Publication Artículo científico (JournalArticle)

In vitro hydrolytic degradation of polyester-based scaffolds under static and dynamic conditions in a customized perfusion bioreactor

  • Alamán-Díez, Pilar
  • García-Gareta, Elena
  • Napal, Pedro F.
  • Arruebo, Manuel
  • Pérez, María Ángeles
This article belongs to the Special Issue Advanced Functional Materials for Biomedicinal Applications., Creating biofunctional artificial scaffolds could potentially meet the demand of patients suffering from bone defects without having to rely on donors or autologous transplantation. Three-dimensional (3D) printing has emerged as a promising tool to fabricate, by computer design, biodegradable polymeric scaffolds with high precision and accuracy, using patient-specific anatomical data. Achieving controlled degradation profiles of 3D printed polymeric scaffolds is an essential feature to consider to match them with the tissue regeneration rate. Thus, achieving a thorough characterization of the biomaterial degradation kinetics in physiological conditions is needed. Here, 50:50 blends made of poly(ε-caprolactone)–Poly(D,L-lactic-co-glycolic acid (PCL-PLGA) were used to fabricate cylindrical scaffolds by 3D printing (⌀ 7 × 2 mm). Their hydrolytic degradation under static and dynamic conditions was characterized and quantified. For this purpose, we designed and in-house fabricated a customized bioreactor. Several techniques were used to characterize the degradation of the parent polymers: X-ray Photoelectron Spectroscopy (XPS), Gel Permeation Chromatography (GPC), Scanning Electron Microscopy (SEM), evaluation of the mechanical properties, weigh loss measurements as well as the monitoring of the degradation media pH. Our results showed that flow perfusion is critical in the degradation process of PCL-PLGA based scaffolds implying an accelerated hydrolysis compared to the ones studied under static conditions, and up to 4 weeks are needed to observe significant degradation in polyester scaffolds of this size and chemical composition. Our degradation study and characterization methodology are relevant for an accurate design and to tailor the physicochemical properties of polyester-based scaffolds for bone tissue engineering., This research was funded by ITN Marie Skłodowska-Curie Actions (722535); Gobierno de Aragón grant 2018-22; Spanish Ministry of Economy and Competitiveness (DPI2017-84780-C2-1-R) and Spanish Ministry of Economy and Competitiveness (PID2020-113819RB-I00)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Primary Human Osteoblasts Cultured in a 3D Microenvironment Create a Unique Representative Model of Their Differentiation Into Osteocytes

  • Nasello, Gabriele
  • Alamán-Díez, Pilar
  • Schiavi, Jessica
  • Pérez, María Ángeles
  • McNamara, Laoise
  • García-Aznar, José Manuel
{Microengineered systems provide an in vitro strategy to explore the variability of individual patient response to tissue engineering products, since they prefer the use of primary cell sources representing the phenotype variability. Traditional in vitro systems already showed that primary human osteoblasts embedded in a 3D fibrous collagen matrix differentiate into osteocytes under specific conditions. Here, we hypothesized that translating this environment to the organ-on-a-chip scale creates a minimal functional unit to recapitulate osteoblast maturation toward osteocytes and matrix mineralization. Primary human osteoblasts were seeded in a type I collagen hydrogel, to establish the role of lower (2.5 × 10<sup>5</sup> cells/ml) and higher (1 × 10<sup>6</sup> cells/ml) cell density on their differentiation into osteocytes. A custom semi-automatic image analysis software was used to extract quantitative data on cellular morphology from brightfield images. The results are showing that cells cultured at a high density increase dendrite length over time, stop proliferating, exhibit dendritic morphology, upregulate alkaline phosphatase (ALP) activity, and express the osteocyte marker dental matrix protein 1 (DMP1). On the contrary, cells cultured at lower density proliferate over time, do not upregulate ALP and express the osteoblast marker bone sialoprotein 2 (BSP2) at all timepoints. Our work reveals that microengineered systems create unique conditions to capture the major aspects of osteoblast differentiation into osteocytes with a limited number of cells. We propose that the microengineered approach is a functional strategy to create a patient-specific bone tissue model and investigate the individual osteogenic potential of the patient bone cells.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Integration of cortical thickness data in a statistical shape model of the scapula

  • Pitocchi, Jonathan
  • Wirix-Speetjens, Roel
  • van Lenthe, G. Harry
  • Pérez, María Ángeles
Knowledge about bone morphology and bone quality of the scapula throughout the population is fundamental in the design of shoulder implants. In particular, regions with the best bone stock (cortical bone) are taken into account when planning the supporting screws, aiming for an optimal fixation. As an alternative to manual measurements, statistical shape models (SSMs) have been commonly used to describe shape variability within a population. However, explicitly including cortical thickness information in an SSM of the scapula still remains a challenge. Therefore, the goal of this study is to combine scapular bone shape and cortex morphology in an SSM. First, a method to estimate cortical thickness, based on HU (Hounsfield Unit) profile analysis, was developed and validated. Then, based on the manual segmentations of 32 healthy scapulae, a statistical shape model including cortical information was created and evaluated. Generalization, specificity and compactness were calculated in order to assess the quality of the SSM. The average cortical thickness of the SSM was 2.0¿±¿0.63¿mm. Generalization, specificity and compactness performances confirmed that the combined SSM was able to capture the bone quality changes in the population. In this work we integrated information on the cortical thickness in an SSM for the scapula. From the results we conclude that this methodology is a valuable tool for automatically generating a large population of scapulae and deducing statistics on the cortex. Hence, this SSM can be useful to automate implant design and screw placement in shoulder arthroplasty.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Finite Element Analysis of Custom Shoulder Implants Provides Accurate Prediction of Initial Stability

  • Pitocchi, Jonathan
  • Wesseling, Mariska
  • van Lenthe, Gerrit H.
  • Pérez, María A.
Custom reverse shoulder implants represent a valuable solution for patients with large bone defects. Since each implant has unique patient-specific features, finite element (FE) analysis has the potential to guide the design process by virtually comparing the stability of multiple configurations without the need of a mechanical test. The aim of this study was to develop an automated virtual bench test to evaluate the initial stability of custom shoulder implants during the design phase, by simulating a fixation experiment as defined by ASTM F2028-14. Three-dimensional (3D) FE models were generated to simulate the stability test and the predictions were compared to experimental measurements. Good agreement was found between the baseplate displacement measured experimentally and determined from the FE analysis (Spearman’s rank test, p < 0.05, correlation coefficient ¿s = 0.81). Interface micromotion analysis predicted good initial fixation (micromotion <150 µm, commonly used as bone ingrowth threshold). In conclusion, the finite element model presented in this study was able to replicate the mechanical condition of a standard test for a custom shoulder implants.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automated muscle elongation measurement during reverse shoulder arthroplasty planning

  • Pitocchi, Jonathan
  • Plessers, Katrien
  • Wirix-Speetjens, Roel
  • Debeer, Philippe
  • van Lenthe, G. Harry
  • Jonkers, Ilse
  • Pérez Ansón, María de los Ángeles
  • Vander Sloten, Jos
Background: Adequate deltoid and rotator cuff elongation in reverse shoulder arthroplasty is crucial to maximize postoperative func- tional outcomes and to avoid complications. Measurements of deltoid and rotator cuff elongation during preoperative planning can sup- port surgeons in selecting a suitable implant design and position. Therefore, this study presented and evaluated a fully automated method for measuring deltoid and rotator cuff elongation. Methods: Complete scapular and humeral models were extracted from computed tomography scans of 40 subjects. First, a statistical shape model of the complete humerus was created and evaluated to identify the muscle attachment points. Next, a muscle wrapping algorithm was developed to identify the muscle paths and to compute muscle lengths and elongations after reverse shoulder arthroplasty implantation. The accuracy of the muscle attachment points and the muscle elongation measurements was evaluated for the 40 subjects by use of both complete and artificially created partial humeral models. Additionally, the muscle elongation measurements were evaluated for a set of 50 arthritic shoul- der joints. Finally, a sensitivity analysis was performed to evaluate the impact of implant positioning on deltoid and rotator cuff elongation. Results: Forthecompletehumeralmodels,allmuscleattachmentpointswereidentifiedwithamedianerror<3.5mm.Forthepartialhumeral models, the errors on the deltoid attachment point largely increased. Furthermore, all muscle elongation measurements showed an error < 1 mm for 75% of the subjects for both the complete and partial humeral models. For the arthritic shoulder joints, the errors on the muscle elongation mea- surements were <2 mm for 75% of the subjects. Finally, the sensitivity analysis showed that muscle elongations were affected by implant positioning. Discussion: This study presents an automated method for accurately measuring muscle elongations during preoperative planning of shoulder arthroplasty. The results show that the accuracy in measuring muscle elongations is higher than the accuracy in indicating the muscle attachment points. Hence, muscle elongation measurements are insensitive to the observed errors on the muscle attachment points. Related to this finding, muscle elongations can be accurately measured for both a complete humeral model and a partial humeral model. Because the presented method also showed accurate results for arthritic shoulder joints, it can be used during preoperative shoulder arthroplasty planning, in which typically only the proximal humerus is present in the scan and in which bone arthropathy can be present. As the muscle elongations are sensitive to implant positioning, surgeons can use the muscle elongation measurements to refine their surgical plan.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Mechano-driven regeneration predicts response variations in large animal model based on scaffold implantation site and individual mechano-sensitivity

  • Nasello, Gabriele
  • Vautrin, Antoine
  • Pitocchi, Jonathan
  • Wesseling, Mariska
  • Kuiper, Jan Herman
  • Pérez Ansón, María de los Ángeles
  • García Aznar, José Manuel
It is well founded that the mechanical environment may regulate bone regeneration in orthopedic applications. The purpose of this study is to investigate the mechanical contributions of the scaffold and the host to bone regeneration, in terms of subject specificity, implantation site and sensitivity to the mechanical environment. Using a computational approach to model mechano-driven regeneration, bone ingrowth in porous titanium scaffolds was simulated in the distal femur and proximal tibia of three goats and compared to experimental results. The results showed that bone ingrowth shifted from a homogeneous distribution pattern, when scaffolds were in contact with trabecular bone (max local ingrowth 12.47%), to a localized bone ingrowth when scaffolds were implanted in a diaphyseal location (max local ingrowth 20.64%). The bone formation dynamics revealed an apposition rate of 0.37±0.28%/day in the first three weeks after implantation, followed by limited increase in bone ingrowth until the end of the experiment (12 weeks). According to in vivo data, we identified one animal whose sensitivity to mechanical stimulation was higher than the other two. Moreover, we found that the stimulus initiating bone formation was consistently higher in the femur than in the tibia for all the individuals. Overall, the dependence of the osteogenic response on the host biomechanics means that, from a mechanical perspective, the regenerative potential depends on both the scaffold and the host environment. Therefore, this work provides insights on how the mechanical conditions of both the recipient and the scaffold contribute to meet patient and location-specific characteristics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Standard Cruciate-Retaining Total Knee Arthroplasty Implants can Reproduce Native Kinematics

  • Dejtiar, David Leandro
  • Bartsoen, Laura
  • Wesseling, Mariska
  • Wirix-Speetjens, Roel
  • Vander Sloten, Jos
  • Perez, Maria Angeles
Total knee arthroplasty (TKA) is a common procedure that has become the standard of treatment for severe cases of knee osteoarthritis. Biomechanics and quality of movement similar to healthy were found to improve patient-reported outcomes. In this study, an evaluated musculoskeletal model predicted ligament, contact and muscle forces together with secondary tibiofemoral kinematics. An artificial neural network applied to the musculoskeletal model searched for the optimal implant position in a given range that will minimize the root-mean-square-error (RMSE) between post- TKA and native experimental tibiofemoral kinematics during a squat. We found that, using a cruciate-retaining implant, native kinematics could be accurately reproduced (average RMSE 1.47 mm (± 0.89 mm) for translations and 2.89° (± 2.83°) for rotations between native and optimal TKA alignment). The required implant positions changes maximally 2.96 mm and 2.40o. This suggests that when using pre- operative planning, off-the-shelf CR implants allow for reproducing native knee kinematics post-operatively.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Automatic muscle elongation measurement during shoulder arthroplasty planning

  • Pitocchi, J.
  • Plessers, K.
  • Wesseling, M.
  • Van Lenthe, G.H.
  • Perez, M.A.
Adequate deltoid and rotator cuff lengthening in total shoulder arthroplasty (TSA) is crucial to maximize the postoperative functional outcome and to avoid complications (La¨dermann et al., 2014). Hence surgeons and patients could benefit from including muscle length information in preoperative planning software. Although different methods have been introduced to automatically indicate patient-specific muscle attachment and wrapping points (Kaptein & van der Helm, 2004; Marra et al., 2015), the definition of a fast and accurate workflow is still a challenge, due to the large variability in bone shapes. Statistical shape modelling (SSM) has recently been used to automatically indicate landmark on target bones (Plessers et al., 2018). This method is less dependent on shape variability and could overcome the aforementioned limitation in accuracy. Therefore, the goal of this study is to develop and evaluate the accuracy of a novel automatic method for measuring deltoid and rotator cuff elongation during preoperative planning of shoulder arthroplasty, based on a statistical shape modelling approach.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Designing Hydrogel-Based Bone-On-Chips for Personalized Medicine

  • Nasello , Gabriele
  • Cóndor , Mar
  • Vaughan , Ted
  • Schiavi , Jessica
The recent development of bone-on-chips (BOCs) holds the main advantage of requiring a low quantity of cells and material, compared to traditional In Vitro models. By incorporating hydrogels within BOCs, the culture system moved to a three dimensional culture environment for cells which is more representative of bone tissue matrix and function. The fundamental components of hydrogel-based BOCs, namely the cellular sources, the hydrogel and the culture chamber, have been tuned to mimic the hematopoietic niche in the bone aspirate marrow, cancer bone metastasis and osteo/chondrogenic differentiation. In this review, we examine the entire process of developing hydrogel-based BOCs to model In Vitro a patient specific situation. First, we provide bone biological understanding for BOCs design and then how hydrogel structural and mechanical properties can be tuned to meet those requirements. This is followed by a review on hydrogel-based BOCs, developed in the last 10 years, in terms of culture chamber design, hydrogel and cell source used. Finally, we provide guidelines for the definition of personalized pathological and physiological bone microenvironments. This review covers the information on bone, hydrogel and BOC that are required to develop personalized therapies for bone disease, by recreating clinically relevant scenarii in miniaturized devices
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Multiscale modeling of bone tissue Mechanobiology

  • García-Aznar, José Manuel
  • Nasello, Gabriele
  • Hervas-Raluy, Silvia
  • Pérez Ansón, María de los Ángeles
  • Gómez-Benito, María José
Mechanical environment has a crucial role in our organism at the different levels, ranging from cells to tissues and our own organs. This regulatory role is especially relevant for bones, given their importance as load-transmitting elements that allow the movement of our body as well as the protection of vital organs from load impacts. Therefore bone, as living tissue, is continuously adapting its properties, shape and repairing itself, being the mechanical loads one of the main regulatory stimuli that modulate this adaptive behavior. Here we review some key results of bone mechanobiology from computational models, describing the effect that changes associated to the mechanical environment induce in bone response, implant design and scaffold-driven bone regeneration.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Time-dependent in silico modelling of orthognathic surgery to support the design of biodegradable bone plates

  • Vautrin, Antoine
  • Wesseling, Mariska
  • Wirix-Speetjens, Roel
  • Gómez Benito, María José
Orthognathic surgery is performed to realign the jaws of a patient through several osteotomies. The state-of- the-art bone plates used to maintain the bone fragments in place are made of titanium. The presence of these non-degradable plates can have unwanted side effects on the long term (e.g. higher infection risk) if they are not removed. Using a biodegradable material such as magnesium may be a possible solution to this problem. However, biodegradation leads to a decrease of mechanical strength, therefore a time-dependent computational approach can help to evaluate the performance of such plates. In the present work, a computational framework has been developed to include biodegradation and bone healing algorithms in a finite element model. It includes bone plates and the mandible, which are submitted to masticatory loads during the early healing period (two months following the surgery). Two different bone plate designs with different stiffnesses have been tested. The stiff design exhibited good mechanical stability, with maximum Von Mises stress being less than 40% of the yield strength throughout the simulation. The flexible design shows high stresses when the bone healing has not started in the fracture gaps, indicating possible failure of the plate. However, this design leads to a higher bone healing quality after two months, as more cartilage is formed due to higher strains exerted in fracture gaps. We therefore conclude that in silico modelling can support tuning of the design parameters to ensure mechanical stability and while promoting bone healing.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

In vitro hydrolytic degradation of polyester-based scaffolds under static and dynamic conditions in a customized perfusion bioreactor

  • Alamán Díez, P.
  • García Gareta, E.
  • Napal, P. F.
  • Arruebo, M.
  • Pérez, M. Á.
Creating biofunctional artificial scaffolds could potentially meet the demand of patients suffering from bone defects without having to rely on donors or autologous transplantation. Three-dimensional (3D) printing has emerged as a promising tool to fabricate, by computer design, biodegradable polymeric scaffolds with high precision and accuracy, using patient-specific anatomical data. Achieving controlled degradation profiles of 3D printed polymeric scaffolds is an essential feature to consider to match them with the tissue regeneration rate. Thus, achieving a thorough characterization of the biomaterial degradation kinetics in physiological conditions is needed. Here, 50:50 blends made of poly(e-caprolactone)–Poly(D, L-lactic-co-glycolic acid (PCL-PLGA) were used to fabricate cylindrical scaffolds by 3D printing (Ø 7 × 2 mm). Their hydrolytic degradation under static and dynamic conditions was characterized and quantified. For this purpose, we designed and in-house fabricated a customized bioreactor. Several techniques were used to characterize the degradation of the parent polymers: X-ray Photoelectron Spectroscopy (XPS), Gel Permeation Chro-matography (GPC), Scanning Electron Microscopy (SEM), evaluation of the mechanical properties, weigh loss measurements as well as the monitoring of the degradation media pH. Our results showed that flow perfusion is critical in the degradation process of PCL-PLGA based scaffolds implying an accelerated hydrolysis compared to the ones studied under static conditions, and up to 4 weeks are needed to observe significant degradation in polyester scaffolds of this size and chemical composition. Our degradation study and characterization methodology are relevant for an accurate design and to tailor the physicochemical properties of polyester-based scaffolds for bone tissue engineering.