Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Cm-factor for RC slender columns under unequal eccentricities and skew angle loads at the ends

  • Da Costa Lino Leite, Luiz Carlos
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
Reinforced concrete slender columns, in general, are subjected to a non-uniform bending moment law, due to the occurrence of unequal eccentricities and skew angles at the ends. Design codes suggest calculating an equivalent moment factor Cm in each bending direction with the aim of reducing the analysis of the column to another equivalent one with equal eccentricities and angles at the ends. This paper presents a new equation to compute the equivalent moment factor Cm derived from the numerical model. This model has been calibrated and checked with 255 experimental tests from the literature. The experiments correspond to RC slender columns, pinned pinned and subjected to short-term ultimate loads and unequal eccentricities at the ends, for both uniaxial bending and biaxial bending. In HSC slender columns, a factor k3 is proposed to be applied along the concrete cover region in order to take into account the concrete cover spalling off. From the comparison with the current formula of the design codes (ACI-318 and Eurocode 2), the proposed Cm increases the safety factor for low and medium slenderness of the column (&#955;g < 20), low levels of axial load (N/Ncr < 0.50), high-strength concrete (50 < fc < 100 MPa) and double curvature bending (&#946; < 0). The proposed formula allows reinforced concrete slender columns to be both checked and designed with enough accuracy for practice engineering, and is simple to apply., The content of this article is part of a research work carried out by the Universitat Politecnica de Valencia and the Institute of Concrete Science and Technology (ICITECH). The authors of this work wish to thank the Research Bureau of the Spanish Ministry of Economy and Competitivenes, the Plan E and the European Regional Development Fund for the co-funding of the research projects BIA2006-06429 and BIA BIA-2012-32645.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Behavior of RC columns under unequal eccentricititess and skew angle loads at ends

  • Da Costa Lino Leite, Luiz Carlos
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
In the design of slender concrete columns, such as civil or architecture constructions, biaxial compression loads with unequal eccentricities and skew angles at both ends is a common situation. However, in the literature, there is a lack of experimental data subjected to this type of load both casted with normal and high strength concrete. The scarcity of experimental results prevent from calibrating numerical models and contrasting the reliability of the simplified approaches proposed in the Standards. In this paper, 36 slender columns subjected to biaxial compression with unequal eccentricities and skew angles at the ends. The following parameters have been considered in this research: concrete strength, eccentricities ratios at both ends, eccentricity value, and the combination of different skew angles. Ultimate strength and deformed shape of the columns have been analyzed. Simplified approaches proposed by EC-2(2004) and ACI-318(11) have been compared with the experimental data and conservative results have been reached with different accuracy depending on the studied parameters. Less accurate results are obtained for high strength concrete., This work is enclosed in a research project on slender columns carried out by Instituto de Ciencia y Tecnologia del Hormigon (ICI-TECH) of the Universitat Polittcnica de Valencia. This research was funded through grants from the Ministerio de Ciencia y Innovacion de Espana with research projects BIA 2006-06429 and European Funds of Regional Development. The experimental program was developed in the Laboratory of Concrete of the Construction Engineering Department of the Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental research on high strength concrete slender columns subjected to compression and uniaxial bending with unequal eccentricities at the ends

  • Leite, L.
  • Bonet Senach, José Luís|||0000-0002-6687-5307
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Fernández Prada, Miguel Ángel|||0000-0001-5527-7793
This paper presents an experimental research on 32 columns tested with unequal eccentricities at the ends. The purpose of this research is twofold: first, the contribution to the knowledge of these components and second, to calibrate and check simplified approaches. The analyzed variables are: the concrete strength (normal and high strength), the slenderness, the amount of longitudinal reinforcement, the ratio between eccentricities at the ends and the relative eccentricity applied. Ultimate strength and deformed shape of the column have been analyzed and simplified approaches proposed by EC-2 (2004) and by ACI- 318 (2008) have been compared with experimental results. In general, the accuracy of the simplified methods proposed in the EC-2 (2004) and the ACI-318 (08), for HSC columns is lower than for NSC columns. Ductility factor (lD) according to (EC-8 (2005)) has been assessed among the experimental tests in order to compare the displacement capacity. In general, ductility increases when the relative eccentricity (e2/b), the ratio between eccentricities (b), and the amount of longitudinal reinforcement (ql) increase, and when the slenderness of the column (kg) and the concrete strength (fc) decreases., This work is enclosed in a research project on slender columns carried out by Instituto de Ciencia y Tecnologia del Hormigon (ICI-TECH) of the Universitat Politecnica de Valencia. This research was funded through grants from the Ministerio de Ciencia y Innovacion de Espana with research projects BIA 2006-06429. The experimental program was developed in the Laboratory of Concrete of the Construction Engineering Department of the Universitat Politecnica de Valencia.