Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Ultrafine and nanoparticle formation and emission mechanisms during laser processing of ceramic materials

  • Fonseca, Ana Sofía
  • Viana, Mar
  • Querol, Xavier
  • Francisco, I. de
  • Estepa, L. C.
  • Fuente, Germán F. de la
The use of laser technology in the ceramic industry is undergoing an increasing trend, as it improves surface properties. The present work aimed to assess ultrafine and nanoparticle emissions from two different types of laser treatments (tile sintering and ablation) applied to two types of tiles. New particle formation mechanisms were identified, as well as primary nanoparticle emissions, with concentrations reaching up to 6.7×10<sup>6</sup>particlescm<sup>-3</sup> and a mean diameter of 18nm. Nanoparticle emission patterns were strongly dependent on temperature and raw tile chemical composition. Nucleation events were detected during the thermal treatment independently of the laser application. TEM images evidenced spherical ultrafine particles, originating from the tile melting processes. When transported across the indoor environment, particles increased in size (up to 38nm) with concentrations remaining high (2.3×10<sup>6</sup>particlescm<sup>-3</sup>). Concentrations of metals such as Zn, Pb, Cu, Cr, As and TI were found in particles <250nm., This study was supported by the European Community׳s Seventh Framework Program (FP7-PEOPLE-2012-ITN) under Grant no. 315760 (HEXACOMM Project) and by the National Project IMPACT (CGL2011-26574). Additional funding was provided by LIFE projects AIRUSE (LIFE11 ENV/ES/584), CERAMGLASS (LIFE11 ENV/ES/560) and LASERFIRING (LIFE09 ENV/ES/435)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Process-generated nanoparticles from ceramic tile sintering: Emissions, exposure and environmental release

  • Fonseca, Ana Sofía
  • Viana, Mar
  • Querol, Xavier
  • Francisco, I. de
  • Estepa, L. C.
  • Borrell, Carme
  • Lennikov, V.
  • Fuente, Germán F. de la
Under a Creative Commons license.-- et al., The ceramic industry is an industrial sector in need of significant process changes, which may benefit from innovative technologies such as laser sintering of ceramic tiles. Such innovations result in a considerable research gap within exposure assessment studies for process-generated ultrafine and nanoparticles. This study addresses this issue aiming to characterise particle formation, release mechanisms and their impact on personal exposure during a tile sintering activity in an industrial-scale pilot plant, as a follow-up of a previous study in a laboratory-scale plant. In addition, possible particle transformations in the exhaust system, the potential for particle release to the outdoor environment, and the effectiveness of the filtration system were also assessed. For this purpose, a tiered measurement strategy was conducted. The main findings evidence that nanoparticle emission patterns were strongly linked to temperature and tile chemical composition, and mainly independent of the laser treatment. Also, new particle formation (from gaseous precursors) events were detected, with nanoparticles < 30 nm in diameter being formed during the thermal treatment. In addition, ultrafine and nano-sized airborne particles were generated and emitted into workplace air during sintering process on a statistically significant level. These results evidence the risk of occupational exposure to ultrafine and nanoparticles during tile sintering activity since workers would be exposed to concentrations above the nano reference value (NRV; 4 × 10 cm), with 8-hour time weighted average concentrations in the range of 1.4 × 10 cm and 5.3 × 10 cm. A potential risk for nanoparticle and ultrafine particle release to the environment was also identified, despite the fact that the efficiency of the filtration system was successfully tested and evidenced a > 87% efficiency in particle number concentrations removal., This work was supported by the European Commission FP7 (FP7-PEOPLE-2012-ITN) Marie Curie ITN project no. 315760 (HEXACOMM) and by the Spanish MINECO (PCIN-2015-173-C02-01) under the frame of SIINN, the ERA-NET for a Safe Implementation of Innovative Nanoscience and Nanotechnology, through SIINN-ERANET project CERASAFE (id.:16). Additional support was provided by LIFE projects AIRUSE (LIFE11 ENV/ES/584), CERAMGLASS (LIFE11 ENV/ES/560) and LASERFIRING (LIFE09 ENV/ES/435)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Intercomparison of a portable and two stationary mobility particle sizers for nanoscale aerosol measurements

  • Fonseca, Ana Sofía
  • Viana, Mar
  • Alastuey, Andrés
  • Querol, Xavier
  • Kaminski, H.
  • Todea, M.
  • Monz, C.
  • Asbach, C.
During occupational exposure studies, the use of conventional scanning mobility particle sizers (SMPS) provides high quality data but may convey transport and application limitations. New instruments aiming to overcome these limitations are being currently developed. The purpose of the present study was to compare the performance of the novel portable NanoScan SMPS TSI 3910 with that of two stationary SMPS instruments and one ultrafine condensation particle counter (UCPC) in a controlled atmosphere and for different particle types and concentrations. The results show that NanoScan tends to overestimate particle number concentrations with regard to the UCPC, particularly for agglomerated particles (ZnO, spark generated soot and diesel soot particles) with relative differences >20%. The best agreements between the internal reference values and measured number concentrations were obtained when measuring compact and spherical particles (NaCl and DEHS particles). With regard to particle diameter (modal size), results from NanoScan were comparable < [± 20%] to those measured by SMPSs for most of the aerosols measured. The findings of this study show that mobility particle sizers using unipolar and bipolar charging may be affected differently by particle size, morphologies, particle composition and concentration. While the sizing accuracy of the NanoScan SMPS was mostly within ±25%, it may miscount total particle number concentration by more than 50% (especially for agglomerated particles), thus making it unsuitable for occupational exposure assessments where high degree of accuracy is required (e.g., in tier 3). However, can be a useful instrument to obtain an estimate of the aerosol size distribution in indoor and workplace air, e.g., in tier 2., This work was supported by grants from the European Community's FP7 (FP7-PEOPLE-2012-ITN) no. 315760 (HEXACOMM project). Additional support was provided by European project nanoIndEx which is supported by the French National Funding Agency for Research (ANR), the German Federal Ministry of Education and Research (BMBF, IUTA grant no.: 03×0127A), the British Technology Strategy Board (TSB) and the Swiss TEMAS AG, under the frame of SIINN, the ERA-NET for a Safe Implementation of Innovative Nanoscience and Nanotechnology., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Aerosol sources in subway environments

  • Minguillón, María Cruz
  • Reche, Cristina
  • Martins, Vânia
  • Amato, Fulvio
  • de Miguel, Eladio
  • Capdevila, Marta
  • Centelles, Sonia
  • Querol, Xavier
  • Moreno, Teresa
Millions of people use rail subway public transport around the world, despite the relatively high particulate matter (PM) concentrations in these underground environments, requiring the identification and quantification of the aerosol source contributions to improve the air quality. An extensive aerosol monitoring campaign was carried out in eleven subway stations in the Barcelona metro system, belonging to seven subway lines. PM2.5 samples were collected during the metro operating hours and chemically analysed to determine major and trace elements, inorganic ions, and total carbon. The chemical compositions of subway components such as brake pads, rail tracks and pantographs were also determined. The mean PM2.5 concentrations varied widely among stations, ranging from 26 µg m−3 to 86 µg m−3. Subway PM2.5 was mainly constituted by Fe2O3 (30–66%), followed by carbonaceous matter (18–37%) for the old stations, while for new stations equipped with Platform Screen Doors (PSD) these percentages go down to 21–44% and 15–30%, respectively. Both the absolute concentrations and the relative abundance of key species differed for each subway station, although with common patterns within a given subway line. This is a result of the different emission chemical profiles in different subway lines (using diverse types of brakes and/or pantographs). The co-emission of different sources poses a problem for their separation by receptor models. Nevertheless, receptor modelling (Positive Matrix Factorization) was applied resulting in ten sources, five of them subway-specific: RailWheel, RailWheel+Brake, Brake_A, Brake_B, Pb. The sum of their contributions accounted for 43–91% of bulk PM2.5 for the old stations and 21–52% for the stations with PSD. The decrease of the activity during the weekends resulted in a decrease (up to 56%) in the subway-specific sources contribution to the –already lower– bulk PM2.5 concentrations compared to weekdays. The health-related elements are mainly apportioned (> 60%) by subway sources. © 2018 The Authors, This work was supported by the European IMPROVE LIFE+ project (LIFE13 ENV/ES/000263 ), the Spanish Ministry of Economy and Competitiveness with FEDER funds (METRO CGL2012–33066 ), the EU Seventh Framework Programme (FP7/2007–2013) under grant agreement n° 315760 HEXACOMM, and the Generalitat de Catalunya (AGAUR 2017 SGR41). M.C. Minguillón acknowledges the Ramón y Cajal fellowship awarded by the Spanish Ministry of Economy, Industry and Competitiveness . Appendix A, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Workplace exposure and release of ultrafine particles during atmospheric plasma spraying in the ceramic industry

  • Viana, Mar
  • Fonseca, Ana Sofía
  • Querol, Xavier
  • Querol, Xavier
  • Carpio, Pablo
  • Salmatonidis, Apostolos
  • Monfort, E.
Atmospheric plasma spraying (APS) is a frequently used technique to produce enhanced-property coatings for different materials in the ceramic industry. This work aimed to characterise and quantify the impact of APS on workplace exposure to airborne particles, with a focus on ultrafine particles (UFPs, < 100 nm) and nanoparticles (< 50 nm). Particle number, mass concentrations, alveolar lung deposited surface area concentration, and size distributions, in the range 10 nm–20 μm were simultaneously monitored at the emission source, in the potential worker breathing zone, and in outdoor air. Different input materials (known as feedstock) were tested: (a) micron-sized powders, and (b) suspensions containing submicron- or nano-sized particles. Results evidenced significantly high UFP concentrations (up to 3.3 × 106/cm3) inside the spraying chamber, which impacted exposure concentrations in the worker area outside the spraying chamber (up to 8.3 × 105/cm3). Environmental release of UFPs was also detected (3.9 × 105/cm3, outside the exhaust tube). Engineered nanoparticle (ENP) release to workplace air was also evidenced by TEM microscopy. UFP emissions were detected during the application of both micron-sized powder and suspensions containing submicron- or nano-sized particles, thus suggesting that emissions were process- (and not material-) dependent. An effective risk prevention protocol was implemented, which resulted in a reduction of UFP exposure in the worker area. These findings demonstrate the potential risk of occupational exposure to UFPs during atmospheric plasma spraying, and raise the need for further research on UFP formation mechanisms in high-energy industrial processes. © 2017 The Authors, This project was supported by the Spanish MINECO through project PCIN-2015-173-C02-01, under the frame of SIINN, the ERA-NET for a Safe Implementation of Innovative Nanoscience and Nanotechnology, by SIINN-ERANET project CERASAFE (id.:16). Support is also acknowledged to FP7 Marie Curie ITN HEXACOMM (Nr. 315760), Generalitat de Catalunya (AGAUR SGR33), and the Spanish Ministry of the Environment (13CAES006)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Atmospheric Environment

  • Moreno, Teresa
  • Kelly, Frank J.
  • Dunster, Christina A.
  • Oliete, Ana
  • Martins, Vânia
  • Reche, Cristina
  • Minguillón, María Cruz
  • Amato, Fulvio
  • Capdevila, Marta
  • de Miguel, Eladio
  • Querol, Xavier
Air quality in subway systems is of interest not only because particulate matter (PM) concentrations can be high, but also because of the peculiarly metalliferous chemical character of the particles, most of which differ radically from those of outdoor ambient air. We report on the oxidative potential (OP) of PM2.5 samples collected in the Barcelona subway system in different types of stations. The PM chemical composition of these samples showed typically high concentrations of Fe, Total Carbon, Ba, Cu, Mn, Zn and Cr sourced from rail tracks, wheels, catenaries, brake pads and pantographs. Two toxicological indicators of oxidative activity, ascorbic acid (AA) oxidation (expressed as OPAA μg−1 or OPAA m−3) and glutathione (GSH) oxidation (expressed as OPGSH μg−1 or OPGSH m−3), showed low OP for all samples (compared with outdoor air) but considerable variation between stations (0.9–2.4 OPAA μg−1; 0.4–1.9 OPGSH μg−1). Results indicate that subway PM toxicity is not related to variations in PM2.5 concentrations produced by ventilation changes, tunnel works, or station design, but may be affected more by the presence of metallic trace elements such as Cu and Sb sourced from brakes and pantographs. The OP assays employed do not reveal toxic effects from the highly ferruginous component present in subway dust. © 2016 The Authors, This study was supported by the Spanish Ministry of Economy and Competitiveness and FEDER funds (METRO CGL2012-33066 ), the I MPROVE LIFE Project ( LIFE13 ENV/ES/000263 ) and the European Union Seventh Framework Programme ( FP7/2007-2013 ) under grant agreement no. 315760 HEXACOMM. Support is also acknowledged to Generalitat de Catalunya 2014 SGR33 . Fulvio Amato is beneficiary of an AXA Research Fund postdoctoral grant . In the UK the research was funded by the National Institute for Health Research Health Protection Research Unit (NIHR HPRU) in Health Impact of Environmental Hazards at King's College London in partnership with Public Health England (PHE). The views expressed are those of the authors and not necessarily those of the NHS, the NIHR, the Department of Health or Public Health England. Special thanks to Wes Gibbons for improving an early draft of the manuscript. Appendix A, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Factors controlling air quality in different European subway systems

  • Martins, Vânia
  • Moreno, Teresa
  • Querol, Xavier
  • Minguillón, María Cruz
Sampling campaigns using the same equipment and methodology were conducted to assess and compare the air quality at three South European subway systems (Barcelona, Athens and Oporto), focusing on concentrations and chemical composition of PM2.5 on subway platforms, as well as PM2.5 concentrations inside trains. Experimental results showed that the mean PM2.5 concentrations widely varied among the European subway systems, and even among different platforms within the same underground system, which might be associated to distinct station and tunnel designs and ventilation systems. In all cases PM2.5 concentrations on the platforms were higher than those in the urban ambient air, evidencing that there is generation of PM2.5 associated with the subway systems operation. Subway PM2.5 consisted of elemental iron, total carbon, crustal matter, secondary inorganic compounds, insoluble sulphate, halite and trace elements. Of all metals, Fe was the most abundant, accounting for 29-43% of the total PM2.5 mass (41-61% if Fe2O3 is considered), indicating the existence of an Fe source in the subway system, which could have its origin in mechanical friction and wear processes between rails, wheels and brakes. The trace elements with the highest enrichment in the subway PM2.5 were Ba, Cu, Mn, Zn, Cr, Sb, Sr, Ni, Sn, Co, Zr and Mo. Similar PM2.5 diurnal trends were observed on platforms from different subway systems, with higher concentrations during subway operating hours than during the transport service interruption, and lower levels on weekends than on weekdays. PM2.5 concentrations depended largely on the operation and frequency of the trains and the ventilation system, and were lower inside the trains, when air conditioning system was operating properly, than on the platforms. However, the PM2.5 concentrations increased considerably when the train windows were open. The PM2.5 levels inside the trains decreased with the trains passage in aboveground sections. © 2015 The Authors., The present study was supported by the European Union Seventh Framework Programme (FP7/2007-2013) under Grant agreement no. 315760 HEXACOMM, the Spanish Ministry of Economy and Competitiveness and FEDER funds (METRO CGL2012-33066 ), the IMPROVE LIFE project ( LIFE13 ENV/ES/000263 ), and the Generalitat de Catalunya 2014 SGR33 . The authors also gratefully acknowledge the permission and collaboration from the Transports Metropolitans de Barcelona, the URBAN RAIL TRANSPORT S.A. for ATHENS Metro and the Metro do Porto S.A. to undertake this work. Special thanks are given to Dr Cristina Reche for supplying outdoor ambient data from Barcelona and to Catarina Silva for carried out the TC chemical analyses of Oporto subway samples. Appendix A, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A new look at inhalable metalliferous airborne particles on rail subway platforms

  • Moreno, Teresa
  • Martins, Vânia
  • Querol, Xavier
  • Jones, Tim Peter
  • Jones, Tim Peter
  • Minguillón, María Cruz
  • Amato, Fulvio
  • Capdevila, Marta
  • de Miguel, Eladio
  • Centelles, Sonia
  • Gibbons, Wes
Most particles breathed on rail subway platforms are highly ferruginous (FePM) and extremely small (nanometric to a few microns in size). High magnification observations of particle texture and chemistry on airborne PM10 samples collected from the Barcelona Metro, combined with published experimental work on particle generation by frictional sliding, allow us to propose a general model to explain the origin of most subway FePM. Particle generation occurs by mechanical wear at the brake-wheel and wheel-rail interfaces, where magnetic metallic flakes and splinters are released and undergo progressive atmospheric oxidation from metallic iron to magnetite and maghemite. Flakes of magnetite typically comprise mottled mosaics of octahedral nanocrystals (10-20nm) that become pseudomorphed by maghemite. Continued oxidation results in extensive alteration of the magnetic nanostructure to more rounded aggregates of non-magnetic hematite nanocrystals, with magnetic precursors (including iron metal) still preserved in some particle cores. Particles derived from steel wheel and rails contain a characteristic trace element chemistry, typically with Mn/Fe=0.01. Flakes released from brakes are chemically very distinctive, depending on the pad composition, being always carbonaceous, commonly barium-rich, and texturally inhomogeneous, with trace elements present in nanominerals incorporated within the crystalline structure. In the studied subway lines of Barcelona at least there appears to be only a minimal aerosol contribution from high temperature processes such as sparking. To date there is no strong evidence that these chemically and texturally complex inhalable metallic materials are any more or less toxic than street-level urban particles, and as with outdoor air, the priority in subway air quality should be to reduce high mass concentrations of aerosol present in some stations. © 2014., This work was supported by the + D Project CGL2012-33066 (METRO), the Spanish Ministry of Economy and Competitiveness and FEDER funds within the I European Union Seventh Framework Programme (FP7/2007–2013) under grant agreement no. 315760 HEXACOMM and the IMPROVE LIFE project ( LIFE13 ENV/ES/000263 ). F. Amato is beneficiary of an AXA Research Fund postdoctoral grant. We acknowledge useful discussion with our colleague Greg Power., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Origin of inorganic and organic components of PM2.5 in subway stations of Barcelona, Spain

  • Martins, Vânia
  • Moreno, Teresa
  • Minguillón, María Cruz
  • Van Drooge, Barend L.
  • Reche, Cristina
  • Amato, Fulvio
  • de Miguel, Eladio
  • Capdevila, Marta
  • Centelles, Sonia
  • Querol, Xavier
The present work assesses indoor air quality in stations of the Barcelona subway system. PM2.5 concentrations on the platforms of 4 subway stations were measured during two different seasons and the chemical composition was determined. A Positive Matrix Factorization analysis was performed to identify and quantify the contributions of major PM2.5 sources in the subway stations. Mean PM2.5 concentrations varied according to the stations design and seasonal periods. PM2.5 was composed of haematite, carbonaceous aerosol, crustal matter, secondary inorganic compounds, trace elements, insoluble sulphate and halite. Organic compounds such as PAHs, nicotine, levoglucosan and aromatic musk compounds were also identified. Subway PM2.5 source comprised emissions from rails, wheels, catenaries, brake pads and pantographs. The subway source showed different chemical profiles for each station, but was always dominated by Fe. Control actions on the source are important for the achievement of better air quality in the subway environment. © 2015 The Authors., The present study was supported by the European Union Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 315760 HEXACOMM, the Spanish Ministry of Economy and Competitiveness and FEDER funds ( METRO CGL2012-33066 ), and the IMPROVE LIFE project ( LIFE13 ENV/ES/000263 ). Fulvio Amato is beneficiary of an AXA Research Fund postdoctoral grant. The authors would like to thank the Transports Metropolitans de Barcelona METRO staff who arranged the sampling campaign and contributed actively to this work. Appendix A, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Exposure to airborne particulate matter in the subway system

  • Martins, Vânia
  • Moreno, Teresa
  • Minguillón, María Cruz
  • Amato, Fulvio
  • de Miguel, E.
  • Capdevila, M.
  • Querol, Xavier
© 2014 The Authors. The Barcelona subway system comprises eight subway lines, at different depths, with different tunnel dimensions, station designs and train frequencies. An extensive measurement campaign was performed in this subway system in order to characterise the airborne particulate matter (PM) measuring its concentration and investigating its variability, both inside trains and on platforms, in two different seasonal periods (warmer and colder), to better understand the main factors controlling it, and therefore the way to improve air quality. The majority of PM in the underground stations is generated within the subway system, due to abrasion and wear of rail tracks, wheels and braking pads caused during the motion of the trains. Substantial variation in average PM concentrations between underground stations was observed, which might be associated to different ventilation and air conditioning systems, characteristics/design of each station and variations in the train frequency. Average PM2.5 concentrations on the platforms in the subway operating hours ranged from 20 to 51 and from 41 to 91μgm-3 in the warmer and colder period, respectively, mainly related to the seasonal changes in the subway ventilation systems. The new subway lines with platform screen doors showed PM2.5 concentrations lower than those in the conventional system, which is probably attributable not only to the more advanced ventilation setup, but also to the lower train frequency and the design of the stations. PM concentrations inside the trains were generally lower than those on the platforms, which is attributable to the air conditioning systems operating inside the trains, which are equipped with air filters. This study allows the analysis and quantification of the impact of different ventilation settings on air quality, which provides an improvement on the knowledge for the general understanding and good management of air quality in the subway system., This study was supported by the Spanish Ministry of Economy and Competitiveness and FEDER funds (METRO CGL2012-33066), the European Union Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 315760 HEXACOMM and the IMPROVE LIFE Project (LIFE13 ENV/ES/000263). Fulvio Amato is a beneficiary of an AXA Research Fund postdoctoral grant. The authors would like to thank the Transports Metropolitans de Barcelona METRO staff who arranged the sampling campaign and contributed actively to this work.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Ultrafine and nanoparticle formation and emission mechanisms during laser processing of ceramic materials

  • Fonseca, A.S.
  • Viana, M.
  • Querol, X.
  • Moreno, N.
  • de Francisco, I.
  • Estepa, C.
  • de la Fuente, G.F.
The use of laser technology in the ceramic industry is undergoing an increasing trend, as it improves surface properties. The present work aimed to assess ultrafine and nanoparticle emissions from two different types of laser treatments (tile sintering and ablation) applied to two types of tiles. New particle formation mechanisms were identified, as well as primary nanoparticle emissions, with concentrations reaching up to 6.7 x 10(6) particles Cm-3 and a mean diameter of 18 nm. Nanoparticle emission patterns were strongly dependent on temperature and raw tile chemical composition. Nucleation events were detected during the thermal treatment independently of the laser application. TOM images evidenced spherical ultrafine particles, originating from the tile melting processes. When transported across the indoor environment, particles increased in size (up to 38 nm) with concentrations remaining high (2.3 x 10(6) particles cm(-3)), Concentrations of metals such as Zn, Pb, Cu, Cr, As and al were found in particles < 250 nm.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Process-generated nanoparticles from ceramic tile sintering: Emissions, exposure and environmental release

  • Fonseca, A.S.
  • Maragkidou, A.
  • Viana, M.
  • Querol, X.
  • Hameri, K.
  • de Francisco, I.
  • Estepa, C.
  • Borrell, C.
  • Lennikov, V.
  • de la Fuente, G.F.
The ceramic industry is an industrial sector in need of significant process changes, which may benefit from innovative technologies such as laser sintering of ceramic tiles. Such innovations result in a considerable research gap within exposure assessment studies for process-generated ultrafine and nanoparticles. This study addresses this issue aiming to characterise particle formation, release mechanisms and their impact on personal exposure during a tile sintering activity in an industrial-scale pilot plant, as a follow-up of a previous study in a laboratory-scale plant. In addition, possible particle transformations in the exhaust system, the potential for particle release to the outdoor environment, and the effectiveness of the filtration system were also assessed. For this purpose, a tiered measurement strategy was conducted. The main findings evidence that nanoparticle emission patterns were strongly linked to temperature and tile chemical composition, and mainly independent of the laser treatment. Also, new particle formation (from gaseous precursors) events were detected, with nanoparticles <30 nm in diameter being formed during the thermal treatment. In addition, ultrafine and nano-sized airborne particles were generated and emitted into workplace air during sintering process on a statistically significant level. These results evidence the risk of occupational exposure to ultrafine and nanoparticles during tile sintering activity since workers would be exposed to concentrations above the nano reference value (NRV; 4 x 10(4) cm(-3)), with 8-hour time weighted average concentrations in the range of 1.4 x 10(5) cm(-3) and 5.3 x 10(5) cm(-3). A potential risk for nanoparticle and ultrafine particle release to the environment was also identified, despite the fact that the efficiency of the filtration system was successfully tested and evidenced a >87% efficiency in particle number concentrations removal.