Skip to main content

EVALUACION EXPERIMENTAL DE VIGAS CONTINUAS PRETENSADAS, CON Y SIN REFUERZO, Y PIEZAS COMPUESTAS DE DOS HORMIGONES, PARA LA EXTENSION DE SU VIDA UTIL.

BES-2016-078010

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Formación
Call Contratos Predoctorales
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of the shear strength mechanism of slender precast concrete beams with cast-in-place slab and web reinforcement

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Precast concrete beams with cast-in-place slabs on top, namely concrete composite beams are frequently used for building concrete bridge decks. In designs, the contribution of cast-in-place slabs to shear strength tends to be omitted. However, given the vast number of existent bridges with this deck typology, significant cost savings could be made when assessing these structures if the slab's shear strength is considered. This paper analyses how cast-in-place slab influences the shear behaviour of concrete composite beams with web reinforcement. For this purpose, an experimental programme of 18 concrete specimens with web reinforcement and rectangular crosssections was run, in which the following parameters varied: cross-sectional depth; existence of an interface between concretes; compressive strengths of the concrete of beams and slabs; differential shrinkage between concretes. It was observed that: the slab contributed to resist shear; the existence of an interface between concretes led to a crack appearing along it that caused the transmitted shear to be divided into two load paths: one through the precast beam and another one through the slab; the slab's concrete strength was that which mainly influenced the element's shear strength; differential shrinkage did not reduce shear strength. Based on experimental observations, a mechanical model is proposed in this paper to assess the composite elements' shear strength, which considers the yielding of both stirrups and the slab's longitudinal reinforcement to be a failure criterion, which well predicted the experimental results. The shear formulations of Eurocode 2, the Level III Approximation of Model Code 2010 and the (b) Formula of ACI 318-19 offered a similar result to the herein proposed method when using the entire composite element effective depth and the weighted average of the concrete strengths of both the beam and slab estimated from the area ratio. Codes significantly underestimated specimens' interface shear., The experimental programme of this research work was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain) with concrete supplied by Caplansa. The project was supported by the Spanish Min-istry of Science and Innovation through Projects BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR; the Regional Government of Valencia through Project AICO/2018/250; the European Union with FEDER funds. The authors thank the Spanish Ministry of Economy and Business for Grant BES-2016-078010 that supported Lisbel Rueda-Garcia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Tesis doctoral (DoctoralThesis)

Experimental Assessment of the Shear Resistant Behaviour of Precast Concrete Beams with Top Cast-in-Place Concrete Slab

  • Rueda-García, Lisbel|||0000-0002-2061-1656
[ES] La construcción con elementos prefabricados de hormigón es un sector en alza por la aceleración del proceso constructivo, el ahorro de costes derivados de la obra in situ y la mejora de la calidad y acabados, entre otros. En la construcción prefabricada de estructuras de ingeniería civil como puentes y edificios es frecuente el empleo de vigas prefabricadas de hormigón. La construcción con estas vigas requiere el vertido de una capa de hormigón in situ sobre las mismas tras su emplazamiento, que sirve como elemento integrador para garantizar la unidad estructural. Los elementos estructurales que se obtienen de esta forma son conocidos como vigas compuestas de hormigón. En vigas compuestas, aspectos como la resistencia a rasante de la interfaz entre hormigones han sido estudiados en numerosas publicaciones. No obstante, su comportamiento a cortante no ha sido, por el momento, analizado en profundidad. En consecuencia, existe muy poca información, tanto en la literatura existente como en los códigos de diseño actuales, acerca de la resistencia a cortante de estos elementos, de cómo influye la presencia de una interfaz entre los hormigones en la resistencia a cortante o de cómo contribuye la losa hormigonada in situ a dicha resistencia. La presente tesis doctoral tiene como objetivo estudiar la resistencia a cortante de vigas compuestas de hormigón. Para ello, se desarrolla un extenso programa experimental compuesto por vigas monolíticas y compuestas con y sin armadura transversal, con sección transversal rectangular o en forma de T y con hormigones de diferentes calidades en la viga prefabricada y en la losa hormigonada in situ. Se ensaya a cortante un total de 69 vigas de hormigón armado con el fin de analizar las diferentes variables de interés en la resistencia a cortante. A partir de los resultados experimentales, se propone un modelo mecánico de predicción de la resistencia a cortante de vigas compuestas de hormigón con sección transversal rectangular y en forma de T, que también es de aplicación a vigas monolíticas en T. Además, como apoyo al estudio experimental y al modelo mecánico, se modelan numéricamente algunos especímenes del programa experimental. Con todo ello, se busca incrementar el estado actual del conocimiento en este campo, mediante el aporte de un gran número de resultados experimentales y el análisis de los parámetros de diseño, así como sentar las bases para el desarrollo de una formulación de diseño de estructuras compuestas y de evaluación de las ya existentes globalmente aceptada por la comunidad científica., [CA] La construcció amb elements prefabricats de formigó és un sector en alça per l'acceleració del procés constructiu, l'estalvi de costos derivats de l'obra in situ i la millora de la qualitat i acabats, entre altres. En la construcció prefabricada d'estructures d'enginyeria civil com a ponts i edificis és freqüent l'ús de bigues prefabricades de formigó. La construcció amb aquestes bigues requereix l'abocament d'una capa de formigó in situ sobre les bigues després del seu emplaçament, que serveix com a element integrador per a garantir la unitat estructural. Els elements estructurals que s'obtenen d'aquesta forma són coneguts com a bigues compostes de formigó. En bigues compostes, aspectes com la resistència a rasant de la interfície entre formigons han sigut estudiats en nombroses publicacions. No obstant això, el seu comportament a tallant no ha sigut, de moment, analitzat en profunditat. En conseqüència, existeix molt poca informació, tant en la literatura existent com en els codis de disseny actuals, sobre la resistència a tallant d'aquests elements, de com influeix la presència d'una interfície entre els formigons en la resistència a tallant o de com contribueix la llosa formigonada in situ a aquesta resistència. La present tesi doctoral té com a objectiu estudiar la resistència a tallant de bigues compostes de formigó. Per a això, es desenvolupa un extens programa experimental compost per bigues monolítiques i compostes amb armadura transversal i sense, amb secció transversal rectangular o en forma de T i amb formigons de diferents qualitats en la biga prefabricada i en la llosa formigonada in situ. S'assaja a tallant un total de 69 bigues de formigó armat amb la finalitat d'analitzar les diferents variables d'interés en la resistència a tallant. A partir dels resultats experimentals, es proposa un model mecànic de predicció de la resistència a tallant de bigues compostes de formigó amb secció transversal rectangular i en forma de T, que també és aplicable a bigues monolítiques en T. A més, com a suport a l'estudi experimental i al model mecànic, es modelen numèricament alguns espècimens del programa experimental. Amb tot això, es pretén incrementar l'estat actual del coneixement en aquest camp, mitjançant l'aportació d'un gran nombre de resultats experimentals i l'anàlisi dels paràmetres de disseny, així com establir les bases per al desenvolupament d'una formulació de disseny d'estructures compostes i d'avaluació de les ja existents globalment acceptada per la comunitat científica., [EN] Construction with precast concrete elements is a booming sector due to the acceleration of the construction process, the saving of costs arising from the on-site construction and the quality and finish improvement, among others. Precast concrete beams are frequently used in the precast construction of civil engineering structures such as bridges and buildings. Construction with these beams requires the pouring of a cast-in-place concrete layer on top of the beams after their placement, which works as a unifying element to ensure structural integrity. Structural elements obtained in this way are known as concrete composite beams. In composite beams, some aspects such as the shear strength of the interface between concretes have been studied in multiple publications. However, their shear behaviour has not yet been analysed in depth. Consequently, there is very little information, both in the existing literature and in current design codes, about the shear strength of these elements, how the presence of an interface between the concretes influences the shear strength or how the cast-in-place concrete slab contributes to the shear strength. The aim of this doctoral thesis is to study the shear strength of concrete composite beams. For this purpose, an extensive experimental programme is developed, consisting of monolithic and composite beams with and without transverse reinforcement, with rectangular or T-shaped cross-section and with concretes of different qualities in the precast beam and in the slab. A total of 69 reinforced concrete beams are tested under shear forces in order to analyse the different variables of interest in shear strength. Based on the experimental results, a mechanical model for predicting the shear strength of concrete composite beams with rectangular and T-shaped cross-section is proposed, which is also applicable to monolithic T-beams. In addition, to support the experimental study and the mechanical model, some specimens of the experimental programme are numerically modelled. All in all, the aim is to improve the current state of knowledge in this field by providing a large number of experimental results and analysing the design parameters, as well as to lay the foundations for the development of a formulation for the design of existing structures and the assessment of existing ones that is globally accepted by the scientific community., The present doctoral thesis would not have been possible without the financial support of the Ministerio de Ciencia e Innovación (MCIN) and the Agencia Estatal de Investigación (AEI) through Grants BIA2015-64672-C4-4-R and RTI2018- 099091-B-C21-AR, both funded by MCIN/AEI/10.13039/501100011033 and by the “ERDF A way of making Europe”. I am thankful as well for their support through Grant BES-2016-078010 funded by MCIN/AEI/10.13039/501100011033 and by the “ESF Investing in your future”. The project was also supported by the Regional Government of Valencia through Project AICO/2018/250. And finally, thanks to the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politècnica de València (UPV; Spain) in which this research project has been developed, and to our concrete supplier Caplansa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Safety Assessment of Shear Strength Current Formulations for Composite Concrete Beams without Web Reinforcement

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Construction with precast concrete elements without web reinforcement and cast-in-place concrete on them to enhance the overall structure's integrity is a widespread practice in building construction. However as these composite elements' vertical shear strength has not been studied in-depth, a clear criterion about cast-in-place concrete's contribution to shear resistance is still a pending matter. The present study intends to reach practical conclusions about the shear strength assessment of composite concrete elements without web reinforcement. To do so, the shear strengths of 36 specimens, provided by existing shear formulations, were compared: 19 specimens tested by the authors, in which the existence of an interface between concretes, the cross-sectional shape and the concrete compressive strengths of the beam and slab were studied; and 17 specimens taken from a previous study about composite elements by Kim et al. (2016). The applied shear formulations were those of EC2-04, Draft 7 of EC2-20, fib MC-10, ACI 318-19 and the model proposed by Kim et al. (2016). Firstly, specimens' shear strength was calculated by considering that only the beam resisted shear. Secondly according to ACI 318-19 indications about assessing composite elements¿ shear strength, the entire composite element's effective depth was used considering the lower of the compressive strengths of the beam's and slab's concretes and the weighted average of the compressive strengths. Additionally,the entire effective depth and the beam's concrete compressive strength were used. Codes formulations were more precise when estimating the monolithic specimens' shear strengths than those of composites. Therefore, the development of an adapted methodology to assess these elements¿ shear strengths is needed. EC2-20 obtained the most accurate results and gave quite good estimations for composite elements when the entire effective depth and weighted average of the concretes compressive strengths were considered., This study forms part of the research conducted at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politècnica de València (UPV, Spain) with concrete supplied by Caplansa. The project has been supported by the Spanish Ministry of Science and Innovation through Projects BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR; the Regional Government of Valencia through Project AICO/2018/250, and the European Union with FEDER funds. The authors thank the Spanish Ministry of Economy and Business for Grant BES-2016-078010.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental analysis of the shear resistance of precast concrete T-beams with a top cast-in-place slab

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Precast concrete T-beams with a cast-in-place slab on top are structural elements that are often employed in composite construction. Despite their widespread use, some aspects of their structural behaviour upon shear forces have not yet been studied in depth. Six composite specimens with different T-shaped cross-sections and concrete qualities, and with web reinforcement, were tested to analyse the shear transfer mechanisms and to assess the contribution of the cast-in-place slab to shear strength. The shear strength mechanisms deriving from experimental observations and measurements are provided. This study indicates that: placing a concrete cast-in-place slab on top of a prefabricated T-beam increases its shear strength; interface shear strength plays an essential role in concrete composite elements¿ vertical shear strength; widening the cast-in-place slab width does not increase shear strength in this test programme specimens; the compressive strength of the precast beam¿s concrete significantly influences composite beams¿ shear resistances. The ACI 318-19 formulation best captures the influence of concrete strength on shear strength of the three formulations considered (EC2, MC-10 (Level III) and ACI 318-19). However, all of them tend to underestimate shear strengths compared to the experimental results., Ministerio de Ciencia e Innovacion (MCIN) and Agencia Estatal de Investigacion (AEI) supported the present research work through grants BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR, both funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe". Author Lisbel Rueda-Garcia was supported by grant BES -2016-078010 funded by MCIN/AEI/10.13039/501100011033 and by "ESF Investing in your future". The project was also carried out with the support of the Regional Government of Valencia through Project AICO/2018/250. The open access charge was funded by CRUE- Universitat Politecnica de Valencia. This research work was under- taken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politecnica de Valencia (UPV; Spain) with concrete supplied by Caplansa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental analysis of the shear strength of composite concrete beams without web reinforcement

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] Composite concrete members without web reinforcement are often used in precast construction. The contribution of the cast-in-place concrete topping slab to vertical shear strength has been traditionally disregarded. However, significant cost savings can result from designing and assessing these structures if this contribution is considered. This paper presents the experimental study of a series of 21 monolithic and composite (precast beam and cast-in-place slab) specimens without web reinforcement, and with rectangular and T-shaped cross-sections, failing in shear. The vertical shear strength was analysed by the following test variables: cross-section shape, the existence of an interface between different aged concretes, strengths of the two concretes and the differential shrinkage effect. From these experimental tests, it was concluded that the slab contributed to shear strength, the use of high-strength concrete slightly increased specimens' shear strength and the differential shrinkage did not reduce shear strength. Specimens' failure modes were analysed based on their shear transfer mechanisms, noticing that the arching action in the slab was considerable after critical shear crack formation. The vertical shear strength experimental results were well predicted by the codes' formulations (Eurocode 2, Model Code 2010 and ACI 318-19) when composite beam depth was taken for the calculations instead of beam depth. Codes significantly underestimated the horizontal shear strengths of the composite specimens., This research has been supported by: the Spanish Ministry of Science and Innovation through Research Project BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR; the Regional Government of Valencia through Project AICO/2018/250; the European Union with FEDER funds. The experimental programme was developed in the Laboratory of Concrete of the Institute of Concrete Science and Technology (ICITECH) of the Universitat Politècnica de València (UPV) with concrete supplied by Caplansa. The Spanish Ministry of Science and Innovation supported Lisbel Rueda through grant BES-2016-078010.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental study on the shear strength of reinforced concrete composite T-shaped beams with web reinforcement

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] The current increasing use of precast concrete elements and cast-in-place concrete slabs, namely concrete composite elements, in construction requires a better understanding of their behaviour in shear. In this work, 19 T-shaped composite and monolithic specimens failing in shear were experimentally tested. Their results were compared to study the influence on the shear strength of: the flange width, the presence of an interface between concretes and the strength of the concretes of both beam and slab. The shear transfer mechanisms were analysed by adapting to these specimens a mechanical model previously proposed by the authors for rectangular composite beams. It was concluded that: the composite specimens¿ shear strength did not increase with widening flange width when the specimens showed an extended interface cracking, but increased when their crack pattern was similar to that of the monolithic specimens; the presence of an interface decreased the shear strength; the slab¿s concrete compressive strength modified the composite specimens¿ shear strength when the slab failed in shear, but not when the slab failed in bending or when the interface failed. The shear formulations of EC2, MC-10 Level III and ACI 318-19 gave good estimations when using the weighted average of the compressive strengths of the beam and slab concretes, similarly to those obtained with the proposed model. From the experimental results, the improvement of the interface shear strength of composite beams is proposed as a practical recommendation for increasing their shear strength. At the same time, the slab width and the slab¿s concrete strength could be increased with the same purpose. This work experimental findings and the adaptation of the mechanical model to T-shaped beams lay the groundwork for a future development of a shear design and assessment formulation for concrete composite elements., The authors would like to thank the Ministerio de Ciencia e Innovación (MCIN) and the Agencia Estatal de Investigación (AEI) for their support through grants BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR, both funded by MCIN/AEI/ 10.13039/ 501100011033 and by ¿ERDF A way of making Europe¿. Author Lisbel Rueda-García was supported through grant BES-2016-078010 funded by MCIN/AEI/ 10.13039/501100011033 and by ¿ESF Investing in your future¿. The Regional Government of Valencia also supported this research through Project AICO/2018/250. This research work was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politècnica de València (UPV; Spain) with concrete supplied by Caplansa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

  • Pereiro-Barceló, Javier
  • Ciurana-Tatay, Álvaro
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
[EN] Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers., This paper forms part of a line of research carried out at the University Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank the Spanish Ministry of Science and Innovation for the support provided through Projects BIA2012-32645 and RTI2018-099091-B-C21-AR, and Grant BES-2016-078010 from the European Union for the financial support with FEDER funds, and the Spanish Ministry of Education, Culture and Sport for Grant FPU12/01451.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Towards the Development of a Formulation for Obtaining the Shear Strength of Concrete Composite Beams, Hacia el desarrollo de una formulación para la obtención de la resistencia a cortante de vigas compuestas de hormigón

  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
[EN] In the design and assessment of precast concrete beams with a slab cast on top, namely concrete composite beams, engineers still face in practice unsolved shear-related issues, such as the contribution to shear strength of the slab, the concrete strength to be considered in shear formulations or the influence of the interface between concretes in the shear behaviour. In the present research, 69 shear tests were performed on monolithic and composite beams, with rectangular or T-shaped cross-section, with or without transverse reinforcement and with different concrete qualities, to experimentally analyse the issues mentioned above. The study of the shear transfer mechanisms at failure led to formulating a model for explaining the observed results. Based on this model, a shear strength predictive formulation for concrete composite beams with web reinforcement has been developed, which has been verified with the experimental results from this research and 24 additional tests from the literature. This formulation provides accurate predictions compared to the shear strength formulations of current codes EC2, MC-10 and ACI 318-19. The proposed model lays the foundations for the future development of a user-friendly formulation for calculating the shear strength of concrete composite beams., [ES] En el diseño y evaluación de vigas prefabricadas de hormigón con una losa superior hormigonada in situ, es decir, vigas compuestas de hormigón, los ingenieros siguen enfrentándose en la práctica a problemas no resueltos relacionados con el cortante, como la contribución de la losa a la resistencia a cortante, la resistencia del hormigón que se ha de considerar en las formulaciones de cortante o la influencia de la interfaz entre hormigones en el comportamiento a cortante. En la presente investigación se han realizado 69 ensayos a cortante en vigas monolíticas y compuestas, de sección rectangular o en T, con o sin armadura transversal y con diferentes calidades de los hormigones, para analizar experimentalmente las cuestiones mencionadas anteriormente. El estudio de los mecanismos de transferencia de cortante condujo a la formulación de un modelo para explicar los resultados observados. A partir de este modelo, se ha desarrollado una formulación para predecir la resistencia a cortante en vigas compuestas de hormigón con armadura de cortante, la cual se ha verificado con los resultados experimentales de esta investigación y 24 ensayos adicionales de la literatura. Esta formulación proporciona resultados precisos comparados con las formulaciones de resistencia a cortante de los códigos actuales EC2, MC-10 y ACI 318-19. El modelo propuesto sienta las bases para el futuro desarrollo de una formulación fácil de usar para el cálculo de la resistencia a cortante de vigas compuestas de hormigón., Ministerio de Ciencia e Innovación (MCIN) and Agencia Estatal de Investigación (AEI) supported the present research work through grants BIA2015-64672-C4-4-R and RTI2018-099091-B-C21-AR, both funded by MCIN/ AEI/ 10.13039/501100011033 and by ERDF A way of making Europe . Author Lisbel Rueda-García was supported by grant BES-2016-078010 funded by MCIN/AEI/ 10.13039/501100011033 and by ESF Investing in your future . The project was also carried out with the support of the Regional Government of Valencia through Project AICO/2018/250. This research work was undertaken at the Concrete Science and Technology University Institute (ICITECH) of the Universitat Politècnica de València (UPV; Spain) with concrete supplied by Caplansa.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Cyclic response of precast column-to-foundation connection using UHPC and Ni-Ti SMA reinforcements in columns

  • Pereiro-Barceló, Javier
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Rueda-García, Lisbel|||0000-0002-2061-1656
  • Albiol Ibáñez, José Ramón|||0000-0003-3049-9693
[EN] Earthquakes are catastrophic natural events with a special impact on reinforced concrete structures due to the horizontal loads that they introduce into structures. To adequately resist an earthquake, a precast structure must have a high deformation capacity, dissipate energy in each earthquake cycle, undergo less damage and fewer residual deformations. To achieve all this, the behaviour of precast columns made with UPHC was herein experimentally analysed. Steel rebars were replaced with Ni-Ti shape memory alloy (SMA) bars with super elasticity (SE) in the critical zone of the column-to-foundation connection. The Ni-Ti SMA bars crossed the interface between the column and foundation. Two types of connection with the foundation were studied: smooth pocket type and protruding bar type. Columns were subjected to constant compression and a cyclic lateral load. Rocking behaviour was observed at the connection critical section. The use of advanced materials allowed a moment-rotation behaviour of the connection to be developed without any significant damage. Low residual deformations were observed while testing because of both the damage in UHPC was low and the superelasticity of the Ni-Ti SMA bars., This paper forms part of a research line carried out at the Institute of Concrete Science and Technology (ICITECH) of the Universitat Politecnica de Valencia. The authors wish to thank to the Government of Spain Ministry of Economy and Competitiveness for the support it pro-vided through Project BIA2012-32645, to the Government of Spain Ministry of Science and Innovation for the project RTI2018-099091-B-C21-AR, and the grant BES-2016-078010, to the European Union for the financial support with FEDER funds and to the Government of Spain Ministry of Education, Culture and Sports for grant FPU12/01451.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Behaviour of retrofited precast UHPC and Ni-Ti SMA column-to-foundation connection with CFRP wrapping layers

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Rueda-García, Lisbel
  • Ciurana-Tatay, Álvaro
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed and were retested under the same loads (second-stage tests). The columns were originally manufactured with ultrahigh-performance concrete (UHPC) with high stee-fibre content (volumetric steel/fibre ratio 1.9%). The steel bars in the connection were replaced with superelastic Ni-Ti SMA bars that crossed the column/foundation interface. Two types of connection between the precast column and the foundation were analysed: protruding bars and smooth pocket bars (SP). The specimens were subjected to the same constant level of relative axial load in both the first and second-stage tests. The objective was to determine whether the initial performance of precast UHPC and SMA reinforced column-to-foundation connections against lateral cyclic loads can be restored after a seismic event by means of simple and economic retrofitting. The effectiveness of the number of strengthening CFRP layers was also studied (two or three CFRP wrapping layers) for each column-to-foundation connection type. The main results for PB and SP connection specimens with respect to the original specimens were respectively: an average strength capacity loss of 8% and 19%, displacement ductility increase of 8% and 42%, dissipated energy 48% and 53% higher and initial stiffness 9.5% and 21% lower. No significant differences were observed in the repairs done with two or three CFRP wrapping layers.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Cyclic response of precast column-to-foundation connection using uhpc and Ni–Ti SMA reinforcements in columns

  • Pereiro-Barceló, Javier
  • Bonet, José L.
  • Rueda-García, Lisbel
  • Albiol-Ibáñez, José Ramón
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
Earthquakes are catastrophic natural events with a special impact on reinforced concrete structures due to the horizontal loads that they introduce into structures. To adequately resist an earthquake, a precast structure must have a high deformation capacity, dissipate energy in each earthquake cycle, undergo less damage and fewer residual deformations. To achieve all this, the behaviour of precast columns made with UPHC was herein experimentally analysed. Steel rebars were replaced with Nisingle bondTi shape memory alloy (SMA) bars with superelasticity (SE) in the critical zone of the column-to-foundation connection. The Nisingle bondTi SMA bars crossed the interface between the column and foundation. Two types of connection with the foundation were studied: smooth pocket type and protruding bar type. Columns were subjected to constant compression and a cyclic lateral load. Rocking behaviour was observed at the connection critical section. The use of advanced materials allowed a moment-rotation behaviour of the connection to be developed without any significant damage. Low residual deformations were observed while testing because of both the damage in UHPC was low and the superelasticity of the Nisingle bondTi SMA bars.