Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Fast 0.5 T Prepolarizer Module for Preclinical Magnetic Resonance Imaging

  • Rigla, J. P.
  • Gramage, Carlos
  • González-Hernández, José Manuel
  • Sanchez-Andres, Juan V.
  • Galve, Fernando
  • Grau-Ruiz, Daniel
  • Pellicer, Rubén
  • Rios, Alfonso
  • Alonso, Joseba
  • Borreguero-Morata, José
  • Pallás-Lodeiro, Eduardo
  • Bosch-Esteve, Rubén|||0000-0002-7316-7819
  • Algarín-Guisado, José Miguel|||0000-0003-2644-7225
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] We present a magnet and high power electronics for Prepolarized Magnetic Resonance Imaging (PMRI) in a home-made, special-purpose preclinical system designed for simultaneous visualization of hard and soft biological tissues. The sensitivity of MRI systems grows with field strength, but so do their costs. PMRI can boost the signal-to-noise ratio (SNR) in affordable low-field scanners by means of a long and strong magnetic pulse. However, this must be rapidly switched off prior to the imaging pulse sequence, in timescales shorter than the spin relaxation (or T1) time of the sample. We have operated our prepolarizer at up to 0.5 T and demonstrated enhanced magnetization, image SNR and tissue contrast with PMRI of tap water, an ex vivo mouse brain and food samples. These have T1 times ranging from hundreds of milli-seconds to single seconds, while the preliminary high-power electronics setup employed in this work can switch off the prepolarization field in tens of milli-seconds. In order to make this system suitable for solid-state matter and hard tissues, which feature T1 times as short as 10 ms, we are developing new electronics which can cut switching times to ~ 300 ¿s. This does not require changes in the prepolarizer module, opening the door to the first experimental demonstration of PMRI on hard biological tissues., This work was supported in part by the European Commission under Grant 737180 (FET-Open: HistoMRI), in part by the Ministerio de Ciencia e Innovación of Spain for Research under Grant PID2019-111436RB-C21, and in part by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) of the Comunitat Valenciana 2014¿2020 under Grant IDIFEDER/2018/022. The work of José M. González was supported by the Innodocto Program of the Agencia Valenciana de la Innovación under Grant INNTA3/2020/22. The work of Juan V. Sanchez-Andres was supported by the Universitat Jaume I - Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (UJISABIO) under Grant 21I044.01/1
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Magneto-stimulation limits in medical imaging applications with rapid field dynamics

  • Grau-Ruiz, Daniel
  • Rigla, Juan P.
  • López-Comazzi, Guillermo
  • Galve, Fernando
  • Díaz-Caballero, Elena
  • Gramage, Carlos
  • González Hernández, José Manuel
  • Pellicer, Rubén
  • Rios, Alfonso
  • Alonso, Joseba
  • Pallás-Lodeiro, Eduardo
  • Algarín-Guisado, José Miguel|||0000-0003-2644-7225
  • Borreguero-Morata, José
  • Bosch-Esteve, Rubén|||0000-0002-7316-7819
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] Objective. The goal of this work is to extend previous peripheral nerve stimulation (PNS) studies to scenarios relevant to magnetic particle imaging (MPI) and low-field magnetic resonance imaging (MRI), where field dynamics can evolve at kilo-hertz frequencies. Approach. We have constructed an apparatus for PNS threshold determination on a subject's limb, capable of narrow and broad-band magnetic stimulation with pulse characteristic times down to 40 mu s. Main result. From a first set of measurements on 51 volunteers, we conclude that the PNS dependence on pulse frequency/rise-time is compatible with traditional stimulation models where nervous responses are characterized by a rheobase and a chronaxie. Additionally, we have extended pulse length studies to these fast timescales and confirm thresholds increase significantly as trains transition from tens to a few pulses. We also look at the influence of field spatial distribution on PNS effects, and find that thresholds are higher in an approximately linearly inhomogeneous field (relevant to MRI) than in a rather homogeneous distribution (as in MPI). Significance. PNS constrains the clinical performance of MRI and MPI systems. Extensive magneto-stimulation studies have been carried out recently in the field of MPI, where typical operation frequencies range from single to tens of kilo-hertz. However, PNS literature is scarce for MRI in this fast regime, relevant to small (low inductance) dedicated MRI setups, and where the resonant character of MPI coils prevents studies of broad-band stimulation pulses. This work advances in this direction., We thank all 51 anonymous volunteers for their participation in these studies, and Manuel Murbach for discussions. This work was supported by the European Commission under grant 737 180 (FET-Open: HistoMRI) and Ministerio de Ciencia e Innovacion of Spain for research grant PID2019-111436RB-C21. Action co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) of the Comunitat Valenciana 2014-2020 (IDIFEDER/2018/022)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Simultaneous imaging of hard and soft biological tissues in a low-field dental MRI scanner

  • Algarín-Guisado, José Miguel|||0000-0003-2644-7225
  • Borreguero-Morata, José
  • Bosch-Esteve, Rubén|||0000-0002-7316-7819
  • Pallás-Lodeiro, Eduardo
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Díaz-Caballero, Elena
  • Galve, Fernando
  • Grau-Ruiz, Daniel
  • Rigla, Juan P.
  • González-Hernández, José Manuel
  • Corberán, Miguel
  • Gramage, Carlos
  • Aja-Fernández, Santiago
  • Ríos, Alfonso
  • Alonso, Joseba
[EN] Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some medical applications, such as dentistry, continues to be limited. Here, we present three-dimensional reconstructions of ex-vivo human teeth, as well as a rabbit head and part of a cow femur, all obtained at a field strength of 260 mT. These images are the first featuring soft and hard tissues simultaneously at sub-Tesla fields, and they have been acquired in a home-made, special-purpose, pre-medical MRI scanner designed with the goal of demonstrating dental imaging at low field settings. We encode spatial information with two pulse sequences: Pointwise-Encoding Time reduction with Radial Acquisition and a new sequence we have called Double Radial Non-Stop Spin Echo, which we find to perform better than the former. For image reconstruction we employ Algebraic Reconstruction Techniques (ART) as well as standard Fourier methods. An analysis of the resulting images shows that ART reconstructions exhibit a higher signal-to-noise ratio with a more homogeneous noise distribution., We thank anonymous donors for their tooth samples, Andrew Webb and Thomas O'Reilly (LUMC) for discussions on hardware and pulse sequences, and Antonio Tristan (UVa) for information on reconstruction techniques. This work was supported by the European Commission under Grants 737180 (FET-OPEN: HISTO-MRI) and 481 (ATTRACT: DentMRI). Action co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) of the Comunitat Valenciana 2014-2020 (IDIFEDER/2018/022). Santiago Aja-Fernandez acknowledges Ministerio de Ciencia e Innovacion of Spain for research grant RTI2018-094569-B-I00.