Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Transient detection of eccentricity-related components in induction motors through the Hilbert-Huang Transform

  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • Jover Rodríguez, Pedro Vicente
  • Arkkio, Antero
  • Roger-Folch, José
  • Pérez, R.B.
[EN] The identification and extraction of characteristic patterns are proposed in this work for the diagnosis and evaluation of mixed eccentricities in induction electrical machines with parallel stator branches. Whereas the classical diagnosis approaches, deeply spread in the industrial environment, are based on the Fourier analysis of the steady-state current, the basis of the proposed methodology consist of analysing the current demanded by the machine during the connection process (startup transient); the objective is to extract the characteristic evolution during the transient of some harmonic components created by the fault; this evolution is caused by the dependence of these components on the slip (s), a quantity varying during the startup transient from 1 to almost 0. For this feature extraction. the Hilbert-Huang Transform (HHT) is proposed. An analysis of the-behaviour of this transform in comparison with another time-frequency approach used in other works, the Discrete Wavelet Transform (DWT), is also presented in the paper. The results show the usefulness of the methodology for the reliable diagnosis of the mixed eccentricity fault and for the correct discrimination against other types of failures. (C) 2009 Elsevier Ltd. All rights reserved., The research leading to these results has received funding from the European Community's Seventh Framework Programme FP7/2007-2013 under Grant Agreement no. 224233 (Research Project PRODI "Power plant Robustification based on fault Detection and Isolation algorithms"). The authors also thank Vicerrectorado de Investigacion, Desarrollo e Innovacion of Universidad Politecnica de Valencia for financing a part of this research through the program Programa de Apoyo a la Investigacion y Desarrollo (PAID-06-07).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Support vector machine classifier for diagnosis in electrical machines: Application to broken bar

  • Matic, Dragan
  • Kulic, Filip
  • Kamenko, Ilija
  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
[EN] This paper presents a support vector machine classifier for broken bar detection in electrical induction machine. It is a reliable online method, which has high robustness to load variations and changing operating conditions. The phase current is only physical value to be measured. The steady state current is analyzed for broken bar fault via motor current signature analysis technique based on Hilbert transform. A two dimensional feature space is proposed. The features are: magnitude and frequency of characteristic peak extracted from spectrum of Hilbert transform series of the phase current. For classification task support vector machine is used due to its good robustness and generalization performances. A comparative analysis of linear, Gaussian and quadratic kernel function versus error rate and number of support vectors is done. The proposed classifier successfully detects a broken bar in various operational situations. The proposed method is sufficiently accurate, fast, and robust to load changes, which makes it suitable for use in real-time online applications in industrial drives., This paper is produced as a result of work on FP7 project for area of information and communication technologies named "PRODI - Power plants Robustification based on fault Detection and Isolation algorithms" contract number 224233 financed from European Comity, General Manager for Information community and Media.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improved Resolution of the MCSA Method Via Hilbert Transform, Enabling the Diagnosis of Rotor Asymmetries at Very Low Slip

  • Puche-Panadero, Rubén|||0000-0003-2090-1941
  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • Hurtado-Perez, Elias|||0000-0001-8909-0679
  • Roger-Folch, José
  • Pérez-Cruz, Juan
[EN] This paper proposes an online/offline induction motor current signature analysis (MCSA) with advanced signal-and-data-processing algorithms, based on the Hilbert transform. MCSA is a method for motor diagnosis with stator-current signals. Although it is one of the most powerful online methods for diagnosing motor faults, it has some drawbacks that can degrade the performance and accuracy of a motor-diagnosis system. In particular, it is very difficult to detect broken rotor bars when the motor is operating at low slip or under no load, due to fast Fourier transform (FFT) frequency leakage and the small amplitude of the current components related to the fault. Therefore, advanced signal-and-data-processing algorithms are proposed. They consist of a proper sample selection algorithm, a Hilbert transformation of the stator-sampled current, and spectral analysis via FFT of the modulus of the resultant time-dependent vector modulus for achieving MCSA efficiently. Experimental results obtained on a 1.1-kW three-phase squirrel-cage induction motor are discussed., This work was supported in part by European Community's Seventh Framework Program FP7/2007-2013 under Grant Agreement 224233 (Research Project PRODI "Power plant Robustification based on fault Detection and Isolation algorithms"), in part by the Spanish "Ministerio de Educacion y Ciencia", in the framework of the "Programa Nacional de proyectos de Investigacion Fundamental", project reference DP12008-06583/DPI.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Feature Extraction for the Prognosis of Electromechanical Faults in Electrical Machines through the DWT

  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Pons Llinares, Joan|||0000-0003-3756-1242
  • Puche-Panadero, Rubén|||0000-0003-2090-1941
  • Pérez-Cruz, Juan
[EN] Recognition of characteristic patterns is proposed in this paper in order to diagnose the presence of electromechanical faults in induction electrical machines. Two common faults are considered; broken rotor bars and mixed eccentricities. The presence of these faults leads to the appearance of frequency components following a very characteristic evolution during the startup transient. The identification and extraction of these characteristic patterns through the Discrete Wavelet Transform (DWT) have been proven to be a reliable methodology for diagnosing the presence of these faults, showing certain advantages in comparison with the classical FFT analysis of the steady-state current. In the paper, a compilation of healthy and faulty cases are presented; they confirm the validity of the approach for the correct diagnosis of a wide range of electromechanical faults., The research leading to these results has received funding from the European Community's Seventh Framework Programme FP7/2007-2013 under Grant Agreement n° 224233 (Research Project PRODI “Power plant Robustification based on fault Detection and Isolation algorithms”). The authors also thank ‘Vicerrectorado de Investigación, Desarrollo e Innovación of Universidad Politécnica de Valencia’ for financing a part of this research through the program ‘Programa de Apoyo a la Investigación y Desarrollo (PAID-06-07).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Diagnosis of Induction Motor Faults in the Fractional Fourier Domain

  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Puche-Panadero, Rubén|||0000-0003-2090-1941
  • Roger-Folch, José
  • Perez-Cruz, Juan
[EN] Motor current signature analysis (MCSA) is a well-established method for the diagnosis of induction motor faults. It is based on the analysis of the spectral content of a motor current, which is sampled while a motor runs in steady state, to detect the harmonic components that characterize each type of fault. The Fourier transform (FT) plays a prominent role as a tool for identifying these spectral components. Recently, MCSA has also been applied during the transient regime (TMCSA) using the whole transient speed range to create a unique stamp of each harmonic as it evolves in the time-frequency plane. This method greatly enhances the reliability of the diagnostic process compared with the traditional method, which relies on spectral analysis at a single speed. However, the FT cannot be used in this case because the fault harmonics are not stationary signals. This paper proposes the use of the fractional FT (FrFT) instead of the FT to perform TMCSA. This paper also proposes the optimization of the FrFT to generate a spectrum where the frequency-varying fault harmonics appear as single spectral lines and, therefore, facilitate the diagnostic process. A discrete wavelet transform (DWT) is used as a conditioning tool to filter the motor current prior to its processing by the FrFT. Experimental results that are obtained with a 1.1-kW three-phase squirrel-cage induction motor with broken bars are presented to validate the proposed method., This work was supported by the European Community's Seventh Framework Program FP7/2007-2013 under Grant Agreement 224233 (Research Project PRODI "Power Plant Robustification Based on Fault Detection and Isolation Algorithms"). The Associate Editor coordinating the review process for this paper was Dr. Subhas Mukhopadhyay.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A critical comparison between DWT and Hilbert-Huang-based methods for the diagnosis of rotor bar failures in induction machines

  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Pérez, Rafael B.
[EN] In this paper, a cutting-edge time-frequency decomposition tool, i.e., the Hilbert-Huang transform (HHT), is applied to the stator startup current to diagnose the presence of rotor asymmetries in induction machines. The objective is to extract the evolution during the startup transient of the left sideband harmonic (LSH) caused by the asymmetry, which constitutes a reliable evidence of the presence of the fault. The validity of the diagnosis methodology is assessed through several tests developed using real experimental signals. Moreover, in this paper, an analytical comparison with an alternative time-frequency decomposition tool, i.e., the discrete wavelet transform (DWT), is carried out. This tool was applied in previous works to the transient extraction of fault-related components, with satisfactory results, even in cases in which the classical Fourier approach does not lead to correct results. The results of the application of the HHT and DWT are analyzed and compared, obtaining novel conclusions about their respective suitability for the transient extraction of asymmetry-related components, as well as the equivalence, with regard to the LSH extraction, between their basic components, namely: 1) intrinsic mode function, for the HHT, and 2) approximation signal for the DWT., This work was supported in part by the Spanish “Ministerio de Educación y Ciencia,” in the framework of the “Programa Nacional de proyectos de Investigación Fundamental,” project reference DPI2008-06583/DPI and in part by “Vicerrectorado de Investigación, Desarrollo e Innovación of the Universidad Politécnica de Valencia” through the Programa de Apoyo a la Investigación y Desarrollo under Contract PAID-06-07.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Detection of combined faults in induction machines with stator parallel branches through the DWT of the startup current

  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Jover Rodriguez, P.
  • Arkkio, A.
[EN] The main objective of this paper is to diagnose the presence of combined faults in induction machines. For this purpose, a methodology based on the application of the Discrete Wavelet Transform (DWT) to the stator startup current is used. This approach was applied in previous works with success to the diagnosis of rotor asymmetries and mixed eccentricities in motors with different sizes and conditions. However, as most of the diagnosis methods hitherto developed, the application of the proposed approach was circumscribed to situations in which a single fault was present in the machine. In addition, the influence of other phenomena such as load torque oscillations or voltage fluctuations was studied, but without considering the combination of these phenomena and the fault in the machine. This work is intended, first, to apply the proposed transient-based methodology to several cases in which different faults (rotor asymmetries, mixed eccentricities and inter-turn and inter-coil stator short-circuits) are simultaneously present in the machine and, second, to apply it to cases regarding faults combined with other phenomena making difficult the diagnosis, such as load torque oscillations. Interesting considerations regarding the preponderance of the effects of some of the faults are also done in the paper. The application of the methodology is focused on induction machines with stator parallel branches; in this sense, the suitability of the use either of the phase current or of the branch current for the diagnosis of each particular fault is analysed. The results look promising with regard to the validity of the methodology for the reliable discrimination of simultaneous electromechanical faults and the diagnosis of faults combined with other phenomena. (C) 2009 Elsevier Ltd. All rights reserved., This work was supported by the Conselleria d'Educacio, Formacio i Ocupacio of the Generalitat Valenciana, in the framework of the "Ayudas para la Realizacion de Proyectos de I + D para Grupos de Investigacion Emergentes", project reference GV/2012/020.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Calculation of Winding Inductances via Magnetic Vector Potential, Discrete Convolution and Fast Fourier Transform

  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • Puche-Panadero, Rubén|||0000-0003-2090-1941
  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Pons Llinares, Joan|||0000-0003-3756-1242
  • Roger-Folch, José
  • Pérez-Cruz, Juan
[Otro] Przedstawiono analiz¿ uszkodze¿ silnika indukcyjnego spowodowanych z¿amaniem pr¿tu, lub zwarciem wewn¿trznym. Oszacowano amplitud¿ wynikaj¿c¿ z uszkodzenia. Induktancja uzwoje¿ jest kluczowa w tym modelu. Zaproponowana metoda jest bardzo prosta i szybka. Zastosowano wektorowy potencja¿ magnetyczny oraz szybk¿ transformat¿ Fouriera., [EN] Fault analysis of induction motors with broken bars or inter-turn short circuits needs accurate machine models to correctly identify and quantify the magnitude of the fault. Winding inductances and their derivatives are a key component of these models. In this paper a new, very easy and extremely fast method to compute them, based on the Magnetic Vector Potential (MVP), the Discrete Circular Convolution and the Fast Fourier Transform (FFT), is presented., This work was supported by the European Community's Seventh Framework Program FP7/2007-2013 under Grant Agreement 224233 (Research Project PRODI "Power Plant Robustification based on Fault Detection and Isolation Algorithms")
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A General Approach for the Transient Detection of Slip-Dependent Fault Components Based on the Discrete Wavelet Transform

  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Puche-Panadero, Rubén|||0000-0003-2090-1941
  • Pérez-Cruz, Juan
[EN] In this paper, a general methodology based on the application of discrete wavelet transform (DWT) to the diagnosis of the cage motor condition using transient stator currents is exposed. The approach is based on the identification of characteristic patterns introduced by fault components in the wavelet signals obtained from the DWT of transient stator currents. These patterns enable a reliable detection of the corresponding fault as well as a clear interpretation of the physical phenomenon taking place in the machine. The proposed approach is applied to the detection of rotor asymmetries in two alternative ways, i.e., by using the startup current and by using the current during plugging stopping. Mixed eccentricities are also detected by means of the transient-based methodology. This paper shows how the evolution of other non-fault-related components such as the principal slot harmonic (PSH) can be extracted with the proposed technique. A compilation of experimental cases regarding the application of the methodology to the previous cases is presented. Guidelines for the easy application of the methodology by any user are also provided under a didactic perspective., This work was supported by the European Community’s Seventh Framework Program FP7/2007-2013 under Grant Agreement 224233 (Research Project PRODI “Power plant Robustification based on fault Detection and Isolation algorithms”).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Instantaneous Frequency of the Left Sideband Harmonic During the Start-Up Transient: A New Method for Diagnosis of Broken Bars

  • Manuel Pineda-Sanchez|||0000-0001-7844-8831
  • Riera-Guasp, Martín|||0000-0003-1327-242X
  • J. Antonino-Daviu|||0000-0003-1898-2228
  • Puche-Panadero, Rubén|||0000-0003-2090-1941
  • Roger-Folch, José
  • Perez-Cruz, Juan
[EN] In this paper, a new method for detecting the presence of broken rotor bars is presented. The proposed approach is valid for induction machines started at constant frequency and consists of extracting the instantaneous frequency (IF) of the left sideband harmonic (LSH) from the start-up current (LSHst), via the Hilbert transform. It is shown that, in the case of machines with one or several broken bars, the IF of the LSHst exhibits a very characteristic and easy to identify pattern, which is physically justified. This paper also shows that, if the IF of the LSHst is represented against the slip, a universal fault indicator (nondependent neither on the machine characteristics nor on the starting conditions) can be defined. This fault indicator consists of the correlation between the experimental IF of the LSHst and its theoretical evolution. This approach is theoretically introduced and experimentally validated by testing a commercial motor in faulty and healthy conditions, under different operating conditions., This work was supported by the European Community’s Seventh Framework Program FP7/2007-2013 under Grant Agreement 224233 [Research Project “Power Plant Robustification based on fault Detection and Isolation (PRODI) algorithms”].