Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Development length of prestressing strands in pretensioned geopolymer concrete beams

  • Li, Teng
  • Ma, Gao
  • Shi, Caijun
  • Navarro-Gregori, Juan|||0000-0002-6319-7029
  • Martí Vargas, José Rocío|||0000-0003-1665-2348
[EN] Geopolymers constitute a feasible alternative to ordinary Portland cement, as they involve a lower environmental footprint. Consequently, geopolymer concrete (GC) has emerged as a sustainable structural engineering material. Research has been conducted on GC in reinforced concrete structures, but its use in prestressed structures is not widespread, and the applicability of design provisions, such as the development length (DL) of prestressing strands, remains unverified. Thus, the objective of this paper is to contribute specific pioneering experimental DL results in GC and to assess the applicability of existing DL equations. The DLs of 12.7 and 15.2 mm Grade 270 (1860 MPa) steel strands in twelve pretensioned, prestressed concrete beams (PPCBs) cast with three different GC grades (30, 50, and 70 MPa) and with initial prestress ranging from 0.65 to 0.75fpu were determined. Three PPCBs of ordinary concrete (OC) were also tested as a reference. Flexural testing was performed twice on each PPCB with two different embedment lengths. Moment-deflection and strand end slips, together with cracking patterns and failure modes, were analyzed. The test results show that DL is closely related to concrete strength, strand diameter, and prestress level. Similar DLs were obtained in GC and OC for all concrete grades, whereas the respective transfer and flexural bond lengths can be different. A new DL equation for GC is proposed, and comparisons with predictions from existing equations are performed., This research was sponsored by the National Natural Science Foundation of China (Grant No. 51638008) , and the Huxiang Youth Talent Support Program of Hunan Province, China (2021RC3041) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluation of transfer length in pretensioned geopolymer concrete beams

  • Li, Teng
  • Ma, Gao
  • Hwang, Hyeon-Jong
  • Shi, Caijun
  • Martí Vargas, José Rocío|||0000-0003-1665-2348
[EN] The emergence of geopolymer concrete (GC) is making a positive contribution to environmental sustainability in construction. However, GC has not been extensively used in prestressed structures, so the applicability of design provisions remains unverified. In particular, the use of strands in GC structures requires the determination of their transfer lengths. This paper evaluates the transfer lengths of 12.7 and 15.2 mm Grade 270 (1860 MPa) steel strands in beams cast with three different grades (30, 50 and 70 MPa). Initial prestress of 0.65-0.75fpu was applied and gradually released. The transfer lengths were measured by applying the 95 % Average Maximum Strain Method. The strain field at one beam end was also obtained using Digital Image Correlation, which provided a new way to analyze the Hoyer effect. The tests showed that the transfer length was closely related to concrete compressive strength at release, prestress level and strand diameter. Moreover, the transfer length values in GC members were similar compared to ordinary concrete members for grades 50 and 70 MPa concrete and shorter for 30 MPa GC members. Prediction results from several international design codes and existing equations were obtained, which are close or conservative compared to the experimental results., This research was sponsored by the National Natural Science Foun-dation of China (Grant No. 51638008) , the Huxiang Youth Talent Sup-port Program of Hunan Province, China (2021RC3041) .