Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Temporal diffeomorphic free-form deformation: application to motion and strain estimation from 3D echocardiography

  • Craene, Mathieu de
  • Piella Fenoy, Gemma
  • Camara, Oscar
  • Duchateau, Nicolas
  • Silva, Etelvino
  • Doltra, Adelina
  • D'hooge, Jan
  • Brugada, Josep
  • Sitges, Marta
  • Frangi Caregnato, Alejandro
This paper presents a new registration algorithm, called Temporal Di eomorphic Free Form Deformation (TDFFD), and its application to motion and strain quanti cation from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity eld as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement eld is then recovered through forward Eulerian integration of the non-stationary velocity eld. The strain tensor is/ncomputed locally using the spatial derivatives of the reconstructed displacement eld. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared di erences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on the/nincompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, both/non displacement and velocity elds, on a set of synthetic 3D US images with di erent noise levels. TDFFD/nshowed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFD/nwas applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, the/nimprovement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quanti ed by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT., This research has been partially funded by the Spanish Industrial and Technological Development Center (CDTI) under the CENIT Programme (cvREMOD Project), the Spanish Ministry of Science and Innovation (MICINN) and the European Regional Development Fund (ERDF) through the research project STIMATH (TIN2009-14536-C02-01), and the European Community’s Seventh Framework Program (FP7/2007-2013) under the euHeart project (FP7-ICT-2007-2-224495).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Effects of the Purkinje system and cardiac geometry on biventricular pacing: a model study

  • Romero García, Daniel
  • Sebastián Aguilar, Rafael, 1978-
  • Bijnens, Bart
  • Zimmerman, Viviana
  • Boyle, Patrick M.
  • Vigmond, Edward J.
  • Frangi Caregnato, Alejandro
Heart failure leads to gross cardiac structural changes. While cardiac resynchronization therapy (CRT) is a recognized treatment for restoring synchronous activation, it is not clear how changes in cardiac shape and size affect the electrical pacing therapy. This study used a human heart computer model which incorporated anatomical structures such as myofiber orientation and a Purkinje system (PS) to study how pacing affected failing hearts. The PS was modeled as a tree structure that reproduced its retrograde activation feature. In addition to a normal geometry, two cardiomyopathies were modeled: dilatation and hypertrophy. A biventricular pacing protocol was tested in the context of atrio-ventricular block. The contribution of the PS was examined by removing it, as well as by increasing endocardial conductivity. Results showed that retrograde conduction into the PS was a determining factor for achieving intraventricular synchrony. Omission of the PS led to an overestimate of the degree of electrical dyssynchrony while assessing CRT. The activation patterns for the three geometries showed local changes in the order of activation of the lateral wall in response to the same pacing strategy. These factors should be carefully considered when determining lead placement and optimizing device parameters in clinical practice., This research has been partially funded by the Industrial and Technological Development Center (CDTI) under the CENIT Programme (CDTEAM Project) and the European Community’s Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 224495 (euHeart Project). Dr. R. Sebastian was funded by the Ministerio de Ciencia e Innovacion (Juan de la Cierva program). Dr. B. Bijnens is an ICREA Research Professor at Universitat Pompeu Fabra. Dr. E. Vigmond and P. Boyle were funded by The Natural Sciences and Engineering Research Council of Canada. P. Boyle is supported by the Alberta Ingenuity Fund.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Cardiac motion estimation by joint alignment of tagged MRI sequences

  • Oubel, E.
  • Craene, Mathieu de
  • Hero, A.O.
  • Pourmorteza, A.
  • Huguet, Marina
  • Avegliano, Gustavo P.
  • Bijnens, Bart
  • Frangi Caregnato, Alejandro
Image registration has been proposed as an automatic method for recovering cardiac displacement fields from Tagged Magnetic Resonance Imaging (tMRI) sequences. Initially performed as a set of pairwise registrations, these techniques have evolved to the use of 3D+t deformation models, requiring metrics of joint image alignment (JA). However, only linear combinations of cost functions defined with respect to the first frame have been used. In this paper, we have applied k-Nearest Neighbors Graphs (kNNG) estimators of the -entropy (H ) to measure the joint similarity between frames, and to combine the information provided by different cardiac views in an unified metric. Experiments performed on six subjects showed a significantly higher accuracy (p < 0.05) with respect to a standard pairwise alignment (PA) approach in terms of mean positional error and variance with respect to manually placed landmarks. The developed method was used to study strains in patients with myocardial infarction, showing a consistency between strain, infarction location, and coronary occlusion. This paper also presents/nan interesting clinical application of graph-based metric estimators, showing their value for solving practical problems found in medical imaging.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Characterization of myocardial deformation in patients with different etiologies of left ventricular hypertrophy by using strain distribution from Magnetic Resonance Imaging, Caracterización de la deformación miocárdica en pacientes con hipertrofia ventricular izquierda de diferente etiología/nmediante el uso de distribuciones de strain obtenidas de imágenes de resonancia magnética

  • Piella Fenoy, Gemma
  • Craene, Mathieu de
  • Bijnens, Bart
  • Tobón Gómez, Catalina, 1981-
  • Huguet, Marina
  • Avegliano, Gustavo P.
  • Frangi Caregnato, Alejandro
Introducción y objetivos. Se ha señalado que, en la miocardiopatía hipertrófica (MCH), la desorganización de las fibras regionales da lugar a segmentos en los que la deformación es nula o está gravemente reducida, y que estos segmentos tienen una distribución no uniforme en el ventrículo izquierdo (VI). Esto contrasta con lo observado en otros tipos de hipertrofia como en el corazón de atleta o la hipertrofia ventricular izquierda hipertensiva (HVI-HT), en los que puede haber una deformación cardiaca anormal, pero nunca tan reducida como para que se observe ausencia de deformación. Así pues, proponemos el empleo de la distribución de los valores de strain para estudiar la deformación en la MCH. Métodos. Con el empleo de resonancia magnética marcada (tagged), reconstruimos la deformación sistólica del VI de 12 sujetos de control, 10 atletas, 12 pacientes con MCH y 10 pacientes con HVI-HT. La deformación se cuantificó con un algoritmo de registro no rígido y determinando los valores de strain sistólico máximo radial y circunferencial en 16 segmentos del VI. Resultados. Los pacientes con MCH presentaron unos valores medios de strain significativamente inferiores a los de los demás grupos. Sin embargo, aunque la deformación observada en los individuos sanos y en los pacientes con HVI-HT se concentraba alrededor del valor medio, en la MCH coexistían segmentos con contracción normal y segmentos con una deformación nula o significativamente reducida, con lo que se producía una mayor heterogeneidad de los valores de strain. Se observaron también algunos segmentos sin deformación incluso en ausencia de fibrosis o hipertrofia. Conclusiones. La distribución de strain caracteriza los patrones específicos de deformación miocárdica en pacientes con diferentes etiologías de la HVI. Los pacientes con MCH presentaron un valor medio de strain significativamente inferior, así como una mayor heterogeneidad de strain (en comparación con los controles, los atletas y los pacientes con HVI-HT), y tenían regiones sin deformación., Introduction and objectives. It has been suggested that in hypertrophic cardiomyopathy (HCM) the regional fibre disarray results in segments of none or severely reduced deformation, distributed non-uniformly within the left ventricle (LV). This is in contrast with other types of hypertrophies such as athlete’s heart or hypertensive left ventricular hypertrophy (HT-LVH) which may have abnormal cardiac deformation but never as reduced as showing absence of deformation in certain segments. Hence, we propose to use the distribution of the strain values to study deformation in HCM./nMethods. Using tagged magnetic resonance imaging, we reconstructed the LV systolic deformation from 12/ncontrols, 10 athletes, 12 patients with HCM and 10 patients with HT-LVH. Deformation was quantified using a fast nonrigid registration algorithm and measuring radial and circumferential peak systolic strain values from 16 LV segments./nResults. HCM patients showed significantly lower average strain values when compared to other groups./nHowever, while the deformation in healthy subjects and HT-LVH was concentrated around the mean value, in HCM there was a coexistence of segments with normal contraction and segments with none or significantly reduced deformation, resulting in a larger heterogeneity of the strain values. Some non-deforming segments were also found in the absence of fibrosis or hypertrophy./nConclusions. Strain distribution characterizes specific patterns of myocardial deformation in patients with/ndifferent etiologies of LVH. HCM patients had significantly lower average strain as well as/n2larger strain heterogeneity (compared to controls, athletes and HT-LVH), and they presented non-deforming regions., This work was partially funded by the Industrial and Technological Development Centre (CDTI) under the CENIT Programme (CDTEAM project) and the European Community's Seventh Framework Programme (FP7/2007-2013) [grant number 224495] (euHeart project). G. Piella was supported by the Ramón y Cajal Programme from the Spanish Ministry of Science and Innovation.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Temporal diffeomorphic free-form deformation: application to motion and strain estimation from 3D echocardiography

  • Craene, Mathieu De
  • Piella, Gemma
  • Camara, Oscar
  • Duchateau, Nicolas
  • Silva, Etelvino
  • Doltra, Adelina
  • D&apos;hooge, Jan
  • Brugada Terradellas, Josep, 1958-
  • Sitges Carreño, Marta
  • Frangi, Alejandro F.
This paper presents a new registration algorithm, called Temporal Diffeomorphic Free Form Deformation (TDFFD), and its application to motion and strain quantification from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity field as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement field is then recovered through forward Eulerian integration of the non-stationary velocity field. The strain tensor is computed locally using the spatial derivatives of the reconstructed displacement field. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared differences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on the incompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, both on displacement and velocity fields, on a set of synthetic 3D US images with different noise levels. TDFFD showed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFD was applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, the improvement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quantified by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: Comparison between complete and intermediate beginners and experienced observers

  • Hedström, Erik
  • Ishida, Masaki
  • Sepúlveda-Martínez, Alvaro
  • Salehi, Daniel
  • Sperling, Johannes
  • Engblom, Henrik
  • Nagel, Eike
[Background] High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR., [Methods] Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods., [Results] Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching., [Conclusions] Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required., This work was supported by a European Union Grant (224495); the British Heart Foundation (Research Excellence Award RE/08/003 and FS/10/029/ 28253); the Biomedical Research Centre (BRC-CTF 196); the Wellcome Trust and EPSRC (WT 088641/Z/09/Z); Lund University Medical Faculty and Lund University Hospital, Sweden; the Foundation BLANCEFLOR BoncompagniLudovisi, née Bildt, Sweden; and the Swedish societies of Medicine, Cardiology, and Radiology; the Erasmus Mundus + Programme of the European Union (Framework Agreement number: 2013–0040); and the German Centre for Cardiovascular Research (DZHK)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Patient-specific non-invasive estimation of pressure gradient across aortic coarctation using magnetic resonance imaging

  • Shi, Yubing
  • Valverde, Israel
  • Lawford, Patricia V.
  • Beerbaum, Philipp
  • Hose, Rodney
[Background] Non-invasive estimation of the pressure gradient in aortic coarctation has much clinical importance in assisting the diagnosis and treatment of the disease. Previous researchers applied computational fluid dynamics for the prediction of the pressure gradient in aortic coarctation. The accuracy of the prediction was satisfactory but the procedure was time-consuming and resource-demanding., [Method] In this research a magnetic resonance imaging (MRI)-based non-invasive modeling procedure is implemented to predict the pressure gradient in 14 patient cases of aortic coarctation. Multi-cycle patient flow and pressure data are processed to produce the flow and pressure conditions in the patient cases. Bernoulli equation-based friction loss model combined with the inertial effect of the blood flow in the vessel segments are applied to model the pressure gradient in the aortic coarctation. The model-predicted pressure gradient data are then compared with the catheter in vivo measurement data for validation., [Results] The MRI-based model prediction technique produces results that are consistent with those from the catheter measurement, based on the criteria of both the cycle-averaged instantaneous pressure gradient and the peak-to-peak pressure gradient., [Conclusion] This study suggests that the MRI-based non-invasive modeling procedure has much potential to be applied in clinical practice for the prediction of the pressure gradient in aortic coarctation patients., This research was supported by the European Commission's Seventh Framework Programme (FP7/2007-2013) under the grant agreement number 224495 (euHeart project)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Comparison of stenosis models for usage in the estimation of pressure gradient across aortic coarctation

  • Shi, Yubing
  • Valverde, Israel
  • Lawford, Patricia V.
  • Grotenhuis, Heynric B.
  • Beerbaum, Philipp
  • Hose, Rodney
Non-invasive estimation of the pressure gradient in cardiovascular stenosis has much clinical importance in assisting the diagnosis and treatment of stenotic diseases. In this research, a systematic comparison is conducted to investigate the accuracy of a group of stenosis models against the MRI- and catheter-measured patient data under the aortic coarctation condition. Eight analytical stenosis models, including six from the literature and two proposed in this study, are investigated to examine their prediction accuracy against the clinical data. The two improved models proposed in this study consider comprehensively the Poiseuille loss, the Bernoulli loss in its exact form, and the entrance effect, of the blood flow. Comparison of the results shows that one of the proposed models demonstrates a cycle-averaged mean prediction error of −0.15 ± 3.03 mmHg, a peak-to-peak prediction error of −1.8 ± 6.89 mmHg, which is the best among the models studied., This research was funded by the European Community’s Seventh Framework Programme (FP7/2007–2013) under the grant agreement number 224495 (euHeart project).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Characterization of myocardial deformation in patients with different etiologies of left ventricular hypertrophy by using strain distribution from Magnetic Resonance Imaging, Caracterización de la deformación miocárdica en pacientes con hipertrofia ventricular izquierda de diferente etiología/nmediante el uso de distribuciones de strain obtenidas de imágenes de resonancia magnética

  • Piella Fenoy, Gemma
  • Craene, Mathieu de
  • Bijnens, Bart
  • Tobón Gómez, Catalina, 1981-
  • Huguet, Marina
  • Avegliano, Gustavo P.
  • Frangi Caregnato, Alejandro
Introducción y objetivos. Se ha señalado que, en la miocardiopatía hipertrófica (MCH), la desorganización de las fibras regionales da lugar a segmentos en los que la deformación es nula o está gravemente reducida, y que estos segmentos tienen una distribución no uniforme en el ventrículo izquierdo (VI). Esto contrasta con lo observado en otros tipos de hipertrofia como en el corazón de atleta o la hipertrofia ventricular izquierda hipertensiva (HVI-HT), en los que puede haber una deformación cardiaca anormal, pero nunca tan reducida como para que se observe ausencia de deformación. Así pues, proponemos el empleo de la distribución de los valores de strain para estudiar la deformación en la MCH. Métodos. Con el empleo de resonancia magnética marcada (tagged), reconstruimos la deformación sistólica del VI de 12 sujetos de control, 10 atletas, 12 pacientes con MCH y 10 pacientes con HVI-HT. La deformación se cuantificó con un algoritmo de registro no rígido y determinando los valores de strain sistólico máximo radial y circunferencial en 16 segmentos del VI. Resultados. Los pacientes con MCH presentaron unos valores medios de strain significativamente inferiores a los de los demás grupos. Sin embargo, aunque la deformación observada en los individuos sanos y en los pacientes con HVI-HT se concentraba alrededor del valor medio, en la MCH coexistían segmentos con contracción normal y segmentos con una deformación nula o significativamente reducida, con lo que se producía una mayor heterogeneidad de los valores de strain. Se observaron también algunos segmentos sin deformación incluso en ausencia de fibrosis o hipertrofia. Conclusiones. La distribución de strain caracteriza los patrones específicos de deformación miocárdica en pacientes con diferentes etiologías de la HVI. Los pacientes con MCH presentaron un valor medio de strain significativamente inferior, así como una mayor heterogeneidad de strain (en comparación con los controles, los atletas y los pacientes con HVI-HT), y tenían regiones sin deformación., Introduction and objectives. It has been suggested that in hypertrophic cardiomyopathy (HCM) the regional fibre disarray results in segments of none or severely reduced deformation, distributed non-uniformly within the left ventricle (LV). This is in contrast with other types of hypertrophies such as athlete’s heart or hypertensive left ventricular hypertrophy (HT-LVH) which may have abnormal cardiac deformation but never as reduced as showing absence of deformation in certain segments. Hence, we propose to use the distribution of the strain values to study deformation in HCM./nMethods. Using tagged magnetic resonance imaging, we reconstructed the LV systolic deformation from 12/ncontrols, 10 athletes, 12 patients with HCM and 10 patients with HT-LVH. Deformation was quantified using a fast nonrigid registration algorithm and measuring radial and circumferential peak systolic strain values from 16 LV segments./nResults. HCM patients showed significantly lower average strain values when compared to other groups./nHowever, while the deformation in healthy subjects and HT-LVH was concentrated around the mean value, in HCM there was a coexistence of segments with normal contraction and segments with none or significantly reduced deformation, resulting in a larger heterogeneity of the strain values. Some non-deforming segments were also found in the absence of fibrosis or hypertrophy./nConclusions. Strain distribution characterizes specific patterns of myocardial deformation in patients with/ndifferent etiologies of LVH. HCM patients had significantly lower average strain as well as/n2larger strain heterogeneity (compared to controls, athletes and HT-LVH), and they presented non-deforming regions., This work was partially funded by the Industrial and Technological Development Centre (CDTI) under the CENIT Programme (CDTEAM project) and the European Community's Seventh Framework Programme (FP7/2007-2013) [grant number 224495] (euHeart project). G. Piella was supported by the Ramón y Cajal Programme from the Spanish Ministry of Science and Innovation.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Temporal diffeomorphic free-form deformation: application to motion and strain estimation from 3D echocardiography

  • Craene, Mathieu De
  • Piella, Gemma
  • Camara, Oscar
  • Duchateau, Nicolas
  • Silva, Etelvino
  • Doltra, Adelina
  • D'hooge, Jan
  • Brugada Terradellas, Josep, 1958-
  • Sitges Carreño, Marta
  • Frangi, Alejandro F.
This paper presents a new registration algorithm, called Temporal Diffeomorphic Free Form Deformation (TDFFD), and its application to motion and strain quantification from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity field as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement field is then recovered through forward Eulerian integration of the non-stationary velocity field. The strain tensor is computed locally using the spatial derivatives of the reconstructed displacement field. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared differences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on the incompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, both on displacement and velocity fields, on a set of synthetic 3D US images with different noise levels. TDFFD showed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFD was applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, the improvement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quantified by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Cardiac motion estimation by joint alignment of tagged MRI sequences

  • Oubel, E.
  • Craene, Mathieu de
  • Hero, A.O.
  • Pourmorteza, A.
  • Huguet, Marina
  • Avegliano, Gustavo P.
  • Bijnens, Bart
  • Frangi Caregnato, Alejandro
Image registration has been proposed as an automatic method for recovering cardiac displacement fields from Tagged Magnetic Resonance Imaging (tMRI) sequences. Initially performed as a set of pairwise registrations, these techniques have evolved to the use of 3D+t deformation models, requiring metrics of joint image alignment (JA). However, only linear combinations of cost functions defined with respect to the first frame have been used. In this paper, we have applied k-Nearest Neighbors Graphs (kNNG) estimators of the -entropy (H ) to measure the joint similarity between frames, and to combine the information provided by different cardiac views in an unified metric. Experiments performed on six subjects showed a significantly higher accuracy (p < 0.05) with respect to a standard pairwise alignment (PA) approach in terms of mean positional error and variance with respect to manually placed landmarks. The developed method was used to study strains in patients with myocardial infarction, showing a consistency between strain, infarction location, and coronary occlusion. This paper also presents/nan interesting clinical application of graph-based metric estimators, showing their value for solving practical problems found in medical imaging.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Effects of the Purkinje system and cardiac geometry on biventricular pacing: a model study

  • Romero García, Daniel
  • Sebastián Aguilar, Rafael, 1978-
  • Bijnens, Bart
  • Zimmerman, Viviana
  • Boyle, Patrick M.
  • Vigmond, Edward J.
  • Frangi Caregnato, Alejandro
Heart failure leads to gross cardiac structural changes. While cardiac resynchronization therapy (CRT) is a recognized treatment for restoring synchronous activation, it is not clear how changes in cardiac shape and size affect the electrical pacing therapy. This study used a human heart computer model which incorporated anatomical structures such as myofiber orientation and a Purkinje system (PS) to study how pacing affected failing hearts. The PS was modeled as a tree structure that reproduced its retrograde activation feature. In addition to a normal geometry, two cardiomyopathies were modeled: dilatation and hypertrophy. A biventricular pacing protocol was tested in the context of atrio-ventricular block. The contribution of the PS was examined by removing it, as well as by increasing endocardial conductivity. Results showed that retrograde conduction into the PS was a determining factor for achieving intraventricular synchrony. Omission of the PS led to an overestimate of the degree of electrical dyssynchrony while assessing CRT. The activation patterns for the three geometries showed local changes in the order of activation of the lateral wall in response to the same pacing strategy. These factors should be carefully considered when determining lead placement and optimizing device parameters in clinical practice., This research has been partially funded by the Industrial and Technological Development Center (CDTI) under the CENIT Programme (CDTEAM Project) and the European Community’s Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 224495 (euHeart Project). Dr. R. Sebastian was funded by the Ministerio de Ciencia e Innovacion (Juan de la Cierva program). Dr. B. Bijnens is an ICREA Research Professor at Universitat Pompeu Fabra. Dr. E. Vigmond and P. Boyle were funded by The Natural Sciences and Engineering Research Council of Canada. P. Boyle is supported by the Alberta Ingenuity Fund.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Temporal diffeomorphic free-form deformation: application to motion and strain estimation from 3D echocardiography

  • Craene, Mathieu de
  • Piella Fenoy, Gemma
  • Camara, Oscar
  • Duchateau, Nicolas
  • Silva, Etelvino
  • Doltra, Adelina
  • D&apos;hooge, Jan
  • Brugada, Josep
  • Sitges, Marta
  • Frangi Caregnato, Alejandro
This paper presents a new registration algorithm, called Temporal Di eomorphic Free Form Deformation (TDFFD), and its application to motion and strain quanti cation from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity eld as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement eld is then recovered through forward Eulerian integration of the non-stationary velocity eld. The strain tensor is/ncomputed locally using the spatial derivatives of the reconstructed displacement eld. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared di erences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on the/nincompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, both/non displacement and velocity elds, on a set of synthetic 3D US images with di erent noise levels. TDFFD/nshowed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFD/nwas applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, the/nimprovement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quanti ed by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT., This research has been partially funded by the Spanish Industrial and Technological Development Center (CDTI) under the CENIT Programme (cvREMOD Project), the Spanish Ministry of Science and Innovation (MICINN) and the European Regional Development Fund (ERDF) through the research project STIMATH (TIN2009-14536-C02-01), and the European Community’s Seventh Framework Program (FP7/2007-2013) under the euHeart project (FP7-ICT-2007-2-224495).