Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Polarimetric Images of Biological Tissues Based on the Arrow Decomposition of Mueller Matrices

  • Gil Pérez, José Jorge|||0000-0003-1740-2244
  • San José, Ignacio|||0000-0002-5370-7232
  • Canabal-Carbia, Mónica|||0000-0002-3735-1176
  • Estévez, Irene|||0000-0003-3693-8335
  • González-Arnay, Emilio
  • Luque, Jordi|||0000-0003-0751-9692
  • Garnatje, Teresa|||0000-0001-6295-6217
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
Polarimetric techniques are widely used in a vast number of applications such as remote sensing, material characterization, astronomy and biological tissue inspection. In this last scenario, different polarimetric observables have proved their potential for enhancing imaging visualization. In this work we use a set of polarimetric observables derived from the arrow decomposition of the Mueller matrix for the first time: enpolarizing, retarding and depolarizing descriptors. In particular, the mean intensity coefficient and the three indices of polarimetric purity, the absolute values and Poincaré orientations of diattenuation, polarizance, entrance retardance and exit retardance vectors are considered. Results show images with enhanced visualization or even revealing invisible structures when compared to standard intensity images. In particular, thanks to these metrics, we improve the visualization of the necrotic areas of a Vitis rupestris leaf. In the case of animal samples, boundaries between different fascicles inside a tendon of an ex vivo chicken sample are revealed, as is the directionality of fiber tracts of the subcortical white matter in an ex vivo cow brain. The experimental results show the potential for biophotonics imaging and how polarimetric techniques could be useful for biomedical and botanical applications.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Connecting the microscopic depolarizing origin of samples with macroscopic measures of the Indices of Polarimetric Purity

  • Canabal-Carbia, Mónica|||0000-0002-3735-1176
  • Estévez, Irene|||0000-0003-3693-8335
  • Nabadda, Esther|||0000-0002-6739-4468
  • Garcia-Caurel, Enrique
  • Gil Pérez, José Jorge|||0000-0003-1740-2244
  • Ossikovski, Razvigor
  • Márquez Ruiz, Andrés|||0000-0003-4123-2011
  • Moreno, Ignacio|||0000-0002-1550-0601
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
In this work we show how a specific set of three depolarizing observables, the Indices of Polarimetric Purity (IPP), P1, P2 and P3, are ideal metrics to study the depolarization characteristic of media. We simulate different depolarizing scenarios, based on different depolarizing origins, and we study the corresponding IPP values. The simulations are based on the incoherent addition of multiple elemental polarizing elements, as ideal polarizers and/or retarders with different specific characteristics (orientation, retardance, transmittance, etc.). Further depolarizing scenarios are also studied by including the effect of ideal depolarizers. We show for the first time how by analyzing depolarizing systems through IPP we unravel two different depolarizing origins: isotropic and anisotropic depolarization, with meaningful physical interpretation. The former, isotropic depolarization is related to pure scattering processes, and mainly connected with P3 observable. The later, anisotropic depolarization is originated by microscopic constituent elements showing polarimetric anisotropy (dichroic and/or birefringent elements with different characteristics) and anisotropic scattering produced by these elements, and mainly described by P1 and P2 observables. Both effects can be simultaneously observed in real samples and give us information of the processes that give rise to depolarization in light-matter interactions. The simulated results are experimentally validated by analyzing the depolarizing behavior, in terms of IPP, of diverse real samples with easy physical interpretation, and direct connection with simulations. The present study could be of interest in multiple scenarios, to further understand the depolarizing response of samples, and it can be of special interest for the study of biological tissues and pathologies, as they present important depolarizing behavior.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Analysis of the Image Magnification Produced by Inline Holographic Systems Based on the Double-Sideband Filter

  • Ramirez, Claudio
  • Estévez, Irene|||0000-0003-3693-8335
  • Lizana, Angel|||0000-0002-4861-8657
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • García-Canseco, Luisa
In-line digital holography is a powerful tool widely used for microscopic object imaging. Usually, in-line and out-line configurations are used to implement holographic systems, but in-line-based set-ups are preferable as they are less sensitive to mechanical vibrations and refraction index variations. However, non-desired blurred conjugate images are superposed to the reconstructed object image by using in-line systems. One strategy to remove the conjugate image contribution is to include a double-sideband filter at the Fourier plane of the system. After using the filter, data obtained at the CCD are processed to retrieve the magnitude and phase (hologram) of the diffracted wavefront while removing the conjugated image. Afterwards, a diffraction integral equation is used to digitally propagate the hologram. Despite the above-mentioned factors, there is not a thorough analysis in the literature of magnification parameters associated with the final reconstructed image, this aspect being crucial for the experimental application of the above-stated approach. Under this scenario, a theoretical analysis of the longitudinal and transverse magnifications of the reconstructed images is provided in this work. The method is validated through the simulation and experimental results of different microscopic objects: glass microspheres, a micrometric reticle, and a resolution test chart USAF 1951. The obtained results provide that the combination of magnification relations with methods for hologram propagation and optimal focused image identification is effective for object position determination. This approach could be useful for 3D microparticle localization and monitoring with optimized magnification within real-time applications.