Skip to main content

CERRAMIENTOS NO CONVENCIONALES PARA LA PROTECCION DE EDIFICACIONES E INFRAESTRUCTURAS CRITICAS: ATENUACION DE LOS EFECTOS DE ACCIONES SISMICAS Y EXPLOSIONES

BIA2015-70651-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Dirección General de Investigación Científica y Técnica
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Monotonic shear strength of headed studs in reinforced infill walls

  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Pallarés Rubio, Francisco Javier|||0000-0003-4298-2287
  • Aguero Ramón Llin, Antonio|||0000-0002-7046-3014
  • Ramada, José R.
  • Eatherton, Matthew R.
[EN] Headed studs are key components of structures which facilitate composite behavior between steel and concrete elements. In steel building structures, reinforced concrete infill walls surrounded by a stiff steel frame is a common example of a composite structure used to resist horizontal loads such as those produced by earthquakes or wind. To this end, these types of concrete walls need to be anchored to the steel frame with headed studs which must withstand shear and tensile forces (AISC 360). To properly design headed stud anchors in concrete walls, it is first necessary to understand their behavior when subjected to monotonic shear forces considering edge conditions and reinforcing details that may influence the stud strength. Few tests have examined headed studs subjected to monotonic shear with typical boundary effects in reinforced infill walls, so a new experimental study on 17 specimens explores the behavior of headed studs exposed to monotonic shear loading with group effects. The experiments showed that the strength of studs installed in infill walls with edge conditions is well predicted (average error in prediction is smaller than 10%) by ACI 318, AISC 360 and EC-4. However, when group effects of anchors are included in the analysis of infill walls, only the ACI 318 is able to predict the behavior., The present study was funded by the Universitat Politecnica de Valencia (UPV) and the Spanish Ministry of Economy and Competitiveness through the Project BIA2015-70651-R. The authors would like to express their gratitude to Debra Westall for revising the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental and analytical assessment of the influence of masonry façade infills on seismic behavior of RC frame buildings

  • Pallarés Rubio, Francisco Javier|||0000-0003-4298-2287
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Davia, Antonio
  • Hassan, Wael M.
[EN] On May 11, 2011 at 6:47p.m., an M5.1 earthquake took place in Lorca at a depth of 4 km, in the Region of Murcia, south of Spain, which resulted in nine fatalities and 324 injuries and major built environment damage. Approximately 80% of the residential buildings were affected with various degrees of damage, 5% with severe structural damage and 13% with moderate structural damage, in addition to the damage of infrastructure and public buildings. Reconnaissance and expert analyses revealed that one of the main causes of damage during the Lorca earthquake was the interaction between the non-structural elements and the seismic-resisting framing of the buildings. Studies on this interaction, that started in the 1950 s, led to the development of a wide range of macro-models that simulate the stiffness of the masonry infills using one or more equivalent diagonal strut(s). Following an extensive literature review, 12 mathematical expressions have been compiled to estimate the horizontal stiffness of the equivalent strut that simulates the behavior of masonry infills that make up a typical fa?ade of many modern buildings. Two full-scale tests under horizontal cyclic displacement reversals have been carried out on two 5x3m concrete frames: one frame with masonry infill simulating a regular fa?ade; and the other is a bare control frame. The comparison of both tests enabled quantifying the stiffness contribution of the fa?ade infill and identifying the simplified expression that best fits the horizontal stiffness. Using this expression, a realistic seismic design of a prototype building in Lorca, Spain, is conducted under the typical assumption of most modern building codes to consider masonry infills as non-structural elements, and consequently the designed building was seismically assessed considering the influence of the infills. Results of the assessment are in accordance with the real damage patterns observed during the Lorca earthquake reconnaissance., The present study was supported by the Universitat Politecnica de Valencia (UPV) and the Spanish Ministry of Economy and Competitiveness through Project BIA201570651R, the Ministry of Science, Innovation and Universities through Project FPU16/0354, and Generalitat Valenciana (GVA) by BEST2018.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental study on the response of seismically isolated masonry infilled steel frames during the initial stages of a seismic movement

  • Pallarés Rubio, Francisco Javier|||0000-0003-4298-2287
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
[EN] A novel seismic isolator is presented to detach the structural behavior from the infill effect during earth movements, with the aim of avoiding strong interactions. An experimental campaign was carried out to determine the influence of this isolator during the early stages of the seismic response of masonry-infilled steel frames, testing different configuration schemes to assess their effectiveness in terms of overall isolation, reduction of peak loads, strain levels and energy dissipation. The device was found to hinder the formation of the damaging diagonal compression struts by absorbing the relative displacements between frame and infill. The results achieved show that seismic interaction between infill panels and the structural skeleton can be faced from an isolation point of view., Authors want to express their gratitude to the Ministerio de Economía y Competitividad from Spain (Spanish Ministry of Economy and Competitiveness) and FEDER from European Commission for providing the financial support that made possible this study through the research projects BIA2012-35186 and BIA2015-70651-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Resilient structures in the seismic retrofitting of RC frames: A case study

  • Pallarés Rubio, Francisco Javier|||0000-0003-4298-2287
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Domínguez, David
[EN] It is very important to allocate valuable resources efficiently when reconstructing buildings after earthquake damage. This paper proposes the use of a simple seismic retrofitting system to make buildings more resilient than the stiffer systems such as the shear walls implemented in Chile after the earthquake in 2010. The proposal is based on the use of steel chevron-type braces in RC buildings as a dual system to improve the seismic performance of multistory buildings. A case study was carried out to compare the proposal with the shear wall solution for the typical seismic Chilean RC building from the structural and economic perspectives. The results show that it is more resilient than other stiffer seismic solutions, such as shear walls, reduces the demand, minimizes seismic damage, gives reliable earthquake protection and facilitates future upgrades and repairs while achieving the level of immediate occupancy without the costs of the shear walls system., The authors wish to thank the Universitat Politecnica de Valencia (UPV) (PAID-00-17), the Generalitat Valenciana (GVA) and the Spanish Ministry of Economy and Competitiveness (MINECO) for the grants and funds received to support this investigation: BIA2012-35186, BIA2015-70651-R, BEST/2018.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Behaviour of headed studs subjected to cyclic shear in steel frames with reinforced concrete infill walls

  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Aguero Ramón Llin, Antonio|||0000-0002-7046-3014
  • Martí Vargas, José Rocío|||0000-0003-1665-2348
  • Pallarés Rubio, Francisco Javier|||0000-0003-4298-2287
[EN] Headed studs are often used to facilitate composite actions between steel and concrete structures. In steel building structures, reinforced concrete walls are commonly used to ensure composite action to stiffen steel frames as a lateral resistance system against horizontal loads, such as earthquakes or wind. Such walls need to be anchored to the steel frame by headed studs, and these must be able to withstand shear and tension forces, as well as the interaction between these two. To design such anchors in concrete walls, it is necessary to describe experimentally their behaviour under monotonic and cyclic shear forces given that edge conditions and reinforcing details influence stud stiffness and strength. As very few experimental studies have examined headed studs subjected to monotonic or cyclic shear with usual boundary effects in steel frames with reinforced infill walls, a new experimental test setup and test results are presented herein. Four tests on headed studs were carried out to describe the behaviour of headed studs under monotonic and cyclic shear loading, as well as to validate the new test setup. This research shows that the behaviour of studs installed in infill walls without group effects are conservatively predicted by EC-4 and Makino's formula under monotonic shear loading. Furthermore, a reduction factor of 0.70 is recommended to design studs subjected to cyclic shear forces., The present study was supported by the Universitat Politecnica de Valencia (UPV) and the Spanish Ministry of Economy and Competitiveness through Project BIA2015-70651-R and Generalitat Valenciana (GVA) by BEST2018. The authors would like to express their gratitude to Debra Westall for revising the manuscript.