Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Arias Montano. Repositorio Institucional de la Universidad de Huelva
Publication Artículo científico (JournalArticle)

Urban aerosol size distributions over the Mediterranean city of Barcelona, NE Spain

  • Dall'Osto, M.
  • Beddows, D. C. S.
  • Pey, J.
  • Rodríguez González, Sergio
  • Alastuey Urós, José Andrés
  • Harrison, Roy M.
  • Querol, X.
Differential mobility particle sizer (DMPS) aerosol concentrations (N13−800) were collected over a oneyear- period (2004) at an urban background site in Barcelona, North-Eastern Spain. Quantitative contributions to particle number concentrations of the nucleation (33–39 %), Aitken (39–49 %) and accumulation mode (18–22 %) were estimated. We examined the source and time variability of atmospheric aerosol particles by using both K-means clustering and Positive Matrix Factorization (PMF) analysis. Performing clustering analysis on hourly size distributions, nine K-means DMPS clusters were identified and, by directional association, diurnal variation and relationship to meteorological and pollution variables, four typical aerosol size distribution scenarios were identified: traffic (69% of the time), dilution (15% of the time), summer background conditions (4% of the time) and regional pollution (12% of the time). According to the results of PMF, vehicle exhausts are estimated to contribute at least to 62–66% of the total particle number concentration, with a slightly higher proportion distributed towards the nucleation mode (34 %) relative to the Aitken mode (28–32 %). Photochemically induced nucleation particles make only a small contribution to the total particle number concentration (2–3% of the total), although only particles larger than 13 nm were considered in this study. Overall the combination of the two statistical methods is successful at separating components and quantifying relative contributions to the particle number population.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Continuous atmospheric boundary layer observations in the coastal urban area of Barcelona during SAPUSS

  • Pandolfi, Marco
  • Martucci, G.
  • Querol, Xavier
  • Alastuey, Andrés
  • Wilsenack, F.
  • Frey, S.
  • O’Dowd, C. D.
  • Dall'Osto, Manuel
Continuous measurements of surface mixed layer (SML), decoupled residual/convective layer (DRCL) and aerosol backscatter coefficient were performed within the Barcelona (Spain) boundary layer from September to October 2010 (30 days) in the framework of the SAPUSS (Solving Aerosol Problems by Using Synergistic Strategies) field campaign. Two near-infrared ceilometers (Jenoptik CHM15K), vertically and horizontally probing (only vertical profiles are herein discussed), were deployed. Ceilometer-based DRCLs (1761 ± 363 m a.g.l.) averaged over the campaign duration were twice as high as the mean SML (904 ± 273 m a.g.l.). Both DRCL and SML showed a marked SML diurnal cycle. Ceilometer data were compared with potential temperature profiles measured by daily radiosounding (twice a day, midnight and midday) to interpret the boundary layer structure in the coastal urban area of Barcelona. The overall agreement (R2 = 0.80) between the ceilometer-retrieved and radiosounding-based SML heights (h) revealed overestimation of the SML by the ceilometer (Δh=145 ± 145 m). After separating the data in accordance with different atmospheric scenarios, the lowest SML (736 ± 183 m) and DRCL (1573 ± 428 m) were recorded during warm North African (NAF) advected air mass. By contrast, higher SML and DRCL were observed during stagnant Regional (REG) (911 ± 234 m and 1769 ± 314 m, respectively) and cold Atlantic (ATL) (965 ± 222 m and 1878 ± 290 m, respectively) air masses. In addition to being the lowest, the SML during the NAF scenario frequently showed a flat upper boundary throughout the day possibly because of the strong winds from the Mediterranean Sea limiting the midday SML convective growth. The mean backscatter coefficients were calculated at two selected heights representative of middle and top SML portions, i.e. β500 = 0.59 ± 0.45 Mm−1 sr−1 and β800 = 0.87 ± 0.68 Mm−1 sr−1 at 500 m and 800 m a.g.l., respectively. The highest backscatter coefficients were observed during NAF (β500 = 0.77 ± 0.57 Mm−1 sr−1) when compared with ATL (β500 = 0.51 ± 0.44 Mm−1 sr−1) and REG (β500 = 0.64 ± 0.39 Mm−1 sr−1). The relationship between the vertical change in backscatter coefficient and atmospheric stability (∂θ/∂z) was investigated in the first 3000 m a.g.l., aiming to study how the unstable, stable or neutral atmospheric conditions of the atmosphere alter the distribution of aerosol backscatter with height over Barcelona. A positive correlation between unstable conditions and enhanced backscatter and viceversa was found., This study was supported by FP7-PEOPLE- 2009-IEF, Project number 254773, SAPUSS – Solving Aerosol Problems Using Synergistic Strategies (Marie Curie Actions – Intra European Fellowships. Manuel Dall’Osto), the Spanish Ministry of Science and Innovation and FEDER funds under the project PRISMA (CGL2012-39623-C02/00), GRACCIE (CSD2007-00067), VAMOS (CLG2010-19464), and the Generalitat de Catalunya (2009 SGR8). M. Pandolfi was funded by the JAE-Doc CSIC program, co-funded by the European Social Fund (ESF). The authors gratefully acknowledge the NOAA Air Resources Laboratory (ARL) for the provision of the HYSPLIT transport and dis- persion model and/or READY website (http://www.arl.noaa.gov/ready.html) used in this publication. Thanks are also due to Jose Ma. Baldasano and staff for their help in establishing and maintaining the Barcelona AERONET measurement site. The authors wish to thank the Catalan Meteorological Service for providing the BCN radiosounding data. The authors wish to thank D. C. Carslaw and K. Ropkins for providing the Openair software used in this paper (Carslaw and Ropkins, 2012; Carslaw, 2012)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Source apportionment of urban PM1 in Barcelona during SAPUSS using organic and inorganic components

  • Brines, M.
  • Dall'Osto, Manuel
  • Amato, Fulvio
  • Minguillón, María Cruz
  • Karanasiou, Angeliki
  • Grimalt, Joan O.
  • Alastuey, Andrés
  • Querol, Xavier
  • Drooge, Barend L. van
14 pages, 3 figures, 2 tables, supplementary material https://doi.org/10.1007/s11356-019-06199-3, Source apportionment of atmospheric PM1 is important for air quality control, especially in urban areas where high mass concentrations are often observed. Chemical analysis of molecular inorganic and organic tracer compounds and subsequently data analysis with receptor models give insight on the origin of the PM1 sources. In the present study, four source apportionment approaches were compared with an extended database containing inorganic and organic compounds that were measured during an intensive sampling campaign at urban traffic and urban background sites in Barcelona. Source apportionment of the combined database, containing both inorganic and organic compounds, was compared with more conventional approaches using inorganic and organic databases separately. Traffic emission sources were identified in all models for the two sites. The combined inorganic and organic databases provided higher discrimination capacity of emission sources. It identified aerosols generated by regional recirculation of biomass burning, secondary biogenic organic aerosols, harbor emissions, and specific industrial emissions. In this respect, this approach identified a relevant industrial source situated at NE Barcelona in which a waste incinerator plant, a combined-cycle power plant, and an industrial glass complex are located. Models using both inorganic and organic molecular tracer compounds improve the source apportionment of urban PM, Financial support for this study was provided by the Marie Curie FP7 SAPUSS (FP7-PEOPLE-2009-IEF, project number 254773), research projects from the D.G. de Calidad y Evaluacion Ambiental (Spanish Ministry of the Environment), and the Plan Nacional de IyD (Spanish Ministry of Science and Innovation) CGL2010-19464-VAMOS and CGL2011-29621, and the Generalitat de Catalunya (AGAUR 2017 SGR41), Peer Reviewed
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

New considerations for PM, black carbon and particle number concentration for air quality monitoring across different European cities

  • Reche Andúgar, Cristina|||0000-0002-3387-3989
  • Querol Carceller, Xavier|||0000-0002-6549-9899
  • Alastuey, Andrés|||0000-0002-5453-5495
  • Viana Rodríguez, María del Mar
  • Pey, J.
  • Moreno Pérez, Teresa
  • Rodríguez, S.
  • González, Yenny
  • Fernández Camacho, R.
  • Sánchez de la Campa, A. M.
  • De la Rosa, J.
  • Dall'Osto, M.
  • Prévôt, A. S. H.
  • Hueglin, C.
  • Harrison, R. M.
  • Quincey, P.
In many large cities of Europe standard air quality limit values of particulate matter (PM) are exceeded. Emissions from road traffic and biomass burning are frequently reported to be the major causes. As a consequence of these exceedances a large number of air quality plans, most of them focusing on traffic emissions reductions, have been implemented in the last decade. In spite of this implementation, a number of cities did not record a decrease of PM levels. Thus, is the efficiency of air quality plans overestimated? Do the road traffic emissions contribute less than expected to ambient air PM levels in urban areas? Or do we need a more specific metric to evaluate the impact of the above emissions on the levels of urban aerosols? This study shows the results of the interpretation of the variability of levels of PM, Black Carbon (BC), aerosol number concentration (N) and a number of gaseous pollutants in seven selected urban areas covering road traffic, urban background, urban-industrial, and urban-shipping environments from southern, central and northern Europe. The results showed that variations of PM and N levels do not always reflect the variation of the impact of road traffic emissions on urban aerosols. However, BC levels vary proportionally with those of traffic related gaseous pollutants, such as CO, NO₂ and NO. Due to this high correlation, one may suppose that monitoring the levels of these gaseous pollutants would be enough to extrapolate exposure to traffic-derived BC levels. However, the BC/CO, BC/NO₂ and BC/NO ratios vary widely among the cities studied, as a function of distance to traffic emissions, vehicle fleet composition and the influence of other emission sources such as biomass burning. Thus, levels of BC should be measured at air quality monitoring sites. During morning traffic rush hours, a narrow variation in the N/BC ratio was evidenced, but a wide variation of this ratio was determined for the noon period. Although in central and northern Europe N and BC levels tend to vary simultaneously, not only during the traffic rush hours but also during the whole day, in urban background stations in southern Europe maximum N levels coinciding with minimum BC levels are recorded at midday in all seasons. These N maxima recorded in southern European urban background environments are attributed to midday nucleation episodes occurring when gaseous pollutants are diluted and maximum insolation and O₃ levels occur. The occurrence of SO₂ peaks may also contribute to the occurrence of midday nucleation bursts in specific industrial or shipping-influenced areas, although at several central European sites similar levels of SO₂ are recorded without yielding nucleation episodes. Accordingly, it is clearly evidenced that N variability in different European urban environments is not equally influenced by the same emission sources and atmospheric processes. We conclude that N variability does not always reflect the impact of road traffic on air quality, whereas BC is a more consistent tracer of such an influence. However, N should be measured since ultrafine particles (<100 nm) may have large impacts on human health. The combination of PM₁₀ and BC monitoring in urban areas potentially constitutes a useful approach for air quality monitoring. BC is mostly governed by vehicle exhaust emissions, while PM₁₀ concentrations at these sites are also governed by non-exhaust particulate emissions resuspended by traffic, by midday atmospheric dilution and by other nontraffic emissions.