Kinematics of individual muscle units in natural contractions measured in vivo using ultrafast ultrasound

  • Lubel, Emma
  • Grandi Sgambato, Bruno
  • Barsakcioglu, Deren Y
  • Ibáñez, Jaime
  • Tang, Meng-Xing
  • Farina, Dario
Objective. The study of human neuromechanical control at the motor unit (MU) level has predominantly focussed on electrical activity and force generation, whilst the link between these, i.e. the muscle deformation, has not been widely studied. To address this gap, we analysed the kinematics of muscle units in natural contractions. Approach. We combined high-density surface electromyography (HDsEMG) and ultrafast ultrasound (US) recordings, at 1000 frames per second, from the tibialis anterior muscle to measure the motion of the muscular tissue caused by individual MU contractions. The MU discharge times were identified online by decomposition of the HDsEMG and provided as biofeedback to 12 subjects who were instructed to keep the MU active at the minimum discharge rate (9.8 ± 4.7 pulses per second; force less than 10% of the maximum). The series of discharge times were used to identify the velocity maps associated with 51 single muscle unit movements with high spatio-temporal precision, by a novel processing method on the concurrently recorded US images. From the individual MU velocity maps, we estimated the region of movement, the duration of the motion, the contraction time, and the excitation–contraction (E–C) coupling delay. Main results. Individual muscle unit motions could be reliably identified from the velocity maps in 10 out of 12 subjects. The duration of the motion, total contraction time, and E–C coupling were 17.9 $ \pm $ 5.3 ms, 56.6 $ \pm $ 8.4 ms, and 3.8 $ \pm $ 3.0 ms (n = 390 across ten participants). The experimental measures also provided the first evidence of muscle unit twisting during voluntary contractions and MU territories with distinct split regions. Significance. The proposed method allows for the study of kinematics of individual MU twitches during natural contractions. The described measurements and characterisations open new avenues for the study of neuromechanics in healthy and pathological conditions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Non-linearity in motor unit velocity twitch dynamics: implications for ultrafast ultrasound source separation

  • Lubel, Emma
  • Sgambato, Bruno Grandi
  • Rohlén, Robin
  • Ibánez, Jaime
  • Barsakcioglu, Deren Y.
  • Tang, Meng-Xing
  • Farina, Dario
Ultrasound (US) muscle image series can be used for peripheral human-machine interfacing based on global features, or even on the decomposition of US images into the contributions of individual motor units (MUs). With respect to state-of-the-art surface electromyography (sEMG), US provides higher spatial resolution and deeper penetration depth. However, the accuracy of current methods for direct US decomposition, even at low forces, is relatively poor. These methods are based on linear mathematical models of the contributions of MUs to US images. Here, we test the hypothesis of linearity by comparing the average velocity twitch profiles of MUs when varying the number of other concomitantly active units. We observe that the velocity twitch profile has a decreasing peak-to-peak amplitude when tracking the same target motor unit at progressively increasing contraction force levels, thus with an increasing number of concomitantly active units. This observation indicates non-linear factors in the generation model. Furthermore, we directly studied the impact of one MU on a neighboring MU, finding that the effect of one source on the other is not symmetrical and may be related to unit size. We conclude that a linear approximation is partly limiting the decomposition methods to decompose full velocity twitch trains from velocity images, highlighting the need for more advanced models and methods for US decomposition than those currently employed.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Repair of Long Peripheral Nerve Defects in Sheep, A Translational Model for Nerve Regeneration

  • Contreras, Estefanía|||0000-0002-8645-2790
  • Traserra Call, Sara
  • Bolívar Martín, Sara|||0000-0003-2966-6845
  • Forés Vineta, Joaquim|||0000-0003-1728-6212
  • José Cunilleras, Eduard|||0000-0002-4536-7717
  • Delgado Martínez, Ignacio|||0000-0003-1616-8943
  • García Arnas, Félix|||0000-0001-6651-3173
  • Udina i Bonet, Esther|||0000-0003-1954-8562
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
Despite advances in microsurgery, full functional recovery of severe peripheral nerve injuries is not commonly attained. The sheep appears as a good preclinical model since it presents nerves with similar characteristics to humans. In this study, we induced 5 or 7 cm resection in the peroneal nerve and repaired with an autograft. Functional evaluation was performed monthly. Electromyographic and ultrasound tests were performed at 6.5 and 9 months postoperation (mpo). No significant differences were found between groups with respect to functional tests, although slow improvements were seen from 5 mpo. Electrophysiological tests showed compound muscle action potentials (CMAP) of small amplitude at 6.5 mpo that increased at 9 mpo, although they were significantly lower than the contralateral side. Ultrasound tests showed significantly reduced size of tibialis anterior (TA) muscle at 6.5 mpo and partially recovered size at 9 mpo. Histological evaluation of the grafts showed good axonal regeneration in all except one sheep from autograft 7 cm (AG7) group, while distal to the graft there was a higher number of axons than in control nerves. The results indicate that sheep nerve repair is a useful model for investigating long-gap peripheral nerve injuries.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Assessment of focused ultrasound stimulation to induce peripheral nerve activity and potential damage in vivo

  • Rodriguez Meana, Bruno|||0000-0003-0052-7446
  • Santos Nogueira, Eva|||0000-0002-5917-3534
  • Trujillo-Vázquez, Sònia
  • Jakob, Anette
  • Udina i Bonet, Esther|||0000-0003-1954-8562
  • Fournelle, Marc
  • Navarro, X. (Xavier)|||0000-0001-9849-902X
Peripheral neuroprostheses are aimed to restore loss of sensory and motor functions by interfacing axons in the peripheral nerves. Most common interfaces in neuroprostheses are electrodes that establish electrical connection with peripheral axons. However, some challenges arise related to long-term functionality, durability, and body response. Recently, focused ultrasound stimulation (FUS) has emerged as a non-invasive approach to modulate the nervous system. However, it is controversial whether FUS can induce axon depolarization. We have assessed FUS applied in vivo to the rat peripheral nerve, with two objectives: first, to test whether FUS activates peripheral nerves under different stimulation conditions, and second, to evaluate if FUS inflicts damage to the nerve. FUS was delivered with three ultrasound transducers (Sonic Concept H115, H107, and H102) covering the largest set of parameters examined for FUS of peripheral nerves so far. We did not obtain reliable evoked action potentials in either nerves or muscles, under any FUS condition applied, neither over the skin nor directly to the nerve exposed. Additional experiments ex vivo and in vivo on mice, confirmed this conclusion. When FUS stimulation was applied directly to the exposed sciatic nerve, neuromuscular function decreased significantly, and recovered one week later, except for FUS at 0.25 MHz. Histologically, degenerating nerve fibers were observed, with a tendency to be higher with the lower FUS frequency. Past reports on the ability of ultrasound to stimulate the peripheral nerve are controversial. After testing a wide range of FUS conditions, we conclude that it is not a reliable and safe method for stimulating the peripheral nerve. Special consideration should be taken, especially when low-frequency FUS is applied, as it may lead to nerve damage.