Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring

  • Barceló-Rico, Fátima
  • Rossetti, Paolo
  • Vehi, Josep
  • Diez, José-Luís|||0000-0002-5659-1212
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Minimally or noninvasive continuous glucose monitors estimate plasma glucose from compartments alternative to blood, and may revolutionize the management of diabetes. However, the accuracy of current devices is still poor and it may partly depend on low performance of the implemented calibration algorithm. Here, a new adaptive calibration algorithm based on a population local-model-based intercompartmental glucose dynamic model is proposed. The novelty consists in the adaptation of data normalization parameters in real time to estimate and compensate patient's sensitivity variations. Adaptation is performed to minimize mean absolute relative deviation at the calibration points with a time window forgetting strategy. Four calibrations are used: preprandial and 1.5 h postprandial at two different meals. Two databases are used for validation: 1) a 9-hCGMSGold (Medtronic, Northridge, USA) time series with paired reference glucose values from a clinical study in 17 subjects with type 1 diabetes; 2) data from 30 virtual patients (UVa simulator, Virginia, USA), where inter-and intrasubject variability of sensor's sensitivity were simulated. Results show how the adaptation of the normalization parameters improves the performance of the calibration algorithm since it counteracts sensor sensitivity variations. This improvement is more evident in one-week simulations., Manuscript received April 17, 2012; revised September 10, 2012 and January 21, 2013; accepted March 11, 2013. Date of publication March 19, 2013; date of current version May 1, 2013. This work was supported in part by the Spanish Ministry of Science and Innovation under Project DPI2010-20764-C02 and in part by the European Union under Grant FP7-PEOPLE-2009-IEF, Ref 252085. The work of F. Barcelo-Rico was supported by the Spanish Ministry of Education (FPU AP2008-02967).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

New possibilistic method for discovering linear local behavior using hyper-Gaussian distributed membership function

  • Barcelo-Rico, F.
  • Diez, José-Luís|||0000-0002-5659-1212
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] This paper presents a method to find a model of a system based on the integration of a set of local models. Mainly, properties are sought for the local models: independence of clusters and interpretability of their validity. This has been achieved through the introduction of a possibilistic clustering for the first property and a pre-fixed shape of the membership functions for the second one. A new cost index for the clustering optimization problem has been defined consisting of two terms: one for global error and another for local errors. By giving higher importance to the local errors term, local models valid regionally can be found. To avoid local optima and numerical issues, the parameters of the models are found using global optimization. This new method has been applied to several data sets, and results show how the desired characteristics can be achieved in the resulting models., The authors acknowledge the partial funding of this work by the projects: the national projects DPI2007-66728-C02-01 and DPI2008-06737-C02-01. The first author is recipient of a fellowship from the Spanish Ministry of Education (FPU AP2008-02967). The translation of this paper was funded by the Universidad Politecnica de Valencia, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A multiple local models approach to accuracy improvement in continuous glucose monitoring

  • Barceló Rico, Fátima
  • Rossetti ., Paolo
  • Bondía Company, Jorge|||0000-0001-7286-3719
  • Diez, José-Luís|||0000-0002-5659-1212
[EN] Background: Continuous glucose monitoring (CGM) devices estimate plasma glucose (PG) from measurements in compartments alternative to blood. The accuracy of currently available CGM is yet unsatisfactory and may depend on the implemented calibration algorithms, which do not compensate adequately for the differences of glucose dynamics between the compartments. Here we propose and validate an innovative calibration algorithm for the improvement of CGM performance. Methods: CGM data from GlucoDay (R) (A. Menarini, Florence, Italy) and paired reference PG have been obtained from eight subjects without diabetes during eu-, hypo-, and hyperglycemic hyperinsulinemic clamps. A calibration algorithm based on a dynamic global model (GM) of the relationship between PG and CGM in the interstitial space has been obtained. The GM is composed by independent local models (LMs) weighted and added. LMs are defined by a combination of inputs from the CGM and by a validity function, so that each LM represents to a variable extent a different metabolic condition and/or sensor-subject interaction. The inputs best suited for glucose estimation were the sensor current I and glucose estimations (G) over cap, at different time instants [I-k, Ik-1, (G) over cap (k-1)] (IIG). In addition to IIG, other inputs have been used to obtain the GM, achieving different configurations of the calibration algorithm. Results: Even in its simplest configuration considering only IIG, the new calibration algorithm improved the accuracy of the estimations compared with the manufacturer's estimate: mean absolute relative difference (MARD) = 10.8 +/- 1.5% versus 14.7 +/- 5.4%, respectively (P = 0.012, by analysis of variance). When additional exogenous signals were considered, the MARD improved further (7.8 +/- 2.6%, P<0.05). Conclusions: The LM technique allows for the identification of intercompartmental glucose dynamics. Inclusion of these dynamics into the calibration algorithm improves the accuracy of PG estimations., The authors acknowledge the partial funding of this work by the Spanish Ministry of Science and Innovation projects DPI2007-66728-C02-01 and DPI2010-20764-C02-01 and by the European Union through FEDER funds and grant FP7-PEOPLE-2009-IEF, Reference 252085. F.B.R. is the recipient of a fellowship (FPU AP2008-02967) from the Spanish Ministry of Education.