Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Fluorescence determination of the pesticide Asulam by flow injection analysis

  • Súbová, I.
  • Assandas, A. K.
  • Catalá-Icardo, Mónica
  • Martínez Calatayud, J.
[EN] This paper presents the analytical determination of the pesticide Asulam based on its native fluorescence. The method was optimized in either a flow injection analysis (FIA) assembly or in batch. The maximum fluorescence intensity was observed for basic pH solutions and at a lambda(ex) of 258 nm and lambda(em) of 342 nm. The influence of different empirical parameters, such as the pH, the presence of surfactants, solvent polarity or solved oxygen amount, was studied. The calibration range was fitted with a linear equation from 0.01-3 mg l(-1) Asulam and 0.005-15 mg l(-1) Asulam for batch and continuous-flow, respectively. The RSD for both procedures was 1.0%. After testing the influence of a large series of potential interferents, the method was applied to water samples from different locations., This research was supported Ministerio Educación y Ciencia (Spanish Government), Project BQU2002-04248-C02-01
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Chemiluminescent determination of the pesticide bromoxynil by on-line photodegradation in a flow-injection assembly

  • Pawlicova, Z.
  • Albert-Garcia, J. R.
  • Sahuquillo, I.
  • García Mateo, J. V.
  • Catalá-Icardo, Mónica
  • Martínez Calatayud, J.
[EN] A new, robust and simple method is proposed for the chemiluminescent determination of the pesticide Bromoxynil. The empirical procedure is performed with the aid of a flow-injection manifold provided with an on-line photo-reactor to obtain chemiluminescent photofragments. After a period of 12 s of irradiation with an 8 W low-pressure mercury lamp, a chemiluminescent oxidation was performed with the system potassium permanganate in a polyphosphoric acid medium. The photolysis required a basic medium (KOH 0.014 mol l(-1)) with ethanol (1%) as a sensitizer. The method allowed the determination of 134 samples h(-1) of Bromoxynil in a wide interval of concentrations, over the range 5 x 10(-3) - 1 mg l(-1); the detection limit was 5 x 10(-3) mg l(-1). The RSD (n = 24) at 0.25 mg l(-1) of the pesticide level was 2.3%. The method was applied to a water sample and to a formulation., This research was supported by Ministerio de Educación y Ciencia (Spanish Government), Project BQU2002-04248-C02-01.