Skip to main content

FLEX3D: ANALISIS EN ALTO RENDIMIENTO DE LA FLEXIBILIDAD ESTRUCTURAL TANTO POR CRIO MICROSCOPIA ELECTRONICA COMO POR CRIO MICROSCOPIA DE RAYOS X BLANDOS

BIO2016-76400-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

Docta Complutense
Publication Artículo científico (JournalArticle)

Measuring local-directional resolution and local anisotropy in cryo-EM maps

  • Vilas, José Luis
  • Tagare, Hemant D.
  • Vargas Balbuena, Javier
  • Carazo, Jose María
  • Sorzano, Carlos Óscar S.
The introduction of local resolution has enormously helped the understanding of cryo-EM maps. Still, for any given pixel it is a global, aggregated value, that makes impossible the individual analysis of the contribution of the different projection directions. We introduce MonoDir, a fully automatic, parameter-free method that, starting only from the final cryo-EM map, decomposes local resolution into the different projection directions, providing a detailed level of analysis of the final map. Many applications of directional local resolution are possible, and we concentrate here on map quality and validation.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Using Scipion for stream image processing at Cryo-EM facilities

  • Gómez-Blanco, Josué
  • Rosa-Trevín, J. M. de la
  • Marabini, Roberto
  • Caño, Laura del
  • Jiménez, A.
  • Martínez, Marta
  • Melero, Roberto
  • Majtner, T.
  • Maluenda, D.
  • Mota, J.
  • Rancel, Y.
  • Ramírez-Aportela, Erney
  • Vilas, J. L.
  • Carroni, M.
  • Fleischmann, S.
  • Lindahl, E.
  • Ashton, A. W.
  • Basham, M.
  • Clare, D. K.
  • Savage, K.
  • Siebert, C. A.
  • Sharov, G. G.
  • Sorzano, Carlos Óscar S.
  • Conesa Mingo, Pablo
  • Carazo, José M.
Three dimensional electron microscopy is becoming a very data-intensive field in which vast amounts of experimental images are acquired at high speed. To manage such large-scale projects, we had previously developed a modular workflow system called Scipion (de la Rosa-Trevín et al., 2016). We present here a major extension of Scipion that allows processing of EM images while the data is being acquired. This approach helps to detect problems at early stages, saves computing time and provides users with a detailed evaluation of the data quality before the acquisition is finished. At present, Scipion has been deployed and is in production mode in seven Cryo-EM facilities throughout the world., Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400R(AEI/FEDER, UE) and AEI/FEDER BFU 2016 74868P, the Comunidad Autónoma de Madrid through Grant: S2017/BMD-3817, European Union (EU) and Horizon 2020 through grant Corbel (INFRADEV-1-2014-1, Proposal: 654248). The “Knut & Alice Wallenberg Foundation”, and “A Pilot Facility development grant from Science for Life Laboratory”. European Union (EU) and Horizon 2020 through grant EOSCpilot (INFRADEV-04-2016, Proposal: 739563).This work used the EGI Infrastructure and is co-funded by the EGIEngage project (Horizon 2020) under Grant No. 654142. European Union (EU) and Horizon 2020 through grant West-Life (EINFRA-2015-1, Proposal: 675858) European Union (EU) and Horizon 2020 through grant Elixir - EXCELERATE (INFRADEV-3-2015, Proposal: 676559) European Union (EU) and Horizon 2020 through grant iNEXT (INFRAIA-1-2014-2015, Proposal: 653706)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

DeepEMhacer: a deep learning solution for cryo-EM volume post-processing

  • Sánchez-García, Rubén
  • Gómez-Blanco, Josué
  • Cuervo, Ana
  • Carazo, José M.
  • Sorzano, Carlos Óscar S.
  • Vargas, Javier
Cryo-electron microscopy (cryo-EM) maps are among the most valuable sources of information for protein structure modeling. However, due to the loss of contrast at high frequencies, they generally need to be post-processed before modeling in order to improve their interpretability. To that end, approaches based on B-factor correction are the most popular choices, yet they suffer from some limitations such as the fact that the correction is applied globally, ignoring the presence of heterogeneity in the map local quality that cryo-EM reconstructions tend to exhibit. With the aim of overcoming these limitations, here we present DeepEMhacer, a deep learning approach designed to perform automatic post-processing of cryo-EM maps. Trained on a dataset of pairs of experimental cryo-EM maps and maps sharpened by LocScape using their respective atomic models, DeepEMhacer has automatically learned how to post-process experimental maps performing masking-like and sharpening-like operations in a single step. DeepEMhacer has been evaluated on a testing set of 20 different experimental maps, showing its ability to obtain much cleaner and detailed versions of the experimental maps, thus, improving their interpretability. Additionally, we have illustrated the benefits of DeepEMhacer with a use case in which the structure of the SARS-CoV 2 RNA polymerase is improved., This work is supported by the the Comunidad de Madrid through grant CAM (S2017/BMD-3817), the Spanish Ministry of Economy and Competitiveness (BIO2016-76400-R). J.V. acknowledges economical support from the Ramón y Cajal 2018 program (RYC2018-024087- I). R.S. is recipient of an FPU fellowship., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

FlexAlign: An Accurate and Fast Algorithm for Movie Alignment in Cryo-Electron Microscopy

  • Střelák, David
  • Filipovič, Jiří
  • Jiménez-Moreno, Amaya
  • Carazo, José M.
  • Sánchez Sorzano, Carlos Óscar
© 2020 by the authors., Cryogenic Electron Microscopy (Cryo-EM) has been established as one of the key players in Structural Biology. It can reconstruct a 3D model of the sample at the near-atomic resolution, which led to a Method of the year award by Nature, and the Nobel Prize in 2017. With the growing number of facilities, faster microscopes, and new imaging techniques, new algorithms are needed to process the so-called movies data produced by the microscopes in real-time, while preserving a high resolution and maximum of additional information. In this article, we present a new algorithm used for movie alignment, called FlexAlign. FlexAlign is able to correctly compensate for the shift produced during the movie acquisition on-the-fly, using the current generation of hardware. The algorithm performs a global and elastic local registration of the movie frames using Cross-Correlation and B-spline interpolation for high precision. We show that our execution time is compatible with real-time correction and that we preserve the high-resolution information up to high frequency., The authors would like to acknowledge financial support from: the Comunidad de Madrid through grant CAM (S2017/BMD-3817), the Spanish Ministry of Economy and Competitiveness (BIO2016-76400-R), the Instituto de Salud Carlos III, PT17/0009/0010 (ISCIII-SGEFI/ERDF) and the European Union and Horizon 2020 through grant: CORBEL (INFRADEV-01-2014-1, Proposal 654248), INSTRUCT-ULTRA (INFRADEV-03-016-2017, Proposal 731005), EOSC Life (INFRAEOSC-04-2018, Proposal: 824087) and HighResCells (ERC-2018-SyG, Proposal: 810057). The project that gave rise to these results received the support of a fellowship from “la Caixa” Foundation (ID 100010434). The fellowship code is LCF/BQ/DI18/11660021. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 713673. The work was supported from European Regional Development Fund-Project “CERIT Scientific Cloud” (No. CZ.02.1.01/0.0/0.0/16_013/0001802)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multitarget Virtual Screening for Drug Repurposing in COVID19

  • Sorzano, Carlos Óscar S.
  • Crisman, Enrique
  • Carazo, José M.
  • León, Rafael
Therapeutic or preventive research for coronavirus SARS-CoV2 is an extremely active topic of research since its outbreak in January 2020. In this paper we report the results from a virtual drug screening analysis that, to the best of our knowledge, is the widest work in terms of target proteins and compound library. Our study was focused on the repur- posing of currently commercialized drugs, and especially those that can interact with multiple viral proteins and several binding sites within each protein. Additionally, we performed a second virtual screening analysis in which we compared our results to the predicted binding a nities for the drugs currently in clinical trials. We show that the best molecules in our screening compares favourably to those in clinical trials, suggesting their suitability for therapeutic or preventive applications.Therapeutic or preventive research for coronavirus SARS-CoV2 is an extremely active topic of research since its outbreak in January 2020. In this paper we report the results from a virtual drug screening analysis that, to the best of our knowledge, is the widest work in terms of target proteins and compound library. Our study was focused on the repur- posing of currently commercialized drugs, and especially those that can interact with multiple viral proteins and several binding sites within each protein. Additionally, we performed a second virtual screening analysis in which we compared our results to the predicted binding a nities for the drugs currently in clinical trials. We show that the best molecules in our screening compares favourably to those in clinical trials, suggesting their suitability for therapeutic or preventive applications., We thank nancial support from the Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), the \Comunidad Autonoma de Madrid" through Grant: S2017/BMD-3817, Instituto de Salud Carlos III, PT17/0009/0010 (ISCIII-SGEFI/ERDF), European Union (EU) and Horizon 2020 through grants: CORBEL (INFRADEV-1-2014-1, Proposal: 654248), INSTRUCT-ULTRA (INFRADEV-03-2016-2017, Proposal: 731005), EOSC Life (INFRAEOSC-04-2018, Proposal: 824087), HighResCells (ERC- 2018-SyG, Proposal: 810057), IMpaCT (WIDESPREAD-03-2018 - Proposal: 857203), EOSC-Synergy (EINFRA-EOSC-5, Proposal: 857647), and iNEXTDiscovery (Proposal: 871037). The authors acknowledge the support and the use of resources of Instruct, a Landmark ESFRI project., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A benchmark set of highly-efficient CUDA and OpenCL kernels and its dynamic autotuning with Kernel Tuning Toolkit

  • Petrovič, Filip
  • Střelák, David
  • Hozzová, Jana
  • Ol’ha, Jaroslav
  • Trembecký, Richard
  • Benkner, Siegfried
  • Filipovič, Jiří
© 2020., In recent years, the heterogeneity of both commodity and supercomputers hardware has increased sharply. Accelerators, such as GPUs or Intel Xeon Phi co-processors, are often key to improving speed and energy efficiency of highly-parallel codes. However, due to the complexity of heterogeneous architectures, optimization of codes for a certain type of architecture as well as porting codes across different architectures, while maintaining a comparable level of performance, can be extremely challenging. Addressing the challenges associated with performance optimization and performance portability, autotuning has gained a lot of interest. Autotuning of performance-relevant source-code parameters allows to automatically tune applications without hard coding optimizations and thus helps with keeping the performance portable. In this paper, we introduce a benchmark set of ten autotunable kernels for important computational problems implemented in OpenCL or CUDA. Using our Kernel Tuning Toolkit, we show that with autotuning most of the kernels reach near-peak performance on various GPUs and outperform baseline implementations on CPUs and Xeon Phis. Our evaluation also demonstrates that autotuning is key to performance portability. In addition to offline tuning, we also introduce dynamic autotuning of code optimization parameters during application runtime. With dynamic tuning, the Kernel Tuning Toolkit enables applications to re-tune performance-critical kernels at runtime whenever needed, for example, when input data changes. Although it is generally believed that autotuning spaces tend to be too large to be searched during application runtime, we show that it is not necessarily the case when tuning spaces are designed rationally. Many of our kernels reach near peak-performance with moderately sized tuning spaces that can be searched at runtime with acceptable overhead. Finally we demonstrate, how dynamic performance tuning can be integrated into a real-world application from cryo-electron microscopy domain., The work was supported from European Regional Development Fund-Project “CERIT Scientific Cloud” (No.CZ.02.1.01/0.0/0.0/16_013/0001802). The project that gave rise to these results received the support of a fellowship from ”la Caixa” Foundation (ID 100010434). The fellowship code is LCF/BQ/DI18/11660021. This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Skodowska-Curie grant agreement No. 713673. The Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE). “Comunidad Autónoma de Madrid” through Grant: S2017/BMD-3817.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Improvements on marker-free images alignment for electron tomography

  • Sorzano, Carlos Óscar S.
  • Isidro, Federico de
  • Fernández-Giménez, Elena
  • Herreros, David
  • Marco, Sergio
  • Carazo, José M.
  • Messaoudi, C.
© 2020 The Author(s)., Electron tomography is a technique to obtain three-dimensional structural information of samples. However, the technique is limited by shifts occurring during acquisition that need to be corrected before the reconstruction process. In 2009, we proposed an approach for post-acquisition alignment of tilt series images. This approach was marker-free, based on patch tracking and integrated in free software. Here, we present improvements to the method to make it more reliable, stable and accurate. In addition, we modified the image formation model underlying the alignment procedure to include different deformations occurring during acquisition. We propose a new way to correct these computed deformations to obtain reconstructions with reduced artifacts. The new approach has demonstrated to improve the quality of the final 3D reconstruction, giving access to better defined structures for different transmission electron tomography methods: resin embedded STEM-tomography and cryo-TEM tomography. The method is freely available in TomoJ software., We thank financial support from the Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), the “Comunidad Autónoma de Madrid” through Grant: S2017/BMD-3817, Instituto de Salud Carlos III, PT17/0009/0010 (ISCIII-SGEFI/ERDF), European Union (EU) and Horizon 2020 through grants: CORBEL (INFRADEV-1–2014-1, Proposal: 654248), INSTRUCT-ULTRA (INFRADEV-03–2016-2017, Proposal: 731005), EOSC Life (INFRAEOSC-04–2018, Proposal: 824087), HighResCells (ERC-2018-SyG, Proposal: 810057), IMpaCT (WIDESPREAD-03–2018 - Proposal: 857203), EOSC-Synergy (EINFRA-EOSC-5, Proposal: 857647), and iNEXT-Discovery (Proposal: 871037). The authors acknowledge the support and the use of resources of Instruct, a Landmark ESFRI project.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Local resolution estimates of cryoEM reconstructions

  • Vilas, J. L.
  • Heymann, JB
  • Tagare, Hemant D.
  • Ramírez-Aportela, Erney
  • Carazo, José M.
  • Sorzano, Carlos Óscar S.
The field of cryoEM has quickly advanced in last years with the new biochemical, technological, methodological and computational developments. It has allowed significant progresses in Structural Biology, typically reaching quasi-atomic resolutions in the reconstructed maps. However, this rapid advance has also generated new questions relevant to resolution estimates. The global resolution metrics and their criteria have been deeply discussed in the last decade, but despite that, it remains as an important issue in the field. Recently, the introduction of local resolution measurements has changed how cryoEM reconstructions are interpreted, providing information about the existence of heterogeneity, flexibility, and angular assignment errors, and using it as a tool to aid in modeling. In this review we revisit the concept of local resolution and the different algorithms in the current state of the art. However, the concept of local resolution is not uniquely defined, and each implementation measures different features. This may lead to inappropriate interpretation of local resolution maps. Hence, a set of good practices is provided in this review to avoid misleading and over-interpretation of the reconstructions., HD Tagare and JL Vilas are supported by NIH grant R01GM114051. E Ramirez-Aportela, COS Sorzano and JM Carazo were supported by The Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), the ‘Comunidad Autónoma de Madrid’ through Grant: S2017/BMD-3817. This work was supported by the Intramural Research Program of the National Institute for Arthritis, Musculoskeletal and Skin Diseases, NIH.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Measurement of local resolution in electron tomography

  • Vilas, J. L.
  • Otón, Joaquín
  • Messaoudi, C.
  • Melero, Roberto
  • Conesa Mingo, Pablo
  • Ramírez-Aportela, Erney
  • Mota, J.
  • Martínez, Marta
  • Jiménez, A.
  • Marabini, Roberto
  • Carazo, José M.
  • Vargas, Javier
  • Sorzano, Carlos Óscar S.
Resolution (global and local) is one of the most reported metrics of quality measurement in Single Particle Analysis (SPA). However, in electron tomography, the situation is different and its computation is not straightforward. Typically, resolution estimation is global and, therefore, reduces the assessment of a whole tomogram to a single number. However, it is known that tomogram quality is spatially variant. Still, up to our knowledge, a method to estimate local quality metrics in tomography is lacking. This work introduces MonoTomo, a method developed to estimate locally in a tomogram the highest reliable frequency component, expressed as a form of local resolution. The fundamentals lie in a local analysis of the density map via monogenic signals, which, in analogy to MonoRes, allows for local estimations. Results with experimental data show that the local resolution range that MonoTomo casts agrees with reported resolution values for experimental data sets, with the advantage of providing a local estimation. A range of applications of MonoTomo are suggested for further exploration., The author would like to express their gratitude to Dr. J.J. Fernandez for his interest, following and advice on this work. The authors would like to acknowledge economical support from The Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), the “Comunidad Autónoma de Madrid” through Grant: S2017/BMD-3817, and the European Union (EU) and Horizon 2020 through grant EOSCpilot (INFRADEV-04-2016, Proposal: 739563), INSTRUCT - ULTRA (INFRADEV-03-2016-2017, Proposal: 731005), EOSC-LIFE (INFRAEOSC-04-2018, Proposal: 824087) and HighResCells (ERC-2018-SyG, Proposal: 810057). The authors acknowledge the support and the use of resources of Instruct-ERIC.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

MicrographCleaner: A python package for cryo-EM micrograph cleaning using deep learning

  • Sánchez-García, Rubén
  • Segura, Joan
  • Maluendab, D.
  • Sorzano, Carlos Óscar S.
  • Carazo, José M.
Cryo-EM Single Particle Analysis workflows require tens of thousands of high-quality particle projections to unveil the three-dimensional structure of macromolecules. Conventional methods for automatic particle picking tend to suffer from high false-positive rates, hampering the reconstruction process. One common cause of this problem is the presence of carbon and different types of high-contrast contaminations. In order to overcome this limitation, we have developed MicrographCleaner, a deep learning package designed to discriminate, in an automated fashion, between regions of micrographs which are suitable for particle picking, and those which are not. MicrographCleaner implements a U-net-like deep learning model trained on a manually curated dataset compiled from over five hundred micrographs. The benchmarking, carried out on approximately one hundred independent micrographs, shows that MicrographCleaner is a very efficient approach for micrograph preprocessing. MicrographCleaner (micrograph_cleaner_em) package is available at PyPI and Anaconda Cloud and also as a Scipion/Xmipp protocol. Source code is available at, The authors would like to acknowledge economical support from: The Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE) and the “Comunidad Autónoma de Madrid and Ministry of Education of Spain” through Grant: S2017/BMD-3817. Ruben Sanchez-Garcia is recipient of an FPU fellowship.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Re-examining the spectra of macromolecules. Current practice of spectral quasi B-factor flattening.

  • Vilas, J. L.
  • Vargas, Javier
  • Martínez, Marta
  • Ramírez-Aportela, Erney
  • Melero, Roberto
  • Jiménez-Moreno, Amaya
  • Garduño, E.
  • Conesa Mingo, Pablo
  • Marabini, Roberto
  • Maluenda, D.
  • Carazo, José M.
  • Sorzano, Carlos Óscar S.
The analysis of structure factors in 3D cryo-EM Coulomb potential maps and their “enhancement” at the end of the reconstruction process is a well-established practice, normally referred to as sharpening. The aim is to increase contrast and, in this way, to help tracing the atomic model. The most common way to accomplish this enhancement is by means of the so-called B-factor correction, which applies a global filter to boost high frequencies with some dampening considerations related to noise amplification. The results are maps with a better visual aspect and a quasiflat spectrum at medium and high frequencies. This practice is so widespread that most map depositions in the Electron Microscopy Data Base (EMDB) only contain sharpened maps. Here, the use in cryoEM of global B-factor corrections is theoretically and experimentally analyzed. Results clearly illustrate that protein spectra present a falloff. Thus, spectral quasi-flattening may produce protein spectra with distortions when compared with experimental ones, this fact, combined with the practice of reporting only sharpened maps, generates a sub-optimal situation in terms of data preservation, reuse and reproducibility. Now that the field is more advanced, we put forward two suggestions: (1) to use methods which keep more faithfully the original experimental signal properties of macromolecules when “enhancing” the map, and (2) to further stress the need to deposit the original experimental maps without any postprocessing or sharpening, not only the enhanced maps. In the absence of access to these original maps data is lost, preventing their future analysis with new methods., The authors would like to acknowledge economical support from The Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), the “Comunidad Autónoma de Madrid” through Grant: S2017/BMD-3817.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

State-dependent sequential allostery exhibited by chaperonin TRiC/CCT revealed by network analysis of Cryo-EM maps

  • Zhang, Yan
  • Krieger, James
  • Mikulska-Ruminska, Carolina
  • Kaynak, Burak
  • Sorzano, Carlos Óscar S.
  • Carazo, José M.
  • Xing, Jianhua
  • Bahar, Ivet
The eukaryotic chaperonin TRiC/CCT plays a major role in assisting the folding of many proteins through an ATP-driven allosteric cycle. Recent structures elucidated by cryo-electron microscopy provide a broad view of the conformations visited at various stages of the chaperonin cycle, including a sequential activation of its subunits in response to nucleotide binding. But we lack a thorough mechanistic understanding of the structure-based dynamics and communication properties that underlie the TRiC/CCT machinery. In this study, we present a computational methodology based on elastic network models adapted to cryo-EM density maps to gain a deeper understanding of the structure-encoded allosteric dynamics of this hexadecameric machine. We have analysed several structures of the chaperonin resolved in different states toward mapping its conformational landscape. Our study indicates that the overall architecture intrinsically favours cooperative movements that comply with the structural variabilities observed in experiments. Furthermore, the individual subunits CCT1-CCT8 exhibit state-dependent sequential events at different states of the allosteric cycle. For example, in the ATP-bound state, subunits CCT5 and CCT4 selectively initiate the lid closure motions favoured by the overall architecture; whereas in the apo form of the heteromer, the subunit CCT7 exhibits the highest predisposition to structural change. The changes then propagate through parallel fluxes of allosteric signals to neighbours on both rings. The predicted state-dependent mechanisms of sequential activation provide new insights into TRiC/CCT intra- and inter-ring signal transduction events., Support is gratefully acknowledged from NIH grants P41 GM103712 and P30DA035778 (IB) and MINECO BIO2016-76400-R (JMC and COSS).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

BIPSPI: a method for the prediction of Partner-Specific Protein-Protein Interfaces

  • Sánchez-García, Rubén
  • Sorzano, Carlos Óscar S.
  • Carazo, José M.
  • Segura, Joan
© The Author(s) 2018., [Motivation]: Protein–Protein Interactions (PPI) are essentials for most cellular processes and thus, unveiling how proteins interact is a crucial question that can be better understood by identifying which residues are responsible for the interaction. Computational approaches are orders of magnitude cheaper and faster than experimental ones, leading to proliferation of multiple methods aimed to predict which residues belong to the interface of an interaction. [Results]: We present BIPSPI, a new machine learning-based method for the prediction of partner-specific PPI sites. Contrary to most binding site prediction methods, the proposed approach takes into account a pair of interacting proteins rather than a single one in order to predict partner-specific binding sites. BIPSPI has been trained employing sequence-based and structural features from both protein partners of each complex compiled in the Protein–Protein Docking Benchmark version 5.0 and in an additional set independently compiled. Also, a version trained only on sequences has been developed. The performance of our approach has been assessed by a leave-one-out cross-validation over different benchmarks, outperforming state-of-the-art methods., Instituto de Salud Carlos III, project number PT13/0001/0009 and PT17/0009/0010 funding the Spanish National Institute of Bioinformatics. The Spanish Ministry of Economy and Competitiveness through Grants AIC-A-2011-0638, BIO2013-44647-R, BIO2016-76400-R (AEI/FEDER, UE), the ‘Comunidad Auto´noma de Madrid’ through Grant: B2017/BMD-3817. Horizon 2020 through Grant CORBEL (INFRADEV-1-2014-1—Proposal: 654248), ELIXIR-EXCELERATE (INFRADEV-1-2015-1—Proposal: 676559) and West-Life (EINFRA-2015-1, Proposal: 675858). J. Segura is recipient of a ‘Juan de la Cierva’ fellowship and R. Sanchez-Garcia is recipient of a FPU fellowship.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Cryo-Electron Tomography and Proteomics studies of centrosomes from differentiated quiescent thymocytes

  • Busselez, Johan
  • Chichón, Francisco Javier
  • Rodríguez, María Josefa
  • Alpízar, Adán
  • Gharbi, Severine
  • Franch, Mónica
  • Melero, Roberto
  • Paradela, Alberto
  • Carrascosa, José L.
  • Carazo, José M.
© The Author(s) 2019., We have used cryo Electron Tomography, proteomics and immunolabeling to study centrosomes isolated from the young lamb thymus, an efficient source of quiescent differentiated cells. We compared the proteome of thymocyte centrosomes to data published for KE37 cells, focusing on proteins associated with centriole disengagement and centrosome separation. The data obtained enhances our understanding of the protein system joining the centrioles, a system comprised of a branched network of fibers linked to an apparently amorphous density that was partially characterized here. A number of proteins were localized to the amorphous density by immunolabeling (C-NAP1, cohesin SMC1, condensin SMC4 and NCAPD2), yet not DNA. In conjuction, these data not only extend our understanding of centrosomes but they will help refine the model that focus on the protein system associated with the centriolar junction., This work was partially funded by the Spanish Ministry of Economy and Competitiveness (MINECO) grants BIO2013-44647-R and AIC-A-2011-0638 (to JMC), BIO2016-76400-R (JMC, RM), BFU2014-54181 (to JLC, FJC, MJR), the Consolider project CSD2006-00023 (JMC, JB), and by the Madrid regional government grant S2010/BMD-2305 (to JMC, JB, SIG, AA, MF). The proteomic analysis was performed at the Centro Nacional de Biotecnología (CNB-CSIC) Proteomics Facility, which is supported by grant PT13/0001 (ProteoRed, PRB2-ISCIII, which also funds AP)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

DeepRes: a new deep-learning- and aspect-based local resolution method for electron-microscopy maps

  • Ramírez-Aportela, Erney
  • Mota, J.
  • Conesa Mingo, Pablo
  • Carazo, José M.
  • Sorzano, Carlos Óscar S.
In this article, a method is presented to estimate a new local quality measure for 3D cryoEM maps that adopts the form of a `local resolution' type of information. The algorithm (DeepRes) is based on deep-learning 3D feature detection. DeepRes is fully automatic and parameter-free, and avoids the issues of most current methods, such as their insensitivity to enhancements owing to B-factor sharpening (unless the 3D mask is changed), among others, which is an issue that has been virtually neglected in the cryoEM field until now. In this way, DeepRes can be applied to any map, detecting subtle changes in local quality after applying enhancement processes such as isotropic filters or substantially more complex procedures, such as model-based local sharpening, non-model-based methods or denoising, that may be very difficult to follow using current methods. It performs as a human observer expects. The comparison with traditional local resolution indicators is also addressed., The authors would like to acknowledge financial support from: the Comunidad de Madrid through grant CAM (S2017/BMD-3817), the Spanish Ministry of Economy and Competitiveness (BIO2016-76400-R) and the European Union and Horizon 2020 through INSTRUCT-ULTRA (INFRADEV-03-016-2017, Proposal 731005), iNEXT (INFRAIA-1-2014-2015, Proposal 653706) and West-Life (EINFRA-2015-1, Proposal 675858).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Validation of electron microscopy initial models via small angle X-ray scattering curves

  • Jiménez, Amaya
  • Jonic, Slavica
  • Majtner, T.
  • Otón, Joaquín
  • Vilas, J. L.
  • Maluenda, D.
  • Mota, J.
  • Ramírez-Aportela, Erney
  • Martínez, Marta
  • Rancel, Y.
  • Segura, Joan
  • Sánchez-García, Rubén
  • Melero, Roberto
  • Caño, Laura del
  • Conesa Mingo, Pablo
  • Skjaerven, Lars
  • Marabini, Roberto
  • Carazo, José M.
  • Sorzano, Carlos Óscar S.
[Motivation]: Cryo electron microscopy (EM) is currently one of the main tools to reveal the structural information of biological macromolecules. The re-construction of three-dimensional (3D) maps is typically carried out following an iterative process that requires an initial estimation of the 3D map to be refined in subsequent steps. Therefore, its determination is key in the quality of the final results, and there are cases in which it is still an open issue in single particle analysis (SPA). Small angle X-ray scattering (SAXS) is a well-known technique applied to structural biology. It is useful from small nanostructures up to macromolecular ensembles for its ability to obtain low resolution information of the biological sample measuring its X-ray scattering curve. These curves, together with further analysis, are able to yield information on the sizes, shapes and structures of the analyzed particles. [Results]: In this paper, we show how the low resolution structural information revealed by SAXS is very useful for the validation of EM initial 3D models in SPA, helping the following refinement process to obtain more accurate 3D structures. For this purpose, we approximate the initial map by pseudo-atoms and predict the SAXS curve expected for this pseudo-atomic structure. The match between the predicted and experimental SAXS curves is considered as a good sign of the correctness of the EM initial map., This work was supported by the Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), Comunidad Autonoma de Madrid through Grant: S2017/BMD-3817, Instituto de Salud Carlos III, PT13/0001/0009, PT17/0009/0010 and European Union (EU) and Horizon 2020 through Grants: Elixir—EXCELERATE (INFRADEV-3-2015, Proposal: 676559), iNEXT (INFRAIA-1-2014-2015, Proposal: 653706) and INSTRUCT—ULTRA (INFRADEV-03-2016-2017, Proposal: 731005).
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

XTEND, Extending the depth of field in cryo soft X-ray tomography

  • Oton, Joaquin|||0000-0002-2195-4730
  • Pereiro, Eva|||0000-0001-7626-5935
  • Conesa, José J.
  • Chichón, Francisco J.
  • Luque, Daniel
  • Rodríguez, Javier M.|||0000-0003-0146-9903
  • Pérez Berna, Ana
  • Sorzano, Carlos Oscar S.|||0000-0002-9473-283X
  • Klukowska, Joanna
  • Herman, Gabor T.
  • Vargas, Javier
  • Marabini, Roberto|||0000-0001-7876-1684
  • Carrascosa, José L.
  • Carazo, José M.
We have developed a new data collection method and processing framework in full field cryo soft X-ray tomography to computationally extend the depth of field (DOF) of a Fresnel zone plate lens. Structural features of 3D-reconstructed eukaryotic cells that are affected by DOF artifacts in standard reconstruction are now recovered. This approach, based on focal series projections, is easily applicable with closed expressions to select specific data acquisition parameters.