Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Torsional resonance mode magnetic force microscopy: Enabling higher lateral resolution magnetic imaging without topography-related effects

  • Kaidatzis, Andreas
  • García-Martín, José Miguel
We present experimental work that reveals the benefits of performing magnetic force microscopy measurements employing the torsional resonance mode of cantilever oscillation. This approach provides two clear advantages: the ability of performing magnetic imaging without topography-related interference and the significant lateral resolution improvement (approximately 15%). We believe that this work demonstrates a significant improvement to a versatile magnetic imaging technique widely used in academia and in industry. © 2013 IOP Publishing Ltd., AK received funding from the EC through a FP7 Intra-European Marie Curie post-doctoral Fellowship (Grant No. PIEF-GA-2010-272470). Funding from the Spanish MINECO (refs. MAT2011-29194-C02-01, MAT2010-10213-E and CSD2008-00023) and Comunidad de Madrid (S2009/MAT-1726) is also acknowledged., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Magnetic structure of nanometer scale magnetic antidot arrays

  • Kaidatzis, Andreas
  • Pérez del Real, Rafael
  • Béron, Fanny
  • Palma, Juan Luis
  • Álvaro Bruna, Raquel
  • Palmero, Ester M.
  • Velo, Murilo F.
  • Arzuza, Luis C. C.
  • Niarchos, Dimitrios
  • Vázquez Villalabeitia, Manuel
  • Pirota, K. R.
  • Escrig, Juan
  • García-Martín, José Miguel
Trabajo presentado en la conferencia Fuerzas y Túnel (FyT2016), celebrada en Girona del 5 al 7 de septiembre de 2016., Magnetic antidot arrays are groups of ordered holes patterned on a continuous magnetic film. They can be used as magnonic crystals with potential application in microwave devices [1], for magnetically-active plasmonics [2], and for biosensing applications [3]. We have followed two different routes to obtain magnetic antidots on Co, Permalloy (Py), and Co/Py films with different characteristics. Focused ion beam allowed obtaining hexagonal or square lattice antidot arrays with long-range order (hole diameter d=55nm, periodicity p=150-300nm) [4], whereas oblique deposition onto nanoporous alumina templates was used to obtain arrays with only hexagonal short-range order (d=40nm, p=105nm) [5]. The arrays were studied by magneto-optic Kerr effect, magnetic force microscopy (MFM) and micromagnetic simulations. It is shown how the coercivity increases with the density of antidots and the magnetic anisotropy axes strongly depend on the array symmetry. The MFM images show the magnetic structure of the arrays to be commensurate to their morphology, with domain walls (DW) pinned by the holes and in some cases super-DW separating linear domains (see Fig.)., Funding from CSIC (i-Link0783), MINECO (MAT2014-59772-C2-1), Comunidad de Madrid (Nanofrontmag), FAPESP (Brazil), Basal and Fondecyt (Chile) and EU (318144 and 272470)., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Magnetic properties engineering of nanopatterned cobalt antidot arrays

  • Kaidatzis, Andreas
  • Pérez del Real, Rafael
  • Álvaro Bruna, Raquel
  • Palma, Juan Luis
  • Anguita, José Virgilio
  • Niarchos, Dimitrios
  • Vázquez Villalabeitia, Manuel
  • Escrig, Juan
  • García-Martín, José Miguel
We report on the study of arrays of 60 nm wide cobalt antidots, nanopatterned using focused ion beam milling. Square and hexagonal symmetry arrays have been studied, with varying antidot densities and lattice constant from 150 up to 300 nm. We find a strong increase of the arrays' magnetic coercivity with respect to the unpatterned film, which is monotonic as the antidot density increases. Additionally, there is a strong influence of the array symmetry to the in-plane magnetic anisotropy: square arrays exhibit fourfold symmetry and hexagonal arrays exhibit sixfold symmetry. The above findings are corroborated by magnetic imaging and micromagnetic modeling, which show the magnetic structure of the arrays to depend strongly on the array morphology., AK received funding from the EC through a FP7 individual Marie Curie fellowship (Grant No. 272470). We also acknowledge funding from the EC through a FP7-ICT project (Grant No. 318144), from CSIC (ref. i-LINK0783), from Comunidad de Madrid (ref: Nanofrontmag), from DICYT, from Fondequip (ref. EQM140092), from Fondecyt (refs. 3130393 and 1150952), and from the Basal Project (ref. FB0807)., Peer reviewed