Skip to main content

MODELACION DE LA APLICACION DE LA TECNOLOGIA DE MEMBRANAS PARA LA VALORIZACION ENERGETICA DE LA MATERIA ORGANICA DEL AGUA RESIDUAL Y LA MINIMIZACION DE LOS FANGOS PRODUCIDOS. DESARROLLO DE LOS ALGORIT

BES-2009-023712

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Formación de Recursos Humanos de Investigación
Subprogram Subprograma de Formación de Personal Investigador (FPI)
Call Contratos Predoctorales
Call year 2009
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Formación e Incorporación de Investigadores
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Sub-critical filtration conditions of commercial hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system: The effect of gas sparging intensity

  • Robles Martínez, Ángel
  • Ruano García, María Victoria
  • García Usach, Mª Francisca
  • FERRER, J.
A submerged anaerobic MBR demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON®, Koch Membrane Systems, PUR-PSH31) was operated using municipal wastewater at high levels of mixed liquor total solids (MLTS) (above 22gL -1). A modified flux-step method was applied to assess the critical flux (J C) at different gas sparging intensities. The results showed a linear dependency between J C and the specific gas demand per unit of membrane area (SGD m). J C ranged from 12 to 19LMH at SGD m values of between 0.17 and 0.5Nm 3h -1m -2, which are quite low in comparison to aerobic MBR. Long-term trials showed that the membranes operated steadily at fluxes close to the estimated J C, which validates the J C obtained by this method. After operating the membrane for almost 2years at sub-critical levels, no irreversible fouling problems were detected, and therefore, no chemical cleaning was conducted. © 2012 Elsevier Ltd., This research work has been supported by the Spanish Research Foundation (CICYT Projects CTM2008-06809-C02-01 and CTM2008-06809-C02-02, and MICINN FPI Grant BES-2009-023712) and Generalitat Valenciana (Projects GVA-ACOMP2010/130 and GVA-ACOMP2011/182), which are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Model-based automatic tuning of a filtration control system for submerged anaerobic membrane bioreactors (AnMBR)

  • Robles Martínez, Ángel
  • Ruano García, María Victoria
  • Ribes Bertomeu, Jose
  • Seco Torrecillas, Aurora
  • FERRER, J.
This paper describes a model-based method to optimise filtration in submerged AnMBRs. The method is applied to an advanced knowledge-based control system and considers three statistical methods: (1) sensitivity analysis (Morris screening method) to identify an input subset for the advanced controller; (2) Monte Carlo method (trajectory-based random sampling) to find suitable initial values for the control inputs; and (3) optimisation algorithm (performing as a supervisory controller) to re-calibrate these control inputs in order to minimise plant operating costs. The model-based supervisory controller proposed allowed filtration to be optimised with low computational demands (about 5min). Energy savings of up to 25% were achieved when using gas sparging to scour membranes. Downtime for physical cleaning was about 2.4% of operating time. The operating cost of the AnMBR system after implementing the proposed supervisory controller was about 0.045/m3, 53.3% of which were energy costs., This research work has been supported by the Spanish Ministry of Science and Innovation (MICINN, Projects CTM2008-06809CO2-01/02 and FPI grant BES-2009-023712) and the Spanish Ministry of Economy and Competitiveness (MINECO, Projects CTM2011-28595-0O2-01/02), jointly with the European Regional Development Fund (ERDF) and Generalitat Valenciana GVAACOMP2013/203, which are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Factors that affect the permeability of commercial hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system

  • Robles Martínez, Ángel
  • Ruano García, María Victoria
  • Ribes Bertomeu, Jose
  • FERRER, J.
A demonstration plant with two commercial HF ultrafiltration membrane modules (PURON (R), Koch Membrane Systems, PUR-PSH31) was operated with urban wastewater. The effect of the main operating variables on membrane performance at sub-critical and supracritical filtration conditions was tested. The physical operating variables that affected membrane performance most were gas sparging intensity and back-flush (BF) frequency. Indeed, low gas sparging intensities (around 0.23 Nm(3) h(-1) m(-2)) and low BF frequencies (30s back-flush for every 10 basic filtration relaxation cycles) were enough to enable membranes to be operated sub-critically even when levels of mixed liquor total solids were high (up to 25 g L-1). On the other hand, significant gas sparging intensities and BF frequencies were required in order to maintain long-term operating at supra-critical filtration conditions. After operating for more than two years at sub-critical conditions (transmembrane flux between 9 and 13.3 LMH at gas sparging intensities of around 0.23 Nm(3) h(-1) m(-2) and MLTS levels from around 10-30 g L-1) no significant irreversible/irrecoverable fouling problems were detected (membrane permeability remained above 100 LMH bar(-1) and total filtration resistance remained below 10(13) m(-1)), therefore no chemical cleaning was conducted. Membrane performance was similar to the aerobic HF membranes operated in full-scale MBR plants. (C) 2012 Elsevier Ltd. All rights reserved., This research work has been supported by the Spanish Research Foundation (CICYT Projects CTM2008-06809-C02-01 and CTM2008-06809-C02-02, and MICINN FPI grant BES-2009-023712) and Generalitat Valenciana (Projects GVA-ACOMP2010/130 and GVA-ACOMP2011/182), which are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Sub-critical long-term operation of industrial scale hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system

  • Robles Martínez, Ángel
  • Ruano García, María Victoria
  • Ribes Bertomeu, Jose
  • FERRER, J.
The aim of this study was to evaluate the long-term performance of hollow-fibre (HF) membranes used to treat urban wastewater in a submerged anaerobic MBR when operating sub-critically. To this end, a demonstration plant with two industrial scale HF ultrafiltration membrane modules was operated under different conditions. The main factor affecting membrane performance was the concentration of mixed liquor total solids (MLTS). The reversible fouling rate remained low even when MLTS levels (about 25 g L−1) in the membrane tank were high. No chemical cleaning was conducted whilst operating the plant for more than one year because no irreversible fouling problems were detected. The almost complete absence of irreversible fouling was mainly attributed to: operating at sub-critical filtration conditions; establishing a proper membrane operating mode; and to the characteristics of the anaerobic environment. No chemical precipitation problems were observed in the membranes due to the relatively low operating pH (always below 7) of the sludge. The biogas sparging encouraged high levels of dissolved CO2 in the sludge, resulting in pH levels below 7 and alkalinity values around 600 mg CaCO3 L−1., This research work has been supported by the Spanish Research Foundation (CICYT Projects CTM2008-06809-C02-01 and CTM2008-06809-C02-02, and MICINN FPI Grant BES-2009-023712) and Generalitat Valenciana (Projects GVA-ACOMP2010/130 and GVA-ACOMP2011/1182), which are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of total solids concentration on membrane permeability in a submerged hollow-fibre anaerobic membrane bioreactor

  • Robles Martínez, Ángel
  • Durán Pinzón, Freddy
  • Ruano García, María Victoria
  • Ribes Bertomeu, Jose
  • Ferrer Polo, José
The main aim of this work was to study the influence of the mixed liquor total solids (MLTS) concentration on membrane permeability (K 20) in a submerged anaerobic membrane bioreactor (SAnMBR) pilot plant, which is equipped with industrial hollow-fibre membranes and treats urban wastewater. This pilot plant was operated at 33°C and 70 days of SRT. Two different transmembrane fluxes (13.3 and 10 LMH) were tested with a gas sparging intensity of 0.23 Nm 3 m -2 h -1 (measured as Specific Gas Demand referred to membrane area). A linear dependence of K 20 on MLTS concentration was observed within a range of MLTS concentration from 13 to 32 g L -1 and J 20 of 10 LMH. K 20 was maintained at sustainable values (about 100 LMH bar -1) even at high MLTS concentrations (up to 20 g L -1). In addition, several short-tests were carried out when the membranes were operated at high MLTS concentrations in order to assess the effect of the physical cleaning strategies (relaxation and back-flush) on membrane performance. It was observed that, with the applied gas sparging intensity, the duration of the relaxation stage did not critically affect the membrane performance. On the other hand, the required back-flush frequency was considerably affected by the MLTS concentration. © IWA Publishing 2012., This research work has been supported by the Spanish Research Foundation (CICYT Projects CTM2008-06809-C02-01 and CTM2008-06809-C02-02, and MICINN FPI grant BES-2009-023712) and Generalitat Valenciana (Projects GVA-ACOMP2010/130 and GVA-ACOMP2011/182), which are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Performance of industrial scale hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system at mesophilic and psychrophilic conditions

  • Robles Martínez, Ángel
  • Ruano García, María Victoria
  • Ribes Bertomeu, Jose
  • FERRER, J.
The aim of this work was to evaluate the effect of temperature on the performance of industrial hollow-fibre (HF) membranes treating urban wastewater in a submerged anaerobic MBR system (SAnMBR). To this end, a demonstration plant with two commercial HF ultrafiltration membrane modules (PURON®, Koch Membrane Systems, PUR-PSH31) was operated at 20, 25 and 33 °C. The mixed liquor total solid (MLTS) level was a key factor affecting membrane permeability (K). K was higher under psychrophilic than mesophilic conditions when operating at similar transmembrane fluxes and MLTS, because the biomass activity of the psychrophilic mixed liquor was lower than the mesophilic mixed liquor. Thus, lower extracellular polymeric substances (EPSs) and soluble microbial products (SMPs) levels were observed at psychrophilic conditions, which affected not only the three-dimensional floc matrix, but also the fouling propensity. However, no chemical cleaning was needed during the experimental period (almost 1 year) because no irreversible fouling problems were detected., This research work has been supported by the Spanish Research Foundation (CICYT Projects CTM2008-06809-C02-01 and CTM2008-06809-C02-02, and MICINN FPI Grant BES-2009-023712) and Generalitat Valenciana (Projects GVA-ACOMP2010/130 and GVA-ACOMP2011/182), which are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Advanced control system for optimal filtration in submerged anaerobic MBRs (SAnMBRs)

  • Robles Martínez, Ángel
  • Ruano García, María Victoria
  • Ribes Bertomeu, Jose
  • FERRER, J.
The main aim of this study was to develop an advanced controller to optimise filtration in submerged anaerobic MBRs (SAnMBRs). The proposed controller was developed, calibrated and validated in a SAnMBR demonstration plant fitted with industrial-scale hollow-fibre membranes with variable influent flow and load. This 2-layer control system is designed for membranes operating sub-critically and features a lower layer (on/off and PID controllers) and an upper layer (knowledge-based controller). The upper layer consists of a MIMO (multiple-input-multiple-output) control structure that regulates the gas sparging for membrane scouring and the frequency of physical cleaning (ventilation and back flushing). The filtration process is monitored by measuring the fouling rate on-line. This controller demonstrated its ability to keep fouling rates low (close to 0 mbar mm(-1)) by applying sustainable gas sparging intensities (approx. 0.23 Nm(3) h(-1) m(-2)). It also reduced the downtimes needed for ventilation and back-flushing (less than 2% of operating time)., This research has been supported by the Spanish Research Foundation (CICYT Projects CTM2008-06809-C02-01 and CTM2008-06809-C02-02, and MICINN FPI Grant BES-2009-023712) and Generalitat Valenciana (Projects GVA-ACOMP2010/130 and GVA-ACOMP2011/182), which are gratefully acknowledged.