Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A novel electrochemical strategy for NT-proBNP detection using IMFET for monitoring heart failure by saliva analysis

  • Ben Halima, Hamdi
  • Bellagambi, Francesca G
  • Hangouët, Marie
  • Alcacer, Albert
  • Pfeiffer, Norman
  • Heuberger, Albert
  • Zine, Nadia
  • Bausells, Joan
  • Elaissari, Abdelhamid
  • Errachid, Abdelhamid
Heart failure (HF) is a chronic cardiovascular disease that represents main cause of mortality worldwide, particularly for elderly. N-terminal pro-brain natriuretic peptide (NT-proBNP) was identified as the gold standard biomarker for HF diagnosis and therapy monitoring. Presently, saliva analysis represents an emerging and powerful tool for clinical applications and electrochemical immunosensors have shown their potential in Healthcare applications as selective and reliable systems for detecting clinical biomarkers. This work presents the detection of NT-proBNP in saliva samples by an immunologically modified Field effect Transistor (IMFET). TESUD ((11-triethoxysilyl) undecanal) was used as cross-linker to immobilise anti-NT-proBNP antibody onto the device. Our IMFET that was then tested in different matrices (e.g. phosphate buffered saline (PBS), artificial saliva and human saliva) using electrochemical impedance spectroscopy (EIS), and it resulted selective to NT-proBNP with good sensitivity (detection limit of 0.02 pg/mL) and a wide linear range (0.02-1 pg/mL and 0.5-20 pg/mL). Finally, NT-proBNP concentration in ten saliva samples was determined by performing the standard addition method. An enzyme-linked immunosorbent assay was used for confirming IMFET results, highlighting both IMFET accuracy (analyte recovery of 99 ± 8%) and precision (coefficient of variation always <10%), and supporting the suitability of the device for determining salivary NT-proBNP., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

One-step impedimetric NT-proBNP aptasensor targeting cardiac insufficiency in artificial saliva

  • Ruankham, Waralee
  • Morales Frías, Isaac Aarón
  • Phopin, Kamonrat
  • Tantimongcolwat, Tanawut
  • Bausells, Joan
  • Zine, Nadia
  • Errachid, Abdelhamid
Currently, sensitive and accurate approaches for diagnosis, rapid assessment, and cardiac biomarker monitoring in patients with heart failure are needed. In this context, the advantages of aptamers over traditional antibodies have been employed to fabricate a single-step impedimetric N-terminal pro b-type natriuretic peptide (NT-proBNP)-modified gold microelectrode array. The development of an electrochemical aptasensing platform was based on the coimmobilization of alkanethiol self-assembled monolayers and amine-terminated aptamer that specifically recognized cardiac NT-proBNP protein resulting in charge electron transfer. Electroimpedimetric signals of the sensor were observed to be linear to the NT-proBNP concentrations in the range of 5.0 × 10-3 to 1.0 pg mL-1 (R2 = 0.9624), while achieving a low detection limit of 5.0 × 10-3 pg mL-1. Clinically relevant detection levels for NT-proBNP were achieved in a simple, rapid, and label-free measurement using artificial saliva, which was highlighted to be specific, regenerative, and selective over potential interferers occurring during the processes of cardiac insufficiency, Therefore, the novel NT-proBNP aptasensor is a promising point-of-care tool exhibiting safe, non-invasive, affordable, and non-prescription home use accessible to overcome the limitations associated with conventional ELISA and previous aptasensing., This work was financially supported by the Franco-Thai Cooperation Programme in Higher Education and Research/Franco-Thai Mobility Programme/ PHC SIAM 2020–2021; the POC4allergies project from ERA PerMed ERA-NET [grant number 768686]; and the Bionanosens project from the European Union's Horizon 2020 [grant number 951887]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A Novel IMFET Biosensor Strategy for Interleukin-10 Quantification for Early Screening Heart Failure Disease in Saliva

  • Ben Halima, Hamdi
  • Bellagambi, Francesca G.
  • Hangouët, Marie
  • Alcacer, Albert
  • Pfeiffer, Norman
  • Heuberger, Albert
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
We propose a salivary Interleukin-10 detection strategy as part of an easily integrable Lab-on-Chip and Point-of-Care IMFET for multi-detection Heart Failure (HF) biomarkers. Our developed IMFET showed good linearity between increasing IL-10 concentration and the charge transfer resistance in both standard solutions and real saliva samples with a LOD of 0.02 pg mL−1. Moreover, the cross-selectivity study showed that the developed IMFET was highly selective towards IL-10 against other HF biomarkers. The precision of our IMFET was also evaluated, and the difference between the determined IL-10 concentration using the standard addition method and its expected one is<20 %., The authors acknowledge the financial support of the European Union's Horizon 2020 research and innovation program, Project NMBP-13-2017 KardiaTool (Grant agreement No. 768686). The authors acknowledge the financial support from the POC4allergies project (Grant Agreement No. 768686), which received funding from ERA PerMed ERA-NET, and the financial support from Bionanosens project (Grant agreement No. 951887), which received funding from the European Union's Horizon 2020., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Copper-free click chemistry assisted antibodies for immunodetection of interleukin-10 in saliva

  • Hilali, Nazha
  • Ruankham, Waralee
  • Aarón Morales Frías, Isaac
  • Bellagambi, Francesca G.
  • Hangouët, Marie
  • Martin, Marie
  • Bausells, Joan
  • Mohammadi, Hasna
  • Amine, Aziz
  • Zine, Nadia
  • Errachid, Abdelhamid
Interleukin-10 (IL-10) is an anti-inflammatory cytokine that is secreted in response to an acute phase inflammation in patients who are suffering from heart failure (HF). The aim of this work was to develop an electrochemical biosensor for determining salivary IL-10 levels. Biofunctionalization strategy was improved through the use of copper-free click chemistry for the developed sensor due to its advantages, leading to high quantitative yields of stable triazoles, rapid reaction, no cytotoxic Cu(I) catalyst requirement, and high specificity of cyclooctynes toward azides. The approach involved in binding of dibenzocyclooctyne acid (DBCO-COOH) to thiol-azide assembled gold microelectrodes, later capturing the monoclonal IL-10 antibody (IL-10 mAb), and ultimately allowing direct detection of IL-10 antigen. Fourier transform infrared spectroscopy (FTIR) and nanoplotter associated with fluorescence microscopy methods have been employed to analyze and prove the biofunctionalization of the gold microelectrodes. Moreover, the electrochemical impedance spectroscopy (EIS) technique was used for detecting IL-10 antigen. The developed immunosensor showed a semi-logarithmic linear range, from 0.1 pg/mL to 5 pg/mL with R2 = 0.9815 and a limit of quantitation (LOQ) of 0.1 pg/mL with relative standard deviation (RSD) of 10.67%. The specificity of the immunosensor was evaluated using an inflammatory cytokine, and none of it generated detectable EIS signals. Finally, the successful analysis of saliva samples from a healthy volunteer without Coronavirus (COVID-19) infection demonstrated the usefulness of the developed immunosensor., The authors acknowledge financial support from the CAMPUS FRANCE program under grant agreement PHC Maghreb n° 39382RE, PHC phase 2, French Eiffel scholarship 2020, CNRST of Morocco, as well as the financial support of the POC4allergies project (Grant Agreement No. 768686), which received funding from ERA PerMed ERA-NET, and the financial support from Bionanosens project (Grant agreement No. 951887), which received funding from the European Union's Horizon 2020., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Immuno field-effect transistor (ImmunoFET) for detection of salivary cortisol using potentiometric and impedance spectroscopy for monitoring heart failure

  • Ben Halima, Hamdi
  • Bellagambi, Francesca G
  • Brunon, Fabien
  • Alcacer, Albert
  • Pfeiffer, Norman
  • Heuberger, Albert
  • Hangouët, Marie
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
Cortisol, a steroid hormone mostly known as "the stress hormone," plays many essential functions in humans due its involvement in several metabolic pathways. It is well-known that cortisol dysregulation is implied in evolution and progression of several chronic pathologies, including cardiac diseases such as heart failure (HF). However, although several sensors have been proposed to date for the determination of cortisol, none of them has been designed for its determination in saliva in order to monitor HF progression. In this work, a silicon nitride based Immuno field-effect transistor (ImmunoFET) has been proposed to quantify salivary cortisol for HF monitoring. Sensitive biological element was represented by anti-cortisol antibody bound onto the ISFET gate via 11-triethoxysilyl undecanal (TESUD) by vapor-phase method. Potentiometric and electrochemical impedance spectroscopy (EIS) measurements were carried out for preliminary investigations on device responsiveness. Subsequently, a more sensitive detection was obtained using electrochemical EIS. The proposed device has proven to have a linear response (R2 always >0.99), to be sensitive (with a limit of detection, LoD, of 0.005 ± 0.002 ng/mL), selective in case of other HF biomarkers (e.g. N-terminal pro B-type natriuretic peptide (NT-proBNP), tumor necrosis factor-alpha (TNF-α), and interleukin 10 (IL-10)), and accurate in cortisol quantification in saliva sample by performing the standard addition method., The authors acknowledge the financial support of the European Union's Horizon 2020 research and innovation programme , Project NMBP-13-2017 KardiaTool (Grant agreement No. 768686 ). The financial support of the POC4allergies project (ERAPERMED2019-127), which received funding from ERA PerMed ERA-NET , and the financial support from Bionanosens project (Grant agreement No. 951887 ), which received funding from the European Union's Horizon 2020 ., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Selective excitation of individual nanoantennas by pure spectral phase control in the ultrafast coherent regime

  • Accanto, Nicolò
  • Roque Fernández, Pablo Manuel de
  • Galvan-Sosa, Marcial
  • Hancu, Ion Michael
  • Hulst, Niek van
Coherent control is an ingenious tactic to steer a system to a desired optimal state by tailoring the phase of an incident ultrashort laser pulse. A relevant process is the two-photon–induced photoluminescence (TPPL) of nanoantennas, as it constitutes a convenient route to map plasmonic fields, and has important applications in biological imaging and sensing. Unfortunately, coherent control of metallic nanoantennas is impeded by their ultrafast femtosecond dephasing times so far limiting control to polarization and spectral optimization. Here, we report that phase control of the TPPL in resonant gold nanoantennas is possible. We show that, by compressing pulses shorter than the localized surface plasmon dephasing time (<20 fs), a very fast coherent regime develops, in which the two-photon excitation is sensitive to the phase of the electric field and can therefore be controlled. Instead, any phase control is gone when using longer pulses. Finally, we demonstrate pure phase control by resorting to a highly sensitive closed-loop strategy, which exploits the phase differences in the ultrafast coherent response of different nanoantennas, to selectively excite a chosen antenna. These results underline the direct and intimate relation between TPPL and coherence in gold nanoantennas, which makes them interesting systems for nanoscale nonlinear coherent control., This research was funded by the European Commission (ERC Adv. Grant 670949-LightNet); Spanish Severo Ochoa Programme for Centres of Excellence in R&D (SEV-2015-0522); Plan National Projects MICINN FIS2012-35527, MINECO FIS2015-69258-P and MCIU PGC2018-096875-B-I00 and cofunded by the Fondo Europeo de Desarrollo Regional (FEDER); the Catalan AGAUR (2014 SGR01540 and 2017 SGR1369); Fundació Privada Cellex; Fundació Privada Mir-Puig and Generalitat de Catalunya through the Centres de Recerca de Catalunya (CERCA) program. PMdR acknowledges financial support from the Spanish Government MINECO-FPI grant and European Science Foundation under the PLASMON- BIONANOSENSE Exchange Grant program. MGS acknowledges financial support from grants MICINN TEC2011-22422 and MINECO TEC2014-52642-C2-1-R
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Selective excitation of individual nanoantennas by pure spectral phase control in the ultrafast coherent regime

  • Accanto, Nicolò
  • Roque Fernández, Pablo Manuel de
  • Galvan-Sosa, Marcial
  • Hancu, Ion Michael
  • Hulst, Niek van
Coherent control is an ingenious tactic to steer a system to a desired optimal state by tailoring the phase of an incident ultrashort laser pulse. A relevant process is the two-photon–induced photoluminescence (TPPL) of nanoantennas, as it constitutes a convenient route to map plasmonic fields, and has important applications in biological imaging and sensing. Unfortunately, coherent control of metallic nanoantennas is impeded by their ultrafast femtosecond dephasing times so far limiting control to polarization and spectral optimization. Here, we report that phase control of the TPPL in resonant gold nanoantennas is possible. We show that, by compressing pulses shorter than the localized surface plasmon dephasing time (<20 fs), a very fast coherent regime develops, in which the two-photon excitation is sensitive to the phase of the electric field and can therefore be controlled. Instead, any phase control is gone when using longer pulses. Finally, we demonstrate pure phase control by resorting to a highly sensitive closed-loop strategy, which exploits the phase differences in the ultrafast coherent response of different nanoantennas, to selectively excite a chosen antenna. These results underline the direct and intimate relation between TPPL and coherence in gold nanoantennas, which makes them interesting systems for nanoscale nonlinear coherent control., This research was funded by the European Commission (ERC Adv. Grant 670949-LightNet); Spanish Severo Ochoa Programme for Centres of Excellence in R&D (SEV-2015-0522); Plan National Projects MICINN FIS2012-35527, MINECO FIS2015-69258-P and MCIU PGC2018-096875-B-I00 and cofunded by the Fondo Europeo de Desarrollo Regional (FEDER); the Catalan AGAUR (2014 SGR01540 and 2017 SGR1369); Fundació Privada Cellex; Fundació Privada Mir-Puig and Generalitat de Catalunya through the Centres de Recerca de Catalunya (CERCA) program. PMdR acknowledges financial support from the Spanish Government MINECO-FPI grant and European Science Foundation under the PLASMON- BIONANOSENSE Exchange Grant program. MGS acknowledges financial support from grants MICINN TEC2011-22422 and MINECO TEC2014-52642-C2-1-R, Postprint (published version)