Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Optimization of Beryllium-10 detection using a 1MV AMS dystem

  • Almecci, Sarmadi
Póster presentado al "1st oPAC Topical Workshop: Grand ChallengesAccelerator Optimization" celebrado en Zurich (Suiza) del 26 al 27 de junio de 2013., This project is funded by the European Union under contract PITN-GA-2011-289485., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Recent developments of the 1 MV AMS facility at the Centro Nacional de Aceleradores

  • Scognamiglio, Grazia
  • Chamizo, Elena
  • López-Gutiérrez, J. M.
  • Müller, A. M.
  • Padilla, Santiago
  • Santos, F. J.
  • López-Lora, Mercedes
  • Vivo Vilches, Carlos
  • García-León, Manuel
The Centro Nacional de Aceleradores (CNA) hosts a 1 MV accelerator mass spectrometry (AMS) apparatus since September 2005. In order to improve its overall performance, several updates have been made on the existing facility during the last 10 years of operation. In this paper, two modifications conducted in 2015 will be described. To increase the transmission of the ions through the accelerator, the stripping gas on the 1 MV CNA machine was changed from Ar to He. The measured maximum transmission for almost every isotope results to be higher, especially for heavy masses: for instance, in the case of uranium in the 3+ charge state, the transmission increased from 11% with Ar gas to about 38% with He gas. The second advance consisted of the substitution of the existing gas ionization chamber with a new one provided by ETH Zurich. The ETH detector features with its miniaturized design and is optimized for low energy AMS (i.e. very low electronic noise and efficient charge collection). As the electronic noise is the most important contribution to the resolution for light ions, the total energy resolution has been reduced by 15% in the case of Be, allowing a better discrimination against its isobar, B. For the heaviest radionuclides where the quality of the spectra is determined by the charge carrier production in the gas, the resolution for 2.7 MeV uranium ions was improved by 30%, probably due to a more efficient charge collection., This project has received funding from the project FIS2012-31853 and from the European Union’s Seventh Framework Program for research, technological development and demonstration under grant agreement No 289485., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Dosimetric response of radiochromic films to protons of low energies in the Bragg peak region

  • Battaglia, M. C.
  • Schardt, D.
  • Espino, J. M.
  • Gallardo, María Isabel
  • Cortés-Giraldo, Miguel Antonio
  • Quesada, José Manuel
  • Lallena, A. M.
  • Miras, H.
  • Guirado, D.
An article within the collection: oPAC 2015 Conference Edition., One of the major advantages of proton or ion beams, applied in cancer treatment, is their excellent depth-dose profile exhibiting a low dose in the entrance channel and a distinct dose maximum (Bragg peak) near the end of range in tissue. In the region of the Bragg peak, where the protons or ions are almost stopped, experimental studies with low-energy particle beams and thin biological samples may contribute valuable information on the biological effectiveness in the stopping region. Such experiments, however, require beam optimization and special dosimetry techniques for determining the absolute dose and dose homogeneity for very thin biological samples. At the National Centre of Accelerators in Seville, one of the beam lines at the 3 MV Tandem Accelerator was equipped with a scattering device, a special parallel-plate ionization chamber with very thin electrode foils and target holders for cell cultures. In this work, we present the calibration in absolute dose of EBT3 films [Gafchromic radiotherapy films, http://www.ashland.com/products/gafchromic-radiotherapy-films] for proton energies in the region of the Bragg peak, where the linear energy transfer increases and becomes more significant for radiobiology studies, as well as the response of the EBT3 films for different proton energy values. To irradiate the films in the Bragg peak region, the energy of the beam was degraded passively, by interposing Mylar foils of variable thickness to place the Bragg peak inside the active layer of the film. The results obtained for the beam degraded in Mylar foils are compared with the dose calculated by means of the measurement of the beam fluence with an ionization chamber and the energy loss predicted by srim2008 code., This work is supported by the EU Initial Training Marie Curie Network 289485 “Optimization of particle accelerators” (FP7-PEOPLE-2011-ITN-289485); by the Spanish Research Projects No. FPA2014-53290-C2-2-P and No. FPA2013-47327-C2-1-R; by the Andalusian Research Project No. P12-FQM-1605., Peer reviewed
idUS. Depósito de Investigación de la Universidad de Sevilla
Publication Artículo científico (JournalArticle)

Dosimetric response of radiochromic films to protons of low energies in the Bragg peak region

  • Quesada Molina, José Manuel
  • Espino Navas, José Manuel
  • Gallardo Fuentes, María Isabel
  • Cortés Giraldo, Miguel Antonio
  • Battaglia, Maria Cristina
  • Miras, H.
  • Lallena Rojo, Antonio Miguel
  • Guirado, D.
  • Schardt, D.
One of the major advantages of proton or ion beams, applied in cancer treatment, is their excellent depth-dose profile exhibiting a low dose in the entrance channel and a distinct dose maximum (Bragg peak) near the end of range in tissue. In the region of the Bragg peak, where the protons or ions are almost stopped, experimental studies with low-energy particle beams and thin biological samples may contribute valuable information on the biological effectiveness in the stopping region. Such experiments, however, require beam optimization and special dosimetry techniques for determining the absolute dose and dose homogeneity for very thin biological samples. At the National Centre of Accelerators in Seville, one of the beam lines at the 3 MV Tandem Accelerator was equipped with a scattering device, a special parallel-plate ionization chamber with very thin electrode foils and target holders for cell cultures. In this work, we present the calibration in absolute dose of EBT3 films [Gafchromic radiotherapy films, http://www.ashland.com/products/gafchromic-radiotherapy-films] for proton energies in the region of the Bragg peak, where the linear energy transfer increases and becomes more significant for radiobiology studies, as well as the response of the EBT3 films for different proton energy values. To irradiate the films in the Bragg peak region, the energy of the beam was degraded passively, by interposing Mylar foils of variable thickness to place the Bragg peak inside the active layer of the film. The results obtained for the beam degraded in Mylar foils are compared with the dose calculated by means of the measurement of the beam fluence with an ionization chamber and the energy loss predicted by srim2008 code., EU Initial Training Marie Curie Network FP7-PEOPLE-2011-ITN-289485, Spanish Research Projects No. FPA2014-53290-C2-2-P, Spanish Research Projects No. FPA2013-47327-C2-1-R, Andalusian Research Project No. P12-FQM-1605