Publication Artículo científico (JournalArticle)

Integrated assessment of sulfate-based AOPs for pharmaceutical active compound removal from wastewater

  • Sbardella, Luca
  • Velo-Gala, Inmaculada
  • Comas Matas, Joaquim
  • Morera Carbonell, Sadurní
  • Rodríguez-Roda Layret, Ignasi
  • Gernjak, Wolfgang
Advanced oxidation processes (AOPs) have been proposed as tertiary treatments for municipal WWTP effluents. UV-activated peroxydisulfate (PDS) and peroxymonosulfate (PMS) are viable technological alternatives for treating secondary WWTP effluent containing PhACs. This article examines the feasibility of applying UV/PDS and UV/PMS technologies at pilot scale, assessing their energy and cost requirements. In addition, life cycle assessment (LCA) impacts associated with the treatment of 1 m³ of wastewater with an effective average pharmaceutical active compounds (PhACs) removal of 80% has also been evaluated. Photolysis (UV) treatment alone was not capable of degrading PhACs to a sufficient extent in WWTP secondary effluent. The addition of 0.4 mmol of PDS or PMS, applying 416 mJ/cm2 of UV fluence, resulted in average removals of 84% and 85% for UV/PDS and UV/PMS, respectively. The electrical energy (kWh) required to degrade the mix of PhACs by one order of magnitude in 1 m³ of contaminated water was calculated as 0.9 kWh/m³/order and 0.8 kWh/m³/order 4 for UV/PDS and UV/PMS, respectively. However, the overall cost, including operation, materials and maintenance, of applying UV/PDS and UV/PMS, based on an average PhAC removal of 80%, was 0.088 €/m³ and 0.280 €/m³, respectively. From the sustainability assessment, the factors with the greatest environmental footprint for the UV/PDS process were chemical production (PDS: 52.9%, PMS: 85%) and electricity consumption (UV/PDS: 33.4%, UV/PMS: 11.2). Finally, the normalized environmental impact analysis showed that UV/PDS was associated with an environmental footprint three times lower than UV/PMS. The overall assessment revealed that UV/PDS is preferable to UV/PMS to remove PhACs in secondary effluents of municipal WWTPs having a lower economic and environmental impact, This work has been supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie - TreatRec ITN-EID project (grant number 642904) as well as from the Spanish Ministry of Science, Innovation and Universities, the State Agency of Investigation and EU FEDER program funding the following projects: CLEaN-TOUR (CTM 2017- 85385-C2-1-R) and INVEST (RTI 2018-097471-B-C21). WG, IRR and JC are also members of the Consolidated Research Group ICRA TECH - 2017 SGR 1318 funded by the Economy and Knowledge Department of the Catalan Government, 6
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Can source control of pharmaceuticals decrease the investment needs in urban wastewater infrastructure?

  • Corominas Tabares, Lluís
  • Gimeno Melià, Vicent Pau
  • Constantino, Carlos
  • Daldorph, Peter
  • Comas Matas, Joaquim
The source control of pharmaceuticals involves influencing the everyday consumption volume and compound choice. This paper evaluates how source control contributes to protecting the environmental health and decreasing the investment needs in urban wastewater infrastructure. Different levels of reduction in diclofenac consumption (as recommended by the European Medicines Agency) compensated by equivalent increases in naproxen consumption (a less environmentally harmful compound) are evaluated. The different loads of compounds are fed into a microcontaminant fate and transport model of the Llobregat river basin (Spain) to assess the investment needs in tertiary treatment to reach diclofenac and naproxen concentrations below environmental quality standards. The results show that, despite the implementation of source control measures, tertiary treatment upgrades are still required in every scenario evaluated. Even though source control of pharmaceuticals decreases the investment needs in urban wastewater infrastructure, apparent concentrations reductions (i.e. statistically significant differences relative to the reference situation) are only observed in drastic substitutions of diclofenac by naproxen (a reduction in the total diclofenac consumption by 73% and a corresponding increase in naproxen consumption). The results also show that Spain is on good track with regards to the substitution of diclofenac by naproxen (among the top 5 in Europe), and this paper shows how positive this substitution can be for the environment, The authors would like to acknowledge the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 642904 (TreatRec ITN- EID). The authors acknowledge INVEST (RTI2018-097471-B-C21) and CLEaN-TOUR (CTM2017-85385-C2-1-R) projects funded by the Spanish Ministry of Economy and Competitiveness. Lluís Corominas acknowledges funding from the Spanish Ministry of Economy and Competitiveness for the RYC-2013-14595 and its following I3. Additionally, we acknowledge the Economy and Knowledge Department of the Catalan Government (Consolidated Research Group 2017 SGR 1318). ICRA researchers thank funding from the CERCA program. The authors thank Berry Bergmann (Waterschap Drents Overijsselse Delta) for providing details on the pilot study conducted in the Netherlands for the replacement of diclofenac prescriptions in Meppel. The authors also thank Barbara Kasprzyk-Hordern (University of Bath), Kathryn Hickey and John Bagnall (Wessex Water) for a fruitful discussion on the optimization of WWTP upgrades combined with source control measures, and Vicenç Acuña and Wolfgang Gernjak for internal reviews
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Phosphorus recovery through biologically induced precipitation by partial nitritation-anammox granular biomass

  • Johansson, Sara
  • Ruscalleda Beylier, Maël
  • Colprim Galceran, Jesús
Recovery of phosphorus from waste streams reduces dependence on imported phosphate rock, which is increasingly contaminated with heavy metals and radioactive by-products. This study proves it is possible to recover phosphorus through biologically induced precipitation in granular partial nitritation-anammox sludge. Granules with high inorganic content were harvested from a lab-scale partial nitritation-anammox reactor fed with centrate. Inductively Coupled Plasma (ICP) Optical Emission Spectroscopy showed that the granules had a phosphate content of 36 wt% P2O5 and a Ca/P ratio close to that of hydroxyapatite. Crystalline hydroxyapatite was confirmed accordingly by X-ray diffraction. ICP further showed that the metals content complied with fertilizer regulations as well as with requirements from the phosphorus industry. The results are promising as they raise the possibility of recovering phosphorus from urban wastewater without the addition of chemicals, The work was financially supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 642904
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Potassium recovery from centrate: taking advantage of autotrophic nitrogen removal for multi-nutrient recovery

  • Johansson, Sara
  • Ruscalleda Beylier, Maël
  • Saerens, Bart
  • Colprim Galceran, Jesús
Potassium is a key macronutrient, but little attention has been paid to its recovery from waste streams. This study investigates simultaneous recovery of phosphorus and potassium in the form of potassium struvite (MgKPO 4 ·6H 2 O) from centrate after nitrogen removal by partial nitritation–anammox (PNA). Lab-scale batch experiments to assess the influence of pH, Mg:P ratio and temperature on nutrient removal were conducted on effluent from two PNA reactors fed with centrate from municipal wastewater treatment plants. RESULTS: pH had a strong impact on potassium removal, which increased up to pH 11. At this pH, a product containing 11.4% P, 3.51% N and 4.34% K was obtained. X-ray diffraction confirmed the presence of potassium struvite together with ammonium struvite (MgNH 4 PO 4 .6H 2 O). PNA reduced the alkalinity by 90%, which surpasses the performance of conventional CO 2 stripping by aeration. CONCLUSION: Coupling PNA with struvite precipitation allows for the recovery of N, P and K in a multi-nutrient product and may drastically reduce the need for alkali dosing for pH control, This work was financially supported by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No. 642904
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Advanced biological activated carbon filter for removing pharmaceutically active compounds from treated wastewater

  • Sbardella, Luca
  • Comas Matas, Joaquim
  • Fenu, Alessio
  • Rodríguez-Roda Layret, Ignasi
  • Weemaes, Marjoleine
Through their release of effluents, conventional wastewater treatment plants (WWTPs) represent a major pollution point sources for pharmaceutically active compounds (PhACs) in water bodies. The combination of a biological activated carbon (BAC) filter coupled with an ultrafiltration (UF) unit was evaluated as an advanced treatment for PhACs removal at pilot scale. The BAC-UF pilot plant was monitored for one year. The biological activity of the biofilm that developed on the granular activated carbon (GAC) particles and the contribution of this biofilm to the overall removal of PhACs were evaluated. Two different phases were observed during the long-term monitoring of PhACs removal. During the first 9200 bed volumes (BV; i.e., before GAC saturation), 89, 78, 83 and 79% of beta-blockers, psychiatric drugs, antibiotics and a mix of other therapeutic groups were removed, respectively. The second phase was characterized by deterioration of the overall performances during the period between 9200 and 13,800 BV. To quantify the respective contribution of adsorption and biodegradation, a lab-scale setup was operated for four months and highlighted the essential role played by GAC in biofiltration units. Physical adsorption was indeed the main removal mechanism. Nevertheless, a significant contribution due to biological activity was detected for some PhACs. The biofilm contributed to the removal of 22, 25, 30, 32 and 35% of ciprofloxacin, bezafibrate, ofloxacin, azithromycin and sulfamethoxazole, respectively, This work has been supported by the European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 642904 - TreatRec ITN-EID project
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Balancing environmental quality standards and infrastructure upgrade costs for the reduction of microcontaminant loads in rivers

  • Gimeno Melià, Vicent Pau
  • Severyns, Jo
  • Acuña, Vicenç
  • Comas Matas, Joaquim
  • Corominas Tabares, Lluís
The Authors Investments for upgrading wastewater treatment plants (WWTPs) with tertiary treatment to reduce microcontaminant loads in surface waters at a catchment scale can be daunting. These investments are highly sensitive to the selection of environmental quality standards (EQSs) for the target microcontaminants. Our hypothesis is that there is a balance between EQS selection and investment that needs to be considered in decision-making. We used a customized microcontaminant fate and transport model coupled to an optimization algorithm to validate this hypothesis in the Llobregat river basin and for the pharmaceutical compound diclofenac. The algorithm optimizes the number of WWTPs in this catchment requiring an upgrade to minimize the total amount of diclofenac that exceeds the EQS in every river section and the total cost. We simulated and optimized 40 scenarios representing a combination of 4 potential EQSs (10, 30, 50 and 100 ng L−1), 5 levels of uncertainty bounds in the predictions of river concentrations and 2 hydrological scenarios (average flows, flows annually exceeding 30% of the days; and environmental flows, flows annually exceeding 99% of the days). The results showthat there is a nonlinear relationship between the EQS and the required investment. The investment increases by 100% from an EQS of 100 ng L−1 to 10 ng L−1, significantly increasing (by 60%) from 30 to 10 ng L−1. Thus, establishing an EQS of 30 ng L−1 would balance environmental protection and costs. The selection of the hydrological conditions also plays a key role in the upgrade analysis because the costs for environmental flows are 50% higher than for average flows. Finally, we highlight that the investment in research would allow the reduction of uncertainties, hence allowing more qualified decisions to be made and a reduction in the WWTP upgrade costs (up to 4 €·household−1·year−1), The authors would like to acknowledge the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No 642904 (TreatRec ITN- EID). The authors thank Mirabella Mulder for providing details on the cost breakdown for ozonation and sand filtration. The authors also thank Rafael Marcè (ICRA), Carlos Constantino and Peter Daldorph (Atkins) for giving feedback on the article. Lluís Corominas acknowledges funding from the Spanish Ministry of Economy and Competitiveness for the RYC-2013-14595. Additionally, we acknowledge the Economy and Knowledge Department of the Catalan Government (Consolidated Research Group 2014 SGR 291)