Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Characterisation of the Atmosphere in Very High Energy Gamma-Astronomy for Imaging Atmospheric Cherenkov Telescopes

  • Dominis Prester, D.|||0000-0002-9880-5039
  • Ebr, Jan|||0000-0001-8807-6162
  • Gaug, Markus|||0000-0001-8442-7877
  • Hahn, Alexander|||0000-0003-0827-5642
  • Babić, Ana|||0000-0002-1444-5604
  • Eliášek, Jiří|||0000-0001-5341-6008
  • Janeček, Petr|||0000-0003-3501-7163
  • Karpov, Sergey|||0000-0003-0035-651X
  • Kolarek, Marta
  • Manganaro, Marina|||0000-0003-1530-3031
  • Mirzoyan, Razmik|||0000-0003-0163-7233
Ground-based observations of Very High Energy (VHE) gamma rays from extreme astrophysical sources are significantly influenced by atmospheric conditions. This is due to the atmosphere being an integral part of the detector when utilizing Imaging Atmospheric Cherenkov Telescopes (IACTs). Clouds and dust particles diminish atmospheric transmission of Cherenkov light, thereby impacting the reconstruction of the air showers and consequently the reconstructed gamma-ray spectra. Precise measurements of atmospheric transmission above Cherenkov observatories play a pivotal role in the accuracy of the analysed data, among which the corrections of the reconstructed energies and fluxes of incoming gamma rays, and in establishing observation strategies for different types of gamma-ray emitting sources. The Major Atmospheric Gamma Imaging Cherenkov (MAGIC) telescopes and the Cherenkov Telescope Array Observatory (CTAO), both located on the Observatorio del Roque de los Muchachos (ORM), La Palma, Canary Islands, use different sets of auxiliary instruments for real-time characterisation of the atmosphere. In this paper, historical data taken by MAGIC LIDAR (LIght Detection And Ranging) and CTAO FRAM (F/Photometric Robotic Telescope) are presented. From the atmospheric aerosol transmission profiles measured by the MAGIC LIDAR and CTAO FRAM aerosol optical depth maps, we obtain the characterisation of the clouds above the ORM at La Palma needed for data correction and optimal observation scheduling.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Synchrotron-based infrared microspectroscopy unveils the biomolecular response of healthy and tumour cell lines to neon minibeam radiation therapy

  • González-Vegas, Roberto|||0009-0000-4806-3092
  • Seksek, Olivier|||0000-0002-3053-3022
  • Bertho, Annaïg|||0009-0002-4526-0861
  • Bergs, J.
  • Hirayama, R.
  • Inaniwa, Taku
  • Matsufuji, N.
  • Shimokawa, Takashi|||0000-0001-6549-9277
  • Prezado, Yolanda|||0000-0001-5957-2327
  • Yousef, Ibraheem|||0000-0001-7818-8611
  • Martínez-Rovira, Immaculada|||0000-0002-2918-489X
Radioresistant tumours remain complex to manage with current radiotherapy (RT) techniques. Heavy ion beams were proposed for their treatment given their advantageous radiobiological properties. However, previous studies with patients resulted in serious adverse effects in the surrounding healthy tissues. Heavy ion RT could therefore benefit from the tissue-sparing effects of minibeam radiation therapy (MBRT). To investigate the potential of this combination, here we assessed the biochemical response to neon MBRT (NeMBRT) through synchrotron-based Fourier transform infrared microspectroscopy (SR-FTIRM). Healthy (BJ) and tumour (B16-F10) cell lines were subjected to seamless (broad beam) neon RT (NeBB) and NeMBRT at HIMAC. SR-FTIRM measurements were conducted at the MIRAS beamline of ALBA Synchrotron. Principal component analysis (PCA) permitted to assess the biochemical effects after the irradiations and 24 hours post-irradiation for the different RT modalities and doses. For the healthy cells, NeMBRT resulted in the most dissimilar spectral signatures from non-irradiated cells early after irradiations, mainly due to protein conformational modifications. Nevertheless, most of the damage appeared to recover one day post-RT; conversely, protein- and nucleic acid-related IR bands were strongly affected by NeBB 24 hours after treatment, suggesting superior oxidative damage and nucleic acid degradation. Tumour cells appeared to be less sensitive to NeBB than to NeMBRT shortly after RT. Still, after one day, both NeBB and the high-dose NeMBRT regions yielded important spectral modifications, suggestive of cell death processes, protein oxidation or oxidative stress. Lipid-associated spectral changes, especially due to the NeBB and NeMBRT peak groups for the tumour cell line, were consistent with reactive oxygen species attacks.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Investigating the biochemical response of proton minibeam radiation therapy by means of synchrotron-based infrared microspectroscopy

  • González-Vegas, Roberto|||0009-0000-4806-3092
  • Yousef, Ibraheem|||0000-0001-7818-8611
  • Seksek, Olivier|||0000-0002-3053-3022
  • Ortiz, Ramon
  • Bertho, Annaïg|||0009-0002-4526-0861
  • Juchaux, Marjorie
  • Nauraye, Catherine
  • Marzi, Ludovic De
  • Patriarca, Annalisa
  • Prezado, Yolanda|||0000-0001-5957-2327
  • Martínez-Rovira, Immaculada|||0000-0002-2918-489X
The biology underlying proton minibeam radiation therapy (pMBRT) is not fully understood. Here we aim to elucidate the biological effects of pMBRT using Fourier Transform Infrared Microspectroscopy (FTIRM). In vitro (CTX-TNA2 astrocytes and F98 glioma rat cell lines) and in vivo (healthy and F98-bearing Fischer rats) irradiations were conducted, with conventional proton radiotherapy and pMBRT. FTIRM measurements were performed at ALBA Synchrotron, and multivariate data analysis methods were employed to assess spectral differences between irradiation configurations and doses. For astrocytes, the spectral regions related to proteins and nucleic acids were highly affected by conventional irradiations and the high-dose regions of pMBRT, suggesting important modifications on these biomolecules. For glioma, pMBRT had a great effect on the nucleic acids and carbohydrates. In animals, conventional radiotherapy had a remarkable impact on the proteins and nucleic acids of healthy rats; analysis of tumour regions in glioma-bearing rats suggested major nucleic acid modifications due to pMBRT.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A 1.8 m Class Pathfinder Raman LIDAR for the Northern Site of the Cherenkov Telescope Array Observatory-Technical Design

  • Ballester Basols, Otger|||0000-0002-7126-5300
  • Blanch Bigas, Oscar|||0000-0002-8380-1633
  • Boix, Joan
  • Calisse, Paolo G.
  • Campoy-Ordaz, Anna|||0000-0001-9352-8936
  • Colak, Sidika Merve|||0000-0001-7793-3106
  • Da Deppo, Vania|||0000-0001-6273-8738
  • Doro, Michele|||0000-0001-9104-3214
  • Font Guiteras, Lluís|||0000-0003-2109-5961
  • Font-Pladevall, Eudald
  • Garcia, Rafael
  • Gaug, Markus|||0000-0001-8442-7877
  • Grau, Roger|||0000-0002-1891-6290
  • Kolar, Darko
  • López Oramas, Alicia|||0000-0003-4603-1884
  • Maggio, Camilla
  • Martínez Rodríguez, Manel|||0000-0002-9763-9155
  • Martínez, Òscar
  • Riu-Molinero, Victor|||0009-0004-5778-9070
  • Roman, David|||0000-0002-8717-9597
  • Stanič, Samo|||0000-0003-3344-8381
  • Tartera-Barberà, Júlia
  • Ubach Ramirez, Santiago|||0000-0002-6159-5883
  • Zavrtanik, Marko|||0000-0001-5606-6912
  • Živec, Miha
This paper presents the technical design of the pathfinder Barcelona Raman LIDAR (pBRL) for the northern site of the Cherenkov Telescope Array Observatory (CTAO-N) located at the Roque de los Muchachos Observatory (ORM). The pBRL is developed for continuous atmospheric characterization, essential for correcting high-energy gamma-ray observations captured by Imaging Atmospheric Cherenkov Telescopes (IACTs). The LIDAR consists of a steerable telescope with a 1.8 m parabolic mirror and a pulsed Nd:YAG laser with frequency doubling and tripling. It emits at wavelengths of 355 nm and 532 nm to measure aerosol scattering and extinction through two elastic and Raman channels. Built upon a former Cherenkov Light Ultraviolet Experiment (CLUE) telescope, the pBRL's design includes a Newtonian mirror configuration, a coaxial laser beam, a near-range system, a liquid light guide and a custom-made polychromator. During a one-year test at the ORM, the stability of the LIDAR and semi-remote-controlled operations were tested. This pathfinder leads the way to designing a final version of a CTAO Raman LIDAR which will provide real-time atmospheric monitoring and, as such, ensure the necessary accuracy of scientific data collected by the CTAO-N telescope array.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A 1.8 m Class Pathfinder Raman LIDAR for the Northern Site of the Cherenkov Telescope Array Observatory-Performance

  • Bauzá Ruiz, Pedro José|||0000-0003-4401-8010
  • Blanch Bigas, Oscar|||0000-0002-8380-1633
  • Calisse, Paolo G.
  • Campoy-Ordaz, Anna|||0000-0001-9352-8936
  • Colak, Sidika Merve|||0000-0001-7793-3106
  • Doro, Michele|||0000-0001-9104-3214
  • Font Guiteras, Lluís|||0000-0003-2109-5961
  • Gaug, Markus|||0000-0001-8442-7877
  • Grau, Roger|||0000-0002-1891-6290
  • Kolar, Darko
  • Maggio, Camilla
  • Martínez Rodríguez, Manel|||0000-0002-9763-9155
  • Stanič, Samo|||0000-0003-3344-8381
  • Ubach Ramirez, Santiago|||0000-0002-6159-5883
  • Zavrtanik, Marko|||0000-0001-5606-6912
  • Živec, Miha
The Barcelona Raman LIDAR (BRL) will provide continuous monitoring of the aerosol extinction profile along the line of sight of the Cherenkov Telescope Array Observatory (CTAO). It will be located at its Northern site (CTAO-N) on the Observatorio del Roque de Los Muchachos. This article presents the performance of the pathfinder Barcelona Raman LIDAR (pBRL), a prototype instrument for the final BRL. Power budget simulations were carried out for the pBRL operating under various conditions, including clear nights, moon conditions, and dust intrusions. The LIDAR PreProcessing (LPP) software suite is presented, which includes several new statistical methods for background subtraction, signal gluing, ground layer and cloud detection and inversion, based on two elastic and one Raman lines. Preliminary test campaigns were conducted, first close to Barcelona and later at CTAO-N, albeit during moonlit nights only. The pBRL, under these non-optimal conditions, achieves maximum ranges up to about 35 km, range resolution of about 50 m for strongly absorbing dust layers, and 500 m for optically thin clouds with the Raman channel only, leading to similar resolutions for the LIDAR ratios and Ångström exponents. Given the reasonable agreement between the extinction coefficients obtained from the Raman and elastic lines independently, an accuracy of aerosol optical depth retrieval in the order of 0.05 can be assumed with the current setup. The results show that the pBRL can provide valuable scientific results on aerosol characteristics and structure, although not all performance requirements could be validated under the conditions found at the two test sites. Several moderate hardware improvements are planned for its final upgraded version, such as gated PMTs for the elastic channels and a reduced-power laser with a higher repetition rate, to ensure that the data acquisition system is not saturated and therefore not affected by residual ringing.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Synchrotron-based infrared microspectroscopy study on the biomolecular impact of carbon minibeam radiation therapy on a mouse osteosarcoma cell line

  • González-Vegas, Roberto|||0009-0000-4806-3092
  • Cots Costa, Martina|||0009-0005-2861-6899
  • Gilbert, Cristele
  • Bertho, Annaïg|||0009-0002-4526-0861
  • Seksek, Olivier|||0000-0002-3053-3022
  • Graeff, Christian|||0000-0002-5296-7649
  • Sokol, Olga|||0000-0003-3664-7538
  • Tinganelli, Walter|||0000-0003-0844-7272
  • Prezado, Yolanda|||0000-0001-5957-2327
  • Yousef, Ibraheem|||0000-0001-7818-8611
  • Martínez-Rovira, Immaculada|||0000-0002-2918-489X
Carbon minibeam radiation therapy (CMBRT) is a novel oncology treatment modality that combines the superior radiobiological properties of carbon ions with the remarkable tissue-sparing effects of spatial dose fractionation. Nevertheless, the differential biological mechanisms that CMBRT activates are not fully understood. To shed further light on such biomolecular processes, this study analysed the impact of CMBRT on LM8 osteosarcoma cells using synchrotron-based infrared microspectroscopy (SR-FTIRM). Samples were subjected to conventional carbon RT (CBB) and CMBRT at GSI (Germany). RT-treated cells underwent SR-FTIRM evaluations at ALBA Synchrotron (Spain) at 24 h post-RT. Principal component analysis (PCA) uncovered the main spectral differences between the treatment modalities, revealing that the IR signatures of CMBRT-treated samples were the most dissimilar from Control cells. Modifications of IR peaks attributed to α-helical and β-sheet protein sub-structures were consistent with the alterations of the Amide I spectral band due to CMBRT (assessed via curve-fitting analysis), suggesting enhanced protein oxidation. Conformational alterations in the sugar-phosphate backbone of nucleic acids might also have resulted from further oxidative damage due to CMBRT. Additionally, CMBRT led to greater alterations of methylene and methyl bands compared to CBB, which may have been caused by free radical attacks. Spectral signatures in the CMBRT valleys differed from those in the CMBRT peaks, suggesting distinct biomolecular mechanisms involved in these two dose regions. Comparison with proton and neon irradiations revealed common IR features affected by MBRT modalities.