.66 cm and .4 mm of precision jitter. The system was reported to elicit presence but at a lower level than the HMD, while causing significant lower cybersickness. Our results were compared to a previous study performed with a laboratory-grade CAVE and support that a VR system implemented with low-cost devices could be a viable alternative to laboratory-grade CAVEs for visual search tasks outside the users personal space., This work was supported by the Fundação para a Ciência e Tecnologia through the AHA project (CMUPERI/HCI/0046/2013), by the INTERREG program through the MACBIOIDI project (MAC/1.1.b/098), LARSyS (UIDB/50009/2020), NOVA-LINCS (UID/CEC/04516/2019), by Fundació la Marató de la TV3 (201701-10), and the European Union through the Operational Program of the European Regional Development Fund (ERDF) of the Valencian Community 2014-2020 (IDIFEDER/2018/029)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Validation of Using Smartphone Built-In Accelerometers to Estimate the Active Energy Expenditures of Full-Time Manual Wheelchair Users with Spinal Cord Injury

  • Marco-Ahulló, Adrià
  • Montesinos-Magraner, Lluïsa
  • Gonzalez, Luis-Millan
  • Segura-Navarro, Xurxo
  • García-Massó, Xavier
  • Llorens Rodríguez, Roberto|||0000-0002-8677-8707
[EN] This study aimed to investigate the validity of using built-in smartphone accelerometers to estimate the active energy expenditures of full-time manual wheelchair users with spinal cord injury (SCI). Twenty participants with complete SCI completed 10 5-min daily activities that involved the upper limbs, during which their oxygen consumption and upper limb activity were registered using a portable gas analyzer and a smartphone (placed on the non-dominant arm), respectively. Time series of 1-min averaged oxygen consumption and 55 accelerometer variables (13 variables for each of the four axes and three additional variables for the correlations between axes) were used to estimate three multiple linear models, using a 10-fold cross-validation method. The results showed that models that included either all variables and models or that only included the linear variables showed comparable performance, with a correlation of 0.72. Slightly worse general performance was demonstrated by the model that only included non-linear variables, although it proved to be more accurate at estimating the energy expenditures (EE) during specific tasks. These results suggest that smartphones could be a promising low-cost alternative to laboratory-grade accelerometers to estimate the energy expenditure of wheelchair users with spinal cord injury during daily activities., This work was supported by Fundacio la Marato de la TV3, under Projects 201720-10 and 201701-10, and European Union through the Operational Program of the European Regional Development Fund (ERDF) of the Valencian Community 2014-2020 (IDIFEDER/2018/029)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Multi-touch-based assessment of hand mobility, dexterity and function. Preliminary study of validity, reliability and sensitivity to upper limb impairment severity in individuals with stroke.

  • Latorre, Jorge
  • Mollà-Casanova, Sara
  • Salinas, Bárbara
  • Colomer, Carolina
  • Borrego, Adrián|||0000-0001-5134-7811
  • Alcañiz Raya, Mariano Luis|||0000-0001-9207-0636
  • Llorens Rodríguez, Roberto|||0000-0002-8677-8707
[EN] Impairments of the upper limb function are among the most common and disabling sequelae after stroke, and their rehabilitation poses a major challenge for current physical and occupational therapy interventions. While restoration of certain degree of proximal and global movements and function is expected, the recovery of premorbid hand mobility and dexterity is less likely to occur. Although great efforts are usually made to rehabilitate these skills, with customized particular and analytic exercises, their assessment is rarely made with the same level of specificity. In general, hand and finger mobility and functionality are indirectly assessed in the clinic with standardized clinical scales and tests that require the use of these skills to perform some tasks. Although these scales are easy to administer, they can present poor accuracy, be biased, and do not allow for isolated assessment of joints and movements. Multi-touch technology enables interaction with electronic devices, such as smartphones and tablets, with on-screen finger touches. Although there is a very limited number of studies that investigate the potential of this technology to rehabilitate hand mobility and dexterity, the use of this technology for assessment of these skills remains unexplored. This study evaluates the feasibility of a multi-touch-based assessment tool (app) of hand mobility and dexterity in a sample of post-stroke survivors. Our results provide preliminary evidence that this technology can be used to design valid and reliable instruments for assessing hand mobility and dexterity that, in addition, are sensitive to the severity of the motor impairment of the upper limb after stroke, which could complement conventional clinical assessment., This study was partially funded by project VALORA, Fundació la Marató de la TV3 (grant 201701-10), grant BES-2014-068218 of the Ministerio de Economía y Competitividad of Spain, and grant Ayuda a Primeros Proyectos de Investigación (PAID-06-18), Vicerrectorado de Investigación, Innovación y Transferencia de la Universitat Politècnica de València, València, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Gait analysis with the Kinect v2: normative study with healthy individuals and comprehensive study of its sensitivity, validity, and reliability in individuals with stroke

  • Latorre, Jorge
  • Colomer, Carolina
  • Alcañiz Raya, Mariano Luis|||0000-0001-9207-0636
  • Llorens Rodríguez, Roberto|||0000-0002-8677-8707
[EN] Background: Gait is usually assessed by clinical tests, which may have poor accuracy and be biased, or instrumented systems, which potentially solve these limitations at the cost of being time-consuming and expensive. The different versions of the Microsoft Kinect have enabled human motion tracking without using wearable sensors at a low-cost and with acceptable reliability. This study aims: First, to determine the sensitivity of an open-access Kinect v2-based gait analysis system to motor disability and aging; Second, to determine its concurrent validity with standardized clinical tests in individuals with stroke; Third, to quantify its inter and intra-rater reliability, standard error of measurement, minimal detectable change; And, finally, to investigate its ability to identify fall risk after stroke. Methods: The most widely used spatiotemporal and kinematic gait parameters of 82 individuals post-stroke and 355 healthy subjects were estimated with the Kinect v2-based system. In addition, participants with stroke were assessed with the Dynamic Gait Index, the 1-min Walking Test, and the 10-m Walking Test. Results: The system successfully characterized the performance of both groups. Significant concurrent validity with correlations of variable strength was detected between all clinical tests and gait measures. Excellent inter and intra-rater reliability was evidenced for almost all measures. Minimal detectable change was variable, with poorer results for kinematic parameters. Almost all gait parameters proved to identify fall risk. Conclusions: Results suggest that although its limited sensitivity to kinematic parameters, the Kinect v2-based gait analysis could be used as a low-cost alternative to laboratory-grade systems to complement gait assessment in clinical settings., This study was funded by project VALORA, grant 201701-10 of the Fundacio la Marato de la TV3 (Barcelona, Spain), and grant "Ayuda a Primeros Proyectos de Investigacion (PAID-06-18), Vicerrectorado de Investigacion, Innovacion y Transferencia de la Universitat Politecnica de Valencia" (Valencia, Spain).