Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Adapted composite two-region line source methods for evaluation of borehole heat exchangers with advanced materials

  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Javadi, Hossein|||0000-0002-2059-7145
  • Mateo Pla, Miguel Ángel|||0000-0002-8059-6996
  • Armengot-Carbó, B.|||0000-0001-7424-2975
[EN] The results of a large number of Thermal Response Tests (TRTs) performed on four different borehole heat exchangers (BHEs) were analyzed to explore the effect of the novel grouting and plastic pipe materials developed in a previous project on their thermal performance. For this purpose, two versions of the composite two-region line source approach have been adapted for its use for evaluating BHEs in practical situations, allowing us to obtain more comprehensive and consistent information on key thermal parameters of ground and fillers. We develop a scheme that combines the composite two-region model with unsteady TRT injection data to avoid some shortcomings that have appeared in previous implementations of this approach. Our new method enables us to obtain parameters otherwise difficult to obtain, such as the diffusivities, heat capacities, and conductivities of ground and grout. In comparison with standard line source based analysis, it allows to improve and enrich TRT execution, with a reduction in the test time required, lower uncertainties of the parameters obtained, and a deeper understanding of the thermal properties of the grout, ground, and borehole heat exchanger as all estimates are correlated to actual physical, mensurable soil and ground properties, which allows independent critical revision and check against alternative estimation methods.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Tesis doctoral (DoctoralThesis)

Optimización teórico-experimental de sondas de calor para intercambio geotérmico (SGE) según condiciones hidrogeológicas, características geométricas y propiedades de sus materiales

  • Badenes Badenes, Borja|||0000-0002-3469-9265
[ES] Uno de los mayores retos para el mercado de bombas de calor geotérmicas es el alto coste asociado a la perforación de los intercambiadores de calor geotérmicos. Conseguir unos intercambiadores de calor geotérmicos más eficientes reduciría dicho coste, ya que sería necesaria una menor longitud de intercambiador para obtener las mismas temperaturas de trabajo en él (misma eficiencia de la bomba de calor). La eficiencia térmica de un intercambiador de calor geotérmico está caracterizada por su resistencia térmica. Dicha resistencia térmica depende de una serie de elementos entre los que se encuentran: propiedades y caudal del fluido que recorre el intercambiador de calor, diámetro de la perforación geotérmica, geometría y materiales de la tubería del intercambiador de calor y las propiedades del material de relleno de la perforación (grouting). Cuanto mayor sea la resistencia térmica del intercambiador de calor, menor será el calor transferido entre el fluido caloportador y el terreno, traduciéndose en una necesidad mayor de longitud de intercambiador enterrado. Por lo tanto, es necesario una reducción de este parámetro al mínimo posible. En consecuencia, el objetivo principal de esta tesis doctoral consiste en, a partir de un modelo analítico comprensivo de cuantificación del impacto de los parámetros anteriores, realizar un estudio detallado para analizar su influencia combinada en la resistencia térmica del intercambiador geotérmico, pero también examinando dicho efecto en otros planos, como costes económicos de ejecución del intercambiador y de explotación (consumo eléctrico de la bomba de calor y costes de bombeo asociados)., [CA] Un dels majors reptes per al mercat de bombes de calor geotèrmiques és l'alt cost associat a la perforació dels bescanviadors de calor geotèrmics. Aconseguir uns bescanviadors de calor geotèrmics més eficients reduiria aquest cost, ja que seria necessària una menor longitud de bescanviador per a obtenir les mateixes temperatures de treball en ell (mateixa eficiència de la bomba de calor). L'eficiència tèrmica d'un bescanviador de calor geotèrmic està caracteritzada per la seva resistència tèrmica. Aquesta resistència tèrmica depèn d'una sèrie d'elements entre els quals es troben: propietats i cabal del fluid que recorre el bescanviador de calor, diàmetre de la perforació geotèrmica, geometria i materials de la canonada del bescanviador de calor i les propietats del material de farciment de la perforació (grouting). Com més gran sigui la resistència tèrmica del bescanviador de calor, menor serà la calor transferida entre el fluid termòfor i el terreny, traduint-se en una necessitat major de longitud de bescanviador enterrat. Per tant, és necessari una reducció d'aquest paràmetre al mínim possible. En conseqüència, l'objectiu principal d'aquesta Tesi Doctoral consisteix en, a partir d'un model analític comprensiu de quantificació de l'impacte dels paràmetres anteriors, realitzar un estudi detallat per a analitzar la seva influència combinada en la resistència tèrmica del bescanviador geotèrmic, però també examinant aquest efecte en altres plans, com a costos econòmics d'execució del bescanviador i d'explotació (consum elèctric de la bomba de calor i costos de bombament)., [EN] One of the biggest challenges for the ground source heat pump market is the high cost associated with drilling geothermal borehole heat exchangers. Achieving more efficient geothermal heat exchangers would reduce this cost, since a shorter exchanger length would be required to obtain the same working temperatures in it (same efficiency of the heat pump). The thermal efficiency of a geothermal heat exchanger is characterized by its borehole thermal resistance. This borehole thermal resistance depends on a number of parameters, mainly: properties and flow rate of the working fluid that flows through the borehole heat exchanger, diameter of the geothermal borehole, geometry and materials of the heat exchanger pipe and the properties of the borehole grouting material. The higher thermal resistance of the heat exchanger, the less heat is transferred between the heat carrier fluid and the ground, resulting in an increased requirement for the length of the buried heat exchanger. Consequently, it is essential to reduce this parameter to the minimum possible. Therefore, the main objective of this Ph. Doctoral Thesis is to carry out, based on a comprehensive analytical model of quantification of the impact of the above mentioned parameters, a detailed study to analyze their combined influence on the thermal resistance of the geothermal borehole, but also exploring this effect in other less researched areas, such as economic costs of running the exchanger and operating it (electricity consumption of the heat pump and associated pumping costs)., This research has received funding from the European Union’s Horizon 2020 Research and Innovation program under grant agreement No [657982], [727583] and [792355].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Numerical Study on the Thermal Performance of a Single U-Tube Borehole Heat Exchanger Using Nano-Enhanced Phase Change Materials

  • Javadi, Hossein|||0000-0002-2059-7145
  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Mousavi Ajarostaghi, Seyed Soheil
[EN] To investigate the impacts of using nano-enhanced phase change materials on the thermal performance of a borehole heat exchanger in the summer season, a three-dimensional numerical model of a borehole heat exchanger is created in the present work. Seven nanoparticles including Cu, CuO, Al2O3, TiO2, SiO2, multi-wall carbon nanotube, and graphene are added to the Paraffin. Considering the highest melting rate and lowest outlet temperature, the selected nano-enhanced phase change material is evaluated in terms of volume fraction (0.05, 0.10, 0.15, 0.20) and then the shape (sphere, brick, cylinder, platelet, blade) of its nanoparticles. Based on the results, the Paraffin containing Cu and SiO2 nanoparticles are found to be the best and worst ones in thermal performance improvement, respectively. Moreover, it is indicated that the increase in the volume fraction of Cu nanoparticles could enhance markedly the melting rate, being 0.20 the most favorable value which increased up to 55% the thermal conductivity of the nano-enhanced phase change material compared to the pure phase change material. Furthermore, the blade shape is by far the most appropriate shape of the Cu nanoparticles by considering about 85% melting of the nano-enhanced phase change materia, This research work has been supported financially by the European project GEOCOND (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 727583) and by the European project GEO4CIVHIC (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 792355).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of a method for the sustainable planning and management of ground source heat pump systems in an urban environment, considering the effects of reciprocal thermal interference

  • Belliardi, Marco
  • Soma, Linda
  • Perego, Rodolfo
  • Pera, Sebastian
  • Di Sipio, Eloisa
  • Zarrella, Angelo
  • Carnieletto, Laura
  • Galgaro, Antonio
  • Pasquali, Riccardo
  • Bertermann, David
  • Sanner, Burkhard
  • Badenes Badenes, Borja|||0000-0002-3469-9265
[EN] The ¿Most Easy, Efficient and Low Cost Geothermal Systems for Retrofitting Civil and Historical Buildings¿ (GEO4CIVHIC) project aims to accelerate the deployment of shallow geothermal systems for heating and cooling purposes when retrofitting existing and historical buildings. Analyzing the implementation process of borehole heat exchangers (BHEs), allows the understanding of how to promote the long-term sustainability of shallow geothermal energy systems. The thermal interference between BHE systems represents a problem, especially due to the increasing deployment of this technology and its spread in densely built-up areas. The main goal of this paper is to propose a conceptual model and to apply this to different case studies. The methodology includes phases to adopt an integrated approach for preventing long term thermal interference in neighbouring borehole heat exchangers, by providing management strategies and technical suggestions for design and operation. The method developed follows the following steps: 1) literature review to determine what are the main drivers for thermal interference between shallow geothermal systems, in the context of the GEO4CIVHIC project case study sites; 2) to create a conceptual model to limit thermal interference at both design and operational phases; 3) to apply the developed method to real and virtual case studies in countries with different regulatory frameworks and to test its main strengths and weaknesses. The application of this conceptual model to specific case studies provides evidence of critical planning and operational characteristics of GSHP systems and allows the identification of measures to mitigate impacts of thermal interference to be identified., This research was financially supported by the European Union¿s Horizon 2020 research and innovation programme under the grant agreement No 792355 (Most Easy, Efficient and Low Cost Geothermal Systems for Retrofitting Civil and Historical Buildings [GEO4CIVHIC]).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Case Study of Thermal Evolution in the Vicinity of Geothermal Probes Following a Distributed TRT Method

  • Schwarz, Hans
  • Wagner, Jan
  • Cuevas, José Manuel
  • Bertermann, David
  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
[EN] To meet the stated climate change targets and to ensure the capability of meeting the current and future energy demands, there is an urgent need to develop renewable energy sources, such as geothermal systems. If geothermal systems are to be cost-efficient and are to enjoy public confidence, it is essential that they are designed and installed in accordance with the prevailing site-specific conditions. A thorough understanding of the thermal behaviour of the surrounding ground is, therefore, critical. In this work, we investigated temperature and its evolution in the vicinity of a shallow geothermal helix-shaped borehole heat exchanger (BHE). To measure the temperature close to the actual geothermal system, an additional U-tube probe was installed at the edge of the same borehole. A thermal load was then applied to the BHE, and the temperature was detected in the nearby U-tube. The temperature measurements were made with a GEOSniff monitoring device. To understand these localised temperature measurements in the context of the Valencia test site, ERT measurements were also performed. The GEOSniff device permits measurements to be made with very high depth resolution, which allows the thermal properties of the surrounding ground to be derived precisely, thus, enabling the identification of the different textural domains., This research work has been supported financially by the European Cheap-GSHPs Project (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 657982) and by the European GEO4CIVHIC Project (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 792355).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Use of advanced pipe and grout materials in an experimental Single-U BHE: Installation procedure assessment and thermal properties comparison using C2RLSM

  • Mateo Pla, Miguel Ángel|||0000-0002-8059-6996
  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Armengot-Carbó, B.|||0000-0001-7424-2975
  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
  • Cuevas-Castell, José Manuel
  • Sanner, Burkhard
[EN] The performance of a Shallow Geothermal Energy System (SGES) is significantly influenced by the materials that conform its borehole heat exchangers (BHEs). Traditionally, plastic pipes and cement-based grouts, originally developed for other applications, have been employed in these systems due to their accessibility and ease of installation. However, these materials impose certain efficiency limitations. This article reports the installation process of two BHEs using new grout and pipe materials designed to increase their suitability for SGE systems. The validation process included material characterization tests during installation. Once installed, the new boreholes were compared with a reference BHE (based on standard pipes and grout) by performing standard Thermal Response Tests (TRT) on each borehole at the same thermal power injection rate. The Composite 2 Region Line Source Model (C2RLSM) has been used to analyse the TRT data. C2RLSM gives plausible estimates on the thermal properties of the ground and the BHE, including a comparable borehole thermal resistance R*b. We report improved R*b from 0.15 mK/W for standard materials to 0.1 mK/W for new materials. The use of these materials could imply CAPEX reductions of more than 20% in common BHE., This work has received funding from the European Union s Horizon 2020 Research and Innovation program under grants agreement No [792355] and No [727583].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Impact of Employing Hybrid Nanofluids as Heat Carrier Fluid on the Thermal Performance of a Borehole Heat Exchanger

  • Javadi, Hossein|||0000-0002-2059-7145
  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Ajarostaghi, Seyed Soheil Mousavi
[EN] In this numerical study, 4 types of hybrid nanofluid, including Ag-MgO/water, TiO2-Cu/water, Al2O3-CuO/water, and Fe3O4-multi-wall carbon nanotube/water, have been considered potential working fluid in a single U-tube borehole heat exchanger. The selected hybrid nanofluid is then analyzed by changing the volume fraction and the Reynolds number. Based on the numerical results, Ag-MgO/water hybrid nanofluid is chosen as the most favorable heat carrier fluid, among others, considering its superior effectiveness, minor pressure drop, and appropriate thermal resistance compared to the pure water. Moreover, it was indicated that all cases of Ag-MgO/water hybrid nanofluid at various volume fractions (from 0.05 to 0.20) and Reynolds numbers (from 3200 to 6200) could achieve better effectiveness and lower thermal resistances, but higher pressure drops compared to the corresponding cases of pure water. Nevertheless, all the evaluated hybrid nanofluids present lower coefficient of performance (COP)-improvement than unity which means that applying them as working fluid is not economically viable because of having higher pressure drop than the heat transfer enhancement., This research work has been supported financially by the European project GEOCOND (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 727583) and by the European project GEO4CIVHIC (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 792355).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

New trilobular geometry using advanced materials for experimentally validated enhanced heat transfer in shallow geothermal applications

  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Mateo Pla, Miguel Ángel|||0000-0002-8059-6996
  • Armengot-Carbó, B.|||0000-0001-7424-2975
  • Javadi, Hossein|||0000-0002-2059-7145
[EN] The Adapted Conductivity Trilobular (ACT) design, comprising an up -flow central pipe and three satellite downward pipes, represents a novel configuration of a borehole heat exchanger. The novelty lies not only in the geometry of the heat exchanger, but also in the use of materials perfectly adapted to the thermal use for which they have been specified. The central pipe is constructed of a composite bilayer material with very low thermal conductivity, whereas the satellite pipes are based on a novel highly conductive plastic material. The primary objective behind this design was to simplify installation, by using essentially the same drilling and grouting methods used for conventional single -U or double -U borehole heat exchangers. In response to the rising demand for more efficient and affordable ground heat exchangers to be connected to Ground Source Heat Pump (GSHP) systems, this innovation was one of the promising outcomes of the GEOCOND European project. To assess ACT performance, the Geothermal Laboratory on the campus of the Universitat Politecnica de Valencia conducted a number of thermal response tests (TRTs), the experimental results of which are collected and analyzed in this paper. Additionally, a modified version of the Composite Two Region Line Source modeling scheme is described and used to assess the experimental data. A total of four demonstration boreholes - two single -U baseline and two ACT boreholes - have been tested. The experimental investigation using the C2RLS methodology reveals that the ACT configuration has a significantly lower thermal than the typical BHE arrangement and allows a greater specific heat injection rate. Specifically, a borehole resistance drop from 0.149 (m.K)/W to 0.07 (m.K)/W allowing higher injection rates to be achieved without an unsustainable increase in ground temperature. These findings may have significant implications for the development of more efficient and cost-effective GSHP systems., This work was developed within the European project GEOCOND and continued with the European project GEO4CIVHIC, funded by the European Union's Horizon 2020 research and innovation program, under grant agreement s No 727583 and No 792355, respectively.Acknowledgment to the support from the Program for the Re-qualification of the Spanish university system for 2021-2023 (in the framework of the call of the Universitat Politecnica de Valencia) , subsidized by the European Recovery Instrument (financed by the European Union by Next Generation EU) in the framework of the Spanish Recovery, Transformation and Resilience Plan, through the Ministry of Universities, regulated by RD 289/2021 and Order UNI/551/2021.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Thermodynamic Performance Analysis of High Thermal Conductivity Materials in Borehole Heat Exchangers in the European Climate

  • Khattak, Sanober
  • Sanner, Burkhard
  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
[EN] While heat pumps have been acknowledged as a key enabling technology to achieve Net Zero goals, their uptake is limited by their performance and cost. In this paper, a simulation-based study is conducted to analyse the performance of ground source heat pumps (GSHPs) utilising high thermal conductivity materials for the borehole heat exchanger (BHE) pipe (1 W/mK) and grouting (3 W/mK) developed in the GEOCOND project. Exergy analysis is conducted to account for energy quantity and quality with a focus on BHE performance. An annual hourly simulation was performed using DesignBuilder V5.4 and Earth Energy Designer (EED4) for representative cool and hot locations in Europe-Stockholm and Valencia, respectively. For a constant BHE length, the results for Stockholm show that the high conductivity materials result in an increase of about 13% BHE exergy extraction compared to the standard grout and pipe, but no such improvement was observed for Valencia. The difference between outdoor temperature and its dynamic variation from the indoor setpoint is identified as a key factor in the overall GSHP exergetic performance. In future research, we propose a thorough life cycle analysis across diverse locations and varying indoor comfort criteria to pinpoint areas where the high thermal conductivity material can enable cost-effective, sustainable heating and cooling., This research work has been supported financially by the European project GEOCOND (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No. 727583) and by the European project GEO4CIVHIC (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No. 792355).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Theoretical and experimental cost-benefit assessment of borehole heat exchangers (BHEs) according to working fluid flow rate

  • Badenes Badenes, Borja|||0000-0002-3469-9265
  • Mateo Pla, Miguel Ángel|||0000-0002-8059-6996
  • Magraner, Teresa|||0000-0001-5292-1432
  • Soriano Olivares, Javier|||0000-0003-1649-102X
  • Urchueguía Schölzel, Javier Fermín|||0000-0002-3054-3431
[EN] In ground-source heat-pump systems, the heat exchange rate is influenced by various design and operational parameters that condition the thermal performance of the heat pump and the running costs during exploitation. One less-studied area is the relationship between the pumping costs in a given system and the heat exchange rate. This work analyzes the investment and operating costs of representative borehole heat-exchanger configurations with varying circulating flow rate by means of a combination of analytical formulas and case study simulations to allow a precise quantification of the capital and operational costs in typical scenario. As a conclusion, an optimal flow rate minimizing either of both costs can be determined. Furthermore, it is concluded that in terms of operating costs, there is an operational pumping rate above which performance of geothermal systems is energetically strongly penalized., This research work has been supported financially by the European project GEOCOND (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 727583) and by the European project GEO4CIVHIC (funded by the European Union's Horizon 2020 research and innovation program under grant agreement No 792355).