Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 24
Encontrada(s) 1 página(s)

Repositorio Institucional del Instituto Madrileño de Estudios Avanzados en Nanociencia
Publication Artículo científico (JournalArticle)

Nanomechanical properties of composite protein networks of erythroid membranes at lipid surfaces

  • Encinar M.
  • Casado S.
  • Calzado-Martín A.
  • Natale P.
  • San Paulo Á.
  • Calleja M.
  • Vélez M.
  • Monroy F.
  • López-Montero I.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Biosensors based on nanomechanical systems

  • Tamayo de Miguel, Francisco Javier
  • Kosaka, Priscila M.
  • Ruz Martínez, José Jaime
  • San Paulo, Álvaro
  • Calleja, Montserrat
The advances in micro- and nanofabrication technologies enable the preparation of increasingly smaller mechanical transducers capable of detecting the forces, motion, mechanical properties and masses that emerge in biomolecular interactions and fundamental biological processes. Thus, biosensors based on nanomechanical systems have gained considerable relevance in the last decade. This review provides insight into the mechanical phenomena that occur in suspended mechanical structures when either biological adsorption or interactions take place on their surface. This review guides the reader through the parameters that change as a consequence of biomolecular adsorption: mass, surface stress, effective Young's modulus and viscoelasticity. The mathematical background needed to correctly interpret the output signals from nanomechanical biosensors is also outlined here. Other practical issues reviewed are the immobilization of biomolecular receptors on the surface of nanomechanical systems and methods to attain that in large arrays of sensors. We then describe some relevant realizations of biosensor devices based on nanomechanical systems that harness some of the mechanical effects cited above. We finally discuss the intrinsic detection limits of the devices and the limitation that arises from non-specific adsorption., The authors would like to acknowledge financial support from the Spanish Science Ministry through projects ANEM! (TEC2009-14517-C02), INMUNO-swing (IPT-2011-0821-010000), POLYSENS (PIB2010BZ-0510) and ForceForFuture (CSD2010-00024); and from European Research Council through Starting Grant NANO- FORCELLS (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Optical back-action in silicon nanowire resonators: bolometric versus radiation pressure effects

  • Gil-Santos, Eduardo
  • Ramos Vega, Daniel
  • Pini, Valerio
  • Llorens Montolio, José Manuel
  • Fernández-Regúlez, Marta
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
  • San Paulo, Álvaro
We study optical back-action effects associated with confined electromagnetic modes in silicon nanowire resonators interacting with a laser beam used for interferometric read-out of the nanowire vibrations. Our analysis describes the resonance frequency shift produced in the nanowires by two different mechanisms: the temperature dependence of the nanowire's Young's modulus and the effect of radiation pressure. We find different regimes in which each effect dominates depending on the nanowire morphology and dimensions, resulting in either positive or negative frequency shifts. Our results also show that in some cases bolometric and radiation pressure effects can have opposite contributions so that their overall effect is greatly reduced. We conclude that Si nanowire resonators can be engineered for harnessing back-action effects for either optimizing frequency stability or exploiting dynamic phenomena such as parametric amplification., The authors acknowledge financial support from the Spanish Science Ministry through projects TEC2009-14517-C02-01/02, TEC2008-06756-C03-01 and CSD2010-00024 and from the EU through the project ERC-Starting Grants-StG-2011-278860-NANOFORCELLS. DR acknowledges financial support from the EU grant IOF-2009-254996., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tackling reproducibility in microcantilever biosensors: a statistical approach for sensitive and specific end-point detection of immunoreactions

  • Kosaka, Priscila M.
  • Tamayo de Miguel, Francisco Javier
  • Ruz Martínez, José Jaime
  • Puertas, Sara
  • Polo, Ester
  • Grazú, Valeria
  • Fuente, Jesús M. de la
  • Calleja, Montserrat
Título en el postprint: Sensitive and Specific End-point detection of Immunoreactions by Nanomechanical Biosensors: Statistical approach to response variability, In the last decade, microcantilever biosensors have shown enormous potential for highly sensitive label-free detection of nucleic acid and proteins. Despite the enormous advances, the promise of applications of this technology in the biomedical field has been frustrated because of its low reproducibility. Here we tackle the reproducibility issue in microcantilever biosensors and provide the guidelines to minimize the deviations in the biosensor response between different assays. We use as a model system the label-free end-point detection of horseradish peroxidase. We choose the end-point detection mode because of its suitability for implementation in the clinical field that requires simplicity and point-of-care capability. Our study comprises the analysis of 1012 cantilevers with different antibody surface densities, two blocking strategies based on polyethylene-glycol (PEG) and bovine serum albumin (BSA) and stringent controls. The study reveals that the performance of the assay critically depends on both antibody surface density and blocking strategies. We find that the optimal conditions involve antibody surface densities near but below saturation and blocking with PEG. We find that the surface stress induced by the antibody–antigen binding is significantly correlated with the surface stress generated during the antibody attachment and blocking steps. The statistical correlation is harnessed to identify immobilization failure or success, and thus enhancing the specificity and sensitivity of the assay. This procedure enables achieving rates of true positives and true negatives of 90% and 91% respectively. The detection limit is of 10 ng mL−1 (250 pM) that is similar to the detection limit obtained in our enzyme-linked immunosorbent assay (ELISA) and at least two orders of magnitude smaller than that achieved with well-established label-free biosensors such as a quartz crystal microbalance (QCM) and surface plasmon resonance (SPR) sensor., The authors acknowledge financial support from the Spanish Science Ministry through projects ANEM! (TEC2009-14517-C02) and INMUNO-swing (IPT-2011-0821-010000) and from European Research Council through Starting Grants NANOFORCELLS (ERC-StG-2011-278860) and NANOPUZZLE (ERC-StG-2009-239931)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Atomic force microscopy reveals two phases in single stranded DNA self-assembled monolayers

  • Kosaka, Priscila M.
  • González-Castilla, Sheila
  • Domínguez, Carmen M.
  • Cebollada, Alfonso
  • San Paulo, Álvaro
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
We have investigated the structure of single-stranded (ss) DNA self-assembled monolayers (SAMs) on gold by combining peak force tapping, Kelvin probe and phase contrast atomic force microscopy (AFM) techniques. The adhesion, surface potential and phase shift signals show heterogeneities in the DNA film structure at two levels: microscale and nanoscale; which cannot be clearly discerned in the topography. Firstly, there is multilayer aggregation covering less than 5% of the surface. The DNA multilayers seem to be ordered phases and their existence suggests that DNA end-to-end interaction can play a role in the self-assembly process. Secondly, we find the formation of two phases in the DNA monolayer, which differ both in surface energy and surface potential. We relate the two domains to differences in the packing density and in the ssDNA conformation. The discovered heterogeneities in ssDNA SAMs provide a new scenario in our vision of these relevant films that have direct consequences on their biological, chemical and physical properties., We acknowledge financial support from the Spanish Science Ministry through projects INMUNO-swing (IPT-2011-0821-010000) and ForceForFuture (CSD2010-00024); from Comunidad de Madrid through S2009/MAT1507 and from the European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Fabrication and Mechanical Characterization of Semi-Free-Standing (Conjugated) Polymer Thin Films

  • Martín Pérez, Jaime
  • Muñoz Rojo, Miguel
  • Encinar, Mario
  • Calleja, Montserrat
  • Martín-González, Marisol
Polymers undergo severe low-dimensionality effects when they are confined to ultrathin films since most of the structural and dynamical processes involving polymer molecules are correlated to length scales of the order of nanometers. However, the real influence of the size limitation over such processes is often hard to identify as it is masked by interfacial effects. We present the fabrication of a new type of nanostructure consisting of poly[[9-(1-octylnonyl)-9H-carbazole-2,7-diyl]-2,5-thiophenediyl-2,1,3-benzothiadiazole-4,7-diyl-2,5-thiophenediyl] (PCDTBT) thin film that is held up exclusively over tips of poly(ether–ether–ketone) (PEEK) nanopillars. The fabrication method exploits the nonwetting behavior of PCDTBT onto an ordered PEEK nanopillar array when the mobility of the PCDTBT molecules is enhanced by a solvent annealing process. We use this new configuration to characterize the mechanical behavior of free-standing thin film regions, thus in the absence of underlaying substrate, by means of an atomic force microscope (AFM) setup. First, we study how the finite thickness and/or the presence of the underlying substrate influences the mechanical modulus of the material in the linear elastic regime. Moreover, we analyze deep indentations up to the rupture of the thin film, which allow for the measurement of important mechanical features of the nanoconfined polymer, such as its yield strain, the rupture strain, the bending rigidity, etc., which are impossible to investigate in thin films deposited on substrates., This work was supported by the ERC Starting Grants “NanoTEC” (ERC-StG-2008-240497) and “NANOFORCELLS” (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Challenges for nanomechanical sensors in biological detection

  • Calleja, Montserrat
  • Kosaka, Priscila M.
  • San Paulo, Álvaro
  • Tamayo de Miguel, Francisco Javier
Nanomechanical biosensing relies on changes in the movement and deformation of micro- and nanoscale objects when they interact with biomolecules and other biological targets. This field of research has provided ever-increasing records in the sensitivity of label-free detection but it has not yet been established as a practical alternative for biological detection. We analyze here the latest advancements in the field, along with the challenges remaining for nanomechanical biosensors to become a commonly used tool in biology and biochemistry laboratories., We acknowledge financial support from the Spanish Science Ministry through projects ANEM! (TEC2009-14517-C02), INMUNO-swing (IPT-2011-0821-010000) and ForceForFuture (CSD2010-00024); and from European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Imaging the surface stress and vibration modes of a microcantilever by laser beam deflection microscopy

  • Tamayo de Miguel, Francisco Javier
  • Pini, Valerio
  • Kosaka, Priscila M.
  • Martínez Cuadrado, Nicolás Francisco
  • Ahumada, O.
  • Calleja, Montserrat
There is a need for noninvasive techniques for simultaneous imaging of the stress and vibration mode shapes of nanomechanical systems in the fields of scanning probe microscopy, nanomechanical biological and chemical sensors and the semiconductor industry. Here we show a novel technique that combines a scanning laser, the beam deflection method and digital multifrequency excitation and analysis for simultaneous imaging of the static out-of-plane displacement and the shape of five vibration modes of nanomechanical systems. The out-of-plane resolution is at least 100 pm Hz−1/2 and the lateral resolution, which is determined by the laser spot size, is 1–1.5 μm. The capability of the technique is demonstrated by imaging the residual surface stress of a microcantilever together with the shape of the first 22 vibration modes. The vibration behavior is compared with rigorous finite element simulations. The technique is suitable for major improvements in the imaging of liquids, such as higher bandwidth and enhanced spatial resolution., The authors acknowledge financial support from the Spanish Science Ministry through the projects ANEM! (TEC2009-14517-C02) and INMUNO-swing (IPT-2011-0821-010000), and from the European Union through the project NANOFORCELLS (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Quantification of the surface stress in microcantilever biosensors: revisiting Stoney's equation

  • Tamayo de Miguel, Francisco Javier
  • Ruz Martínez, José Jaime
  • Pini, Valerio
  • Kosaka, Priscila M.
  • Calleja, Montserrat
Microcantilever biosensors in the static operation mode translate molecular recognition into a surface stress signal. Surface stress is derived from the nanomechanical cantilever bending by applying Stoney's equation, derived more than 100 years ago. This equation ignores the clamping effect on the cantilever deformation, which induces significant errors in the quantification of the biosensing response. This leads to discrepancies in the surface stress induced by biomolecular interactions in measurements with cantilevers with different sizes and geometries. So far, more accurate solutions have been precluded by the formidable complexity of the theoretical problem that involves solving the two-dimensional biharmonic equation. In this paper, we present an accurate and simple analytical expression to quantify the response of microcantilever biosensors. The equation exhibits an excellent agreement with finite element simulations and DNA immobilization experiments on gold-coated microcantilevers., The authors acknowledge financial support from the Spanish Science Ministry through projects ANEM! (TEC2009-14517-C02) and INMUNO-swing (IPT-2011-0821-010000); and from European Research Council through starting grant NANOFORCELLS (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Silicon nanowires: where mechanics and optics meet at the nanoscale

  • Ramos Vega, Daniel
  • Gil-Santos, Eduardo
  • Malvar, Óscar
  • Llorens Montolio, José Manuel
  • Pini, Valerio
  • San Paulo, Álvaro
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
Mechanical transducers based on nanowires promise revolutionary advances in biological sensing and force microscopy/spectroscopy. A crucial step is the development of simple and non-invasive techniques able to detect displacements with subpicometer sensitivity per unit bandwidth. Here, we design suspended tapered silicon nanowires supporting a range of optical resonances that confine and efficiently scatter light in the visible range. Then, we develop an optical method for efficiently coupling the evanescent field to the regular interference pattern generated by an incoming laser beam and the reflected beam from the substrate underneath the nanowire. This optomechanical coupling is here applied to measure the displacement of 50 nm wide nanowires with sensitivity on the verge of 1 fm/Hz1/2 at room temperature with a simple laser interferometry set-up. This method opens the door to the measurement of the Brownian motion of ultrashort nanowires for the detection of single biomolecular recognition events in liquids, and single molecule spectroscopy in vacuum., We acknowledge financial support from the Spanish Science Ministry (MINECO) through projects TEC2011-29120-C05-04; and from European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Hydration Induced Stress on DNA Monolayers Grafted on Microcantilevers

  • Domínguez, Carmen M.
  • Kosaka, Priscila M.
  • Mokry, Guillermo
  • Pini, Valerio
  • Malvar, Óscar
  • Rey Franco, Mercedes del
  • Ramos Vega, Daniel
  • San Paulo, Álvaro
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
Surface tethered single-stranded DNA films are relevant biorecognition layers for oligonucleotide sequence identification. Also, hydration induced effects on these films have proven useful for the nanomechanical detection of DNA hybridization. Here, we apply nanomechanical sensors and atomic force microscopy to characterize in air and upon varying relative humidity conditions the swelling and deswelling of grafted single stranded and double stranded DNA films. The combination of these techniques validates a two-step hybridization process, where complementary strands first bind to the surface tethered single stranded DNA probes and then slowly proceed to a fully zipped configuration. Our results also demonstrate that, despite the slow hybridization kinetics observed for grafted DNA onto microcantilever surfaces, ex situ sequence identification does not require hybridization times typically longer than 1 h, while quantification is a major challenge., This work was supported by the ERC Starting Grant “NANOFORCELLS” (ERC-StG-2011-278860) and Projects INMUNO-SWING ITP-2011-0821-010000, FORCEFORFUTURE CSD2010-00024, and MAT2012-36197., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Monitoring swelling and deswelling of thin polymer films by microcantilever sensors

  • Rey Franco, Mercedes del
  • Silva, Rubens A. da
  • Meneses-Rodríguez, David
  • Petri, Denise F. S.
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
  • Kosaka, Priscila M.
Microcantilever based sensors are promising devices because they are fast, low cost, portable and allow measuring extremely small quantities of substances in gas or liquid phase that are not detectable by other methods. In this work we investigate the swelling and deswelling behavior of poly(hydroxyl ethyl methacrylate), PHEMA, films with three different average molecular masses deposited onto bare silicon microcantilevers, a hydrophilic substrate, and onto polystyrene (PS) coated microcantilevers, which is a hydrophobic substrate, under humidity cycles by monitoring the deflections resulting from differential surface stress. The results found in the present study demonstrate that the micromechanical response observed are related not only to the polymer molecular weight, but also to the polymer-interface phenomena and environment-polymer interface that can play a crucial role on the signal transduction. Ellipsometric measurements evidenced that the swelling of PHEMA films with intermediate molecular weight at 80% RH follows Fickian diffusion mechanism. Nevertheless, due to the weak optical contrast or film homogeneity shorter or longer chains than PHEMA-300 could not be investigated by ellipsometry. PHEMA films deposited onto PS surfaces presented dewetting, which limited the ellipsometric measurements. In comparison to ellipsometry, monitoring swelling behavior of PHEMA by nanomechanical responses is more advantageous because it is faster and less restricted. © 2014 Elsevier B.V. All rights reserved., The authors acknowledge the financial support from the Brazilian Agency CNPq through the grants #560565/2010-0 and #209693/2012-6 and the financial support from the Spanish Science Ministry through projects #PIB2010BZ-00510); and from European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Ultrasensitive thermometer for atmospheric pressure operation based on a micromechanical resonator

  • Cagliani, Alberto
  • Pini, Valerio
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
  • Davis, Zachary James
For highly integrated systems for bio and chemical analysis a precise and integrated measurement of temperature is of fundamental importance. We have developed an ultrasensitive thermometer based on a micromechanical resonator for operation in air. The high quality factor and the strong temperature dependence of the resonance frequency of these bulk microresonators enable accurate temperature measurements. Here, we delineate the conditions to decouple the temperature effect on the resonance frequency, from the water adsorption/desorption on the resonator surface that happens when it is operated in air. This study enables high temperature resolution measurements, as well as the possibility of monitoring adsorption and desorption processes on the resonator surface with a resolution of 0.007 water molecules per nm2. These devices reach a temperature resolution of 3 mK in air, which is one of the best ever reported temperature resolution for resonator based thermometers. © 2014 Elsevier B.V., We acknowledge financial support from the Spanish Science Ministry (MINECO) through projects MAT2012-36197; and from European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Detection of cancer biomarkers in serum using a hybrid mechanical and optoplasmonic nanosensor

  • Kosaka, Priscila M.
  • Pini, Valerio
  • Ruz Martínez, José Jaime
  • Silva, Rubens A. da
  • González Sagardoy, María Ujué
  • Ramos Vega, Daniel
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
Blood contains a range of protein biomarkers that could be used in the early detection of disease. To achieve this, however, requires sensors capable of detecting (with high reproducibility) biomarkers at concentrations one million times lower than the concentration of the other blood proteins. Here, we show that a sandwich assay that combines mechanical and optoplasmonic transduction can detect cancer biomarkers in serum at ultralow concentrations. A biomarker is first recognized by a surface-anchored antibody and then by an antibody in solution that identifies a free region of the captured biomarker. This second antibody is tethered to a gold nanoparticle that acts as a mass and plasmonic label; the two signatures are detected by means of a silicon cantilever that serves as a mechanical resonator for ‘weighing’ the mass of the captured nanoparticles and as an optical cavity that boosts the plasmonic signal from the nanoparticles. The capabilities of the approach are illustrated with two cancer biomarkers: the carcinoembryonic antigen and the prostate specific antigen, which are currently in clinical use for the diagnosis, monitoring and prognosis of colon and prostate cancer, respectively. A detection limit of 1 × 10−16 g ml−1 in serum is achieved with both biomarkers, which is at least seven orders of magnitude lower than that achieved in routine clinical practice. Moreover, the rate of false positives and false negatives at this concentration is extremely low, ∼10−4., We acknowledge financial support from the Spanish Science Ministry (MINECO) through projects MAT2012-36197 and INMUNO-SWING ITP-2011-0821-010000; and from European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Highly sensitive measurement of liquid density in air using suspended microcapillary resonators

  • Malvar, Óscar
  • Ramos Vega, Daniel
  • Domínguez, Carmen M.
  • Kosaka, Priscila M.
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
© 2015 by the authors; licensee MDPI, Basel, Switzerland. We report the use of commercially available glass microcapillaries as micromechanical resonators for real-time monitoring of the mass density of a liquid that flows through the capillary. The vibration of a suspended region of the microcapillary is optically detected by measuring the forward scattering of a laser beam. The resonance frequency of the liquid filled microcapillary is measured for liquid binary mixtures of ethanol in water, glycerol in water and Triton in ethanol. The method achieves a detection limit in an air environment of 50 μg/mL that is only five times higher than that obtained with state-of-the-art suspended microchannel resonators encapsulated in vacuum. The method opens the door to novel advances for miniaturized total analysis systems based on microcapillaries with the add-on of mechanical transduction for sensing the rheological properties of the analyzed fluids without the need for vacuum encapsulation of the resonators., We acknowledge financial support from the Spanish Science Ministry (MINECO) through projects MAT2012-36197 and INMUNO-SWING ITP-2011-0821-010000, and from the European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., We acknowledge support of the publication fee by the CSIC Open Access Publication Support Initiative through its Unit of Information Resources for Research (URICI)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Physics of nanomechanical spectrometry of viruses

  • Ruz Martínez, José Jaime
  • Tamayo de Miguel, Francisco Javier
  • Pini, Valerio
  • Kosaka, Priscila M.
  • Calleja, Montserrat
There is an emerging need of nanotools able to quantify the mechanical properties of single biological entities. A promising approach is the measurement of the shifts of the resonant frequencies of ultrathin cantilevers induced by the adsorption of the studied biological systems. Here, we present a detailed theoretical analysis to calculate the resonance frequency shift induced by the mechanical stiffness of viral nanotubes. The model accounts for the high surface-to-volume ratio featured by single biological entities, the shape anisotropy and the interfacial adhesion. The model is applied to the case in which tobacco mosaic virus is randomly delivered to a silicon nitride cantilever. The theoretical framework opens the door to a novel paradigm for biological spectrometry as well as for measuring the Young's modulus of biological systems with minimal strains., We acknowledge financial support from the Spanish Science Ministry (MINECO) through projects MAT2012-36197 and from European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tapered silicon nanowires for enhanced nanomechanical sensing

  • Malvar, Óscar
  • Gil-Santos, Eduardo
  • Ruz Martínez, José Jaime
  • Ramos Vega, Daniel
  • Pini, Valerio
  • Fernández-Regúlez, Marta
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
  • San Paulo, Álvaro
We investigate the effect of controllably induced tapering on the resonant vibrations and sensing performance of silicon nanowires. Simple analytical expressions for the resonance frequencies of the first two flexural modes as a function of the tapering degree are presented. Experimental measurements of the resonance frequencies of singly clamped nanowires are compared with the theory. Our model is valid for any nanostructure with tapered geometry, and it predicts a reduction beyond two orders of magnitude of the mass detection limit for conical resonators as compared to uniform beams with the same length and diameter at the clamp. © 2013 AIP Publishing LLC., This work was partially funded by projects MAT2012-36197, IPT-2011-0821-010000, CSD2010-00024, IOF-2009-254996, and ERC-StG-2011-278860., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Effect of Actin Organization on the Stiffness of Living Breast Cancer Cells Revealed by Peak-Force Modulation Atomic Force Microscopy

  • Calzado-Martín, Alicia
  • Encinar, Mario
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
  • San Paulo, Álvaro
We study the correlation between cytoskeleton organization and stiffness of three epithelial breast cancer cells lines with different degrees of malignancy: MCF-10A (healthy), MCF-7 (tumorigenic/noninvasive), and MDA-MB-231 (tumorigenic/invasive). Peak-force modulation atomic force microscopy is used for high-resolution topography and stiffness imaging of actin filaments within living cells. In healthy cells, local stiffness is maximum where filamentous actin is organized as well-aligned stress fibers, resulting in apparent Young's modulus values up to 1 order of magnitude larger than those in regions where these structures are not observed, but these organized actin fibers are barely observed in tumorigenic cells. We further investigate cytoskeleton conformation in the three cell lines by immunofluorescence confocal microscopy. The combination of both techniques determines that actin stress fibers are present at apical regions of healthy cells, while in tumorigenic cells they appear only at basal regions, where they cannot contribute to stiffness as probed by atomic force microscopy. These results substantiate that actin stress fibers provide a dominant contribution to stiffness in healthy cells, while the elasticity of tumorigenic cells appears not predominantly determined by these structures. We also discuss the effects of the high-frequency indentations inherent to peak-force atomic force microscopy for the identification of mechanical cancer biomarkers. Whereas conventional low loading rate indentations (1 Hz) result in slightly differentiated average stiffness for each cell line, in high-frequency measurements (250 Hz) healthy cells are clearly discernible from both tumorigenic cells with an enhanced stiffness ratio; however, the two cancerous cell lines produced indistinguishable results., This work was supported by the ERC Starting Grant “NANOFORCELLS” (ERC-StG-2011-278860) and by the project “FORCE-FOR-FUTURE” (CSD2010-00024)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Label-free dna-based detection of mycobacterium tuberculosis and rifampicin resistance through hydration induced stress in microcantilevers

  • Domínguez, Carmen M.
  • Kosaka, Priscila M.
  • Sotillo, Alma
  • Mingorance, Jesús
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
We have developed a label-free assay for the genomic detection of Mycobacterium tuberculosis and rifampicin resistance. The method relies on the quantification of the hydration induced stress on microcantilever biosensors functionalized with oligonucleotide probes, before and after hybridization with specific targets. We have found a limit of detection of 10 fg/mL for PCR amplified products of 122 bp. Furthermore, the technique can successfully target genomic DNA (gDNA) fragments of length >500 bp, and it can successfully discriminate single mismatches. We have used both loci IS6110 and rpoB as targets to detect the mycobacteria and the rifampicin resistance from gDNA directly extracted from bacterial culture and without PCR amplification. We have been able to detect 2 pg/mL target concentration in samples with an excess of interfering DNA and in a total analysis time of 1 h and 30 min. The detection limit found demonstrates the capability to develop direct assays without the need for long culture steps or PCR amplification. The methodology can be easily translated to different microbial targets, and it is suitable for further development of miniaturized devices and multiplexed detection., This work was supported by the ERC Starting Grant “NANOFORCELLS” (ERC-StG-2011-278860) and projects INMUNO-SWING ITP-2011-0821-010000 and MAT2012-36197., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Direct detection of OXA-48 carbapenemase gene in lysate samples through changes in mechanical properties of DNA monolayers upon hybridization

  • Domínguez, Carmen M.
  • Ramos Vega, Daniel
  • Mingorance, Jesús
  • Fierro, José L.G.
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
Carbapenem-resistant Enterobacteriaceae have recently become an important cause of morbidity and mortality due to healthcare-associated infections. Most commonly used diagnostic methods are incompatible with fast and accurate directed therapy. We report here the direct identification of the blaOXA48 gene, which codes for the carbapenemase OXA-48, in lysate samples from Klebsiella pneumoniae. The method is PCR-free and label-free. It is based on the measurement of changes in the stiffness of DNA self-assembled monolayers anchored to microcantilevers that occur as a consequence of the hybridization. The stiffness of the DNA layer is measured through changes of the sensor resonance frequency upon hybridization and at varying relative humidity., This work was supported by the Spanish Science Ministry (MINECO) through project MAT2015-66904-R and by European Research Council through NANOFORCELLS project (ERC-StG-2011-278860) and European Union’s Horizon 2020 research and innovation program under grant agreement No. 731868-VIRUSCAN. D.R. acknowledges the Ramon y Cajal fellowship supported by Spanish Ministry MINECO. Authors also acknowledge the service from the XSEM Laboratory at IMN and funding from MINECO under project CSIC13-4E-1794 with support from EU (FEDER, FSE)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanomechanical properties of composite protein networks of erythroid membranes at lipid surfaces

  • Encinar, Mario
  • Casado, Santiago
  • Calzado-Martín, Alicia
  • Natale, P.
  • San Paulo, Álvaro
  • Calleja, Montserrat
  • Vélez, Marisela
  • Monroy, Francisco
  • López-Montero, Iván
Erythrocyte membranes have been particularly useful as a model for studies of membrane structure and mechanics. Native erythroid membranes can be electroformed as giant unilamellar vesicles (eGUVs). In the presence of ATP, the erythroid membrane proteins of eGUVs rearrange into protein networks at the microscale. Here, we present a detailed nanomechanical study of individual protein microfilaments forming the protein networks of eGUVs when spread on supporting surfaces. Using Peak Force tapping Atomic Force Microscopy (PF-AFM) in liquid environment we have obtained the mechanical maps of the composite lipid-protein networks supported on solid surface. In the absence of ATP, the protein pool was characterized by a Young’s Modulus Epool ≈ 5–15 MPa whereas the complex filaments were found softer after protein supramolecular rearrangement; Efil ≈ 0.4 MPa. The observed protein softening and reassembling could be relevant for understanding the mechanisms of cytoskeleton reorganization found in pathological erythrocytes or erythrocytes that are affected by biological agents., This work was supported by the ERC Starting Grant “mitochon” (ERC-StG-2013-883188) and “Programa Ramon y Cajal” (RYC-2013-12609) from the Spanish Ministry of Economy MINECO (I. L-M.), the ERC Starting Grant “NANOFORCELLS” (ERC-StG-2011-278860) (M. E., A. C-M., M. C.), the project FORCE-for-FUTURE (CSD2010-00024) (A. S. P.) and FIS2012-35723 from MINECO (F.M.)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Mass and stiffness spectrometry of nanoparticles and whole intact bacteria by multimode nanomechanical resonators

  • Malvar, Óscar
  • Ruz Martínez, José Jaime
  • Kosaka, Priscila M.
  • Domínguez, Carmen M.
  • Gil-Santos, Eduardo
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
The identification of species is a fundamental problem in analytical chemistry and biology. Mass spectrometers identify species by their molecular mass with extremely high sensitivity (<10−24 g). However, its application is usually limited to light analytes (<10−19 g). Here we demonstrate that by using nanomechanical resonators, heavier analytes can be identified by their mass and stiffness. The method is demonstrated with spherical gold nanoparticles and whole intact E. coli bacteria delivered by electrospray ionization to microcantilever resonators placed in low vacuum at 0.1 torr. We develop a theoretical procedure for obtaining the mass, position and stiffness of the analytes arriving the resonator from the adsorption-induced eigenfrequency jumps. These results demonstrate the enormous potential of this technology for identification of large biological complexes near their native conformation, a goal that is beyond the capabilities of conventional mass spectrometers., We acknowledge the service from the X-SEM Laboratory at IMM and funding from MINECO under project CSIC13-4E-1794 with support from EU (FEDER, FSE). This work was supported by the Spanish Science Ministry (MINECO) through project MAT2012-36197 and by European Research Council through NANOFORCELLS project (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

How two-dimensional bending can extraordinarily stiffen thin sheets

  • Pini, Valerio
  • Ruz Martínez, José Jaime
  • Kosaka, Priscila M.
  • Malvar, Óscar
  • Calleja, Montserrat
  • Tamayo de Miguel, Francisco Javier
Curved thin sheets are ubiquitously found in nature and manmade structures from macro- to nanoscale. Within the framework of classical thin plate theory, the stiffness of thin sheets is independent of its bending state for small deflections. This assumption, however, goes against intuition. Simple experiments with a cantilever sheet made of paper show that the cantilever stiffness largely increases with small amounts of transversal curvature. We here demonstrate by using simple geometric arguments that thin sheets subject to two-dimensional bending necessarily develop internal stresses. The coupling between the internal stresses and the bending moments can increase the stiffness of the plate by several times. We develop a theory that describes the stiffness of curved thin sheets with simple equations in terms of the longitudinal and transversal curvatures. The theory predicts experimental results with a macroscopic cantilever sheet as well as numerical simulations by the finite element method. The results shed new light on plant and insect wing biomechanics and provide an easy route to engineer micro- and nanomechanical structures based on thin materials with extraordinary stiffness tunability., This work was supported by the Spanish Science Ministry (MINECO) through project MAT2012-36197; and by European Research Council through NANOFORCELLS project (ERC-StG-2011-278860)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Spatially multiplexed dark-field microspectrophotometry for nanoplasmonics

  • Pini, Valerio
  • Kosaka, Priscila M.
  • Ruz Martínez, José Jaime
  • Malvar, Óscar
  • Encinar, Mario
  • Tamayo de Miguel, Francisco Javier
  • Calleja, Montserrat
Monitoring the effect of the substrate on the local surface plasmon resonance (LSPR) of metallic nanoparticles is key for deepening our understanding of light-matter interactions at the nanoscale. This coupling gives rise to shifts of the LSPR as well as changes in the scattering pattern shape. The problem requires of high-throughput techniques that present both high spatial and spectral resolution. We present here a technique, referred to as Spatially Multiplexed Micro-Spectrophotometry (SMMS), able to perform polarization-resolved spectral and spatial analysis of the scattered light over large surface areas. The SMMS technique provides three orders of magnitude faster spectroscopic analysis than conventional dark-field microspectrophotometry, with the capability for mapping the spatial distribution of the scattered light intensity with lateral resolution of 40 nm over surface areas of 0.02 mm2. We show polarization-resolved dark-field spectral analysis of hundreds of gold nanoparticles deposited on a silicon surface. The technique allows determining the effect of the substrate on the LSPR of single nanoparticles and dimers and their scattering patterns. This is applied for rapid discrimination and counting of monomers and dimers of nanoparticles. In addition, the diameter of individual nanoparticles can be rapidly assessed with 1 nm accuracy., We acknowledge the financial support from the Spanish Science Ministry (MINECO) through projects MAT2012-36197 and from European Research Council through Starting Grant NANOFORCELLS (ERC-StG-2011-278860)., Peer reviewed