Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Process monitoring of moisture content and mass transfer rate in a fluidised bed with a low cost inline MEMS NIR sensor

  • Avila, Claudio R.
  • Ferré, Joan
  • Rocha de Oliveira, Rodrigo
  • Juan Capdevila, Anna de
  • Sinclair, Wayne E.
  • Mahdi, Faiz M.
  • Hassanpour, Ali
  • Hunter, Timothy N.
  • Bourne, Richard A.
  • Muller, Frans L.
Purpose The current trend for continuous drug product manufacturing requires new, affordable process analytical techniques (PAT) to ensure control of processing. This work evaluates whether property models based on spectral data from recent Fabry-Pérot Interferometer based NIR sensors can generate a high-resolution moisture signal suitable for process control. Methods Spectral data and offline moisture content were recorded for 14 fluid bed dryer batches of pharmaceutical granules. A PLS moisture model was constructed resulting in a high resolution moisture signal, used to demonstrate (i) endpoint determination and (ii) evaluation of mass transfer performance. Results The sensors appear robust with respect to vibration and ambient temperature changes, and the accuracy of water content predictions (±13%) is similar to those reported for high specification NIR sensors. Fusion of temperature and moisture content signal allowed monitoring of water transport rates in the fluidised bed and highlighted the importance water transport within the solid phase at low moisture levels. The NIR data was also successfully used with PCA-based MSPC models for endpoint detection. Conclusions The spectral quality of the small form factor NIR sensor and its robustness is clearly sufficient for the construction and application of PLS models as well as PCA-based MSPC moisture models. The resulting high resolution moisture content signal was successfully used for endpoint detection and monitoring the mass transfer rate.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Process modeling and control applied to real-time monitoring of distillation processes by near-infrared spectroscopy

  • Rocha de Oliveira, Rodrigo
  • Pedroza, Rica
  • Sousa, Adriano O.
  • Lima, Kassio M. G.
  • Juan Capdevila, Anna de
A distillation device that acquires continuous and synchronized measurements of temperature, percentage of distilled fraction and NIR spectra has been designed for real-time monitoring of distillation processes. As a process model, synthetic commercial gasoline batches produced in Brazil, which contain mixtures of pure gasoline blended with ethanol have been analyzed. The information provided by this device, i.e., distillation curves and NIR spectra, has served as initial information for the proposal of new strategies of process modeling and multivariate statistical process control (MSPC). Process modeling based on PCA batch analysis provided global distillation trajectories, whereas multiset MCR-ALS analysis is proposed to obtain a component-wise characterization of the distillation evolution and distilled fractions. Distillation curves, NIR spectra or compressed NIR information under the form of PCA scores and MCR-ALS concentration profiles were tested as the seed information to build MSPC models. New on-line PCA-based MSPC approaches, some inspired on local rank exploratory methods for process analysis, are proposed and work as follows: a)MSPC based on individual process observation models, where multiple local PCA models are built considering the sole information in each observation point; b) Fixed Size Moving Window - MSPC, in which local PCA models are built considering a moving window of the current and few past observation points; and c) Evolving MSPC, where local PCA models are built with an increasing window of observations covering all points since the beginning of the process until the current observation. Performance of different approaches has been assessed in terms of sensitivity to fault detection and number of false alarms. The outcome of this work will be of general use to define strategies for on-line process monitoring and control and, in a more specific way, to improve quality control of petroleum-derived fuels and other substances submitted to automatic distillation processes monitored by NIRS.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

An ultra-compact particle size analyser using a CMOS image sensor and machine learning

  • Hussain, Rubaiya
  • Martinez Cordero, Pedro Antonio
  • Coll, T.
  • Pruneri, Valerio
Light scattering is a fundamental property that can be exploited to create essential devices such as particle analysers. The most common particle size analyser relies on measuring the angle-dependent diffracted light from a sample illuminated by a laser beam. Compared to other non-light-based counterparts, such a laser diffraction scheme offers precision, but it does so at the expense of size, complexity and cost. In this paper, we introduce the concept of a new particle size analyser in a collimated beam configuration using a consumer electronic camera and machine learning. The key novelty is a small form factor angular spatial filter that allows for the collection of light scattered by the particles up to predefined discrete angles. The filter is combined with a light-emitting diode and a complementary metal-oxide-semiconductor image sensor array to acquire angularly resolved scattering images. From these images, a machine learning model predicts the volume median diameter of the particles. To validate the proposed device, glass beads with diameters ranging from 13 to 125¿µm were measured in suspension at several concentrations. We were able to correct for multiple scattering effects and predict the particle size with mean absolute percentage errors of 5.09% and 2.5% for the cases without and with concentration as an input parameter, respectively. When only spherical particles were analysed, the former error was significantly reduced (0.72%). Given that it is compact (on the order of ten cm) and built with low-cost consumer electronics, the newly designed particle size analyser has significant potential for use outside a standard laboratory, for example, in online and in-line industrial process monitoring., This work is funded by the European Union’s Horizon 2020 research andinnovation programme under Grant Agreement No. 637232 (ProPAT project).R.H. and V.P. acknowledgefinancial support from the Spanish Ministry ofEconomy and Competitiveness through the‘Severo Ochoa’Programme forCentres of Excellence in R&D (SEV-2015-0522), from Fundació Privada Cellex,and from Generalitat de Catalunya through the CERCA programme, fromAGAUR 2017 SGR 1634. V.P. acknowledgesfinancial support from the SpanishMinistry of Economy and Competitiveness through the project OPTO-SCREEN(TEC2016-75080-R). This project has received funding from the EuropeanUnion’s Horizon 2020 research and innovation programme under the MarieSkłodowska-Curie grant agreement No 665884. The authors acknowledge theChemometrics group at the Universitat de Barcelona, especially Adrián GómezSánchez and Rodrigo Rocha de Oliveira, for their contribution in the helpfuldiscussions on measurement optimisation and background correction., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

An ultra-compact particle size analyser using a CMOS image sensor and machine learning

  • Hussain, Rubaiya
  • Martinez Cordero, Pedro Antonio
  • Coll, T.
  • Pruneri, Valerio
Light scattering is a fundamental property that can be exploited to create essential devices such as particle analysers. The most common particle size analyser relies on measuring the angle-dependent diffracted light from a sample illuminated by a laser beam. Compared to other non-light-based counterparts, such a laser diffraction scheme offers precision, but it does so at the expense of size, complexity and cost. In this paper, we introduce the concept of a new particle size analyser in a collimated beam configuration using a consumer electronic camera and machine learning. The key novelty is a small form factor angular spatial filter that allows for the collection of light scattered by the particles up to predefined discrete angles. The filter is combined with a light-emitting diode and a complementary metal-oxide-semiconductor image sensor array to acquire angularly resolved scattering images. From these images, a machine learning model predicts the volume median diameter of the particles. To validate the proposed device, glass beads with diameters ranging from 13 to 125¿µm were measured in suspension at several concentrations. We were able to correct for multiple scattering effects and predict the particle size with mean absolute percentage errors of 5.09% and 2.5% for the cases without and with concentration as an input parameter, respectively. When only spherical particles were analysed, the former error was significantly reduced (0.72%). Given that it is compact (on the order of ten cm) and built with low-cost consumer electronics, the newly designed particle size analyser has significant potential for use outside a standard laboratory, for example, in online and in-line industrial process monitoring., This work is funded by the European Union’s Horizon 2020 research andinnovation programme under Grant Agreement No. 637232 (ProPAT project).R.H. and V.P. acknowledgefinancial support from the Spanish Ministry ofEconomy and Competitiveness through the‘Severo Ochoa’Programme forCentres of Excellence in R&D (SEV-2015-0522), from Fundació Privada Cellex,and from Generalitat de Catalunya through the CERCA programme, fromAGAUR 2017 SGR 1634. V.P. acknowledgesfinancial support from the SpanishMinistry of Economy and Competitiveness through the project OPTO-SCREEN(TEC2016-75080-R). This project has received funding from the EuropeanUnion’s Horizon 2020 research and innovation programme under the MarieSkłodowska-Curie grant agreement No 665884. The authors acknowledge theChemometrics group at the Universitat de Barcelona, especially Adrián GómezSánchez and Rodrigo Rocha de Oliveira, for their contribution in the helpfuldiscussions on measurement optimisation and background correction., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Process modeling and control applied to real-time monitoring of distillation processes by near-infrared spectroscopy

  • Rocha de Oliveira, Rodrigo
  • Pedroza, Rica
  • Sousa, Adriano O.
  • Lima, Kassio M. G.
  • Juan Capdevila, Anna de
A distillation device that acquires continuous and synchronized measurements of temperature, percentage of distilled fraction and NIR spectra has been designed for real-time monitoring of distillation processes. As a process model, synthetic commercial gasoline batches produced in Brazil, which contain mixtures of pure gasoline blended with ethanol have been analyzed. The information provided by this device, i.e., distillation curves and NIR spectra, has served as initial information for the proposal of new strategies of process modeling and multivariate statistical process control (MSPC). Process modeling based on PCA batch analysis provided global distillation trajectories, whereas multiset MCR-ALS analysis is proposed to obtain a component-wise characterization of the distillation evolution and distilled fractions. Distillation curves, NIR spectra or compressed NIR information under the form of PCA scores and MCR-ALS concentration profiles were tested as the seed information to build MSPC models. New on-line PCA-based MSPC approaches, some inspired on local rank exploratory methods for process analysis, are proposed and work as follows: a)MSPC based on individual process observation models, where multiple local PCA models are built considering the sole information in each observation point; b) Fixed Size Moving Window - MSPC, in which local PCA models are built considering a moving window of the current and few past observation points; and c) Evolving MSPC, where local PCA models are built with an increasing window of observations covering all points since the beginning of the process until the current observation. Performance of different approaches has been assessed in terms of sensitivity to fault detection and number of false alarms. The outcome of this work will be of general use to define strategies for on-line process monitoring and control and, in a more specific way, to improve quality control of petroleum-derived fuels and other substances submitted to automatic distillation processes monitored by NIRS.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Process monitoring of moisture content and mass transfer rate in a fluidised bed with a low cost inline MEMS NIR sensor

  • Avila, Claudio R.
  • Ferré, Joan
  • Rocha de Oliveira, Rodrigo
  • Juan Capdevila, Anna de
  • Sinclair, Wayne E.
  • Mahdi, Faiz M.
  • Hassanpour, Ali
  • Hunter, Timothy N.
  • Bourne, Richard A.
  • Muller, Frans L.
Purpose The current trend for continuous drug product manufacturing requires new, affordable process analytical techniques (PAT) to ensure control of processing. This work evaluates whether property models based on spectral data from recent Fabry-Pérot Interferometer based NIR sensors can generate a high-resolution moisture signal suitable for process control. Methods Spectral data and offline moisture content were recorded for 14 fluid bed dryer batches of pharmaceutical granules. A PLS moisture model was constructed resulting in a high resolution moisture signal, used to demonstrate (i) endpoint determination and (ii) evaluation of mass transfer performance. Results The sensors appear robust with respect to vibration and ambient temperature changes, and the accuracy of water content predictions (±13%) is similar to those reported for high specification NIR sensors. Fusion of temperature and moisture content signal allowed monitoring of water transport rates in the fluidised bed and highlighted the importance water transport within the solid phase at low moisture levels. The NIR data was also successfully used with PCA-based MSPC models for endpoint detection. Conclusions The spectral quality of the small form factor NIR sensor and its robustness is clearly sufficient for the construction and application of PLS models as well as PCA-based MSPC moisture models. The resulting high resolution moisture content signal was successfully used for endpoint detection and monitoring the mass transfer rate.