Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Repisalud
Publication Artículo científico (JournalArticle)

A Drastic Shift in Lipid Adducts in Colon Cancer Detected by MALDI-IMS Exposes Alterations in Specific K+ Channels

  • Garate, Jone
  • Maimó-Barceló, Albert
  • Bestard-Escalas, Joan
  • Fernandez, Roberto
  • Pérez-Romero, Karim
  • Martinez Ortega, Marco Antonio
  • Payeras Capo, Maria Antonia
  • Lopez, Daniel H
  • Fernández, José Andrés
  • Barceló-Coblijn, Gwendolyn
Even though colorectal cancer (CRC) is one of the most preventable cancers, it is one of the deadliest, and recent data show that the incidence in people <50 years has unexpectedly increased. While new techniques for CRC molecular classification are emerging, no molecular feature is as yet firmly associated with prognosis. Imaging mass spectrometry (IMS) lipidomic analyses have demonstrated the specificity of the lipid fingerprint in differentiating pathological from healthy tissues. During IMS lipidomic analysis, the formation of ionic adducts is common. Of particular interest is the [Na+]/[K+] adduct ratio, which already functions as a biomarker for homeostatic alterations. Herein, we show a drastic shift of the [Na+]/[K+] adduct ratio in adenomatous colon mucosa compared to healthy mucosa, suggesting a robust increase in K+ levels. Interrogating public databases, a strong association was found between poor diagnosis and voltage-gated potassium channel subunit beta-2 (KCNAB2) overexpression. We found this overexpression in three CRC molecular subtypes defined by the CRC Subtyping Consortium, making KCNAB2 an interesting pharmacological target. Consistently, its pharmacological inhibition resulted in a dramatic halt in commercial CRC cell proliferation. Identification of potential pharmacologic targets using lipid adduct information emphasizes the great potential of IMS lipidomic techniques in the clinical field.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of Magnetocaloric Heat Pumps in Mobile Air-Conditioning

  • Torregrosa-Jaime, Barbara
  • Vasile-Müller, Carmen
  • Risser, Michel
  • Muller, Christiane
  • Corberán, José M.
  • Payá Herrero, J.
[EN] Air-conditioning (AC) is an important sub-system in electric vehicles (EVs). AC is responsible for the highest energy consumption among all the auxiliary systems. As the energy is delivered by the batteries, the power consumption for airconditioning can imply a significant reduction of the vehicle autonomy. Given the actual state of the art and the temperature and power requirements, electrically driven compressors are the most feasible solution. However, vapour-compression systems are reaching their maximum efficiency. Using innovative technologies can improve the performance of standard systems and hereby increase the vehicle autonomy. This paper presents the first steps in the design of a magnetocaloric air-conditioner for an electric minibus. The system will include two reversible magnetocaloric heat pumps, one in the front part of a minibus and one on the rear. The heat rejection system of the power electronics will be coupled to the air-conditioning system. In order to assist the design of the system, a dynamic model has been developed for the cabin, the hydraulic loops and heat exchangers, and the magnetocaloric units. An integrated design of the complete system is necessary, as it will work under dynamic conditions which depend on the thermal load in the cabin. In this paper, the operation conditions of the magnetocaloric units are presented and the design of the magnetocaloric air-conditioner is discussed. This work has been developed under the frame of the European Project ICE which aims to develop an innovative mobile air-conditioning system for EVs based on a magnetocaloric heat pump., This work has been supported by the European Commission under the 7th European Community framework program as part of the ICE project “MagnetoCaloric Refrigeration for Efficient Electric Air-Conditioning”, Grant Agreement no. 265434. B. Torregrosa-Jaime acknowledges the Spanish Science and Innovation Ministry (Ministerio de Ciencia e Innovación) for receiving the Research Fellowship FPU ref. AP2010-2160.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Generalized analysis of the deposition/splashing limit for one- and two-component droplet impacts upon thin films

  • Bernard, Ronan
  • Foltyn, Patrick
  • Geppert, Anne
  • Lamanna, Grazia
  • Weigand, Bernhard
[EN] Single drop impacts on thin liquid layers are of particular interest because of the ejection of secondary droplets, the so-called splashing. Only a few studies handle the deposition/splashing limit for two-component interaction, where the liquid properties of the impacting drop and wall film differ significantly. This study aims at identifying a unified approach for one- and two-component interactions to determine the deposition/splashing limit. Therefore, a large database of both interactions is considered, which includes data from literature for one-component interactions plus the following binary combinations: hyspin-hexadecane, diesel-hexadecane and diesel-motor oil. Furthermore, a systematic study of two-component interactions with several silicon oils and hexadecane is performed. To map the outcomes, the Ohnesorge number Oh and the Reynolds number Re calculated with arithmetically averaged fluid properties between droplet and wall film fluid are chosen. The dimensionsless film thickness δ is added to form a 3D plot, where one- and two-component experiments are combined. Existing correlations from the literature are revised regarding both interactions and their consistency is checked. The investigated range of high viscosity fluids allow us to propose an improvement of the correlation for high Oh. Our results show that the arithmetically averaged fluid properties lead to a good repartition of both one- and twocomponents interactions toward the deposition/splashing limit. They also corroborate the previous findings that an increase of δ inhibits splashing but its influence is decreasing with increasing Oh., The authors kindly acknowledge the financial support of this work by the Deutsche Forschungsgemeinschaft (DFG) in the frame of the International Research Training Group "Droplet Interaction Technologies" (DROPIT)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of magnetic cooling in electric vehicles

  • Torregrosa Jaime, Bárbara
  • Corberán Salvador, José Miguel
  • Payá-Herrero, Jorge|||0000-0003-2663-3191
The features of an active magnetic regenerator refrigerator (AMRR) are determined for its application in mobile air-conditioning (MAC) systems. The thermal requirements of an electric vehicle have been firstly obtained and result in a cooling demand of 3.03 kW at a temperature span of 29.3 K. A comprehensive parametric study has been conducted in order to find the AMRR design and working parameters that fulfill the vehicle needs with a minimum electric consumption and device mass. Specifically, a permanent-magnet parallel-plate AMRR made of Gd-like materials is considered. According to the possibilities of current prototypes, in the study the cycle frequencies have been limited to 10 Hz and the applied magnetic fields, to 1.4 T. The results show that an AMRR made of plates between 30 and 40 µm thick and channels between 20 and 40 µm high could meet the vehicle demand with a COP between 2 and 4 and a total mass between 20 and 50 kg. Compared to vapor-compression devices for MAC systems (COP=2.5 and mass 12 to 15 kg), the AMRR works optimally with fluid flow rates at least 3 times larger. In order to integrate AMRRs into MAC systems, the hydraulic loops should be consequently redesigned., Barbara Torregrosa-Jaime acknowledges the Spanish Ministry of Education, Culture, and Sport (Ministerio de Educacion, Cultura y Deporte) for the Research Fellowship FPU ref. AP2010-2160.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design of Efficient Air-Conditioning Systems for Electric Vehicles

  • Torregrosa-Jaime, Barbara
  • Corberán, José M.
  • Payá-Herrero, Jorge|||0000-0003-2663-3191
[EN] Among all the auxiliary components in conventional and electric vehicles, air-conditioning (AC) systems present the highest energy consumption. In fully electrical vehicles (FEVs), the heating of the cabin becomes an additional challenge as there is less waste heat available. Therefore, a careful design of the air-conditioning system and of the operation strategies is necessary to reach a reasonable FEV autonomy without compromising the thermal comfort. This paper presents a tool for the design, analysis and optimization of an efficient air-conditioning system for an electric minibus. It consists of dynamic models of each component of the system that have been developed and fully validated individually. Finally, they have been coupled together to simulate the overall vehicle performance of the vehicle in MATLAB-SIMULINK. The core of the system is a water-to-water reversible heat pump with a variable speed compressor. The internal water loop connects the heat pump to the air-coolers inside the cabin while the external water loop is integrated within the heat rejection system of the power electronics. An automatic control system regulates the speed of the compressor, the blowers and the circulation pumps to reach thermal comfort. The power consumption has been analysed under different working conditions and control settings using the overall vehicle model. The latter is a powerful tool not only to design and select MAC equipment, but also to find the most efficient operation strategies., This work has been supported by the European Commission under the 7th European Community framework program as part of the ICE project “MagnetoCaloric Refrigeration for Efficient Electric Air-Conditioning”, Grant Agreement no. 265434.B. Torregrosa-Jaime acknowledges the Spanish Science and Innovation Ministry (Ministerio de Ciencia e Innovación) for receiving the Research Fellowship FPU ref. AP2010-2160.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Key Calibration Strategies for Mitigation of Water Scarcity in the Water Supply Macrosystem of a Brazilian City

  • Rocha, Jefferson S.
  • Uchôa, Jose Gescilam S. M.
  • Brentan, Bruno M.
  • Neto, Iran E. Lima
[EN] This study focuses on Fortaleza, the largest metropolis in Brazil's semi-arid region. Due to recurrent droughts, massive infrastructure like high-density reservoir networks, inter-municipal and interstate water transfer systems, and a seawater desalination plant have been implemented to ensure the city's water security. To evaluate the quantitative and qualitative impact of introducing these diverse water sources into Fortaleza's water supply macrosystem, adequate calibration of the operating and demand parameters is required. In this study, the macrosystem was calibrated using the Particle Swarm Optimization (PSO) method based on hourly data from 50 pressure head monitoring points and 40 flow rate monitoring points over two typical operational days. The calibration process involved adjusting the operational rules of typical valves in large-scale Water Distribution Systems (WDS). After parameterization, the calibration presented the following results: R2 of 88% for pressure head and 96% for flow rate, with average relative errors of 13% for the pressure head and flow rate. In addition, with NSE values above 0.80 after calibration for the flow rate and pressure head, the PSO method suggests a significant improvement in the simulation model's performance. These results offer a methodology for calibrating real WDS to simulate various water injection scenarios in the Fortaleza macrosystem., J.G.S.M.U. acknowledges the S & atilde;o Paulo Research Foundation-FAPESP (Grant 2020/15434-0 and 2023/13160-8) for the scientific and financial support. I.E.L.N. appreciates the financial support from the National Council for Scientific and Technological Development-CNPq (#307680/2023-1) and the Coordination for the Improvement of Higher Education Personnel-CAPES (#2160/2024).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Sizing of a reversible magnetic heat pump for the automotive industry

  • Torregrosa Jaime, Bárbara
  • Corberán Salvador, José Miguel
  • Vasile, C.
  • Muller, C.
  • Risser, M.
  • Payá-Herrero, Jorge|||0000-0003-2663-3191
[EN] This paper focuses on the design of an innovative air-conditioning system, namely a magnetocaloric air-conditioner for an electric minibus. An integrated design of the complete system is necessary, as the hot and cold side of the regenerator will work under dynamic conditions which depend on the instantaneous thermal load in the cabin. In order to assist the design of the system, a dynamic model has been developed for the cabin, the hydraulic loops and heat exchangers, and the magnetocaloric unit. This paper presents (i) a description of the dynamic models, (ii) an analysis of the operating conditions of the magnetocaloric unit and (iii) a discussion on the design of the magnetocaloric air-conditioner. The results show that the electric minibus requests 1.60 kW of cooling power over a span of 37 K in cooling mode, and 3.39 kW of heating power over a span of 40 K., This work has been supported by the European Commission under the 7th European Community framework program as part of the ICE project "MagnetoCaloric Refrigeration for Efficient Electric Air-Conditioning", Grant Agreement no. 265434. B. Torregrosa-Jaime acknowledges the Spanish Science and Innovation Ministry (Ministerio de Ciencia e Innovacion) for receiving the Research Fellowship FPU ref. AP2010-2160.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Transient thermal model of a vehicle&apos, s cabin validated under variable ambient conditions

  • Torregrosa Jaime, Bárbara
  • Bjurling, Filip
  • Corberán Salvador, José Miguel
  • Di Sciullo, Fausto
  • Payá-Herrero, Jorge|||0000-0003-2663-3191
[EN] This paper presents a lumped-parameter thermal model of the passengers' compartment of a vehicle. The model is completely dynamic and has been thoroughly validated under variable ambient conditions including solar radiation. The proposed model reproduces accurately the warm-up and cool-down of the cabin and can help analyse capacity reduction actions for air-conditioning systems. In this study, the thermal loads have been calculated by means of the model. For the tested minibus in real outdoor conditions, air renewal represents from 7% up to 53% of the thermal load, while the solar radiation accounts for 18% 31%. According to the results, a decrease of 0.2 in the glazing transmissivity can lead to a 3.3% reduction of the installed cooling capacity., This work has been supported by the European Commission under the 7th European Community framework program as part of the ICE project "MagnetoCaloric Refrigeration for Efficient Electric Air-Conditioning", Grant Agreement no. 265434. B. Torregrosa-Jaime acknowledges the Spanish Education, Culture and Sport Ministry (Ministerio de Educacion, Cultura y Deporte) for receiving the Research Fellowship FPU ref. AP2010-2160.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Thermal characterisation of compact heat exchangers for air heating and cooling in electric vehicles

  • Torregrosa-Jaime, B.
  • Corberán, José M.
  • Payá-Herrero, Jorge
  • Delamarche, J. L.
[EN] The use of air conditioning in all-electric cars reduces their driving range by 33% in average. With the purpose of reducing the energy consumption of the vehicle and optimising the performance of the batteries, the mobile air-conditioning can be integrated with the temperature control system of the powertrain by means of a coolant loop. In such layouts, the air-to-coolant heat exchangers must operate efficiently in both air heating and cooling modes. Dynamic simulation tools comprising the entire thermal system are essential to assess its performance. In this context, fast but accurate models of the system components are required. This paper presents the thermal characterisation of a commercial compact louvered-fin flat-tube heat exchanger (heater core) for this novel application, based on an experimental campaign comprising 279 working points that reflect real air-conditioning (heating and cooling) working conditions. A general methodology to fit a single correlation of the global heat transfer coefficient for both dry and wet working conditions is explained. The semiempirical correlation developed is employed in a single-node model of the heat exchanger that requires minimal computation time. The present model predicts the heat transfer rate with an average deviation of 3.5% in the cases with dehumidification and 1.9% in the cases when the heat exchanger remains dry., This work has been supported by the European Commission under the 7th European Community framework program as part of the ICE project ‘‘MagnetoCaloric Refrigeration for Efficient Electric Air-Conditioning”, Grant Agreement no. 265434. B. Torregrosa-Jaime acknowledges the Spanish Education, Culture and Sport Ministry (Ministerio de Educación, Cultura y Deporte) for receiving the Research Fellowship FPU ref. AP2010-2160.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An efficient numerical scheme for the simulation of parallel-plate active magnetic regenerators

  • Torregrosa Jaime, Bárbara
  • Corberán Salvador, José Miguel
  • Engelbrecht, Kurt
  • Payá-Herrero, Jorge|||0000-0003-2663-3191
A one-dimensional model of a parallel-plate active magnetic regenerator (AMR) is presented in this work. The model is based on an efficient numerical scheme which has been developed after analysing the heat transfer mechanisms in the regenerator bed. The new finite difference scheme optimally combines explicit and implicit techniques in order to solve the one-dimensional conjugate heat transfer problem in an accurate and fast manner while ensuring energy conservation. The present model has been thoroughly validated against passive regenerator cases with an analytical solution. Compared to the fully implicit scheme, the proposed scheme achieves more accurate results, prevents numerical errors and requires less computational effort. In AMR simulations the new scheme can reduce the computational time by 89%., B. Torregrosa-Jaime acknowledges the Spanish Ministry of Education, Culture and Sport (Ministerio de Educacion, Cultura y Deporte) for receiving the Research Fellowship FPU ref. AP2010-2160.