MODELADO BIOMECANICO DEL TEJIDO MUSCULO-ESQUELETICO ABDOMINAL

BES-2012-053422

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Formación de Personal Investigador
Subprogram Subprograma de Ayudas de Formación de Personal Investigador
Call Contratos Predoctorales
Call year 2012
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Towards the mechanical characterization of abdominal wall by inverse analysis

  • Simón-Allué, R.
  • Calvo, B.
  • Oberai, A. A.
  • Barbone, P. E.
The aim of this study is to characterize the passive mechanical behaviour of abdominal wall in vivo in an animal model using only external cameras and numerical analysis. The main objective lies in defining a methodology that provides in vivo information of a specific patient without altering mechanical properties. It is demonstrated in the mechanical study of abdomen for hernia purposes. Mechanical tests consisted on pneumoperitoneum tests performed on New Zealand rabbits, where inner pressure was varied from 0 mmHg to 12 mmHg. Changes in the external abdominal surface were recorded and several points were tracked. Based on their coordinates we reconstructed a 3D finite element model of the abdominal wall, considering an incompressible hyperelastic material model defined by two parameters. The spatial distributions of these parameters (shear modulus and non linear parameter) were calculated by inverse analysis, using two different types of regularization: Total Variation Diminishing (TVD) and Tikhonov (H1). After solving the inverse problem, the distribution of the material parameters were obtained along the abdominal surface. Accuracy of the results was evaluated for the last level of pressure. Results revealed a higher value of the shear modulus in a wide stripe along the craneo-caudal direction, associated with the presence of linea alba in conjunction with fascias and rectus abdominis. Non linear parameter distribution was smoother and the location of higher values varied with the regularization type. Both regularizations proved to yield in an accurate predicted displacement field, but H1 obtained a smoother material parameter distribution while TVD included some discontinuities. The methodology here presented was able to characterize in vivo the passive non linear mechanical response of the abdominal wall.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Developing a new methodology to characterize in vivo the passive mechanical behavior of abdominal wall on an animal model

  • Simón-Allué, R.
  • Martínez Montiel, J.M.
  • Bellón, J.M.
  • Calvo, B.
The most common surgical repair of abdominal wall hernia goes through implanting a mesh that substitutes the abdominal muscle/fascia while it is healing. To reduce the risk of relapse or possible complications, this mesh needs to mimic the mechanical behavior of the muscle/fascia, which nowadays is not fully determined. The aim of this work is to develop a methodology to characterize in vivo the passive mechanical behavior of the abdominal wall. For that, New Zealand rabbits were subjected to pneumoperitoneum tests, taking the inner pressure from 0 mmHg to 12 mmHg, values similar to those used in human laparoscopies. Animals treated were divided into two groups: healthy and herniated animals with a surgical mesh (polypropylene SurgiproTM Covidien) previously implanted. All experiments were recorded by a stereo rig composed of two synchronized cameras. During the postprocessing of the images, several points over the abdominal surface were tracked and their coordinates extracted for different levels of internal pressure. Starting from that, a three dimensional model of the abdominal wall was reconstructed. Pressure–displacement curves, radii of curvature and strain fields were also analysed. During the experiments, animals tissue mostly deformed during the first levels of pressure, showing the noticeable hyperelastic passive behavior of abdominal muscles. Comparison between healthy and herniated specimen displayed a strong stiffening for herniated animals in the zone where the high density mesh was situated. Cameras were able to discern this change, so this method can be used to measure the possible effect of other meshes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Mechanical behavior of surgical meshes for abdominal wall repair: In vivo versus biaxial characterization

  • Simón-Allué, R.
  • Ortillés, A.
  • Calvo, B.
Despite the widespread use of synthetic meshes in the surgical treatment of the hernia pathology, the election criteria of a suitable mesh for specific patient continues to be uncertain. Thus, in this work, we propose a methodology to determine in advance potential disadvantages on the use of certain meshes based on the patient-specific abdominal geometry and the mechanical features of the certain meshes. To that purpose, we have first characterized the mechanical behavior of four synthetic meshes through biaxial tests. Secondly, two of these meshes were implanted in several New Zealand rabbits with a total defect previously created on the center of the abdominal wall. After the surgical procedure, specimen were subjected to in vivo pneumoperitoneum tests to determine the immediate post-surgical response of those meshes after implanted in a healthy specimen. Experimental performance was recorded by a stereo rig with the aim of obtaining quantitative information about the pressure-displacement relation of the abdominal wall. Finally, following the procedure presented in prior works (Simón-Allué et al., 2015, 2017), a finite element model was reconstructed from the experimental measurements and tests were computationally reproduced for the healthy and herniated cases. Simulations were compared and validated with the in vivo behavior and results were given along the abdominal wall in terms of displacements, stresses and strain. Mechanical characterization of the meshes revealed Surgipro TM as the most rigid implant and Neomesh SuperSoft® as the softer, while other two meshes (Neomesh Soft® Neopore®) remained in between. These two meshes were employed in the experimental study and resulted in similar effect in the abdominal wall cavity and both were close to the healthy case. Simulations confirmed this result while showed potential objections in the case of the other two meshes, due to high values in stresses or elongation that may led to discomfort in real tissue. The use of this methodology on human surgery may provide the surgeons with reliable and useful information to avoid certain meshes on specific-patient treatment.
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Short and long-term biomechanical and morphological study of a new suture types in abdominal wall closure

  • Simón Allué, Raquel
  • Pérez López, Paloma
  • Sotomayor Núñez, Sandra
  • Peña Baquedano, Estefanía
  • Pascual González, María Gemma|||0000-0002-1623-4384
  • Bellón Caneiro, Juan Manuel|||0000-0002-6071-5011
  • Calvo Calzada, Begoña
11 p., To perform an abdominal-wall closure, a continuous suture is the preferred method. The suture materials that are most commonly employed in abdominal surgery are polypropylene and polydioxanone. However, in recent times, new products have been marketed, such as non-absorbable polyurethane with elastic properties (Assuplus®, Assut Europe, Italy) and absorbable barbed polydioxanone (Filbloc®, Assut Europe, Italy). The purpose of this study was to compare the ability of those against the standard polypropylene (SurgiproTM, Covidien, USA) and polydioxanone (Assufil®, Assut Europe, Italy) to mimic the biomechanical behavior of the abdominal wall closure. Comparison of the sutures was made first with the materials alone and later in a laparotomy closure of a rabbit abdomen, used as an animal model. The biomechanical analysis consisted of uniaxial tensile tests of threads and sutured samples of the animal abdomen. In the latter case, results were analyzed at short- (21 days) and long- (180 days) term intervals after the surgery. The morphology studies and collagen expression of the samples were also investigated. The results determined that polydioxanone and polypropylene sutures showed a linear elastic behavior, with barbed polydioxanone as the most compliant suture and polyurethane as the stiffest. The sutured samples showed a statistically significant loss of resistance, measured as the load needed to perform a certain stretch, when compared with the corresponding control tissue. Analysis of the stress?stretch curves showed that elastic polyurethane was the only suture able to reproduce the mechanical behavior of healthy tissue in the short term, while the rest of the sutures remained less stiff. This coincides with the expression of type I collagen observed in this group at this point in the study. In the long term, there was no difference among the sutures, and none was able to mimic control behavior., Ministerio de Economía y Competitividad, Instituto de Salud Carlos III