Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Equilibrium optimiser tuned frequency-shifted internal model control proportional-derivative decoupled dual-loop design for industrial plants followed by experimental validation

  • Aryan, Pulakraj
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Raja, G. Lloyds
Integrating and unstable processes require rugged control demand by virtue of their non-self-regulation character. The occurrence of system poles located at the origin and on the right half of the complex frequency plane causes instability in an open-loop configuration. When these processes proceed with dead time, it demands more sophisticated control requirements. Therefore, binal-loop control schemes are recommended over single-loop controller schemes. For plants with prevalent unstable and integrating dynamics and dead time, a novel modified inferred internal model control-proportional derivative decoupled binal-loop control system is suggested. The inner-loop is controlled by the stabilising proportional derivative controller with Routh-Hurwitz stability constraints. The outer-loop contains an inferred internal model controller for reference-point tracking. The equilibrium optimiser is then used to minimise the integral squared error by tuning the inner and outer-loop controller settings in the confined search space. The suggested strategy delivers appreciable enhancement in the quantitative performance measures as compared to some of the contemporary control techniques. The effect of time-varying disturbance and robust stability analysis is also presented. Finally, utilising a magnetic levitation laboratory setup, the suggested method is experimentally verified using the hardware-in-loop method.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Reducing the Environmental Impact of Sewer Network Overflows Using Model Predictive Control Strategy

  • Vasiliev, Iulian|||0000-0003-2791-0824
  • Luca, Laurentiu|||0000-0002-7743-6772
  • Barbu, Marian|||0000-0001-6645-3705
  • Vilanova, Ramon|||0000-0002-8035-5199
  • Caraman, Sergiu Viorel
This paper proposes a method for reducing the environmental impact of sewer network (SN) overflows. The main objective of the paper is to minimize the wastewater quantity and the pollutant loads that overflow from the SN. The proposed algorithm to achieve this goal is Model Predictive Control using Particle Swarm Optimization as optimization method. It was tested in simulation using a simplified model of the network based on Benchmark Simulation Modelsewer as prediction model, and a forecasted influent. Three cases have been considered: (a) the fitness function is defined as the global yearly overflow volume calculated using equal weights for each tank; (b) the fitness function uses different weights for each tank depending on the medium loads and (c) integrating a penalty term related to the system state at the end of the prediction horizon in the previous fitness function. The simplified model determined a significant reduction of the integration time minimizing the optimization time.