Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Biomechanical loading as an alternative treatment for tremor: A review of two approaches

  • Rocon, Eduardo
  • Gallego, Juan Álvaro
  • Benito León, Julián
  • Pons, José Luis
  • Belda-Lois, Juan-Manuel|||0000-0002-7648-799X
[EN] Background: Tremor is the most common movement disorder and strongly increases in incidence and prevalence with aging. Although not life threatening, upper-limb tremors hamper the independence of 65% of people suffering from them affected persons, greatly impacting their quality of life. Current treatments include pharmacotherapy and surgery (thalamotomy and deep brain stimulation). However, these options are not sufficient for approximately 25% of patients. Therefore, further research and new therapeutic options are required to effectively manage pathological tremor. Methods: This paper presents findings of two research projects in which two different wearable robots for tremor management were developed based on force loading and validated. The first consisted of a robotic exoskeleton that applied forces to tremulous limbs and consistently attenuated mild and severe tremors. The second was a neuroprosthesis based on transcutaneous neurostimulation. A total of 22 patients suffering from parkinsonian or essential tremor (ET) of different severities were recruited for experimental validation, and both systems were evaluated using standard tasks employed for neurological examination. The inclusion criterion was a postural and/or kinetic pathological upper-limb tremor resistant to medication. Results: The results demonstrate that both approaches effectively suppressed tremor in most patients, although further research is required. The work presented here is based on clinical evidence from a small number of patients (n510 for robotic exoskeleton and n512 for the neuroprosthesis), but most had a positive response to the approaches. In summary, biomechanical loading is non-invasive and painless. It may be effective in patients who are insufficiently responsive (or have adverse reactions) to drugs or in whom surgery is contraindicated. Discussion: This paper identifies and evaluates biomechanical loading approaches to tremor management and discusses their potential, This research was supported by the projects DRIFTS(EU-QKL6-ICT-2002-00536), TREMOR (EU-ICT-2007-224051), NeuroTREMOR (EU-ICT-2011.5.1-287739), and the Spanish project REHABOT (DPI2008-06772-C03-01).
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Diffusion tensor imaging in orthostatic tremor: a tract‐based spatial statistics study

  • Benito-León, Julián
  • Romero, Juan Pablo
  • Louis, Elan D.
  • Sánchez‐Ferro, Alvaro
  • Matarazzo, Michele
  • Molina‐Arjona, José A.
  • Mato-Abad, Virginia
[Abstract] Objective The pathogenesis of orthostatic tremor (OT) is unknown. We investigated OT‐related white matter changes and their correlations with scores from a neuropsychological testing battery. Methods Diffusion tensor imaging measures were compared between 14 OT patients and 14 age‐ and education‐matched healthy controls, using whole‐brain tract‐based spatial statistics analysis. Correlations between altered diffusion metrics and cognitive performance in OT group were assessed. Results In all cognitive domains (attention, executive function, visuospatial ability, verbal memory, visual memory, and language), OT patients’ cognitive performance was significantly worse than that of healthy controls. OT patients demonstrated altered diffusivity metrics not only in the posterior lobe of the cerebellum (left cerebellar lobule VI) and in its efferent cerebellar fibers (left superior cerebellar peduncle), but also in medial lemniscus bilaterally (pontine tegmentum), anterior limb of the internal capsule bilaterally, right posterior limb of the internal capsule, left anterior corona radiata, right insula, and the splenium of corpus callosum. No relationship was found between diffusion measures and disease duration in OT patients. Diffusion white matter changes, mainly those located in right anterior limb of the internal capsule, were correlated with poor performance on tests of executive function, visuospatial ability, verbal memory, and visual memory in OT patients. Interpretation White matter changes were preferentially located in the cerebellum, its efferent pathways, as well as in the pontine tegmentum and key components of the frontal–thalamic–cerebellar circuit. Further work needs to be done to understand the evolution of these white matter changes and their functional consequences., National Institutes of Health; R01 NS39422, National Institutes of Health; R01 NS094607, National Institutes of Health; R01 NS085136, National Institutes of Health; R01 NS073872, National Institutes of Health; R01 NS088257, European Commission. Grant Number: ICT‐2011‐287739, Ministerio de Ecnomía y Competitividad; RTC‐2015‐3967‐1, Spanish Health Research Agency; FIS PI12/01602, Spanish Health Research Agency; FIS PI16/00451, Ministerio de Ecnomía y Competitividad; DPI‐2015‐68664‐C4‐1‐R
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

White matter microstructural changes are related to cognitive dysfunction in essential tremor

  • Benito-León, Julián
  • Mato-Abad, Virginia
  • Louis, Elan D.
  • Hernández-Tamames, Juan Antonio
  • Álvarez-Linera, Juan
  • Bermejo-Pareja, Félix
  • Domingo-Santos, Ángela
  • Collado, Luis
  • Romero, Juan Pablo
An Author Correction to this article was published on 06 March 2018: Benito-León, J., Mato-Abad, V., Louis, E.D. et al. Author Correction: White matter microstructural changes are related to cognitive dysfunction in essential tremor. Sci Rep 8, 4301 (2018). https://doi.org/10.1038/s41598-018-22516-1", [Abstract]: Diffusion tensor imaging (DTI) studies have detected white matter microstructural changes in essential tremor (ET). However, it is still unclear whether these changes are related to cognitive deficits, which have been described in ET patients. DTI-derived fractional anisotropy, mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity measures were compared between 23 ET patients and 23 age-, gender-, and education-matched healthy individuals, using whole-brain tract-based spatial statistics. Correlations of white matter changes with scores obtained from a detailed neuropsychological assessment were subsequently examined. ET patients demonstrated increases in MD in the bilateral posterior corona radiata, bilateral superior longitudinal fasciculus, bilateral fornix (cres)/stria terminalis, genu and splenium of the corpus callosum, bilateral anterior and posterior limbs of internal capsule, bilateral retrolenticular region part of internal capsule, and left posterior thalamic radiation. Except for the genu of the corpus callosum, an increase in AD values was also found in these same tracts. Furthermore, increased MD and AD values in different white matter areas was negatively correlated with performance on language and verbal memory and positively with visuospatial ability. These correlations suggest that white matter changes might be involved in the pathogenesis of cognitive deficits in ET., United States. Institutes of Health; R01 NS39422, United States. Institutes of Health; R01 NS042859, United States. Institutes of Health; R01 NS086736, United States. Institutes of Health; R01 NS073872, United States. Institutes of Health; R01 NS085136, United States. Institutes of Health; R21 NS077094, United States. Institutes of Health; R01 NS36630, This research was supported by FEDER funds. Dr. Benito-León is supported by the National Institutes of Health, Bethesda, MD, USA (NINDS #R01 NS39422), the Commission of the European Union (grant ICT-2011–287739, NeuroTREMOR), the Ministry of Economy and Competitiveness (grant RTC-2015-3967-1, NetMD—platform for the tracking of movement disorder), and the Spanish Health Research Agency (grant FIS PI12/01602 and grant FIS PI16/00451). Dr. Louis has received research support from the National Institutes of Health (NIH): NINDS #R01 NS042859 (principal investigator), NINDS #R01 NS39422 (principal investigator), NINDS #R01 NS086736 (principal investigator), NINDS #R01 NS073872 (principal investigator), NINDS #R01 NS085136 (principal investigator), NINDS #R21 NS077094 (co-Investigator), and NINDS #R01 NS36630 (co-Investigator). Dr. Romero is supported by the Commission of the European Union (grant ICT-2011-287739, NeuroTREMOR). We acknowledge the neuropsychologist Verónica Puertas, for her assistance with the project.
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Classification of Radiologically Isolated Syndrome and Clinically Isolated Syndrome with Machine-Learning Techniques

  • Mato-Abad, Virginia
  • Labiano-Fontcuberta, Andrés
  • Rodríguez-Yáñez, S.
  • García Vázquez, Rafael
  • Munteanu, Cristian-Robert
  • Andrade-Garda, Javier
  • Domingo-Santos, Ángela
  • Galán Sánchez-Seco, Victoria
  • Aladro, Yolanda
  • Martínez-Ginés, M. Luisa
  • Ayuso, Lucía
  • Benito-León, Julián
Versión final aceptada de: https://doi.org/10.1111/ene.13923, [Abstract]: Introduction: The unanticipated magnetic resonance imaging (MRI) detection in the brain of asymptomatic subjects of white matter lesions suggestive of multiple sclerosis (MS) has been named as radiologically isolated syndrome (RIS). As the difference between early MS (i.e., clinically isolated syndrome [CIS]) and RIS is the occurrence of a clinical event, it should be logical to improve detection of subclinical form without interfering with MRI as there are radiological diagnostic criteria for that. Our objective was to use machine-learning classification methods to identify morphometric measures that help to discern patients with RIS from those with CIS. Methods: We used a multimodal 3T MRI approach by combining MRI biomarkers (cortical thickness, cortical and subcortical grey matter volume, and white matter integrity) of a cohort of 17 RIS and 17 CIS patients for single-subject level classification. Results: The best proposed models to predict the CIS and RIS diagnosis were based on the Naive Bayes, Bagging and Multilayer Perceptron classifiers using only three features: the left rostral middle frontal gyrus volume, and the fractional anisotropy values in the right amygdala and in the right lingual gyrus. The Naive Bayes obtained the highest accuracy (overall classification, 0.765 and AUROC, 0.782). Conclusions: A machine-learning approach applied to multimodal MRI data may differentiate between the earliest clinical expressions of MS (CIS and RIS), with an accuracy of 78%., This research was partially supported by “Collaborative Project in Genomic Data Integration (CICLOGEN) (PI17/01826), granted by the Spanish Health Research Agency from the National Plan for Scientific and Technical Research and Innovation 2013–2016 and FEDER Funds. Dr. Benito-León is supported by the National Institutes of Health, Bethesda, MD, USA (NINDS #R01 NS39422), the Commission of the European Union (grant ICT-2011-287739, NeuroTREMOR), the Ministry of Economy and Competitiveness (grant RTC-2015-3967-1, NetMD—platform for the tracking of movement disorder), and the Spanish Health Research Agency (grant PI12/01602 and grant PI16/00451)., United States. National Institutes of Health; R01 NS39422
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A neuroprosthesis for tremor management through the control of muscle co-contraction

  • Gallego, Juan Álvaro
  • Rocón, Eduardo
  • Belda-Lois, Juan Manuel
  • Pons Rovira, José Luis
[Background] Pathological tremor is the most prevalent movement disorder. Current treatments do not attain a significant tremor reduction in a large proportion of patients, which makes tremor a major cause of loss of quality of life. For instance, according to some estimates, 65% of those suffering from upper limb tremor report serious difficulties during daily living. Therefore, novel forms for tremor management are required. Since muscles intrinsically behave as a low pass filter, and tremor frequency is above that of volitional movements, the authors envisioned the exploitation of these properties as a means of developing a novel treatment alternative. This treatment would rely on muscle co-contraction for tremor management, similarly to the strategy employed by the intact central nervous system to stabilize a limb during certain tasks., [Methods] We implemented a neuroprosthesis that regulated the level of muscle co-contraction by injecting current at a pair of antagonists through transcutaneous neurostimulation. Co-contraction was adapted to the instantaneous parameters of tremor, which were estimated from the raw recordings of a pair of solid state gyroscopes with a purposely designed adaptive algorithm. For the experimental validation, we enrolled six patients suffering from parkinsonian or essential tremor of different severity, and evaluated the effect of the neuroprosthesis during standard tasks employed for neurological examination., [Results] The neuroprosthesis attained significant attenuation of tremor (p < 0.001), and reduced its amplitude up to a 52.33±25.48%. Furthermore, it alleviated both essential and parkinsonian tremor in spite of their different etiology and symptomatology. Tremor severity was not a limiting factor on the performance of the neuroprosthesis, although there was a subtle trend towards larger attenuation of more severe tremors. Tremor frequency was not altered during neurostimulation, as expected from the central origin of Parkinson’s disease and essential tremor. All patients showed a good tolerance to neurostimulation in terms of comfort and absence of pain, and some spontaneously reported that they felt that tremor was reduced when the neuroprosthesis was activated., [Conclusions] The results presented herein demonstrate that the neuroprosthesis provides systematic attenuation of the two major types of tremor, irrespectively from their severity. This study sets the basis for the validation of the neuroprosthesis as an alternative, non-invasive means for tremor management., This work has been supported by the Commission of the European Union through grants ICT2007-224051 (TREMOR) and ICT-2011-287739 (NeuroTREMOR), by the Spanish Ministry of Science and Innovation through grants DPI2008-06772-C03-01 (REHABOT) and CSD2009-00067 (HYPER), and by the IMPIVA through grant IMDEEA/2011/91 (SISTR2)., The authors also thank the Unit of Information Resources for Research (URICI-CSIC) for the co-financing of this publication in Open Access., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Influence of common synaptic input to motor neurons on the neural drive to muscle in essential tremor

  • Gallego, Juan Álvaro
  • Dideriksen, Jakob L.
  • Holobar, Ales
  • Ibáñez Pereda, Jaime
  • Pons Rovira, José Luis
  • Louis, Elan D.
  • Rocón, Eduardo
  • Farina, Dario
Tremor in essential tremor (ET) is generated by pathological oscillations at 4 to 12 Hz, likely originating at cerebello-thalamo-cortical pathways. However, the way in which tremor is represented in the output of the spinal cord circuitries is largely unknown because of the difficulties in identifying the behavior of individual motor units from tremulous muscles. By using novel methods for the decomposition of multichannel surface EMG, we provide a systematic analysis of the discharge properties of motor units in 9 ET patients, with concurrent recordings of EEG activity. This analysis allowed inferring the contribution of common synaptic inputs to motor neurons in ET. Motor unit short-term synchronization was significantly greater in ET patients than in healthy subjects. Further, the strong association between the degree of synchronization and the peak in coherence between motor unit spike trains at the tremor frequency indicated that the high synchronization levels were generated mainly by common synaptic inputs specifically at the tremor frequency. The coherence between EEG and motor unit spike trains demonstrated the presence of common cortical input to the motor neurons at the tremor frequency. Nonetheless, the strength of this input was uncorrelated to the net common synaptic input at the tremor frequency, suggesting a contribution of spinal afferents or secondary supraspinal pathways in projecting common input at the tremor frequency. These results provide the first systematic analysis of the neural drive to the muscle in ET and elucidate some of its characteristics that determine the pathological tremulous muscle activity., This work was funded by the EU Commission [grant number EU-FP7-2011-287739 (NeuroTREMOR)]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The phase difference between neural drives to antagonist muscles in essential tremor is associated with the relative strength of supraspinal and afferent input

  • Gallego, Juan Álvaro
  • Dideriksen, Jakob L.
  • Holobar, Ales
  • Ibáñez Pereda, Jaime
  • Glaser, Vojko
  • Romero, Juan Pablo
  • Benito-León, Julián
  • Pons Rovira, José Luis
  • Rocón, Eduardo
  • Farina, Dario
The pathophysiology of essential tremor (ET), the most common movement disorder, is not fully understood. We investigated which factors determine the variability in the phase difference between neural drives to antagonist muscles, a long-standing observation yet unexplained. We used a computational model to simulate the effects of different levels of voluntary and tremulous synaptic input to antagonistic motoneuron pools on the tremor. We compared these simulations to data from 11 human ET patients. In both analyses, the neural drive to muscle was represented as the pooled spike trains of several motor units, which provides an accurate representation of the common synaptic input to motoneurons. The simulations showed that, for each voluntary input level, the phase difference between neural drives to antagonist muscles is determined by the relative strength of the supraspinal tremor input to the motoneuron pools. In addition, when the supraspinal tremor input to one muscle was weak or absent, Ia afferents provided significant common tremor input due to passive stretch. The simulations predicted that without a voluntary drive (rest tremor) the neural drives would be more likely in phase, while a concurrent voluntary input (postural tremor) would lead more frequently to an out-of-phase pattern. The experimental results matched these predictions, showing a significant change in phase difference between postural and rest tremor. They also indicated that the common tremor input is always shared by the antagonistic motoneuron pools, in agreement with the simulations. Our results highlight that the interplay between supraspinal input and spinal afferents is relevant for tremor generation., This work was funded by the European Union Commission (FP7-ICT-2011-287739). Juan A. Gallego received funding from the European Union Commission (FP7-PEOPLE-2013-IOF-627384)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data

  • Lambrecht, Stefan
  • Gallego, Juan Álvaro
  • Rocón, Eduardo
  • Pons Rovira, José Luis
Upper limb tremor is the most prevalent movement disorder and, unfortunately, it is not effectively managed in a large proportion of the patients. Neuroprostheses that stimulate the sensorimotor pathways are one of the most promising alternatives although they are still under development. To enrich the interpretation of data recorded during long-term tremor monitoring and to increase the intelligence of tremor suppression neuroprostheses we need to be aware of the context. Context awareness is a major challenge for neuroprostheses and would allow these devices to react more quickly and appropriately to the changing demands of the user and/or task. Traditionally kinematic features are used to extract context information, with most recently the use of joint angles as highly potential features. In this paper we present two algorithms that enable the robust extraction of joint angle and related features to enable long-term continuous monitoring of tremor with context awareness. First, we describe a novel relative sensor placement identification technique based on orientation data. We focus on relative rather than absolute sensor location, because in many medical applications magnetic and inertial measurement units (MIMU) are used in a chain stretching over adjacent segments, or are always placed on a fixed set of locations. Subsequently we demonstrate how tremor parameters can be extracted from orientation data using an adaptive estimation algorithm. Relative sensor location was detected with an accuracy of 94.12% for the 4 MIMU configuration, and 100% for the 3 MIMU configurations. Kinematic tracking error values with an average deviation of 8% demonstrate our ability to estimate tremor from orientation data. The methods presented in this study constitute an important step toward more user-friendly and context-aware neuroprostheses for tremor suppression and monitoring. © 2014 Lambrecht, Gallego, Rocon and Pons., This work has been funded by the European project NeuroTremor(ICT-2011.5.1-287739)andt he Spanish Consolider project HYPER (CSD2009-00067)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Advances in selective activation of muscles for non-invasive motor neuroprostheses

  • Koutsou, Aikaterini
  • Moreno, Juan Camilo
  • Ama, Antonio J. del
  • Rocón, Eduardo
  • Pons Rovira, José Luis
Non-invasive neuroprosthetic (NP) technologies for movement compensation and rehabilitation remain with challenges for their clinical application. Two of those major challenges are selective activation of muscles and fatigue management. This review discusses how electrode arrays improve the efficiency and selectivity of functional electrical stimulation (FES) applied via transcutaneous electrodes. In this paper we review the principles and achievements during the last decade on techniques for artificial motor unit recruitment to improve the selective activation of muscles. We review the key factors affecting the outcome of muscle force production via multi-pad transcutaneous electrical stimulation and discuss how stimulation parameters can be set to optimize external activation of body segments. A detailed review of existing electrode array systems proposed by different research teams is also provided. Furthermore, a review of the targeted applications of existing electrode arrays for control of upper and lower limb NPs is provided. Eventually, last section demonstrates the potential of electrode arrays to overcome the major challenges of NPs for compensation and rehabilitation of patient-specific impairments., This work has been done with partial financial support of the Ministry of Science and Innovation, in the framework of national project HYPER(CSD 2009-00067- Hybrid Neuroprosthetic and Neurorobotic Devices for Functional Compensation and Rehabilitation of Motor Disorders) and European Union in the framework of TREMOR Project: “TREMOR: An ambulatory BCI-driven tremor suppression system based on functional electrical stimulation”, ICT-2007-224051, and “NeuroTREMOR: A novel concept for support to diagnosis and remote management of tremor”, ICT-2011.5.1-287739., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Brain-controlled neuromuscular stimulation to drive neural plasticity and functional recovery

  • Ethier, Christian
  • Gallego, Juan Álvaro
  • Miller, Lee E.
There is mounting evidence that appropriately timed neuromuscular stimulation can induce neural plasticity and generate functional recovery from motor disorders. This review addresses the idea that coordinating stimulation with a patient's voluntary effort might further enhance neurorehabilitation. Studies in cell cultures and behaving animals have delineated the rules underlying neural plasticity when single neurons are used as triggers. However, the rules governing more complex stimuli and larger networks are less well understood. We argue that functional recovery might be optimized if stimulation were modulated by a brain machine interface, to match the details of the patient's voluntary intent. The potential of this novel approach highlights the need for a better understanding of the complex rules underlying this form of plasticity., Grant #NS053603 from the National Institute of Neurological Disorder and Stroke. Grant #FP7-PEOPLE-2013-IOF-627384 from the European Commission., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A thin-film multichannel electrode for muscle recording and stimulation in neuroprosthetics applications

  • Muceli, S.
  • Poppendieck, W.
  • Hoffmann, K.P.
  • Dosen, S.
  • Benito-León, Julián
  • Barroso, Filipe O.
  • Pons Rovira, José Luis
  • Farina, Dario
Objective. We propose, design and test a novel thin-film multichannel electrode that can be used for both recording from and stimulating a muscle in acute implants. Approach. The system is built on a substrate of polyimide and contains 12 recording and three stimulation sites made of platinum. The structure is 420 μm wide, 20 μm thick and embeds the recording and stimulation contacts on the two sides of the polyimide over an approximate length of 2 cm. We show representative applications in healthy individuals as well as tremor patients. The designed system was tested by a psychometric characterization of the stimulation contacts in six tremor patients and three healthy individuals determining the perception threshold and current limit as well as the success rate in discriminating elicited sensations (electrotactile feedback). Also, we investigated the possibility of using the intramuscular electrode for reducing tremor in one patient by electrical stimulation delivered with timing based on the electromyographic activity recorded with the same electrode. Main results. In the tremor patients, the current corresponding to the perception threshold and the current limit were 0.7 ± 0.2 and 1.4 ± 0.7 mA for the wrist flexor muscles and 0.4 ± 0.2 and 1.5 ± 0.7 mA for the extensors. In one patient, closed-loop stimulation resulted in a decrease of the tremor power >50%. In healthy individuals the perception threshold and current limits were 0.9 ± 0.6 and 2.1 ± 0.6 mA for the extensor carpi radialis muscle. The subjects could distinguish four or six stimulation patterns (two or three stimulation sites × two stimulation current amplitudes) with true positive rate >80% (two subjects) and >60% (one subject), respectively. Significance. The proposed electrode provides a compact multichannel interface for recording electromyogram and delivering electrical stimulation in applications such as neuroprostheses for tremor suppression and closed-loop myoelectric prostheses., This study was financed by the European Projects EXTEND (H2020-ICT-23-2017-779982) and NeuroTREMOR (FP7-ICT-2011-7-287739). The funding agency was not involved in the collection, analyses, and interpretation of data or writing and publication of this article.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Essential tremor severity and anatomical changes in brain areas controlling movement sequencing

  • Benito-León, Julián
  • Serrano, José Ignacio
  • Louis, Elan D.
  • Holobar, Ales
  • Romero, Juan Pablo
  • Povalej‐Bržan, Petra
  • Kranjec, Jernej
  • Bermejo-Pareja, Félix
  • Castillo-Sobrino, M. Dolores del
  • Posada, Ignacio Javier
  • Rocón, Eduardo
Objective: Although the cerebello-thalamo-cortical network has often been suggested to be of importance in the pathogenesis of essential tremor (ET), the origins of tremorgenic activity in this disease are not fully understood. We used a combination of cortical thickness imaging and neurophysiological studies to analyze whether the severity of tremor was associated with anatomical changes in the brain in ET patients. Methods: Magnetic resonance imaging (MRI) and a neurophysiological assessment were performed in 13 nondemented ET patients. High field structural brain MRI images acquired in a 3T scanner and analyses of cortical thickness and surface were carried out. Cortical reconstruction and volumetric segmentation was performed with the FreeSurfer image analysis software. We used high-density surface electromyography (hdEMG) and inertial measurement units (IMUs) to quantify the tremor severity in upper extrimities of patients. In particular, advanced computer tool was used to reliably identify discharge patterns of individual motor units from surface hdEMG and quantify motor unit synchronization. Results: We found significant association between increased motor unit synchronization (i.e., more severe tremor) and cortical changes (i.e., atrophy) in widespread cerebral cortical areas, including the left medial orbitofrontal cortex, left isthmus of the cingulate gyrus, right paracentral lobule, right lingual gyrus, as well as reduced left supramarginal gyrus (inferior parietal cortex), right isthmus of the cingulate gyrus, left thalamus, and left amygdala volumes. Interpretation: Given that most of these brain areas are involved in controlling movement sequencing, ET tremor could be the result of an involuntary activation of a program of motor behavior used in the genesis of voluntary repetitive movements., This work was funded by FEDER grant ; National Institutes of Health grant ; NINDS grants R01 NS39422;, R01 NS094607;, R01 NS085136;, R01 NS073872;, and R01 NS088257; European Commission grant ICT‐2011‐287739; Ministry of Economy and Competitiveness grant RTC‐2015‐3967‐1; Spanish Health Research Agency grants FIS PI12/01602; and FIS PI16/00451; Spanish Ministry of Economy and Competitiveness grants DPI‐2015‐68664‐C4‐1‐R; and DPI2015‐72638‐EXP; Claire O'Neil Essential Tremor Research grant ; Slovenian Research Agency grant J2‐7357.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Graph theory analysis of resting-state functional magnetic resonance imaging in essential tremor

  • Benito-León, Julián
  • Sanz Morales, Emilio
  • Melero, Helena
  • Louis, Elan D.
  • Romero, Juan Pablo
  • Rocón, Eduardo
  • Malpica, Norberto
Essential tremor (ET) is a neurological disease with both motor and nonmotor manifestations; however, little is known about its underlying brain basis. Furthermore, the overall organization of the brain network in ET remains largely unexplored. We investigated the topological properties of brain functional network, derived from resting¿state functional magnetic resonance imaging (MRI) data, in 23 ET patients versus 23 healthy controls. Graph theory analysis was used to assess the functional network organization. At the global level, the functional network of ET patients was characterized by lower small¿worldness values than healthy controls¿less clustered functionality of the brain. At the regional level, compared with the healthy controls, ET patients showed significantly higher values of global efficiency, cost and degree, and a shorter average path length in the left inferior frontal gyrus (pars opercularis), right inferior temporal gyrus (posterior division and temporo¿occipital part), right inferior lateral occipital cortex, left paracingulate, bilateral precuneus bilaterally, left lingual gyrus, right hippocampus, left amygdala, nucleus accumbens bilaterally, and left middle temporal gyrus (posterior part). In addition, ET patients showed significant higher local efficiency and clustering coefficient values in frontal medial cortex bilaterally, subcallosal cortex, posterior cingulate cortex, parahippocampal gyri bilaterally (posterior division), right lingual gyrus, right cerebellar flocculus, right postcentral gyrus, right inferior semilunar lobule of cerebellum and culmen of vermis. Finally, the right intracalcarine cortex and the left orbitofrontal cortex showed a shorter average path length in ET patients, while the left frontal operculum and the right planum polare showed a higher betweenness centrality in ET patients. In conclusion, the efficiency of the overall brain functional network in ET is disrupted. Further, our results support the concept that ET is a disorder that disrupts widespread brain regions, including those outside of the brain regions responsible for tremor., Spanish Ministry of Economy and Competitiveness, Grant/Award Number: DPI‐2015‐72638‐EXP; European Commission, Grant/Award Number: ICT‐2011‐287739; Spanish Ministry of Economy and Competitiveness, Grant/Award Number: DPI‐2015‐68664‐C4‐1‐R; Claire O'Neil Essential Tremor Research Fund; Spanish Health Research Agency, Grant/Award Numbers: FIS PI16/00451, FIS PI12/01602; Ministry of Economy and Competitiveness, Grant/Award Number: RTC‐2015‐3967‐1; National Institutes of Health, Grant/Award Numbers: NINDS #R01 NS088257, NINDS #R01 NS073872, NINDS #R01 NS085136, NINDS #R01 NS094607, NINDS #R01 NS39422, Sí
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A data mining approach for classification of orthostatic and essential tremor based on MRI‐derived brain volume and cortical thickness

  • Benito‐León, Julián
  • Louis, Elan D.
  • Mato‐Abad, Virginia
  • Sánchez‐Ferro, Álvaro
  • Romero, Juan Pablo
  • Matarazzo, Michele
  • Serrano, José Ignacio
Orthostatic tremor (OT) is an extremely rare, misdiagnosed, and underdiagnosed disorder affecting adults in midlife. There is debate as to whether it is a different condition or a variant of essential tremor (ET), or even, if both conditions coexist. Our objective was to use data mining classification methods, using magnetic resonance imaging (MRI)-derived brain volume and cortical thickness data, to identify morphometric measures that help to discriminate OT patients from those with ET. Methods: MRI-derived brain volume and cortical thickness were obtained from 14 OT patients and 15 age-, sex-, and education-matched ET patients. Feature selection and machine learning methods were subsequently applied. Results: Four MRI features alone distinguished the two, OT from ET, with 100% diagnostic accuracy. More specifically, left thalamus proper volume (normalized by the total intracranial volume), right superior parietal volume, right superior parietal thickness, and right inferior parietal roughness (i.e., the standard deviation of cortical thickness) were shown to play a key role in OT and ET characterization. Finally, the left caudal anterior cingulate thickness and the left caudal middle frontal roughness allowed us to separate with 100% diagnostic accuracy subgroups of OT patients (primary and those with mild parkinsonian signs). Conclusions: A data mining approach applied to MRI-derived brain volume and cortical thickness data may differentiate between these two types of tremor with an accuracy of 100%. Our results suggest that OT and ET are distinct conditions., This research was supported by FEDER funds. Benito‐León is supported by the National Institutes of Health, Bethesda, MD, USA (NINDS #R01 NS39422), European Commission (grant ICT‐2011‐287739, NeuroTREMOR), the Ministry of Economy and Competitiveness (grant RTC‐2015‐3967‐1, NetMD – platform for the tracking of movement disorder), and the Spanish Health Research Agency (grant FIS PI12/01602 and grant FIS PI16/00451). Romero is supported by the European Commission (grant ICT‐2011‐287739, NeuroTREMOR) and the Spanish Ministry of Economy and Competitiveness (grant DPI‐2015‐68664‐C4‐1‐R, NeuroMOD). Louis has received research support from the National Institutes of Health: NINDS #R01 NS094607 (principal investigator), NINDS #R01 NS085136 (principal investigator), NINDS #R01 NS073872 (principal investigator), NINDS #R01 NS085136 (principal investigator), and NINDS #R01 NS088257 (principal investigator). He has also received support from the Claire O'Neil Essential Tremor Research Fund (Yale University). Sánchez‐Ferro is supported by the Consejería de Educación, Juventud y Deporte de la Comunidad de Madrid and the People Programme (Marie Curie Actions) of the European Union’s Seventh Framework Programme (FP7/2007‐2013). Serrano is supported by RoboCity2030‐DIH‐CM Madrid Robotics Digital Innovation Hub (“Robótica aplicada a la mejora de la calidad de vida de los ciudadanos. fase IV”; S2018/NMT‐4331), funded by “Programas de Actividades I + D en la Comunidad de Madrid” and cofunded by Structural Funds of the European Commission. We acknowledge the neuropsychologist Verónica Puertas‐Martín, for her assistance with the project., Peer reviewed
Docta Complutense
Publication Artículo científico (JournalArticle)

P300 Wave Alterations and Cognitive Impairment in Cerebellum Lesions

  • Nanda, Sourav
  • Lapeña Motilva, José
  • Kumar Misra, Amar
  • Guha, Gautam
  • Ghosh, Sinjan
  • Manna, Akash
  • Roy, Soumit
  • Benito León, Julián
Abstract Patients with cognitive deficits have a prolonged latency and reduced amplitude of the P300 wave. However, no study has correlated P300 wave alterations with the cognitive performance of patients with cerebellar lesions. We aimed to determine if the cognitive status of these patients was associated with P300 wave alterations. We recruited 30 patients with cerebellar lesions from the wards of the N.R.S. Medical College, Kolkata, in West Bengal (India). The Kolkata Cognitive Screening Battery tasks and the Frontal Assessment Battery (FAB) were used to assess the cognitive status and the International Cooperative Ataxia Rating Scale (ICARS) for cerebellar signs. We compared the results with the normative data of the Indian population. Patients had P300 wave alterations with a significant increase in latency and a non-significant trend in amplitude. In a multivariate model, P300 wave latency was positively associated with the ICARS kinetic subscale (p = 0.005) and age (p = 0.009), regardless of sex and years of education. In the model that included cognitive variables, P300 wave latency was negatively associated with performance in phonemic fluency (p = 0.035) and construction (p = 0.009). Furthermore, P300 wave amplitude was positively associated with the FAB total score (p< 0.001). In closing, patients with cerebellar lesions had an increase in latency and a decrease in the amplitude of the P300 wave. These P300 wave alterations were also associated with worse cognitive performance and some of the subscales of the ICARS, reinforcing that the cerebellum has motor, cognitive, and affective functions.
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data

  • Lambrecht, Stefan
  • Gallego Juárez, Juan Antonio
  • Rocón de Lima, Eduardo
  • Pons Rovira, José Luis
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Influence of common synaptic input to motor neurons on the neural drive to muscle in essential tremor

  • Gallego Juárez, Juan Antonio
  • Dideriksen, Jacob L.
  • Holobar, Ales
  • Ibañez Pereda, Jaime
  • Pons Rovira, José Luis
  • Louis, Elan D.
  • Rocón de Lima, Eduardo
  • Farina, Darío
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Essential tremor severity and anatomical changes in brain areas controlling movement sequencing

  • Benito León, Julián
  • Serrano Moreno, José Ignacio
  • Louis, Elan D.
  • Holobar, Ales
  • Romero, Juan P.
  • Povalej-Brzan, Petra
  • Kranjec, Jernej
  • Bermejo Pareja, Félix
  • Castillo Sobrino, Maria Dolores del
  • Posada Rodríguez, Ignacio Javier
  • Rocón De Lima, Eduardo